Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

15
Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL

Transcript of Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

Page 1: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

Fragment Mass Analyzer upgradesand

X-array status

Darek Seweryniak, ANL

Page 2: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

2

High beam intensity and efficiency updates

FMA upgrades– New beam dump– New entrance quadrupole doublet

Implantation station upgrades– 160X160 DSSD– Digital electronics

X-array status– New frame– 5th super clover

Page 3: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

3

New beam dump

Unreacted beam strikes the inside of the anode and the tank near the exit from the tank relatively close to the electrodes

Move the interaction area away from the electrodes Avoid dumping the beam on the anode Requires significant modification of the tank

Page 4: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

4

Before…

After…

B. DiGiovine

Page 5: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

5

New entrance quads

1st quad shorter with higher fields similar concept was used in EMMA Increase the solid angle from 8 msr to 12 msr at

relatively short distances between target and FMA

Page 6: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

6

FMA at 293 mm – stand-alone

OLD:y=0.038 rad

y,max=0.0401 rad

Qx=0.046 radx,max=0.0495 rad

NEW:y=0.060 rad

y,max=0.0634 rad

Qx=0.059 radx,max=0.0591 rad

=7.4 msr =11.8 msr

Page 7: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

7

FMA implantation station

Ge clovers 160X160 DSSD

Large area Si

Si/PiN box

plastic dets

Page 8: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

8

New high-granularity DSSD

160x160 strips64mm x 64 mm100, 140 m thick

Page 9: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

9

160X160 DSSD in-beam test

ln t

E

109Te/5s

109I/100s

Page 10: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

10

Digital DAQ for DSSD

IOC 4XDIG IOC 4XDIG IOC 4XDIG

IOC master TTC + 2 router TTC

CPU Diskarray

CPU

NETWORK switch

Based on the GRETINA DAQ (320 channels) Synchronization with analog DAQ through a common clock signal We have just started implementing 160-channel DAQ.

Page 11: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

11

New X-array frameStephen Heimsatz

5 clover detectors in a box geometry 64x64 mm, 160x160 DSSD

Page 12: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

12

X-array

Page 13: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

13

X-array frame features

Frame horizontal movement (rails) and vertical adjustment

In-out detector adjustment All electronics on board but ADC Laptop for controlling and monitoring “portable” (transportation mode) Auto LN2 system on board (to be implemented)

Page 14: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

14

Plastic beta detectors

FMA

Identify DSSD pixel beta originated from Thin plastic scintillators with photodiodes Identify beta hitting a Ge detetector Full beta energy in Ge (high energy betas)

plastic

Ge

Ge

plastic

Ge

Page 15: Fragment Mass Analyzer upgrades and X-array status Darek Seweryniak, ANL.

15

Thank you!