FP-A08E15-OD01_DS_0-0-5.pdf

download FP-A08E15-OD01_DS_0-0-5.pdf

of 2

Transcript of FP-A08E15-OD01_DS_0-0-5.pdf

  • 8/11/2019 FP-A08E15-OD01_DS_0-0-5.pdf

    1/2

    Phase Filter LTE800/UMTS900/GSM900FP-A08E15-OD01

    Information contained in this document is subject to confirmation at time of ordering.http://www.comba-telecom.com

    Issued: June.13

    Control: 0-0-5

    1/2

    Technical Specifications

    Electrical

    Pass Band MHzRX: 880 895/839.5 847/905-915

    TX: 925 940/798.5 806

    Ports IsolationPort 1 to Port 2 (TX) dB 25

    Port 3 to Port 4 (RX) dB

    25

    Insertion Losses

    RX dB

    0.5 (0.4 typical)@880-895MHz

    0.5 (0.4 typical)@839.5-847MHz

    0.7 (0.5 typical)@905-915MHz

    TX dBCoupling value 3.1

    Insertion loss 1.2

    Amplitude

    Differences

    Port 1 to Port 2 (RX) 10%@880-895MHz

    Port 3 to Port 4 (TX) 10%

    Phase Difference

    Port1Port3(TX):Port1Port 4(TX)

    5max@925-940MHz

    [email protected]

    Phase difference

    Port2Port3(TX):Port2Port 4(TX)1805max@925-940MHz

    VSWR

    Port 2 (TX)1.25@925-940MHz

    [email protected]

    Port 1 (TX) 1.25@925-940 [email protected]

    Port 3 (RX)1.25@880-895MHz

    [email protected]

    Port 4 (RX)1.25@880-895MHz

    1.25@905-915MHz

    Power Handling Continuous W 150

    Intermodulation Products dBc -150@2x43dBm

    Impedance 50

    Mechanical &EnvironmentalDimension (LxWxH excluding mountingbrackets)

    mm (in) 400x210x55(15.7x8.3x2.2)

    Weight(Approximate) kg (lb) 7 (15.4)

    RF Connectors DIN 7/16 female

    Mounting Kit Pole (clamps included for 70-110mm)Operating Temperature Range oC -40 to +65

    Operational Humidity %

  • 8/11/2019 FP-A08E15-OD01_DS_0-0-5.pdf

    2/2

    Phase Filter LTE800/UMTS900/GSM900FP-A08E15-OD01

    Information contained in this document is subject to confirmation at time of ordering.http://www.comba-telecom.com

    Issued: June.13

    Control: 0-0-5

    2/2

    Outline Drawing