Frenchwood Hinged Patio Doors Contents/media/aw/files/... · REV.03/05 A R C H I T E C T U R A L D...
Transcript of Frenchwood Hinged Patio Doors Contents/media/aw/files/... · REV.03/05 A R C H I T E C T U R A L D...
A R C H I T E C T U R A L D E T A I L F I L E 10-1 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Contents
Frenchwood® Hinged Patio Doors
Basic Unit Details
Single and Two Panel ........................................................... 10-2
Two Panel ............................................................................ 10-4
Three Panel ......................................................................... 10-6
Stationary Panel .................................................................. 10-8
Options / Accessories
Extension Jambs - Interior and Exterior ................................ 10-9
Exterior Extension Jambs - Single Insect Screen Track ........ 10-10
Exterior Extension Jambs - Double Insect Screen Track ....... 10-10
Sill Extensions ................................................................... 10-11
Ramped Sill Insert - Interior and Exterior ........................... 10-12
Andersen® Grilles ............................................................... 10-13
Anchoring Methods .................................................................. 10-15
Joining Details ......................................................................... 10-16
Suggested Product Applications ............................................... 10-18
• Low-maintenance, durable exterior available in White, Sandtone, Terratone® or Forest Green colors
• Natural wood interior in pine, oak, maple or prefinished white
• Smooth, easy operation
• 20/10 year limited warranty, fully transferable non-prorated
• High-Performance™ Low-E tempered or High-Performance Sun™ Low-E tempered glass is standard
• Patented multiple-point locking system for added security and performance
A R C H I T E C T U R A L D E T A I L F I L E10-2 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Basic Unit Details - Single and Two Panel
Vertical Section - with Hinged Insect ScreenSingle Panel - Active
Two Panel - Active/Passive or Passive/Active
Basic UnitScale 3" = 1'-0" (1:4)
Clea
r Ope
ning
Hei
ght
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1-5/16"(33) 4-9/16" (116)
1-11/16" (43)
3/4" (19)
1-1/16" (27)
1" (25)
1/2" (13)
6-3/16" (157)
5/16" (8)
10-3/8"+ (264 +)depending on
hinge adjustment
5-5/8"+ (143 +)depending on
hinge adjustment
Optional Andersen®
hingedinsectscreen
Head
SillOptional Andersen®
oak or maple threshold
A R C H I T E C T U R A L D E T A I L F I L E 10-3 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Basic Unit Details - Single and Two Panel
Basic UnitScale 3" = 1'-0" (1:4)
Horizontal Section - with Hinged Insect ScreenSingle Panel - Active
Horizontal Section - with Hinged Insect ScreenTwo Panel - Active/Passive (shown) or Passive/Active
** These dimensions relate to location of astragal center line.
5-5/8"(143)
1"(25)
5-5/8"(143)
1"(25)
Unit Dimension Width
Rough Opening Width
3/8" (10) 3/8" (10)
Clear Opening Width2-1/16"
(52)2-1/16"
(52)
Optional Andersen®
hinged insect screen
Jamb Jamb
Optional Andersen®
hinged insect screen
LC50**=2’ 5-5/8" (752)54**=2’ 7-5/8" (803)
60**= 2' 11-5/8" (905)
50**=2’ 5-5/8" (752)54**=2’ 7-5/8" (803)
60**= 2' 11-5/8" (905)
Jamb JambAstragal
Active Panel Passive Panel
5-5/8" (143)
1"(25)
5-1/8" (130)
1"(25)
5-1/8" (130) 5-5/8" (143)
A R C H I T E C T U R A L D E T A I L F I L E10-4 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Basic Unit Details - Two Panel
Vertical Section - with Gliding Insect ScreenTwo Panel - Active/Passive or Passive/Active
Basic UnitScale 3" = 1'-0" (1:4)
Vertical Section - with Gliding Insect ScreenTwo Panel - Active/Stationar y or Stationar y/Active
1-11/16"(43)
1-5/16"(33)
1-1/16" (27)
1" (25)
4-9/16" (116)
1/2" (13)
10-3/8"+ (264 +)depending on
hinge adjustment
5-5/8"+ (143 +)depending on
hinge adjustment
6-3/16" (157)
15/16" (24)
Clea
r Ope
ning
Hei
ght
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t Head
Sill
Optional Andersen®
gliding insect screen
1-11/16" (43)
1-5/16"(33)
1-1/16" (27)
1" (25)
1/2" (13)
10-3/8"+ (264 +) depending on
hinge adjustment
5-5/8"+ (143 +) depending on
hinge adjustment
6-3/16" (157)
5/16" (8)
Clea
r Ope
ning
Hei
ght
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
4-9/16" (116)
Head
Sill
Optional Andersen®
gliding insect screen
A R C H I T E C T U R A L D E T A I L F I L E 10-5 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Basic Unit Details - Two Panel
Basic UnitScale 3" = 1'-0" (1:4)
Horizontal Section - with Gliding Insect ScreenTwo Panel - Active/Passive (shown) or Passive/Active
1"(25)
1"(25)
5-5/8"(143)
5-5/8"(143)
5-1/8"(130)
50**= 2' 5-5/8" (752)54**= 2' 7-5/8" (803)60**= 2' 11-5/8" (905)
LC
5-1/8"(130)
50**= 2' 5-5/8" (752)54**= 2' 7-5/8" (803)60**= 2' 11-5/8" (905)
Jamb JambAstragal
Active Panel Passive Panel
Optional Andersen®
gliding insect screen
Horizontal Section - with Gliding Insect ScreenTwo Panel - Active/Stationar y or Stationar y/Active (shown)
1"(25)
1"(25)
5-5/8"(143)
5-5/8"(143)
5-1/8"(130)
50**= 2' 5-5/8" (752)54**= 2' 7-5/8" (803)60**= 2' 11-5/8" (905)
5-1/8"(130)
50**= 2' 5-5/8" (752)54**= 2' 7-5/8" (803)60**= 2' 11-5/8" (905)
LCJamb Jamb
Active PanelStationary Panel
Astragal
Optional Andersen®
gliding insect screen
** These dimensions relate to location of astragal center line.
A R C H I T E C T U R A L D E T A I L F I L E10-6 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Basic Unit Details - Three Panel
Vertical Section - with Gliding Insect ScreenThree Panel - Active
Basic UnitScale 3" = 1'-0" (1:4)
Vertical SectionThree Panel - Stationar y
Clea
r Ope
ning
Hei
ght
Unit
Dim
ensi
on H
eigh
t
1-5/16"(33)
1-1/16" (27)
1" (25)
5-5/8"+ (143 +)depending on
hinge adjustment
1-11/16" (43)
1/2" (13)
10-3/8"+ (264 +)depending on
hinge adjustment
6-3/16" (157)
5/16" (8)
Roug
h Op
enin
g He
ight
4-9/16" (116)
Head
Sill
Optional Andersen®
gliding insect screen
Clea
r Ope
ning
Hei
ght
Unit
Dim
ensi
on H
eigh
t
1-5/16"(33)
1-1/16" (27)
1" (25)
5-5/8"
1-11/16" (43)
1/2" (13)
10-3/8"
6-3/16" (157)
5/16" (8)
Roug
h Op
enin
g He
ight
4-9/16" (116)
Head
Sill
A R C H I T E C T U R A L D E T A I L F I L E 10-7 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
5-5/
8" (1
43)
80**
= 2'
7-1
3/16
" (8
08)
90**
= 2'
11-
13/1
6" (9
10)
80**
= 2'
7-1
3/16
" (8
08)
90**
= 2'
11-
13/1
6" (9
10)
C L80
**=
2' 7
-1/2
" (8
00)
90**
= 2'
11-
1/2"
(902
)
1" (25)
1" (25)
5-5/
16"
(135
) 5-
5/16
" (1
35)
5-5/
16"
(135
) 5-
5/16
" (1
35)
5-5/
8" (1
43)
C L
Stat
iona
ry P
anel
Activ
e P a
nel
Stat
iona
ry P
anel
Jam
bAs
trag
alJa
mb
Astr
agal
Optio
nal A
nder
sen®
glid
ing
inse
ct s
cree
n
Basic Unit Details - Three Panel
Basic UnitScale 3" = 1'-0" (1:4)
Hor
izon
tal
Sect
ion
- w
ith
Gli
ding
Ins
ect
Scre
enTh
ree
Pane
l -
Sta
tion
ary/
Acti
ve/S
tati
onar
y
** Th
ese
dim
ensi
ons
rela
te to
loca
tion
of a
stra
gal c
ente
r lin
e.
A R C H I T E C T U R A L D E T A I L F I L E10-8 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Basic Unit Details - Stationar y Panel
Vertical SectionStationar y Panel
Basic UnitScale 3" = 1'-0" (1:4)
Horizontal SectionStationar y Panel
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
1-5/16"(33)
6-3/16" (157)
5/16"(8)
1-1/16" (27)
1" (25)
5-5/8"
1-11/16" (43)
1/2" (13)
10-3/8"
4-9/16" (116)
Head
Sill
Unit Dimension Width
Rough Opening Width
2-1/16" (52)
2-1/16" (52)
5-5/8"(143)
5-5/8"(143)
1"(25)
1"(25)
Stationary Panel
Jamb Jamb
A R C H I T E C T U R A L D E T A I L F I L E 10-9 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Options / Accessories
Extension Jambs - Interior and ExteriorScale 3" = 1'-0" (1:4)
Horizontal Section
Interior extension jambs are available for 5-1/4" (133), 6-9/16" (167), and 7-1/8" (181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification. Extension jambs are pre-drilled for easy application, except for 7-1/8" (181) size. See the following pages for exterior extension jamb applications.
11/16" (17)*
5-1/4" (133) Side cover
2" (51)*3" (76)*
7-9/16" (192)Side cover
6-9/16" (167)Side cover
5-1/4" (133)Extension jamb
6-9/16" (167)Extension jamb
7-1/8" (181)Extension jamb
Face
: 3/4
" (1
9)
Face
: 2"
(51)
Face
: 2-9
/16"
(65)
1-5/16" (33)
4-9/16" (116)
11/16" (17)
Unit Dimension Width
Rough Opening Width
3/4" (19)Side clip
* Minimum dimension (adjustable to +5/32")
A R C H I T E C T U R A L D E T A I L F I L E10-10 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Options / Accessories
Exterior Extension Jambs - Single and Double Insect Screen TrackScale 3" = 1'-0" (1:4)
Vertical SectionDouble Insect Screen Track Kit
Vertical SectionSingle Insect Screen Track Kit
OptionalAndersen® head clip
OptionalAndersen® 5-1/4" (133)head cover
3/4"(19)
2" (51)
5-7/8" (149)
3" (76)
4-1/2" (114)
OptionalAndersen® head clip
OptionalAndersen® 6-9/16" (167)head cover
OptionalAndersen® head clip
OptionalAndersen® 7-9/16" (192)head cover
1"(25) 5-7/8" (149)
2"(51)
3"(76)
4-1/2" (114)
OptionalAndersen® head clip
OptionalAndersen® 7-9/16" (192)head cover
OptionalAndersen® head clip
OptionalAndersen® 6-9/16" (167)head cover
OptionalAndersen® head clip
OptionalAndersen® 5-1/4" (133)head cover
A R C H I T E C T U R A L D E T A I L F I L E 10-11 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
4-9/16" (116)1-5/8" (41)
1-5/8" (41)
1-5/8" (41)
1-5/8" (41)
6-9/16" (167)
7-9/16" (192)
5-1/4" (133)Optional Andersen® extruded aluminum exterior sill extension and PVC spacer
OptionalAndersen® metal sill support
Options / Accessories
Sill ExtensionsScale 3" = 1'-0" (1:4)
Sill extensions are available for 4-9/16" (116), 5-1/4" (133), 6-9/16" (167), and 7-9/16" (192) wall thickness.
Vertical Section
A R C H I T E C T U R A L D E T A I L F I L E10-12 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Options / Accessories
Ramped Sill Insert - Interior and ExteriorScale 3" = 1'-0" (1:4)
Vertical Section
8
1
5/16"(8)
1-7/16" (37)
1/4"(6)
1/4"(6)
1-9/16" (40)
5/16" (8) 10-1/8" (257)
Center Ramp
Track Cover
Exterior Ramp
10-7/8" (276) maximum. Cut to fit height.Flashing by others
A R C H I T E C T U R A L D E T A I L F I L E 10-13 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Options / Accessories
Andersen® Divided Light Grilles
White
Sandtone
Terratone®
Forest Green
3/4"
7/8"
1-1/8"
2-1/4"
With Spacer
Without Spacer
Maple
Oak
Prefinished
Pine
Colonial
Modified Colonial
Modified Col W/Check Rail
Prairie A
Short Fractional
Short Fractional W/Check Rail
Tall Fractional
Tall Fractional W/Check Rail
Victorian
Renaissance
Sunburst
Specified Equal Light
Custom
HP/HP Tempered
HP Sun/HP Sun Temp
3/8" Low-E/Temp
Single-Pane Impact
Available now
Available only with 3/8" glass through the Andersen Divided Light program
Please check with Andersen for availability
Andersen®400 Series Windows
Gla
ss
Patt
erns
In
terio
r Ty
pe
Wid
th
Exte
rior C
olor
Andersen®400 Series Doors
Case
men
t & A
wnin
g
Case
men
t Pic
ture
Win
dow
Glid
ing
Win
dow
Woo
dwrig
ht®
Doub
le-H
ung
& Tr
anso
m
Woo
dwrig
ht®
Pict
ure
Win
dow
Woo
dwrig
ht®
Arch
top
& U
nequ
al L
eg A
rcht
op
Woo
dwrig
ht®
Sprin
glin
e Si
ngle
-Hun
g
Tilt-
Was
h Do
uble
-Hun
g &
Tran
som
Tilt-
Was
h Pi
ctur
e W
indo
w
Circ
le To
p™ &
Qua
rter R
ound
Arch
Sprin
glin
e™
Flex
ifram
e®
Ellip
tical
Circ
le &
Ova
l
Goth
ic
200
Serie
s Na
rrolin
e® D
oubl
e-Hu
ng &
Tran
som
Fren
chwo
od®
Glid
ing
Fren
chwo
od®
Hing
ed In
swin
g
Fren
chwo
od®
Hing
ed O
utsw
ing
Fren
chwo
od®
Patio
Doo
r Sid
elig
hts &
Tran
som
s
A R C H I T E C T U R A L D E T A I L F I L E10-14 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Andersen® Divided LightPermanent ExteriorPermanent Interiorwith Spacer
Andersen® Divided LightPermanent ExteriorPermanent Interior
Andersen® Divided LightPermanent ExteriorRemovable Interior
RemovableInterior
Andersen® Finelight™Grilles-Between-the-Glass
3/32"
5/16"
5/16" 7/16"
7/16"
45˚
2-1/4"
53˚3/8"3/8"3/8" 53˚
7/8"
45˚45˚
3/4"
53˚ 35˚
1-1/8"
35˚
1/2"
1-13/16"
5/16" 7/16"
2-1/4"7/8"3/4" 1-1/8"
1/2"
7/8"3/4" 1-1/8"
1/2" 1-13/16"
5/16"5/16"5/16"
3/16"1/8" 5/16"
1/2"
1/8"
1/2" 1/2" 1/2" 1/2"
Permanent Exterior Fibrex® Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright® double-hung windows.
Permanent Interior Wood Grille Profiles (chamfer profile).The Fibrex® material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright® double-hung windows.
Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile).400 Series Woodwright® double-hung windows only.
Permanent Full Divided Light Grille spacer location.
Andersen® Finelight™ Grilles-Between-the-Glass.
7/16"
7/8"3/4" 1-1/8"
3/8"
3/4"
1/2"
1"
Options / Accessories
Grille Profiles • Scale = Full • Dimensions include thickness of tape.
400 Series Grille Options
A R C H I T E C T U R A L D E T A I L F I L E 10-15 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Anchoring Methods
Installation FlangeScale 3" = 1'-0" (1:4)
Threaded Masonr y Fastener / Expansion SleeveScale 3" = 1'-0" (1:4)
Patio door unit is secured in opening using threaded fasteners through the jamb (the installation flange itself cannot support the door). Standard installation flange application shown.
Patio door unit is secured in opening by pre-drilling through side jamb into masonry.
4-9/
16"
(116
)
Installation flange
Exterior sheathing
4-3/
16"
(106
)
Installation flange in reverse position
Threaded masonry anchor (by others)
Installation Flange ReversedScale 3" = 1'-0" (1:4)
Patio door unit is secured in opening using threaded fasteners through the jamb (the installation flange itself cannot support the door). Regular installation flange in reverse position shown.
Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed.
A R C H I T E C T U R A L D E T A I L F I L E10-16 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Andersen® Joining MaterialsScale 3" = 1'-0" (1:4)
Andersen Aluminum Non-reinforced Mullion
Joining Details
Andersen LVL Mullion
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
Andersen Aluminum Non-reinforced Transom
Andersen LVL Transom
3/16"(5)
1" (25)1" (25)
3/16" (5)
OptionalAndersen®
non-reinforced aluminum joining strip
OptionalAndersen® 2" (51)wood casing
OptionalAndersen®
exterior vinyltrim strip setin continuousbead of sealanteach side
Unit
Dim
ensi
on H
eigh
tUn
it Di
men
sion
Hei
ght
3/16" (5)
Frenchwood® Transom
Frenchwood® Hinged Patio Door
Optional Andersen® trim strip set in continuous bead of sealant each side
Optional Andersen®2” (51)wood casing
OptionalAndersen®non-reinforced aluminumjoining strip
3/4"(19)
3/4" (19)
1"(25)
1"(25)
Unit Dimension Width Unit Dimension Width
Frenchwood®Hinged Patio Door
Frenchwood®Sidelight or Transom
Optional Andersen® trim strip set in continuous bead of sealant each side
Optional Andersen®2-3/8" (60) wood casing
Optional Andersen®LVL reinforced joining strip
Unit
Dim
ensi
on H
eigh
tUn
it Di
men
sion
Hei
ght
3/4" (19)3/4"(19)
1" (25)
1" (25)
Frenchwood® Transom
Frenchwood® Hinged Patio Door
Optional Andersen® trim strip set in continuous bead of sealant each side
Optional Andersen®2-3/8" (60)wood casing
Optional Andersen®LVL reinforced joining strip
A R C H I T E C T U R A L D E T A I L F I L E 10-17 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Andersen 2" Support Mullion
Support JoiningScale 3" = 1'-0" (1:4)
Joining Details
Andersen 2" Support Transom
1"(25)
1"(25)
2"(51)
2" (51)
Structure by others
Optional Andersen®
2" support mullionwood filler
Optional Andersen®
2" support mulliontrim strip set in continuous bead of sealant each side
Optional Andersen®extension jambs
Unit
Dim
ensi
on H
eigh
tUn
it Di
men
sion
Hei
ght
2" (5
1)Frenchwood® Transom
Frenchwood® Hinged Patio Door
Structureby others
OptionalAndersen®extension jambs
OptionalAndersen®
2" supportmullionwood filler
OptionalAndersen®
2" supportmulliontrim strip set in continuousbead of sealant eachside
Joining Compatibilty Many Andersen® units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Andersen® Product Guide for Professionals, in Andersen Window Studio® software, and by visiting andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified.
A R C H I T E C T U R A L D E T A I L F I L E10-18 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionBrick Veneer / 2 x 6" Metal Stud Framing
Vertical SectionWood Siding / 2 x 4 Wood Stud Framing
3/4"(19)
3/8"(10)
Roug
h Op
enin
g He
ight
Unit
Dim
ensi
on H
eigh
t
Unit
Dim
. Wid
th
Installation flangeat head and jambs
Optional Andersen®
metal sill support
Optional Andersen®
oak or maple threshold
Head
Jamb
Sill
Optional Andersen®
insect screen
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Removeinstallationflange at head and jambs
Optional Andersen®
oak or maple threshold
Optional Andersen®
insect screen
Head
Jamb
Sill
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper
width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 10-19 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionBrick / Concrete Masonr y Unit (CMU)
Vertical SectionE.I.F.S. / Concrete Masonr y Unit (CMU)
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Installationflange at headand jambs
Membrane flashingover installationflange(by others)
Optional Andersen® insectscreen
Optional Andersen®
oak or maplethreshold
Head
Jamb
Sill
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
Optional Andersen®
insectscreen
Optional Andersen®
auxiliarycasing
Optional Andersen®
oak or maple threshold
Head
Jamb
Sill
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper
width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E10-20 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionStucco / Concrete Masonr y Unit (CMU) Inset Door
Vertical SectionExisting Stud Wall
3/8"(10)
Unit
Dim
. Wid
th
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
1-3/16" (30)
Installationflange at head and jambs
Optional Andersen®
insect screen
Optional Andersen®
auxiliary casing
Optional Andersen®
oak or maplethreshold
Head
Jamb
Sill
3/8"(10)
Unit
Dim
ensi
on H
eigh
t
Unit
Dim
. Wid
th
Roug
h Op
enin
g He
ight
Optional Andersen®
vinyl trim board
Optional Andersen®
rigid vinyl3/4" (19) "h" channel
Existing frame wall
Installationflangeat headand jambs
Optional Andersen®
insect screen(hinged shown)
Optional Andersen®
oak or maplethreshold
Optional Andersen®
metal sill support
Sill
Head
Jamb
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper
width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.
A R C H I T E C T U R A L D E T A I L F I L E 10-21 R E V . 0 3 / 0 5
F r e n c h w o o d ® H i n g e d P a t i o D o o r s
Wall TypesScale 1-1/2" = 1'-0" (1:8)
Suggested Product Applications
Vertical SectionExisting Masonr y Wall
Unit
Dim
ensi
on H
eigh
t
Roug
h Op
enin
g He
ight
3/8"(10)
Unit
Dim
. Wid
th
Optional Andersen®
vinyl trimboard
Optional Andersen®
rigid vinyl3/4" (19) "h" channel
Installationflangeat headand jambs
Optional Andersen®
insect screen(hinged shown)
Optional Andersen®
oak or maplethreshold
Jamb
Sill
Head
Importance of Proper InstallationProper installation and maintenance of Andersen® products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer.
Construction by OthersAndersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others.
NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper
width of sealant joint around the perimeter of the window.
NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange.