FSRUG
Feedwater Systems Reliability Users Group (Jan 2012)
San Antonio, TX
SGFP Minimum Flow Operations –
Impact on Reliability
Presenter:
Art Washburn, P.E.
![Page 2: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/2.jpg)
FSRUG
• ICE BREAKER
![Page 3: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/3.jpg)
FSRUG
TOPICS• Two Rules to Get You Home• Minimum Flow Protection – WHAT and WHY?• Minimum Flow Operation - Problems• Minimum and Maximum Flow Rates• Minimum Flow Energy Levels• Calculate Recommended Minimum Flow Rate• Guide for Minimum Flow Operation of Pumps• Recirculation - Large vs. Small Eye Impeller Design• Predicted Performance Curve for Replacement Feedwater Pump• Recirculation – Affect on Part Flow Operation and Corrected by
Computational Fluid Dynamics (CFD) Analysis• Common Discussions Between User and Pump Supplier• Using Minimum Flow Protection for Discharge Piping Overpressure
Protection• Minimum Flow Protection – Why ?• Source References
![Page 4: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/4.jpg)
FSRUG
Two Rules:
![Page 5: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/5.jpg)
FSRUG
Two Rules:
Rule #1 – Make Conservative Decisions
![Page 6: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/6.jpg)
FSRUG
Two Rules:
Rule #1 – Make Conservative Decisions
Rule #2 – Maintain Design Control
![Page 7: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/7.jpg)
FSRUG
Two Rules:
Rule #1 – Make Conservative Decisions
Rule #2 – Maintain Design Control
Plant Priorities:
![Page 8: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/8.jpg)
FSRUG
Two Rules:
Rule #1 – Make Conservative Decisions
Rule #2 – Maintain Design Control
Plant Priorities:
1. Nuclear Safety
![Page 9: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/9.jpg)
FSRUG
Two Rules:
Rule #1 – Make Conservative Decisions
Rule #2 – Maintain Design Control
Plant Priorities:
1. Nuclear Safety
2. Legal Requirements
![Page 10: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/10.jpg)
FSRUG
Two Rules:
Rule #1 – Make Conservative Decisions
Rule #2 – Maintain Design Control
Plant Priorities:
1. Nuclear Safety
2. Legal Requirements
3. Efficiency
![Page 11: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/11.jpg)
Minimum Flow Protection – WHAT and WHY?
FSRUG
- Assure Shutoff Head (zero flow) Operation Does Not Occur to Protect Pump from Catastrophic Damage
- Extreme Minimum Flow (Unacceptable Temperature Rise)
- Excessive Vibration (Damaging to Equipment)
- Minimum Flow Path Recirculation Back to Pump Suction to a Large Volume Tank (Deaerator, Condenser)
- Minimum Flow Controlled by Valve, Orifice Assembly
- Main System Pump Suction Flow Velocity (8-10 FPS)
- Main System Pump Discharge Flow Velocity (18-20 FPS)
- Minimum Flow Piping Velocity (25-30 FPS)
![Page 12: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/12.jpg)
Minimum Flow Operation – Problems
FSRUG
- Pump Oversized for Application- Inlet Eye Diameter (too large, not optimum) - Head per Stage excessively high (OEM Pumps
from 1970s)- Operating Strategy Changes since original Plant
Specification- Minimum Flow Rate (thermal protection vs.
continuous minimum flow rate)
![Page 13: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/13.jpg)
Minimum and Maximum Flow Rates
FSRUG
Recommended flow rate ranges for minimum and maximum, continuous and short-term, operation. From Gülich, Centrifugal Pumps.
nq = ns x 0.01936
Specific Speed, ns
ns = (n x Q1/2)/(H3/4)
Suction Specific Speed, nss
nss = (n x Q1/2)/(NPSHR3/4)
![Page 14: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/14.jpg)
Minimum and Maximum Flow Rates
FSRUG
![Page 15: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/15.jpg)
Minimum and Maximum Flow Rates
FSRUG
![Page 16: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/16.jpg)
Minimum and Maximum Flow Rates
FSRUG
Ref. ISO/CD 10816-7:2004(E)
![Page 17: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/17.jpg)
FSRUG
Minimum Flow Energy Levels
The following criteria has an effect on determining minimum flow rates:
• Specific Speed (Ns)• Suction Specific Speed (Nss)• Energy Level• Vibration / Pulsation Requirements• Service• Hours of Operation• Pumpage• Temperature Rise – Vapour Pressure• Ratio NPSHA to NPSHR• Impeller Material• Impeller Design• Lip Clearance• Normal Duty Energy Level Pumps
![Page 18: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/18.jpg)
FSRUG
Minimum Flow Energy Levels• "Normal Duty" Energy Level for Pumps• "Heavy Duty" • "High Energy" (API-610 - greater than 650 FT/STAGE and
greater than 350 HP/STAGE)
![Page 19: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/19.jpg)
Calculate Recommended Minimum Flow Rate
FSRUG
SGFP – Sulzer 16 x 18 x 17 CD 1 Stage, 5200 RPM
![Page 20: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/20.jpg)
Figure 1 - Guide for Minimum Flow Operation of Pumps
FSRUG
![Page 21: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/21.jpg)
Application Notes for Figure 1
FSRUG
1) The minimum flow values given are for continuous operation. Continuous operation is considered as more than 2-hours in any 24 hours of operation.
2) For intermittent operation, reduce the minimum flow values given by 10 percentage points.
3) The minimum flow values given are for suction specific speeds (Nss) less than 10,000. Above 10,000 Nss, then increase the values given by 2 percentage points for each 1,000 Nss greater than 10,000 Nss.
4) The minimum flow values are percentages of flow at Best Efficiency Point (B.E.P.) flow taken as 100%.
5) Specific Speed (Ns), Suction Specific Speed (Nss) and head per stage are determined at best efficiency point for the actual impeller trim performance.
6) For multistage pumps, use the Specific Speed (Ns), Suction Specific Speed (Nss), and the head per stage of the first stage impeller.
7) Specific Speed (Ns) and Suction Specific Speed (Nss) for double suction impellers are based on 50% of total flow.
![Page 22: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/22.jpg)
Calculate Recommended Minimum Flow Rate
FSRUG
SGFP – Sulzer 16 x 18 x 17 CD 1 Stage
n = 5,200 RPM
Q = 20,000 GPM @ BEP
H = 2,300 FT/STAGE @ BEP
NPSHR = 190 FT @ BEP
ns = (n x Q1/2)/(H3/4)
= (5200 x 20,0001/2)/(23003/4) = 2200
nss = (n x Q1/2)/(NPSHR3/4)
= (5200 x 10,0001/2)/(1903/4) = 10,000
Min Flow = (0.60)(20,000) = 12,000 GPM
![Page 23: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/23.jpg)
Recirculation – Large Vs Small Eye Impeller Design Suction and Discharge
Recirculation occurs at off peak (low flow) conditions. The turbulent mixing action due to suction or discharge re-circulation leads to surging, pulsations, vibration, and noise
FSRUG
![Page 24: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/24.jpg)
Recirculation – Large Vs Small Eye Impeller Design
• Recirculation & Cavitation Damage
• Large Eye = High Nss (suction specific speed)
FSRUG
![Page 25: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/25.jpg)
FSRUG
Predicted Performance Curve for Replacement Feedwater Pump
![Page 26: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/26.jpg)
Recirculation – Large Vs Small Eye Impeller Design
Eye Diameter = 7.38” (Large Eye)NSS = 17,000
6 x 10 x 14 CD
Large eye NPSH performance test, notice
the unstable high vibration at low flows.
FSRUG
![Page 27: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/27.jpg)
Recirculation – Large Vs Small Eye Impeller DesignFSRUG
![Page 28: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/28.jpg)
Recirculation – Large Vs Small Eye Impeller Design; Pump Vibration Levels
‘Large eye’ 4 vanes96.4%
Max.Dia.
‘Small eye’ 5 vanes96.4%
Max.Dia.
PermissibleVibration
Limit
Vib
rati
on L
evel
Vef
f (1
0-10
-100
0 H
z) /
mm
.s-1 (
RM
S)
Flow Rate / gal (UK)/Min
Slide shows the difference between the twoimpeller designs in vibration levels.
FSRUG
![Page 29: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/29.jpg)
Recirculation – Large Vs Small Eye Impeller DesignStall ring design is a temporary fix, to have the same influence as the small eye design on the pump suction performance, note the B.E.P will not be repositioned with this fix
FSRUG
![Page 30: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/30.jpg)
Recirculation – Large Vs Small Eye Impeller Design
FSRUG
Equation for Optimizing Eye Diameter:
Eye Diameter (I.D.) =
[(51.27)(Q/N)^0.666 + (Dia Shaft)^2]^0.5
![Page 31: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/31.jpg)
Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis
FSRUG
Closed Impellers typically are lift set based on total mechanical endplay, and thermal growth. The location of the impeller to volute cutwater on discharge and suction can affect suction and discharge recirculation.
![Page 32: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/32.jpg)
Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis
FSRUG
![Page 33: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/33.jpg)
Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis
FSRUG
![Page 34: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/34.jpg)
Recirculation – Affect on Part Flow Operation and Corrected by Computational Fluid Dynamics (CFD) Analysis
FSRUG
![Page 35: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/35.jpg)
Common Discussions between Utility and Pump Supplier for Replacement Pump or Repaired Pump:
• Continuous Minimum Flow Required by Specification vs. Existing Limitations of Minimum Flow Piping Size
• Vibration Limits Required by Specification (recent limits are more stringent)
• Demands to Guarantee Mechanical Performance (Vibration) on Test Stand and in Field
FSRUG
![Page 36: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/36.jpg)
FSRUG
Using Minimum Flow Protection for Discharge Piping Overpressure Protection
Common on Heater Drain Pumps
Be Aware When Rerating as Part of EPU
![Page 37: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/37.jpg)
FSRUG
Minimum Flow Protection – Why ?
- Shutoff Head Operation
![Page 38: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/38.jpg)
SOURCE REFERENCES:• Centrifugal Pumps: Design & Application, Lobanoff and Ross
(practical application)• Centrifugal and Axial Flow Pumps, Stepanoff
(theory)• Centrifugal Pumps, Gülich
• Vertical Turbine, Mixed Flow & Propeller Pumps, Dicmus• Centrifugal Pump Handbook, Sulzer• Pump Handbook, Karassik• Centrifugal Pump Clinic, Karassik• Centrifugal Pumps Selection & Operation, Karassik• Centrifugal Pumps, Karassik
FSRUG
![Page 39: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/39.jpg)
FSRUG
• ICE BREAKER
![Page 40: FSRUG](https://reader030.fdocuments.in/reader030/viewer/2022032804/56812a87550346895d8e22b2/html5/thumbnails/40.jpg)
THE (HAPPY) END
QUESTIONS ?
FSRUG