FOUR - POOL - Package Pool Dehumidifier

1- General Characteristics

1.1 Working principle

1.2. In-plant equipment placement plan

1.3. Example working scenarios

2. Technical features and Equipment

2.1. Tape structure

2.2. Plant base

2.3. Fans

2.4. Motors

2.5. Heating and Cooling Equipment

2.6. Dampers

2.7. Filters

2.8 Heat recovery cells

2.9. Power and Control Panel

3. Electric Panel and Automation

4. Plant sizes and capacity chart

Table of Contents

FOUR - POOL - Package Pool Dehumidifier

3

If partial pressure of water vapor contained in the ambient air is lower than the

saturation pressure, evaporation occurs over the pool water’s surface. It is

possible to see the evaporation in large amount of water at indoor swimming

pools. Thus, the amount of moisture in the air rises to inappropriate level.

Depending on the high level of moisture in the building, sweating occurs at

windows and walls thus it results formation of corrosion and fungus in

structure components. Besides damaged of structural components in the

building, it lowers the blood circulation in people and results lower capacity in

sportive activities. According to VDI 2089/1, the humidity in indoor swimming

pools is ranked between 40 -64 %.

As a conclusion removing these adverse effects can be made by keeping the

humidity values appropriate by the humidifier.

The advantages of FourSeason Four-Pool series Swimming pool Humidifier

equipment:

• Absolute humidity control

• The necessary amount of fresh air

• Air flow control

• Mechanical cooling

The features such as the comfort and energy saving are kept at the highest

level in all operating process.

46% of energy saving is spent for heating and ventilation at indoor swimming

pools.

In scope of these applications, very suitable temperatures are revealed for heat

recovery. By virtue of using the heat pomp and recycling device during the

dehumidification process in ventilation, the value of heat recovery i.e.

coefficient of performance (COP value) in return air of swimming pool is

between 4 and 5.

Maximumcomfort,Maximumenergysaving

1. GENERAL FEATURES

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

Micro processingfull automatic

control

4

1.1. Working Principle

FourSeason Four-Pool series Pool Dehumidifier is manufactured with fullautomatic control system with micro-processor. Thus, all components on equipment are able to be controlled to guarantee the result.As an example, while the device is idle and working without dehumidification function, it provides air circulation inside of the pool. When humidity sensor exceeds the setting value, it passes to dehumidification mode. While it is working at idle position, fresh air and exhaust dampers are turned off since there is nobody in the pool so no need to have fresh air. Heat pump comes into operation and it starts dehumidification process. Using by-pass dampers, it is mixed with dehumidified air by cooling with return air. This process continues until actual humidity value reaches to set value of humidity sensor..In active use, fresh air and exhaust dampers open. By pass damper 14 is turned off.

1. General Features

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

5

1. G4 Filter

2. Extractor Fan

3. Diffuser

4. Evaporator

5. Demister

6. Exhaust damper

7. Fresh air damper

1.2. In-plant Equipment Placement Plan

1. G4 Filter

2. Extractor Fan

3. Diffuser

4. Evaporator

5. Demister

6. Exhaust damper

7. Fresh air damper

1.2. In-plant Equipment Placement Plan

Perfectsolutions to uniqueplaces.

FRESH AIRSUPPLY AIR

RETURN AIREXHAUST AIR HE

AT

P

IP

E

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

6

Scenario 1: WINTER- NIGHT

It is ideally preferred at nights during the winter months. Since there is no user in the pool, the fresh air and exhaust dampers are closed.. The mixture dampers are completely turned on. It runs with internal air by 100%. The compressor comes in and it fulfils the task of dehumidifying. The humidly rate of cooled air for dehumidifying is kept at fixed value thus increased temperature while passing over the condenser.

Scenario 2: WINTER- DAY

It is ideally preferred during the active pool hours in winter months when the outside temperature is low. The suction air leaves a part of heat while passing over the heating pipe. The compressor comes in and it fulfils the task of dehumidifying for energy saving, a certain amount of exhaust air is mixed with fresh air. Heat that is accumulated in heating pipe is rolled back. Heater battery brings the blowing temperature which has been lowered after dehumidifying process, to comfort value.

Scenario 3: SUMMER

It is ideally preferred in cases when the outside temperature is higher than the inside temperature of the pool. In such cases, the heating pipe and heating pumps are disabled. The humidity is kept constant by 100% fresh air. The compressor does not start in.

1. General Features 1.3. Example Study Scenarios

SUPPLY AIR RETURN AIR

SUPPLY AIR RETURN AIR

SUPPLY AIR RETURN AIR

HE

AT

P

IPE

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

7

2. Technical Specifications and Equipment

2.1.Cassette structure • The frame was manufactured with 6063 extruded aluminum profile and

painted with RAL9002 epoxy electrostatic powder paint .

• It has 50 mm panel structure. The inner and outer surfaces are painted with

moisture resistant RAL9002 epoxy electrostatic powder paint.

Upon request of the customer, the inner panels can be manufactured from

AlS1304 quality stainless steel sheet. It is filled with rock wool with weight of 70

kg/m3 in thickness of 50 mm. It features preventive action against the thermal

bridge at interval profiles. It is fed with rock wool.

• The inner surface of equipment is completely smooth without any recess, bulge

so it is easily cleaned by preventing any dust or dirt build-up.

• The holes where the cables passed through and the measurement devices are

mounted are air tight.

• For piping, a special blind cell is produced in device.

2.2. Equipment base• The base of the equipment is manufactured from galvanized sheet with

thickness of 2 mm. It is painted with Moisture resistant RAL9002 Epoxy

electrostatic powder paint.

• In order to keep the level of corrosion resistance, bolt-nut is used in mounting

of base.

• Upon customer’s demand, a special vibration wedge is attached thus both

necessity of any additional base and the vibration of the machine are prevented.

2.3. Backgrounds • In order to prevent the vibration, fan + motor group is mounted to the

equipment with appropriate isolators and flexible connection. Spring isolators are

selected in capacity to carry the static and dynamic loads of fan +motor group

and with high vibration isolation efficiency.

• Spring isolators are coated with corrosion-resistant coating.

• Spring isolators are locked with central locking mechanism to prevent the

action of fan motor group during the transport. Equipment has a warning label,

which is stating that the locking mechanism of spring isolator should be removed

before operating the device.

2.4. Engines • Three-phase squirrel cage-rotor

• Asynchronous electric motors with IP56 protection class

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

8

2. Technical features and Equipment

2.5. Heating and Cooling Equipment

• Serpentines are Eurovent certified.

• Serpentines are manufactured from copper pipe and aluminum wings.

• Cassette is made of galvanized or stainless sheet material.

• All serpentines have one discharging and one air cap.

• Serpentines tested under pressure of at least 20 bar. If necessary, test can

be done under pressure of 30 bar.

• Collectors used in serpentines are made of copper pipe.

• Heater and cooler Assembly serpentine sheets are slide-out so they can

easily be removed for cleaning and maintenance.

• Any risk of short circuit because of air passing through serpentine is prevent-

ed by using special by—pass sheets.

• On hot and cold water serpentines, the water inlet placed below bottom and

the water outlet placed above top as reverse flow to rise heat transfer rate

between air and water.

• A dual inclined condensing pan is placed below cooling serpentine and accu-

mulated water is discharged through the drainage pipe.

• If demister is used, the type of demister of which the wing is made of PVC

material resistant against the temperature up to 90 C degree is selected.

• The siphon made of suitable material given with the equipment is able to

prevent the air to release or the air to come inside through the drainage pipe

according to the pressure in cooler serpentine cell ( negative or positive).

• A rubber badge is attached to the pipe in order to prevent any possible

condensation and air leakage between water inlet-outlet pipes and device

cassette in heating and cooling coil.

COMPRESSORS

• Scroll type compressors are used in FourSeason Four-Pool equipment.

• Compressors are protected against high temperature and current.

• It is compatible with R407C or R410 coolants.

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

9

2. Technical features and Equipment

2.6. Dampers

• Dampers are sized to enable the air flow to be passed through by 100%.

• Damper wings are made in aerofoil structure with opposite motion.

• Cassette and wings are made of aluminum.

• Air leakage is minimized by using bolt at wing edges.

• Dampers can be controlled manually or by servo-motor.

2.7. Filters

• G4 filter is used in Blowing and Suction line.

• A maintenance gap is available for filter replacement and maintenance.

• The amount of air leakage in filters is minimized by by-pass sheets.

• Sight glass and lighting lamp can be applied to the filter cells.

2.8. Heat Recovery Cells

• By using heat recovery exchanger with heat pipe in devices, the productivity is increased and energy consumption and costs are decreased.

• The plate surfaces are epoxy coated against corrosion.

• A double curved condensation pan made of stainless steel is placed below the heating pipe.

• These devices, which are designed in closed system, include coolant fluid. While the temperature of moisture and warm suction air is cooled by the phase change of this fluid, the temperature of blowing air is increased.

2.9. Power and Control Panel

• The necessary protection measures are taken to provide the equipment with safe operation.

• FourSeason Four-Pool Four-Pool swimming pool dehumidification plants include a specially developed micro-processor control system consisting of SIEMENS products.

• The micro-processor system includes software that keeps the temperature values set automatically and ensures cost saving. In addition, the compressors are operated based on equal aging principle so unnecessary running of suction and ventilation fans is prevented.

• The language is optionally selected whether Turkish or English

• The system card is available for the building management system with an interface.

SUPPLY AIR

Heat pipe working principle

RETURN AIR

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

10

3.Equipment size and capacity chart

Stops the system in case of emergency.

FourSeason Four-Pord swimming pool dehumidifi-cation equipment includes Micro-Processor control panel having software designed to fulfill all demands of the system.

Duct type humidity and temperature sensors are used in FourSeason Four-Pool swimming pool dehumidification equipment.

FourSeason package hygienic air conditioning equipment includes sensitive valve servomotors that are adjusting blowing air temperature.

FourSeason Four-Pool havuz nem alma sant-ralle-yana servomotorları istenilen sıcaklık değerine bağlı olarak açılıp kapanarak üfleme hava sıcaklığını ayarlayabilen hassas kontrol ekipmanlarıdır

These units enable the equipment to be remote controlled optionally.

Differential pressure keys are used to detect the pollution of air filters and working condition of back-grounds.

These sensors are installed on blowing mouth.It communicates the air temperature values toauto-mation system.

It is a digital display for system adjustments and monitoring.

Freezing thermostats are used to prevent freezing of dehumidification equipment‘s serpentine during the winter months. Due to the freezing thermostat warning, the system is shut down the outside connection or stopped completely thus the battery break is prevented.

Fonksiyon - Ekipman Otomasyon

EmergencyStop Button

Channel TypeTemperature AndHumidity Sensors

Valveservomotors

Damperservomotors

Freezing thermostats

Central communication units

DifferentialPressure keys

Cable typetemperaturesensors

Operator Unit [display]

STANDARD

STANDARD

STANDARD

STANDARD

STANDARD

STANDARD

STANDARD

STANDARD

STANDARD

OPTIONAL

Açıklama Kullanım Durumu

Electrical ControlBoard

www.doguhvac.com

FOUR - POOL - Package Pool Dehumidifier

11

4. Ahu Size and Capacity Details.

POOL-3000 POOL-4000 POOL-4500 POOL-6000 POOL-7500 POOL-9000 POOL-11000 POOL-12000 POOL-15000 POOL-18000 POOL-21000 POOL-24000

C

D

A1

A2

B1(BASE WIDHT)

B2(BASE LENGHT)

D1

D2

V.A.A.

E.E.A.

E.A.D.

T.E.A.

1640

3580

2215

1185

1364

3388

2340

1240

256*256

660*970

412*500

412*500

1640

3735

2215

1340

1364

3543

2340

1395

288*288

660*970

512*500

512*500

2260

3735

2215

1340

1364

3543

2340

1395

322*322

970*970

512*550

512*550

2260

3890

2215

1495

1364

3698

2340

1550

361*361

970*970

612*610

612*610

2260

4045

2370

1495

1674

3853

2495

1550

404*404

970*1280

612*910

612*910

2260

4200

2370

1650

1674

4008

2495

1705

453*453

970*1280

612*910

612*910

2260

4200

2370

1650

1984

4008

2495

1705

507*507

970*1590

612*1280

612*1280

2260

4200

2370

1650

1984

4008

2495

1705

507*507

970*1590

612*1280

612*1280

2880

4355

2370

1805

1984

4163

2495

1860

569*569

1280*1590

712*1280

712*1280

2880

4665

2525

1960

2294

4473

2650

2015

638*638

1280*1900

712*1590

712*1590

3500

4665

2525

1960

2294

4473

2650

2015

715*715

1590*1900

912*1590

912*1590

3500

4665

2525

1960

2294

4473

2650

2015

715*715

1590*1900

912*1590

912*1590

MODEL

Parameter BirimPOOL3000

POOL4000

POOL4500

POOL6000

POOL7500

POOL9000

POOL11000

POOL12000

POOL15000

POOL18000

POOL21000

POOL24000

*Dehumidifier Capacity

Air Flow

Ventilating fan Pressure

Aspiration fan Pressure

Ventilating Motor

Aspirating fan motor

Cooling Capacity

Condensing Heating Capacity

Water Heating Coil Capacity 90/70

Optional Duct Type Electrical Heater

Compressor Power

***Total Power Consumption

Weight

kg/h

m³/h

Pa

Pa

kW-d/d

kW-d/d

kW

kW

kW

kW

kW

kW

kg

20

3000

300

300

1,5-1500

1,5-1500

21,10

26,40

26,15

15

5,1

8,1

1370

27

4000

300

300

2,2-1500

2,2-1500

28,70

35,67

34,12

21

6,97

10,97

1400

30

4500

300

300

2,2-1500

2,2-1500

33,30

40,96

36,24

22,5

7,7

12,1

1735

40

6000

300

300

3-1500

3-1500

42,20

52,88

50,58

30

10,2

16,2

1800

50

7500

300

300

4-1500

4-1500

52,60

65,90

62,97

37,5

12,68

20,68

2100

60

9000

300

300

5,5 – 1500

5,5 – 1500

63,8

80,68

77,1

45

15,4

26,4

2200

74

11000

300

300

5,5 – 1500

5,5 – 1500

77,55

97,65

92,75

54

19,02

30,2

2625

80

12000

300

300

7,5 – 1500

7,5 – 1500

84,41

107,98

102,53

60

20,91

35,91

2700

160

24000

300

300

11-1500

11-1500

182,43

222,48

209,88

120

43,2

65,2

4675

140

21000

300

300

11-1500

11-1500

147,59

184,70

176,46

105

36,56

58,56

4465

120

18000

300

300

11-1500

11-1500

126,54

160,72

152,57

90

30,8

52,8

3915

100

15000

300

300

7,5-1500

7,5-1500

113,08

141,34

127,47

75

27,42

42,42

3280

*Designed According to VDI 2089. ** Electrical Heater is not Included. Key Note:Selections are made According to Indoor Conditions 30C DB,%50 RH and +5C evaporation temperature.

HE

AT

P

IP

E

www.doguhvac.com

NOTES

ARKA KAPAKarkası

baskısız

FactoryITOB Organize Sanayi Bölgesi 10010 Sok.No: 4 35473 Tekeli / Menderes / Izmir / TURKEYTel: +90 (232) 799 02 40 Faks: +90 (232) 799 92 04

Istanbul RegionBarbaros Mah. Çigdem Sok. No:1 Agaoglu My OfficeKat: 4/18 Atasehir/IstanbulTel: +90 (216) 250 55 45 Faks: +90 (216) 250 55 46

Ankara RegionÇetin Emeç Bulvarı 1065 Cad. (Eski 2.Cad) 1309 Sok.No: B/4 Öveçler / Çankaya / ANKARATel: +90 (312) 472 11 45 Faks: +90 (312) 472 11 46

www.doguhvac.com