INSPECTION CIRCLE, SANCHAR VIKAS BHAWAN,
RESIDENCY ROAD, JABALPUR-482001 (MP)
ACCEPTANCE TESTING SCHEDULE
FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING
Document No: TD/TR/GPON-FTTH/11-12
No of Pages. 03
Issue No. 01
Issued By: Inspection Circle, Jabalpur
Approved By: CGM, Inspection Circle
Date of Issue: 12.03.2012
Amendment No (If Any) NIL
No of Pages:
Issued by:
Date of Issue:
Restricted use by BSNL Employees only
INSPECTION CIRCLE FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING
JABALPUR TEST SCHEDULE
TD/TR/GPON-FTTH/11-12 Page 3 of 3 Issue-I
Dated 12.03.2012
FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING
S No Test case Reference Remarks
1 Check of Approved layout
diagram & documentation
Hard/Soft Copies to be checked
2 OF cable Termination.
OF cable to be terminated on FTB as per EI No.-
EI/ACCESS NETWORK/11-12/13(House wiring of
FTTH) and P.O.
OF cable should be neatly laced and labeling to be
done.
3 Termination of OF cable on
splitter
Drop fibers from FTB are to be laid with suitable
protection and termination on splitter as per EI No.-
EI/ACCESS NETWORK/11-12/13 (House wiring of
FTTH) and P.O.
4 Cabling from splitter to
ONT Location
Drop fibre can be layed to ONT location through
micro duct/PVC pipe with suitable clampings as per
EI No.- EI/ACCESS NETWORK/11-12/13 (House
wiring of FTTH) and P.O.
5 Trench depth
Sample pits to be taken and trenching depth should
be as per EI No.- D-001 Issue IV dated 31.01.2007
(Laying practices of Optical fibre cable)
6 Optical link budget
RX sensitivity > -28 dbm at ONT Location
Power Loss calculated is as below
(Length in KM X 0.34 db/KM)+(0.15 db X no of
connectors)+ (0.1 db X no of splices) + (3 db
margin of error). Splitter losses to be added.
7 ONT installation
ONT, UPS to be wall mounted near A/C supply
point as per EI No.-EI/ACCESS NETWORK/11-
12/13(House wiring of FTTH) and P.O.
Hardware/software conformity of installed
equipment to be verified as per BOM.
8 Connectivity details and IP
details.
OLT to ONT path connectivity details.
9 Check of services Check services HSI, VOIP, IPTV, RF Overlay as per
the tariff plan.
10 Interruption Test
Physically isolated fibre at splitter/ONT and
reconnect.
System should start-up without any intervention.
11 Session stability Session stability to be carried out for 2 hrs.
12 Verification of data speed
for Triple Play Services
FTTH is capable of data speed for downstream up to
2.4 Gbps and upstream up to 1.2 Gbps
INSPECTION CIRCLE FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING
JABALPUR TEST SCHEDULE
TD/TR/GPON-FTTH/11-12 Page 2 of 3 Issue-I
Dated 12.03.2012
13 Check for splitter
specifications
Annexure-I EI No.-EI/ACCESS NETWORK/11-12/13(House
wiring of FTTH) and P.O.
14 Check of bending of Optical
cable
To avoid loss.
Annexure-I
Table 1. 1xN Symmetrical splitter –optical specifications
The following optical specifications must be met under any combination of environmental,
mechanical and polarization conditions. All values listed in this table do not account for
connectors.
Splitter 1x2 1x4 1x5 1x6 1x8 1x10 1x12 1x16 1x24 1x32 1x64
Insertion Loss
Maximum (dB)
(CR)
4.0 7.1 8.3 9.1 10.5 11.6 12.4 13.8 15.5 17.1 20.5
Uniformity
Maximum (dB)
0.3 0.5 0.6 0.7 0.8 0.9 1.0 1.0 1.2 1.3 2.0
Operating
Wavelength
1260-1360nm/1480-1580nm*
PDL (dB) < 0.2
Return Loss (dB) > 55
Directivity (dB) > 55
Fibre Type Single-mode fibre
Table 2. 2xN Symmetrical splitter –optical specifications
The following optical specifications must be met under any combination of environmental,
mechanical and polarization conditions. All values listed in this table do not account for
connectors.
Splitter 2x2 2x4 2x6 2x8 2x10 1x12 1x16 1x24 1x32 1x64
Insertion Loss
Maximum (dB)
(CR)
4.2 7.4 9.6 11.0 12.1 13.0 14.6 16.5 17.8 TBD
Uniformity
Maximum (dB)
1.1 1.2 1.6 1.6 1.7 2.2 2.4 2.8 3.0 TBD
Operating
Wavelength
1260-1360nm/1480-1580nm*
INSPECTION CIRCLE FTTH CUSTOMER PREMISES DUCTING AND FIBRE WIRING
JABALPUR TEST SCHEDULE
TD/TR/GPON-FTTH/11-12 Page 3 of 3 Issue-I
Dated 12.03.2012
PDL (dB) < 0.2
Return Loss (dB) > 55
Directivity (dB) > 55 Fibre Type Single-mode fibre
NOTE – I. Sharp bends to be avoided and all bends , conduits,ducts should correspond to EI No.-
EI/ACCESS NETWORK/11-12/13(House wiring of FTTH) and TR-SOFC-BWMF/T-
001 Dt 22.02.2010 (Blockwiring of multistory buildings for fibre)
II. Use of Existing and new electrical conduits are strictly banned.