FORTINA originated in April 2009. Japanese streetscapes ...

32

Transcript of FORTINA originated in April 2009. Japanese streetscapes ...

FORTINA originated in April 2009.

In order to meet the needs of many of our customers who "wanted to replace the Japanese streetscapes with richer and more beautiful designs," Toppan, after many years of research, created a highly weather resistant decorative surface material.

Toppan will deliver FORTINA not only to the Japanese market but also worldwide. Toppan will continue to evolve while endeavouring to fulfil the requests for improving streetscapes and spaces around the world making the designs more interesting and beautiful to view.

12

32

Relazioni - Paola Lenti 2016©Paola Lenti sri - photo by Sergio Chimenti Relazioni - Paola Lenti 2016 54

76

©Nacasa & Partners Inc. ©Nacasa & Partners Inc. 98

Louvers

Interior and Exterior—Wall Applications with Stringers

Installation Guide ........................................... 15

Installation Examples ....................................... 16

Interior—Ceiling Applications with Stringers

Installation Guide ........................................... 19

Installation Examples ....................................... 20

Interior—Floor-to-Ceiling Applications

Installation Guide ........................................... 23

Installation Example ........................................ 24

Lighting Louvers

Interior—LED Front Lighting Louver with Stringers

Installation Guide ........................................... 42

Specifications ................................................. 43

Interior—Lighting Duct Louver with Stringers

Installation Guide ........................................... 45

Spandrels [Slats]

Interior and Exterior—Spandrels [Slats]

Installation Guide ........................................... 49

Interior and Exterior—

Wall and Ceiling Applications with Stringers

Louver Profiles ............................................... 26

Back Rail Profiles ........................................... 31

Accessories .................................................. 32

End Caps Installation .............................................. 33

Interior—Wall and Ceiling Direct Applications

Installation Guide ........................................... 35

Installation Examples ....................................... 36

Louver Profiles ............................................... 38

Profiles ......................................................... 50

Accessories .................................................. 51

Installation Examples ....................................... 52

Colours and Patterns

For Interior ............................................................ 53

For Exterior ........................................................... 56

Aluminum Surface Treatment..................................... 57

Technical Information

Decorative Sheet Performance Data ........................... 58

Contents

1110

丸いのに変更

Louvers originally used for blinds, creating shade, or ventilation are now seeing an increase in demand as design material.FORTINA can fulfil a variety of customer needs in a wide range of applications that differ from conventional ones through a variety of designs and shapes, as well as improvements in the quality of component parts such as end caps. Louvers are available for Direct attachment type and Stringer attachment type.

Louvers

1312

1

2

3

Vertical Installation

Horizontal Installation

Interior and ExteriorWall Applications with Stringers / Installation Guide

1514

30.6

30

.6

10

350

350

STRI

NGER

SPA

CING

STANDARD LOUVER SPACING

LOUV

ER L

ENGT

HLO

UVER

LEN

GTH

STRI

NGER

SPA

CING

Elevation

60 60 90 90 90 90

60

70

10

L-BRACKETBTS-5050

THS-3060

CLIPSBTP-17

M12×30

STAL-5STRINGER

Cross Section A–A’

Cross Section B–B’

350

350

STRI

NGER

SPA

CING

STRI

NGER

SPA

CING

LOUV

ER L

EGNT

HLO

UVER

LEG

NTH

10

BTP-17

BTS-5050

C-ANGLE BY OTHERS

M12×30 STAL-5

BTP-17

STAL-6

60 70 10

12

12

30.6

30.6

L-BRACKET

CLIP

STRINGER

STRINGER

CLIP

THS-3060

30 30 30

A‘A

B

B’

Elevation

Cross Section A–A’

Cross Section B–B’

1212

40

7010

30.6 30.6

10

BTS-5050

BTP-17

L-BRACKET

CLIP CLIP CLIPBTP-17 BTP-17

BTS-5050 L-BRACKET

M12×30

M12×30

THS-4040

STAL-6STRINGER

STAL-5STRINGER

STRINGER SPACING STRINGER SPACING

LOUVER LENGTH LOUVER LENGTH

350 350

10

30.630.6STRINGER SPACING STRINGER SPACING 350

350

350

350

LOUVER SPANLOUVER SPAN

STRINGER-TO-WALL ATTACHMENT POINT

STAN

DARD

LOU

VER

SPAC

ING

40

40

8080

80

40 70 10

THS-4040STRINGERSTAL-5

CLIPBTP-17

BTS-5050

M12×30

L-BRACKET

C-ANGLE BY OTHERS

40

40

40

40

B‘B

A

A’

Vertical Horizontal

LOUVER PROFILES AND INSTALLATION GUIDE Interior and ExteriorWall Applications with Stringers / Installation Examples

1716

1 2 3

Interior Ceiling Applications with Stringers / Installation Guide

1918

Elevation

Cross Section A–A’

Cross Section B–B’

LOUVER LENGTH

STRINGER

20

50

12

25

12 12 95.2

63

63

50 50

30

50

10

30

20

10 10

20

10

2 10

30.6 30.6

SUS M12×30

SUS M12×30

HANGING RODHANGING ROD

STRINGERSTAL-7

L-BRACKETBTS-5050

L-BRACKETBTS-5050

CLIPBTP-09

CLIPBTP-09

350

10

350

STRINGER SPAN

STAL-8

END CAP

SHS-

2010

FT

100

50

100

10 10

2 10

10

10 35

030

.6

30.6

ST

RING

ER S

PACI

NG

END CAPS

SHS-2010FT

STRINGER

STAL-8

STRINGER

STAL-7

10

10

120 120 120 55

100 100

100

1050

4520 20 20

9.2

THS-2010

350

< 350

350ROD SPACING TBD

L-STRINGER10

SUS M12×30STRINGERSTAL-7CLIP

BTP-09

L-BRACKETBTS-5050

HANGING ROD BY OTHERS

10 mm SPACE FROM WALL TO EDGE OF STRINGER

THS-2010

A‘A

B

B’

Elevation

@90

0 @

900

STRINGER

STCL-1

B B‘

A

A’

LOUVER LENGTH

350 @2000

Cross Section A–A’

P

M8×20 8015

STRINGERSTCL-1

40

5550

100

15P P P

BOLTBTP-M620

L-BRACKETBTS-4080ST

TLBS-1510

HANGING ROD BY OTHERS

Cross Section B–B’

2END CAPSLBS-1510FT

BOLTBTP-M620

805550

100

15

M8×20

HANGING ROD BY OTHERS

L-BRACKETBTS-4080ST

STRINGERSTCL-1

350

TLBS-1510

LOUVER PROFILES AND INSTALLATION GUIDE Interior Ceiling Applications with Stringers / Installation Examples

With STAL Stringer With STCL Stringer

2120

1 2 3

Interior Floor-to-Ceiling Applications / Installation Guide

2322

Elevation

Cross Section A–A’

Cross Section B–B’

CEILING

FLOOR

CEIL

ING

HEIG

HT

1010

FLAT BAR BRACE

(OPTIONAL)

152

150

2

200 200 200

150 150 150

BACK RAIL

SCREW FOR BACK RAILL-ATTACHMENT

THS-5015

THBM-50

50 50 50 50

1522

BTP-30

202020

CEILING

FLOOR

FLAT BAR BRACE

150

(OPTIONAL)

10

10

1010

L-ATTACHMENT

L-ATTACHMENT

BACK RAILTHBM-50

IF LONGER THAN 2000 mm NEEDSINTERMEDIATESUPPORT

NOTE: 10 mm space top and bottom for L-Clip thickness.

Notc

h si

ze

THS-5015

CLIP

A A‘

B

B‘

Interior Floor-to-Ceiling Applications / Installation Example

2524

TLBS-1550

THS-2040 THS-2060 THS-2080

SQUARE 15

SQUARE 20

THS-2010 THS-2015

THS-2580THS-2570

100

2025

70 80

25

20

40

20

60

20

80

150

20

SQUARE 25

TLBS-1510

100

15

TLBS-1515

50

15

150

15

Ceiling type for interior only

THSN-3030 THS-3050 THS-3060

THS-4050 THS-4080

50

30

30

30

THS-404050

40

60

30

40

40

80

40

SQUARE 30

SQUARE 40

THS-3075 THS-3080 THS-3010

100

30

80

30

75

30

THS-3015150

30

LOUVER PROFILES AND INSTALLATION GUIDE Interior and ExteriorWall and Ceiling Applications with Stringers / Louver Profiles

2726

SQUARE 50

SQUARE 60

SQUARE 75 SQUARE 100

THSN-5050

THS-50125 THS-5015

THS-6025 THS-6012

THS-7575

THS-5060 THSN-5010

50

50

50

125

50

150

50

60

50

100

75

75

THS-1040 40

100

25

60 60

120

TRAPEZOID

ROUND

TRIANGLE

50

540

5

70 75

100

25

3010

10

50

35

80

35

100

35

120

37

ø40

ø50

45

72

ø75

27.5

ø30

THTR-4070 THL-02

THC-30 THC-40 THC-50

THC-75

THV-3580 THV-3510 THV-3512

LOUVER PROFILES AND INSTALLATION GUIDE Interior and ExteriorWall and Ceiling Applications with Stringers / Louver Profiles

2928

OTHERS

60

20 3080 100

30

30

60

12

10 30

80

12

10 30

100

15

10

40

150

30

15

16.5

50

70

20

80

35

(81)

60°

18.5

26

80

60°

50

(96)

45°

25

100

100

15

120

50

30

THG-3580

THE-2060 THE-3080 THE-3010

THA-1060 THA-1080 THA-1010

THA-1515 THGR-70

THG-5080 THGF-100

THGR-120

DECORATIVE BACK RAILS

THBM-20 THBM-25 THBM-30

THBM-40 THBM-50 THBM-60

20

213

30

213

40

213 218

60

25

213

50

218

THBM-20 THBM-25 THBM-30

20

82

*80 (D) 2

THS-2080 + THBM-20ex.

25

82

*80 (D) 2

THS-2580 + THBM-25ex.

30

82

*80 (D) 2

THS-3080 + THBM-30ex.

THBM-40

THBM-50 THBM-60

THS-4080 + THBM-40ex.

40

82

*80 (D) 2

50

102

*100 (D) 2

THSN-5010 + THBM-50ex. THS-6012 + THBM-60ex.

60

122

*120 (D) 2

*Dimension (D): 40/60/80/100/150

*Dimension (D): 50/60/100/125/150

*Dimension (D): 70/80 *Dimension (D): 30/50/60/75/80/100/150 *Dimension (D): 40/50/80

*Dimension (D): 25/120

Interior and ExteriorWall and Ceiling Applications with Stringers / Louver Profiles

Interior and ExteriorWall and Ceiling Applications with Stringers / Back Rail Profiles

3130

Clips for Attaching Louver to Stringer (Sold in Sets of 20)

STAL-5 STAL-7-40STAL-6

BTP-30BTP-17

STAL-8

BTP-09 BTP-M620

Stringers

Materials: Aluminum ExtrusionRound Shaping: Outer R6000+

Materials: Aluminum ExtrusionRound Shaping: n/a

Materials: Aluminum ExtrusionRound Shaping: Outer R1800+

Materials: Aluminum ExtrusionRound Shaping: Outer R1500+

STCL-1Materials: Aluminum Extrusion

*Interior ceiling only

BTS-M1230BTS-5050 / L-BracketMaterials: Galvanized SteelUsed with STAL 5, 6, 7, 8 Stringer STL: 50×50×4

Stringer Fittings (Sold in Sets of 10)

BTS-4080ST

M12×30 SUS

40

1580

40 18

φ 11

φ 9

Aluminum Aluminum Aluminum

Length

Pa

7

3010

50

1515

3

Length

Length LengthOut R

Length

Materials: Polished Chrome FinishSt=3.2 mmUsed with STCL-1 Stringer

M8×20 ST

1

2

1

2

Screwless End Caps (20/ each) Screw-on End Caps (20/ each)

Grid Types (Square) Grid Types (Square) Grid Types (Round) □□□□ –□□□□ FTS (H)

□□□□ –□□□□ FT (H)

□□□□ –□□□□ FT (H) –φ

□□□□ –□□□□ FT

Countersunk screw M4×12 SUS

Countersunk screw M4×12 SUS

Countersunk screw M4×12 SUS

*H includes back panels

Materials: Aluminum Extrusion t=2.0

* Not available for drain hole * Drain hole

FinishingAluminum Basic Color 6 colors *Datails for page 57

Aluminum Mat Color 6 colors *Datails for page 57

Painted FinishSpecified color of

Japan Painting Contractors Association

Wood Grain Painted Finish

Rusted Effect Painted Finish

There is a possibility that rainwater, etc. may collect inside the louvers. A drain hole of ø 8 mm or more must be cut in the end caps. We are also preparing perforation type, please contact to our sales representative for more details.

*If you use decorative back panel, open a gap of 5 mm or more at the bottom, or open a drain hole on the surface of decorative back panel itself.

Drain hole (ø 8 or more)

One place per a hollow part

Drain hole processing example on the end cap

*This view is looking up from the bottom

Drain hole processing example on materials of inside louver

Drain hole(ø 8 mm or more)

Drain hole(ø 8 mm or more)

5 m

m o

r mor

e

When using it for external vertical installing, please provide a drain hole of ø 8 or more on the lower end caps.

In the case of external vertical installing

End Caps InstallationInterior and ExteriorWall and Ceiling Applications with Stringers / Accessories

3332

1

2

3

Vertical Installation

Horizontal Installation

Interior Wall and Ceiling Direct Applications / Installation Guide

3534

Elevation

Cross Section A–A’

Cross Section B–B’

1

P P P P P P

3030

50

BACK RAIL

ATTACHMENT SCREWTB-440ST

TLKS-3050

W

A

B’

H

B

A’

200

200

22

H

50

1

200

200

WALL ATTACHMENTBY CLIENT

INNER WALL BOARD BY OTHERS

TLKS-3050

C-ANGLE BY OTHERS

END CAPSLKS-3050FT

END CAPSLKS-3050FT

Elevation

Cross Section A–A’

W1 W2

H

A

A’

B B’

200

1

PP

PP

PP

75

30

WALL ATTACHMENTBY CLIENT

BACK PLATE

TLKS-3075

Cross Section B–B’

W1 W2

END CAP

SLKS-3075FT

2 15 15

75

1

C-ANGLE BY OTHERS

TLKS-3075

200

WALL ATTACHMENTBY CLIENT

LOUVER PROFILES AND INSTALLATION GUIDE Interior Wall and Ceiling Direct Applications / Installation Examples

Vertical Horizontal

3736

Others

TLKS-1030

Attachment 100

100

301

Attachment points

TLKTR-1560 TLKTR-1510 TLKTR-1515

15 20

601

15 20

1001

2015

1501

TLKV-3210

32

1001

Attachment 30

Attachment 50

TLKS-4075

Attachment 40

TLKS-3050

TLKS-3015 TLKS-3010TLKS-3075

TLKS-3060 TLKS-3030

TLKS-5010TLKS-5050 TLKS-5060

TLKS-5015

30

75

30

301

30

501

30

601

40

751

1

50

501

50

1501

50

601

30

1001

30

1501

50

1001

Attachment point

LOUVER PROFILES AND INSTALLATION GUIDE Interior Wall and Ceiling Direct Applications / Louver Profiles

3938

With the advent of LED, light is no longer just a means for illumination, it is now being seen as a part of a design that can suit a variety of situations.

By incorporating LEDs into louvers, FORTINA LED invites a new look by providing indirect lighting, whilst retaining the functionality of louvers.

Lighting duct louvers, which integrate louvers with wiring ducts, allow for a clean-look.

Innovative space designs are made possible by adding lighting to louvers.

Lighting Louvers

4140

1

2

3

Light distribution curve Horizontal surface illuminance

LED Type

L=1,000 mm / L=2,000 mm (±4mm) Lead L=500 mmConnector power cable

L=2000 mm

Red (+) : Black (–)

Lighting System | Speci�cations

Speci�cations

– / +180

150

120

90

60

30

0

0

–30

–60

–90

–120

–150

* Refer to "Instruction Manual" for construction.* For details about power supply, refer to "Power supply specifications".* For the trunk cable dimension, confirm "cable selection table".* Please inquire about the special length item other than standard length items.

Light distribution curve Horizontal surface illuminance

LED Type

L=1,000 mm / L=2,000 mm (±4mm) Lead L=500 mmConnector power cable

L=2000 mm

Red (+) : Black (–)

Lighting System | Speci�cations

Speci�cations

– / +180

150

120

90

60

30

0

0

–30

–60

–90

–120

–150

* Refer to "Instruction Manual" for construction.* For details about power supply, refer to "Power supply specifications".* For the trunk cable dimension, confirm "cable selection table".* Please inquire about the special length item other than standard length items.

Pro�le Selection

TLF-4080 TLFU-40 Cover unit

TLFB-19 LED holding component

40 40

19.4

80

15

19.5

Installation Drawings

LED

Center Corner

Pro�le Selection

TLF-4080 TLFU-40 Cover unit

TLFB-19 LED holding component

40 40

19.4

80

15

19.5

Installation Drawings

LED

Center Corner

Profile Selection

Specifications

Light Distribution Curve Horizontal Surface Illuminance Product Specifications

Installation Drawings

TLF-4080 TLFU-40

TLFB-19

Cover unit

LED holding component

Pro�le Selection

TLF-4080 TLFU-40 Cover unit

TLFB-19 LED holding component

40 40

19.4

80

15

19.5

Installation Drawings

LED

Center Corner

Product Name LED Flex Ribbon light 10 LED Flex Ribbon light 10

Product codeRa-F22B-1000-WW Ra-F22B-2000-WW

Ra-F22B-1000-CW Ra-F22B-2000-CW

Voltage DC 24V DC 24V

Power consumption 10.5W 21W

Light primary colorWW (Warm White) : 2725 ± 145K

CW (Cool White) : 4503 ± 243K

LED element Nichia SMD 5050

Material PVC-Ivory White

Luminous flux / m 450 lm / m

IP grade IP 68

IK grade IK 08

Maximum series connection length Less than 10 m

Dimming Yes *

* Refer to Specification Manual

LIGHTING LOUVER PROFILES AND INSTALLATION GUIDE Interior LED Front Lighting Louver with Stringers /Installation Guide

4342

40 33

80

15.5

Track light by others Lighting Duct Louver Cover whereTrack light does not occur.

IMPORTANT: Attaches with U Clips.

Screw-on End Cap is available

1

2

3

IMPORTANT:U-Clips needed to attached TLDU-40 Lighting Duct Cover to Louver

TLD-4080 (Lightng Louver)

TLDU-40 (Lighting Duct Cover)

Interior Lighting Duct Louver with Stringers / Installation Guide

4544

Spandrels [Slats] are used on ceilings and walls but they are also in demand as a product to create innovative large scale designs and continuity.To meet this demand, by combining numerous designs and shapes, FORTINA offers unlimited, coordinated design options.

Spandrels [Slats]

4746

1

2

3

Interior and Exterior Spandrels [Slats] Installation Guide

4948

Standard Style with Wood Grain Inside Reveal Standard Style with Aluminum Inside Reveal Flat Style

TRA-100MF

TRA-120MF

1006

11.5 4

+0-0.8

13

3

20

11.5 4

1206 +0-0.8

13

3

20

1370.5

TRA-150MF

11.5 4

1506 +0-0.8

13

3

20

1670.5

t =1.0 mm

t =1.2 mm

t =1.3 mm

Standard Style with 10 mm Reveal Flat Style with No Reveal

TRA-60STTRA-60AL

120

146

15

11.3 4 137.3

3

10

20

11.5 4 13

3

7.5

10015 10

126

20

11.5 4

6015 10

86

20

13

3

7.5

11.4 4

13

3

15015 10

176203

7.4

11.2 4 13

3

20015 10

3226

20

7.2

TRA-100STTRA-100AL

TRA-120STTRA-120AL

TRA-150STTRA-150AL

TRA-200STTRA-200AL

t =1.0 mm

t =1.0 mm

t =1.2 mm

t =1.3 mm

t =2.3 mm

13 mm Height—Profile Selection

TRA- ST TRA- AL TRA- MF *Refer to page 57.

Trims / Edge Treatment

M-16 t =1.2 mm

H Joints

M-64 t =1.2 mm

Hanging Partitions

M-71 t =1.2 mm

M-19-1 t =1.2 mm t =1.2 mm

Exterior Corner Trim

M-70 t =1.2 mm

Interior Corner Trim

M-78

Accessories for 13 mm Height

Corner Trims

M-6 t =1.5 mm M-67 t =1.2 mm

18

15

M-68 t =1.2 mm

40

19

M68

25

5 10

19

6014

579

27

25

14 5

4.7

145

1530 45

15 15

10

145

20

40

143

50.233.2

50.2

33.2

143

15

143

15

14 3

143 25

50

2550

M-69 t =1.5 mm

R75

155

15

100

100

M68

Interior and Exterior Spandrels [Slats] Accessories

Interior and Exterior Spandrels [Slats] Profiles

*Refer to page 57 for the aluminum surface treatment. 5150

JointM-64

13

(25)20

338

19

M-64SPANDREL [SLAT]

Drop Ceiling Detail

M-71, 7815

3153

5

25

27

5

1319

38

131938 1319

38

SPANDREL[SLAT]

SPANDREL[SLAT]

SPANDREL[SLAT]

M-78

M-71

Angle Design Internal Corner

M-67, 68

3819

13

3819

13

25

5

SPANDREL[SLAT]

SPANDREL[SLAT]

M-67

Wall-side Cross Section

M-16 M-19-1

5

15

3819

13

SPANDREL [SLAT]

M-16

15 15

5

M-19-1

SPANDREL [SLAT]

Angle Design External Corner

M-67, 68

1319

38

※10

※ 10100

3819

13

100

25

5

SPANDREL[SLAT]

SPANDREL[SLAT]

M-68 M-67

External Corner

M-68, 69

100

100

5

5

133010

1330

10

SPANDREL[SLAT]

M-69

M-68

Inside and Outside Corner M-70, 78

25

25

3

3

133010

1330

10

133010SPANDRELS [SLATS]

M-70M-78

M-16 M-19-1

Wall-side Longitudinal Section

30

M-19-1

150

M-16

15

900

SPANDREL[SLAT]

SPANDREL[SLAT]

WOOD GRAIN

TE-598F Pure White TE-2014 Crema Chestnut FW TE-2015 Crema Chestnut CW TE-2016 Persian Walnut W TE-635 Silky Elm TE-770 Modesty Birch W TE-947 Madras Walnut W

TE-710 Crema Cedar TE-736 Aroma Birch W TE-916 Plana Olive W TE-2041 Maquillage Elm W TE-945 Arno Birch W TE-851 Prime Teak W TE-881 Norte Oak N

TE-2025 Maquillage Elm TG TE-915 Haze OakTE-929 Foschia Elm G TE-800 Primary Oak PN TE-2034 Winter Cypress TE-911 Moderate Elm N TE-2035 Axis Oak N

TE-882 Norte Oak LAxis Oak LTE-2036 TE-901 Alba Oak TE-940 Abel Oak N TE-758 Vent Walnut N TE-941 Abel Oak MC TE-2026 Maquillage Elm MG

TE-883 Norte Oak G TE-2039 English Walnut G TE-903 Bliss Walnut M TE-776 Edel Cherry N TE-946 Arno Birch N TE-719 Feino Birch L TE-801 Primary Oak L

Colours and Patterns / For Interior

Please note that the colour in the brochure may vary from the actual product. Please note each design collection is subject to change periodically without notice.

Interior and Exterior Spandrels [Slats] / Installation Examples

5352

WOOD GRAIN

TE-835 Raffine Cherry L TE-904 Accord CherryTE-2037 Rold Cherry M TE-836 Raffine Cherry MTE-2033 Autumn Chestnut TE-853 Prime Teak MTE-2017 English Walnut M

TE-917 Plana Olive BTE-2038 Stretta Teak M TE-942 Abel Oak B TE-2022 Chalked Sucupira SGTE-2020 Bloom Walnut MB TE-2021 Bloom Walnut B TE-2023 Chalked Sucupira BB

TE-2024 Chalked Sucupira SB TE-802 Primary Oak MTE-902 Bliss Walnut B TE-948 Madras Walnut DG TE-913 Robust Elm G TE-891 Madras Walnut M TE-884 Verde Walnut M

TE-943 Fram Oak TG TE-854 Prime Teak D TE-766 Soleil Tineo D TE-914 Robust Elm D TE-2018 English Walnut B

TE-944 Fram Oak D TE-608 Glamorous Mahogany

TE-885 Verde Walnut RBTE-2019 Antique Walnut

TE-769 Forte Walnut D TE-886 Verde Walnut D TE-760 Vent Walnut D TE-803 Primary Oak DBTE-2040 English Walnut BL

White Elm NeoTA-026

WOOD GRAIN

TE-715 Classy Wood TE-804 Primary Oak G TE-808 Vent Walnut BL TE-742 Astro Walnut BL

FIBER

TA-018 Black FiberTA-017 White Fiber

STUCCO

TA-019 Solid Stucco

STONE

TA-023 Pietra Lime(Light)

TA-022 Siena Granit (sabi-ishi color)

TA-025 Alterna Sandstone (White)

TA-027N Pacific Gray

Symphony Walnut BTE-2050 Symphony Walnut DTE-2051 Stylish Maple NTE-2052

Frettare Oak NTE-2053 Frettare Oak GTE-2054 Revlon Wall WTE-2055 Revlon Wall MTE-2056 Revlon Wall BTE-2057 Legacy Ash GTE-2058 Legacy Ash DGTE-2059

Tendre Walnut LGTE-2060 Tendre Walnut MGTE-2061 Noir Imbuia DTE-2062

Colours and Patterns / For Interior

Please note that the colour in the brochure may vary from the actual product. Please note each design collection is subject to change periodically without notice.

Colours and Patterns

5554

TA-012 installation image

WOOD GRAIN WOOD GRAIN-CHARACTERISTIC-

WOOD GRAIN -BASIC-

METAL

TERRA COTTA

-JAPANESE MODERN-

TA-001 Terra Cotta Clay TA-002 Terra Cotta Arrosto TA-003 Terra Cotta Rosso

STONE

TA-006 Spangle Metal D TA-009 Aging Metal PD TA-010 Aging Metal PM TA-011 Aging Metal CTA-007 Spangle Metal M TA-008 Spangle Metal L

TA-024 Alterna Sandstone (Black)

TA-013 Antique Cedar G TA-014 Antique Cedar RB TA-015 Antique Cedar D TA-004 Rokko Cedar TA-012 Bamboo

TA-005 Rican Oak TA-758 Vent Walnut N TA-647 Earl Walnut M TA-532 Cherry Line M TA-605 Blossom Birch TA-602 Vintage Walnut

TA-760 Vent Walnut D TA-021 Criollo Elm TA-808 Vent Walnut BL TA-028 Pacific GrayTA-775 Carina Elm D

BASIC COLOUR

Silver Stain Colours Light Bronze Bronze

Dark Bronze Black

MATT COLOUR

Silver Matt Stain Colours Matt Light Bronze Matt Bronze Matt

Dark Bronze Matt Black Matt

Colours and Patterns—Aluminum Surface Treatment

Please note that the colour in the brochure may vary from the actual product. Please note each design collection is subject to change periodically without notice. Please note that the colour in the brochure may vary from the actual product. Please note each design collection is subject to change periodically without notice.

Colours and Patterns / For Exterior

5756

Interior SpecificationsEvaluation Items Test Items Test Method Test Result

Weather resistance Accelerated weathering test Apply light beam for a certain duration of time with a sunshine carbon arc weather meter. No remarkable change after irradiation of 2,000 hours

Heat resistance Heat resistance test (company standard) Leave the specimen in an oven at a temperature of 60 ± 5ºC for 48 hours. No remarkable change

Water resistance Water resistance test (company standard) Immerse the specimen in room temperature water for 24 hours and then dry it. No remarkable change

Humidity resistance Humidity resistance test (company standard) Leave the specimen in a tank at a constant temperature and humidity of 40 ± 2ºC and 90 ± % RH for 48 hours. No remarkable change

Heat cycle resistance Heat-cold repeating test (based on JAS heat-cold repeating C test)

Put a specimen measuring 150 x 150 mm in an oven at a temperature of 60 ± 3ºC, leave it there for two hours, and leave it in a low-temperature tank at - 20 ± 3ºC for two hours. Repeat this for two cycles. No remarkable change

Chemical resistance

Chemical resistance (company standard)Apply (a) 2% sodium hydrate, (b) 5% acetate solution, and (c) petroleum benzine to the specimen, leave it for six hours and wipe them off. No remarkable change

Chlorine resistance test (company standard)

Apply chlorine of 1.0 mg/L, which is the sanitation criterion for a swimming pool, and chlorine of 10.0 mg/L, 10 times higher concentration of the above, to the specimen, leave it for 24 hours, 48 hours, and 72 hours, and wipe it off. However, change chlorine water every six hours considering the decomposition rate of chlorine.

No remarkable change

Sanitation criterion of a swimming pool: The residual free chlorine concentration of water in a swimming pool shall be 0.4 mg/L or more. The desired concentration is 1.0 mg/L (according to the notification of the Director-General, Environmental Health Bureau, Ministry of Health and Welfare).

No remarkable change

Pollution resistancePollution resistance test (1)

Apply each detergent (weak alkali, neutral, and weak acid), insecticide, and heating oil to each specimen, leave them for six hours, and wipe them off. No remarkable pollution

Pollution resistance test (2) Apply each pollutant, wipe it off with water or ethanol after a lapse of 24 hours and observe the appearance. No remarkable pollution

Abrasion resistance Abrasion resistance test (pattern loss) (based on JAS abrasion C test)

Conduct a test on a 120 x 120 mm specimen with a taper abrasion tester and calculate the rotational value when the loss of pattern reaches 50%. Over 200 times

Scratch resistance Scratch resistance test (company standard) Pencil hardness test based on JIS K 5400 (load of 500 g) B~2B

Exterior SpecificationsEvaluation Items Test Items Test Method Test Result

Dimensional stability Heat resistance testPut a cross-cut measuring 100 mm x 100 mm at the center of a specimen, leave it at a temperature of 65ºC for two days, and check the clearance at the cross-cut part. No remarkable clearance

Weather resistance Accelerated weathering testApply a light beam to the specimen with a sunshine carbon arc weather meter for 8,000 hours and check the appearance. No remarkable change

Heat resistance Long-term heat resistance test Leave the specimen in each oven for 1,000 hours and check the appearance.60ºC No remarkable change80ºC No remarkable change

Heat cycle resistance Heat-cold repeating testConduct 100 cycles, with each cycle consisting of 80ºC for two hours switched to -20ºC for two hours, and observe the appearance. No remarkable change

Dry/wet cycle resistance Dry/wet cycle test

Conduct 20 cycles, with each cycle consisting of 40ºC and 30% RH for 8 hours switched to 40ºC and 90%RH for 16 hours, and observe the appearance. No remarkable change

Humidity resistance Long-term humidity resistance testLeave the specimen in a high humidity tank at a constant temperature of 40ºC and 90%RH and observe the appearance. No remarkable change

Scratch resistance Pencil scratch resistance (based on JIS H8602)

Apply the core of the pencil to the specimen while applying a load of 1 kg to the angle of about 45º and scratch the surface toward the front at a constant speed. 2B

Abrasion resistanceAbrasion resistance test

Rotate the specimen 7,000 times with a taper abrasion tester (abrasion wheel: CS-17; and load: 1 kg) and observe the appearance.

Slight loss of pattern occurred

Falling sand abrasion resistance test (based on JIS H8602)

Let a grinding material fall through a guiding tube of 20 mm in inner diameter to the specimen at an angle of 45º at a falling rate of 320 g/min. and measure the time when the base material begins to be exposed and the abrasion depth.

Abrasion end point: 5,100 sec.

Abrasion depth: -0.06 mm

Low temperature impact resistance Dupont impact test Let a 1 kg weight fall from a height of 30 cm to the specimen at 5ºC and observe the appearance. No cracking

Pollution resistance

Pollution resistance test (1)Immerse dry cotton in a solvent, rub the surface of the specimen with the cotton for 20 strokes and observe the appearance.

Petroleum benzine No remarkable change

Methyl ethyl ketone No remarkable change

Ethyl acetate No remarkable change

Ethanol No remarkable change

Pollution resistance test (2)Apply each pollutant, wipe it off with water or ethanol after a lapse of 24 hours and observe the appearance.

Blue ink No remarkable change

Black shoe cream No remarkable change

Black marker No remarkable change

Red crayon No remarkable change

Oil and solvent resistance testApply each oil and solvent, wipe it off with water after a lapse of 24 hours and observe the appearance.

Heating oil No remarkable change

CRC556 No remarkable change

Ethanol No remarkable change

Petroleum benzine No remarkable change

Acid resistance Acid resistance test Immerse the specimen in a 1% sulfuric acid aqueous solution for one hour and observe the appearance. No remarkable change

Alkali resistance Alkali resistance test (based on JIS H8602)Put a drop of 5 g/l sodium hydrate aqueous solution to the surface, leave it for 24 hours, wash the solution off with water, and observe the appearance. No remarkable change

Corrosion resistance CASS corrosion resistance test (based on JIS H8602)

Put the specimen in a test tank, spray a sodium chloride solution of a 50 g/l concentration to the specimen for 48 hours, and observe the appearance. No remarkable change

Adhesiveness Cross-cut peel test (based on JIS H8602)Scratch the surface at an interval of 2 mm in both the longitudinal and transverse directions to the depth that reaches the base material, make 100 grids with those scratches, apply cellophane tape over the grids, and peel it off.

100/100no abrasion

Adhesive strength

Normal state adhesiveness testPull the sheet in a 180 degree direction at a rate of 200 mm/min. relative to the base material under a normal room temperature and measure the adhesive strength. 20.0 N/25 mm or more

Heat creep resistance testApply a load at a rate of 500 g/25 mm to the sheet at a 90 degree direction relative to the base material at 60ºC and measure the peeling distance 30 min. later. <5 mm

Cold creep resistance testApply a load at a rate of 500 g/25 mm to the sheet at a 90 degree direction relative to the base material at -20ºC and measure the peeling distance 30 min. later. <5 mm

Technical Information—Decorative Sheet Performance Data

5958

Teams for FORTINA

TOPPAN PRINTING CO., LTD.Global Sales Department, Environmental Design Subdivision, Living & Industry Division

1-5-1 Taito, Taito-ku, Tokyo 108-8536 JapanPhone: +81-3-3835-6826 / 6827 FAX: +81-3-3835-6781 / 6782

Toppan Interamerica Inc. Georgia Factory

1131 Highway 155 South, McDonough, GA 30253 U.S.A. Phone: +1-770-957-5060 FAX: +1-770-957-6447

Pennsylvania FactoryThousand Oaks Corporate Center, Thousand Oaks Blvd., Morgantown, PA 19543 U.S.A.Phone: +1-610-286-3100 FAX: +1-610-286-3101

Toppan Europe GmbH Head Office

Heinrichstr. 83-85, 40239 Düsseldorf, GermanyPhone: Phone: +49-211-7327600 FAX: +49-211-363688

London Branch5th Floor, 15 Basinghall Street, London EC2V 5BR U.K.Phone: +44-20-7213-0500

Shanghai Toppan International Trading Co., Ltd. 9F, GLOBAL HARBOR TOWER B,1188 NORTH KAIXUAN RD.,SHANGHAI, CHINAPhone: +86-21-6223-2803     FAX: +86-21-6223-2300

Toppan Cosmo, Inc. Taiwan Representative Office 14F-6 No.378 SEC 1 Wunshin Rd, Taichung city, TaiwanPhone: +886-4-2323-5598 FAX: +886-4-2323-5587

Toppan Cosmo, Inc. Jakarta Representative Office Tempo Scan Tower, 32nd Floor, Jl.HR Rasuna Said Kav. 3-4Jakarta Selatan, 12950, IndonesiaPhone: +62-21-2934-9300 FAX: +62-21-2934-9301

Toppan Printing Co., Ltd. Singapore Branch 97 Ubi Avenue 4, Singapore 408754Phone: +65-6589-5454 FAX: +65-6589-5455

http://forest.toppan.co.jp/fortina/english/

6160