FPA-1000-UL Compact Fire Panel...FPA-1000-UL Compact Fire Panel Site Data | en 7 Bosch Security...
Transcript of FPA-1000-UL Compact Fire Panel...FPA-1000-UL Compact Fire Panel Site Data | en 7 Bosch Security...
FPA-1000-UL Compact Fire Panel
en Program Record Sheet
FPA-1000-UL Compact Fire Panel Table of Contents | en 3
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
Table of Contents
1 Account Information 4
2 Security 5
3 Site Data 6
4 SLC Configuration 8
5 Mainboard 12
6 Option Bus 13
7 Reporting 17
8 Zones 19
9 Testing 21
4 en | Account Information FPA-1000-UL Compact Fire Panel
1 Account Information
Account:
Date:
Name:
Address:
Panel Phone Number:
Contact Phone Number:
Contact Person:
Comments:
Panel Location:
Notes:
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel Security | en 5
2 SecurityFill in the Security Customer Programming in Table 4.1:– insert the user PIN codes of your personnel preference for the different authority levels,– mark the selected PIN assignment.The Web operator PIN only allows for viewing the FPA-1000-UL Web pages. The authority level for programming is fixed to Level 3.
Table 2.1 Security Customer Programming
Table 2.2 Security Default Settings
Customer Programming
Authority Level User PIN PIN Assignment
RSD History Walk Test Test Date/Time Bypass
Web Operator 1) - - - - - -
Level 1 No PIN
Level 1RSD - - - - -
Level 2
Level 3
1) The Web Operator user name is “operator” (case sensitive and not changeable).
- Not programmable
RSD Reset, Silence, Drill
Default Settings
Authority Level User PIN Default PIN assignment
RSD History Walk Test Test Date/Time Bypass
Web Operator 1) 0000 - - - - - -
Level 1 No PIN X X X
Level 1RSD 1111 - - - - -
Level 2 2222 X X X
Level 3 3333
1) The Web Operator user name is “operator” (case sensitive and not changeable).
- Not programmable
X Default assignment
RSD Reset, Silence, Drill
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
6 en | Site Data FPA-1000-UL Compact Fire Panel
3 Site DataFill in the Customer Programming column:– insert customer entries (for example, device label or value),– mark selected setting option, or– place a check mark in the box, if applicable.
Basic Settings Customer Programming Default Setting
Banner (1. line) BOSCH
Banner (2. line) Fire System
Language English
Panel IP address 192.168.1.30
Gateway 192.168.1.1
Netmask 255.255.255.0
Printer IP address [empty]
Printer IP port 21
Printer FTP user [empty]
Printer FTP password [empty]
System Settings, Time Format, Units and Silence
Customer Programming Default Setting
Supervisory latching
External power supply
Time format 12 h | 24 h 12 h
Unit format °F, ft | °C, m °F, ft
Silence Audible only | Audible and visual Audible only
Enable silence
Enable drill
Level needed Customer Programming Default Setting
Web Operator 0000 (user name “operator”)
Level 1 no PIN (History, Date/time)
Level 2 PIN (maintenance) 2222 (Walk test, Test, Bypass)
Level 3 PIN (programming) 3333
PIN for reset/silence/drill 1111, not activated
Time schedule Customer Programming Default Setting
Enable daylight saving
Start: ________ Sunday in _________________End: _________ Sunday in _________________
Start: 1st Sunday in MarchEnd: 3rd Sunday in October
Detector day sensitivity enableMo Tu We Th Fr Sa Su Mo Tu We Th Fr Sa Su
Start ________________ , End _______________ Start 7:00 am, End 5:30 pm
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel Site Data | en 7
Timer settings Customer Programming Default Setting
Day mode No delay | PAS | Pre-signal No delay
Investigation time __________ s (60 - 180 seconds) 180 s
Alarm verification delay __________ s (60 - 180 seconds) 60 s
AC failure delay __________ h (0 - 6 hours) 3 h
Waterflow delay __________ s Waterflow silenceable 90 s Waterflow silenceable
Auto silence delay _________ min Enable 10 min Enable
Silence inhibit _________ min (0 - 5 minutes) 0 min
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
8 en | SLC Configuration FPA-1000-UL Compact Fire Panel
4 SLC ConfigurationSLC CircuitsTable 4.2 shows the default configuration of the SLC circuits. The first FPE-1000-SLC (SLC 1) is standard equipment. The second FPE-1000-SLC Plug-in Module is optional.Fill in Table 4.1 according to your application:– insert customer entries (for example, device label or value),– mark selected setting option, or– place a check mark in the box, if applicable.
Table 4.1 SLC Circuit Customer Programming
Table 4.2 SLC Circuit Default Configuration
SLC DevicesEach device on the SLC circuit has a unique address and can be configured individually. Table 4.4 shows the default settings for all compatible SLC devices.Photocopy the blank Table 4.5 on page 11 for Addresses 1 to 255. Insert customer entries (for example device label or value) and place a check mark in the box if applicable. When filling in the Point Type, Delay Mode and NAC Pattern columns, refer to Table 4.3 for possible SLC configuration options.
Table 4.3 SLC Configuration Options
Customer Programming SLC Circuits
SLC Address Installed Topology Label Bypass Option
SLC 1 0 (fixed) Installed Class A | 1 x class B | 2 x class B Bypassed
SLC 2 0 (fixed) Installed Class A | 1 x class B | 2 x class B Bypassed
Default Settings SLC Circuits
SLC Address Installed Topology Label Bypass Option
SLC 1 0 (fixed) Installed 2 x class B [empty] Bypassed
SLC 2 0 (fixed) Installed 2 x class B [empty] Bypassed
Point Type Delay Option NAC Pattern
Fire Automatic No = No Delay Steady
Fire Manual AV = Alarm Verification Pulsing
Waterflow PAS/Pre = Positive Alarm Sequence/Pre-signal Temporal Code 3
Waterflow with Delay PAS/AV = PAS (day) / AV (night)
Supervisory
Gas Alarm
Generic
Trouble
AC Failure
Battery Failure
Reset
Silence
Drill
Acknowledge
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel SLC Configuration | en 9
Default Settings
Address Device Type Zones Set point Delay Mode NAC Pattern
Status
Options 2)Point Type Device Label Day Sensitivity 1) Input Type
Additional Settings
FAD-325 0 - 0 - 0 - 0 - 0 2.50 %/ft (8.20 %/m) No delay n. a. Bypassed
Fire automatic [empty] 2.50 %/ft (8.20 %/m) n. a. -
FAH-325 0 - 0 - 0 - 0 - 0 1.35 °F (57 °C) No delay n. a. Bypassed
Fire automatic [empty] 1.35 °F (57 °C) n. a. -
FAI-325 0 - 0 - 0 - 0 - 0 0.85 %/ft (2.80 %/m) No delay n. a. Bypassed
Fire automatic [empty] 0.85 %/ft (2.80 %/m) n. a. -
FAD-325-DH 0 - 0 - 0 - 0 - 0 2.00 %/ft (6.55 %/m) No delay n. a. Bypassed
Fire automatic [empty] 2.00 %/ft (6.55 %/m) n. a. -
Duct relay Installed: Disabled, global alarm Zone (129) assigned, Relay label [empty], Relay bypassed: Disabled
FLM-325-I 3) 0 - 0 - 0 - 0 - 0 n. a. n. a. n. a. Bypassed
Fire alarm manual [empty] n. a. NO with EOL -
FLM-325-CZM4 0 - 0 - 0 - 0 - 0 n. a. No delay n. a. Bypassed
Fire automatic [empty] n. a. n. a. -
FLM-325-2I4 0 - 0 - 0 - 0 - 0 n. a. n. a. n. a. Bypassed
Fire automatic [empty] n. a. NO with EOL -
Default settings apply to Input 1 and Input 2.
FLM-325-2R4 129 - 0 - 0 - 0 - 0 n. a. n. a. n. a. Bypassed
n. a. [empty] n. a. n. a. Drillable
Default settings apply to Relay 1 and Relay 2.
1) The day sensitivity has to be enabled by programming the time schedule (refer to Section 3 Site Data on page 6).
2) Add drillable or silenceable if applicable.3) Applies to the 3 variants FLM-325-I4, FLM-325-IS, and FLM-325-IW.
An Analog Manual Station FMM-325A/FMM-325A-D communicates with the FACP polling circuit through its addressable FLM-325-I Contact Monitor.
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
10 en | SLC Configuration FPA-1000-UL Compact Fire Panel
Table 4.4 SLC Devices Default Configuration
D328A 129 - 0 - 0 - 0 - 0 n. a. n. a. n. a. Bypassed
n. a. [empty] n. a. n. a. Drillable
FLM-325-N4 129 - 0 - 0 - 0 - 0 n. a. n. a. Steady Bypassed
n. a. [empty] n. a. n. a. Silenceable
FAA-325-B6S 129 - 0 - 0 - 0 - 0 n. a. n. a. Temporal Code 3
Bypassed
n. a. [empty] n. a. n. a. Silenceable
Default Settings
Address Device Type Zones Set point Delay Mode NAC Pattern
Status
Options 2)Point Type Device Label Day Sensitivity 1) Input Type
Additional Settings
1) The day sensitivity has to be enabled by programming the time schedule (refer to Section 3 Site Data on page 6).
2) Add drillable or silenceable if applicable.3) Applies to the 3 variants FLM-325-I4, FLM-325-IS, and FLM-325-IW.
An Analog Manual Station FMM-325A/FMM-325A-D communicates with the FACP polling circuit through its addressable FLM-325-I Contact Monitor.
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel SLC Configuration | en 11
Table 4.5 SLC Devices Customer Programming
Customer Programming
Address Device Type Zones Set point Delay Mode NAC Pattern Status
Options 2)Point Type Device Label Day Sensitivity 1) Input Type
Additional Settings
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
__ - __ - __ - __- __ Bypassed
1) The day sensitivity has to be enabled by programming the time schedule (refer to Section 3 Site Data on page 6.2) Add drillable or silenceable if applicable.
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
12 en | Mainboard FPA-1000-UL Compact Fire Panel
5 MainboardFill in the Customer Programming columns:– insert customer entries (for example, device label or value), or– place a check mark in the box, if applicable.
Relays Customer Programming
Relay type Zones Drillable Bypassed Energized in normal
Label
Relay 1 ALM | TRB | SPVR __ - __ - __ - __ - __
Relay 2 ALM | TRB | SPVR __ - __ - __ - __ - __
Relay 3 ALM | TRB | SPVR __ - __ - __ - __ - __
Relays Default Setting
Relay type Zones Drillable Bypassed Energized in normal
Label
Relay 1 Alarm (ALM) 129 only Mainboard relay 1
Relay 2 Trouble (TRB) 130 only Mainboard relay 2
Relay 3 Supervisory (SPVR) 131 only Mainboard relay 3
NACs Customer Programming
Pattern Zones Silence. Bypassed Label
NAC 1
NAC 2
NACs Default Setting
Pattern Zones Silence. Bypassed Label
NAC 1 Steady 129- Mainboard NAC 1
NAC 2 Steady 129- Mainboard NAC 2
Silence. = Silenceable
City Tie Customer Programming
City Tie board installed
Configuration Bypassed Label
1
2
City Tie Default Setting
City Tie board installed
Configuration Bypassed Label
1 Alarm City Tie 1
2 Supervisory City Tie 2
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel Option Bus | en 13
6 Option BusLED AnnunciatorsFill in the following tables for the LED Annunciators:– insert customer entries (for example, device label or value), or– place a check mark in the box, if applicable.By default, all check marks are empty.
Table 6.1 LED Annunciators Customer Programming
LCD Annunciators/Command CentersFill in the following tables for the FMR-1000-RCMD Remote Command Center or FMR-1000-RA Remote Annunciator:– insert customer entries (for example, device label or value), or– place a check mark in the box, if applicable.By default, all check marks are empty.
Table 6.2 LCD Annunciators /Command Centers Customer Programming
Customer Programming
Address LED Annunciators
D7030X D7032
1 Zone 1-8 Zone 9-16
2 Zone 17-24 Zone 25-32
3 Zone 33-40 Zone 41-48
4 Zone 49-56 Zone 57-64
Repeat zone 1-64
5 Zone 65-72 Zone 73-80
6 Zone 81-88 Zone 89-96
7 Zone 97-104 Zone 105-112
8 Zone 113-120 Zone 121-128
Customer Programming
LCD Annunciators/Command Centers
Address FMR-1000 Address FMR-1000
16 Annunciator 1 20 Annunciator 5
17 Annunciator 2 21 Annunciator 6
18 Annunciator 3 22 Annunciator 7
19 Annunciator 4 23 Annunciator 8
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
14 en | Option Bus FPA-1000-UL Compact Fire Panel
Output ModulesFill in Table 6.3 and Table 6.4 for the Output Modules:– insert customer entries (for example, device label or value), or– place a check mark in the box, if applicable.By default, all check marks are empty. For each of the output, the first zone is assigned to the global alarm zone 129 by default.
Table 6.3 Output Module 1@9 Customer Programming
Table 6.4 Output Module 2@10 Customer Programming
Customer Programming
D7035 Octal Relay Module or D7048 Octal Driver Module
Output Module 1@9
Module 1 Installed
Address 9 Out Zones Drillable Bypassed Energized in normal
Label
1 ___ - ___ - ___ - ___ - ___
2 ___ - ___ - ___ - ___ - ___
3 ___ - ___ - ___ - ___ - ___
4 ___ - ___ - ___ - ___ - ___
5 ___ - ___ - ___ - ___ - ___
6 ___ - ___ - ___ - ___ - ___
7 ___ - ___ - ___ - ___ - ___
8 ___ - ___ - ___ - ___ - ___
Out = Output
Customer Programming
D7035 Octal Relay Module or D7048 Octal Driver Module
Output Module 2@10
Module 2 Installed
Address 10 Out Zones Drillable Bypassed Energized in normal
Label
1 ___ - ___ - ___ - ___ - ___
2 ___ - ___ - ___ - ___ - ___
3 ___ - ___ - ___ - ___ - ___
4 ___ - ___ - ___ - ___ - ___
5 ___ - ___ - ___ - ___ - ___
6 ___ - ___ - ___ - ___ - ___
7 ___ - ___ - ___ - ___ - ___
8 ___ - ___ - ___ - ___ - ___
Out = Output
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel Option Bus | en 15
Remote NAC Power SupplyFill in Table 6.5 for the Remote NAC Power Supply:– insert customer entries (for example, device label or value), or– place a check mark in the box, if applicable.
Table 6.5 Remote NAC Power Supply Customer Programming
Customer Programming
FPP-RNAC-8A-4C Remote NAC Power Supply
RNAC Module 1@11
RNAC 1 Installed
Address 11 Out Zones Pattern Silence. Bypassed Label
1 ___ - ___ - ___ - ___ - ___
2 ___ - ___ - ___ - ___ - ___
3 ___ - ___ - ___ - ___ - ___
4 ___ - ___ - ___ - ___ - ___
RNAC Module 1@12
RNAC 2 Installed
Address 12 Out Zones Pattern Silence. Bypassed Label
1 ___ - ___ - ___ - ___ - ___
2 ___ - ___ - ___ - ___ - ___
3 ___ - ___ - ___ - ___ - ___
4 ___ - ___ - ___ - ___ - ___
RNAC Module 1@13
RNAC 3 Installed
Address 13 Out Zones Pattern Silence. Bypassed Label
1 ___ - ___ - ___ - ___ - ___
2 ___ - ___ - ___ - ___ - ___
3 ___ - ___ - ___ - ___ - ___
4 ___ - ___ - ___ - ___ - ___
RNAC Module 1@14
RNAC 4 Installed
Address 14 Out Zones Pattern Silence. Bypassed Label
1 ___ - ___ - ___ - ___ - ___
2 ___ - ___ - ___ - ___ - ___
3 ___ - ___ - ___ - ___ - ___
4 ___ - ___ - ___ - ___ - ___
Out = OutputSilence. = Silenceable
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
16 en | Option Bus FPA-1000-UL Compact Fire Panel
Table 6.6 Remote NAC Power Supply Default Setting
Default Settng
FPP-RNAC-8A-4C Remote NAC Power Supply
RNAC Module 1@11
RNAC 1 Installed
Address 11 Out Zones Pattern Silence. Bypassed Label
1 129 - ___ - ___ - ___ - ___ Steady
2 129 - ___ - ___ - ___ - ___ Steady
3 129 - ___ - ___ - ___ - ___ Steady
4 129 - ___ - ___ - ___ - ___ Steady
RNAC Module 1@12
RNAC 2 Installed
Address 12 Out Zones Pattern Silence. Bypassed Label
1 129 - ___ - ___ - ___ - ___ Steady
2 129 - ___ - ___ - ___ - ___ Steady
3 129 - ___ - ___ - ___ - ___ Steady
4 129 - ___ - ___ - ___ - ___ Steady
RNAC Module 1@13
RNAC 3 Installed
Address 13 Out Zones Pattern Silence. Bypassed Label
1 129 - ___ - ___ - ___ - ___ Steady
2 129 - ___ - ___ - ___ - ___ Steady
3 129 - ___ - ___ - ___ - ___ Steady
4 129 - ___ - ___ - ___ - ___ Steady
RNAC Module 1@14
RNAC 4 Installed
Address 14 Out Zones Pattern Silence. Bypassed Label
1 129 - ___ - ___ - ___ - ___ Steady
2 129 - ___ - ___ - ___ - ___ Steady
3 129 - ___ - ___ - ___ - ___ Steady
4 129 - ___ - ___ - ___ - ___ Steady
Out = OutputSilence. = Silenceable
Address 15 is not used.
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel Reporting | en 17
7 ReportingFill in the Customer Programming column:– insert customer entries (for example, device label or value),– mark selected setting option, or– place a check mark in the box, if applicable.
Primary Account
Customer Programming Default Setting
Account number ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ [empty]
Reporting format SIA 300 | Contact ID | Modem IIIa2 SIA 300
Auto test time 2:00 am
Auto test interval Disable | 4 hours | 12 hours | 24 hours | 7 days | 28 days
24 hours
Max. attempts _________ (5 - 10) 10
Selection PSTN/IP/Disable PSTN | IP | Disable PSTN
PSTN Customer Programming Default Setting
Phone number [empty]
IP Reporting Conettix Customer Programming Default Setting
Receiver IP address [empty]
Port number 7700
Anti-replay
Polling interval _________ seconds (30 - 255 s) 75 s
Acknowledge wait time _________ seconds (15 - 255 s) 30 s
Secondary Account
Customer Programming Default Setting
Account number ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ [empty]
Reporting format SIA 300 | Contact ID | Modem IIIa2 SIA 300
Auto test time 2:00 am
Auto test interval Disable | 4 hours | 12 hours | 24 hours | 7 days | 28 days
24 hours
Max. attempts _________ (5 - 10) 10
Selection PSTN/IP/Disable PSTN | IP | Disable PSTN
PSTN Customer Programming Default Setting
Phone number [empty]
IP Reporting Conettix Customer Programming Default Setting
Receiver IP address
Port number 7700
Anti replay
Polling interval _________ seconds (30 - 255 s) 75 s
Acknowledge wait time _________ seconds (15 - 255 s) 30 s
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
18 en | Reporting FPA-1000-UL Compact Fire Panel
PSTN Communicator Settings Customer Programming Default Setting
Dialing type DTMF | Puls | Auto DTMF
Monitor line 1
Monitor line 2
Redial interval _________ seconds (1 to 60 s 10 s
Reporting Customer Programming Default Setting
Fire Alarm Secondary as backup
Supervisory Secondary as backup
Fire restoral Secondary as backup
Supervisory restoral Secondary as backup
Trouble and restoral Secondary as backup
Walk test Secondary as backup
Silence Secondary as backup
Reset Secondary as backup
Fire drill Secondary as backup
Programming options are:– Primary account only– Secondary account only– Primary and secondary account– Secondary account as backup– No report
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel Zones | en 19
8 ZonesGlobal ZonesZones 129 to 135 are global zones and hard-coded to pre-assigned conditions (refer to Table 8.1). Fill in the Customer Programming column in Table 8.1:– insert customer entries for NAC pattern,– place a check mark in the box for Networked, if applicable.
Table 8.1 Global Zones
Software ZonesZones 1 to 128 are software zones and individually programmable. Table 8.2 shows an example for a software zone programming.Photocopy the blank Table 8.3 on page 20 for software zones 1 to 128. Fill in the columns in Table 8.3:– insert customer entries for zone number, label, pattern, and counting zone assignment,– place a check mark in the box for Bypassed and Networked, if applicable.
Table 8.2 Software Zone Programming
Global Zones (Fixed) Customer Programming Default Setting
No. Zone Text (read only) NAC Pattern* Networked NAC Pattern* Networked
129 Global Fire Alarm Default
130 Global Trouble Default
131 Global Supervsr Default
132 Global Alm Verify Default
133 Global Pre-signal Default
134 Global PAS Default
135 Global Reset Default
135 Global Gas Alarm Default
* Default is the NAC pattern chosen in the Mainboard outputs or the Option Bus section (refer to Section 5 Mainboard on page 12, respectively Section 6 Option Bus on page 13).Programming options are:– Default– Steady– Pulsing– Temporal Code 3
Default Settings
Software Zones (Programmable 1-128)
Index Zone No. Label Pattern Counting Bypassed Networked
0 1 [empty] Default 1
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
20 en | Zones FPA-1000-UL Compact Fire Panel
Table 8.3 Customer Programming: Software Zones
Customer Programming
Software Zones (Programmable 1-128)
Index Zone No. Label Pattern Counting Bypassed Networked
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.
FPA-1000-UL Compact Fire Panel Testing | en 21
9 Testing
Walk Test Customer Programming Default Setting
Walk test area Panelwide | SLC 1 | SLC 2 | Zones __ __ __ __ __
Panelwide
Audible options Audible long | Audible short | Silent Silent
Bosch Security Systems, Inc. Program Record Sheet F.01U.075.637 | 2.0 | 2009.04
22 en | Testing FPA-1000-UL Compact Fire Panel
F.01U.075.637 | 2.0 | 2009.04 Program Record Sheet Bosch Security Systems, Inc.