Front & Back M CAT 2 - Acson · PDF fileAmp GPM (l/s) mm(in) m litres kg dBA ... accommodate...
Transcript of Front & Back M CAT 2 - Acson · PDF fileAmp GPM (l/s) mm(in) m litres kg dBA ... accommodate...
AP - MAC - AR - 02162
Air Cooled Mini Chiller
Air Cooled Mini Chiller
•Specif ications•
HEAT PUMP MODELS
3654042490145000
3150036630125000
MAC040AR MAC050AR MAC058AR MAC075BR MAC100BR MAC125BR
COOLING ONLY MODELS MAC040A MAC050A MAC058A MAC075B MAC100B MAC125B
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
kcal/h
kcal/h
W
W
Btu/hr
Btu/hr
75608790300008060938032000
108401260043000
126001465050000
234402725093000
2520029300100000
100801172040000
121001406048000
201602344080000
236902754094000
3150036630NOMINAL COOLING CAPACITY
CASING
TOTAL UNIT DIMENSION
PUMP
PIPING
TANK
TOTAL WEIGHTNOISE LEVEL
TYPEWATER VOLUMENOMINAL WATER FLOW
EVAPORATOR
WATER LINE (HYDRAULIC KIT)
CONDENSER COIL
CONDENSER FAN
COMPRESSOR
REFRIGERANT
MATERIALFINISHTHICKNESSHEIGHT (H)WIDTH (W)DEPTH (D)
TYPE
POWER SUPPLY
RUNNING CURRENTWATER FLOW RATE
INSTALLATION PIPE CONNECTIONHEAD
MATERIAL
CAPACITY/VOLUME
kcal/hW
Btu/hr
mmmm(in)mm(in)mm(in)
m3
l/s
V/Ph/Hz
Amp
GPM (l/s)
mm(in)m
litres
kgdBA
75608790
1008011720
11342(52.8)1032(40.6)558(22.0)
1260014650
ELECTRO-GALVANISED MILD STEELPOLYESTER POWDER
STAINLESS STEEL BRAZED PLATE HEAT EXCHANGER
HORIZONTAL MULTISTAGE END-SUCTION
380-415/3/50
42mm BSP (11/4")
BLACK MILD STEEL
CROSS FINNED TUBESSEAMLESS COPPER
0.35(0.014)9.52(3/8)
ALUMINIUM0.127(0.0005)
PROPELLER/DIRECT
380-415/3/50
OVERLOAD PROTECTION, FLOW SWITCH AND H/L PRESSURE SWITCHON/OFF
R22THERMOSTATIC EXPANSION VALVE
FLARE VALVE FITTINGS
2
2016023440
2520029300
12500030000 40000 50000 80000 100000
380150 155 160 350 3507458 58 71 65 65
0.0030.00075 0.001 0.0014 0.00143 0.00191.750.42 0.56 0.70 1.12 1.40
1.51.02 1.02 1.05 1.5 1.5
18
762(30)
24
14
22
32
0.87(9.36)
ACRYL STYRENE RESIN609.6(24)
99/3500
RECIPROCATING
220-240/1/50
20 27
16
23
150
2.95(31.75)
ALUMINIUM660.4(26)
380-415/3/50
27.75(1.751)6.66(0.421) 8.89(0.561) 11.10(0.7) 17.78(1.122) 22.22(1.402)
7.403.10 3.00 2.90 5.50 5.508.602.10 2.38 2.50 7.90 7.90
23.05.34 7.11 8.29 14.7 15.322.0/23.35.52/5.62 7.50/7.24 7.90/8.20 15.6/15.7 17.5/17.2
132202983 4343 4681 7700 901012832/138823212/3187 4373/4084 4341/4656 8200/8500 9410/9174
19845
9.52(3/8) 12.7(1/2)
62
19.05(3/4)
74 125 167
NILNIL NIL
NILNIL NIL
68 8 6 6 63.61.09 1.09 1.8 1.4 1.4
1250145 145 400 588 5881978
297/10500241 241 420
127/4500640
176/6200
SCROLL
640
1.51739(68.5)1089(42.9)1288(50.7)
TYPE
TUBE
FIN
FACE AREA
TYPE/DRIVE
TYPEPOWER SUPPLYRATED RUNNING CURRENT-COOLING ONLY
RATED INPUT-COOLING ONLYRATED INPUT-HEATING PUMP (COOLING/HEATING)
BLADE MATERIALBLADE DIAMETERPOWER SUPPLYMOTOR POLERATED RUNNING CURRENT
MATERIALTHICKNESSOUTER DIAMETERMATERIALTHICKNESSROWSFIN PER INCH
DISCHARGE
SUCTION
COOLING ONLY
HEAT PUMP
mm(in)mm(in)
mm(in)
mm(in)
mm(in)
mm(in)
kg
kg
V/Ph/Hz
V/Ph/Hz
Amp
Amp
MAX STARTING CURRENTPROTECTION DEVICESTAGE OF CAPACITY CONTROL
TYPECONTROLREFRIGERANT PIPE CONNECTION
PIPE SIZE
CHARGING MASS
Amp
RATED RUNNING CURRENT-HEAT PUMP (COOLING/HEATING) Amp
RATED OUTPUTRATED INPUT
WattWatt
WattWatt
AIR VOLUME cmm/cfm
m2(ft2)
1.ALL SPECIFICATIONS ARE SUBJECT TO CHANGE BY MANUFACTURER WITHOUT PRIOR NOTICE.2.NOMINAL VALUES ARE BASED ON ENTERING/LEAVING CHILLED WATER TEMPERATURE 12˚C/7˚C AND AIR AMBIENT TEMPERATURE 35˚C.3.NOMINAL VALUES ARE BASED ON ENTERING/LEAVING HOT WATER TEMPERATURE 40˚C/45˚C AND AIR AMBIENT TEMPERATURE 7˚C.
©2002 McQuay International +1 (800) 432-1342 www.mcquay.com
ISO 9002
REGISTERED
Your Climate, We ' re There
OUR STRENGTH
Installation Friendly
The light weight condenser and fan coil unit are designed for ease of installation. The condenser unit is compact and light, enabling easy handling and transportation.
Capacity Versatility
No cooling tower is required as this unit is an air cooled water chiller system.
McQuay Mini Chiller can be coupled with different models of Fan Coil Units (F.C.U.). The quantity of F.C.U. can be coupled depending on the chiller cooling capacity and the total requirement of F.C.U. cooling capacity.
Mini Chiller can be installed anywhere and even far away from the fan coil unit allowing maximum flexibility and creativity in the site installation.
The new slim and compact design offers maximum flexibility for multi storey applications because it can be placed anywhere in a building. The condenser can be placed at the centralised location on the top or bottom of the building or on each floor to suit the building requirement.
These machine allows flexibility in operation where air-conditioning can be controlled to suit individual requirement at the particular location.
The piping length can be extended to suit the building height while the water pump can be changed to accommodate the length of piping which allow very high flexibility in unit installation.
Eco Friendly And Safety
The Mini Chiller is ideal for offices, shopping complexes and hotels which require zone control or individual cooling operation as the fan coil unit can be controlled separately.
Zone Control
The Mini Chiller is a new innovation in air conditioning technology. It is an alternative for large chiller system or multi split direct expansion system. Mini Chiller is more eco friendly because only a small quantity of refrigerant is needed.
Maximum Flexibility
The cabinet is made of electro galvanised mild steel sheet with anti-corrosion treatment and then bonderized and coated with baked polyester powder paint to withstand all weather conditions.
Durable In All ClimatesAll the components in the unit can be easily accessible by removing the front and rear panel to facilitate the process of repair and maintenance.
Service Friendly
McQuay Mini Chiller is equipped with intelligently designed safety control to ensure continuous safe
operation. The refrigerant is confined in the outdoor condenser unit making it safe and hazard-free for the inhabitant.
Refrigerant is prefilled in the factory under strict quality control. Thus, ensuring
safety and reliability.
Individual Mini Chiller can be connected to form a module and the module can be operated as a single unit with one larger pump and tank.
CBS CORPORATE