LED Line 1 ft 2000 lm 3R HV2 October 2015 Datasheet Key features and benefits • LED module efficiency of up to 158 lm/W • Long life-time: up to >100,000 hours • High color rendering: CRI >80 • Excellent color consistency of 3 SDCM • High Tc life of 90 °C for usage in rough application conditions • Tc range of -40 °C to + 95 °C enables extreme ambient temperatures • Choice of color temperatures (3000 K, 3500 K, 4000 K and 5000 K) • Lumen package: 2000 lm per foot (tunable up to 3000 lm per foot) Fortimo LED Line High Flux system are designed to enable LED lighting at higher application heights where more light is needed, such as trunking, battens and high-bay applications in warehouses, factories or big retail stores. Fortimo LED Line High Flux Gen2 Retail Office Industry Suitable for:

Transcript of Fortimo LED Line High Flux Gen2 - Philips · 2016. 11. 13. · The Philips LED module generates a...

  • LED Line 1 ft 2000 lm 3R HV2

    October 2015

    Datasheet

    Key features and benefits• LED module efficiency of up to 158 lm/W• Long life-time: up to >100,000 hours• High color rendering: CRI >80• Excellent color consistency of 3 SDCM• High Tc life of 90 °C for usage in rough application conditions• Tc range of -40 °C to + 95 °C enables extreme ambient temperatures• Choice of color temperatures (3000 K, 3500 K, 4000 K and 5000 K)• Lumen package: 2000 lm per foot (tunable up to 3000 lm per foot)

    Fortimo LED Line High Flux system are designed to enable LED lighting at higher application heights where more light is needed, such as trunking, battens and high-bay applications in warehouses, factories or big retail stores.

    Fortimo LED Line High Flux Gen2

    Retail O�ce Industry

    Suitable for:

  • 2 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    Ordering data

    Commercial product name EOC 12NC

    Fortimo LED Line 1ft 2000lm 830 3R HV2 8718696 480946 00 9290 009 70306

    Fortimo LED Line 1ft 2000lm 835 3R HV2 8718696 480960 00 9290 009 71006

    Fortimo LED Line 1ft 2000lm 840 3R HV2 8718696 480984 00 9290 009 70406

    Fortimo LED Line 1ft 2000lm 850 3R HV2 8718696 481004 00 9290 009 70506

    Drive currents and case temperatures

    Parameter Nominal* Life** Max*** Unit

    I (current through the LED module) 426 630 650 mA

    Tc (case temperature at Tc point) 45 90 95 °C

    * Nominal value at which typical performance is specified.** Value at which lifetime L70B50 ≥ 50,000 hour is specified.*** Maximum value for safe operation; do not operate above this value.

    Optical characteristics - table per color (CCT)

    Fortimo LED Line 1 ft 2000 lm 830 3R HV2Parameter Min Typ Max Unit

    Correlated color temperature (CCT) 3000 K

    Color coordinates (CIEx, CIEy) (0.437, 0.404) -

    CRI 80 -

    Radiation angle 120 deg

    Color consistency of 3 SDCM, averaged over the module.

    Rel

    ativ

    e in

    tens

    ity

    (a.u

    )

    Wavelength (nm)

    1

    0.8

    0.6

    0.4

    0.2

    0380 430 480 530 580 630 680 730 780

    830

    Operation point 830 lm lm/W

    80% I-nom 341 mA Tc 25 °C 1588 154

    Tc-nom 45 °C 1531 151

    Tc-life 90 °C 1404 144

    I-nom 426 mA Tc 25 °C 1970 150

    Tc-nom 45 °C 1900 147

    Tc-life 90 °C 1743 141

    I-life 630 mA Tc 25 °C 2854 141

    Tc-nom 45 °C 2755 138

    Tc-life 90 °C 2530 132

    Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.

    Fortimo LED Line 1 ft 2000 lm 835 3R HV2Parameter Min Typ Max Unit

    Correlated color temperature (CCT) 3500 K

    Color coordinates (CIEx, CIEy) (0.410, 0.393) -

    CRI 80 -

    Radiation angle 120 deg

    Color consistency of 3 SDCM, averaged over the module.

    Rel

    ativ

    e in

    tens

    ity

    (a.u

    )

    Wavelength (nm)

    1

    0.8

    0.6

    0.4

    0.2

    0380 430 480 530 580 630 680 730 780

    835

    Operation point 835 lm lm/W

    80% I-nom 341 mA Tc 25 °C 1638 159

    Tc-nom 45 °C 1579 156

    Tc-life 90 °C 1448 149

    I-nom 426 mA Tc 25 °C 2032 155

    Tc-nom 45 °C 1960 152

    Tc-life 90 °C 1798 145

    I-life 630 mA Tc 25 °C 2944 146

    Tc-nom 45 °C 2841 143

    Tc-life 90 °C 2609 136

    Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.

  • 3 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    180°

    30°30°

    60°60°

    90°90°

    120°120°

    100

    200

    300

    400

    (cd/1000 lm 0° L.O.R.= 1.00

    0-180° 90-270°

    Beam shape

    The Philips LED module generates a Lambertian beam shape, which is a pragmatic starting point for OEMs wishing to design secondary optics.

    Fortimo LED Line 1 ft 2000 lm 840 3R HV2Parameter Min Typ Max Unit

    Correlated color temperature (CCT) 4000 K

    Color coordinates (CIEx, CIEy) (0.384, 0.382) -

    CRI 80 -

    Radiation angle 120 deg

    Color consistency of 3 SDCM, averaged over the module.

    Fortimo LED Line 1 ft 2000 lm 850 3R HV2Parameter Min Typ Max Unit

    Correlated color temperature (CCT) 5000 K

    Color coordinates (CIEx, CIEy) (0.346, 0.358) -

    CRI 80 -

    Radiation angle 120 deg

    Color consistency of 3 SDCM, averaged over the module.

    Rel

    ativ

    e in

    tens

    ity

    (a.u

    )

    Wavelength (nm)

    1

    0.8

    0.6

    0.4

    0.2

    0380 430 480 530 580 630 680 730 780

    840

    Rel

    ativ

    e in

    tens

    ity

    (a.u

    )

    Wavelength (nm)

    1

    0.8

    0.6

    0.4

    0.2

    0380 430 480 530 580 630 680 730 780

    850

    Operation point 840 lm lm/W

    80% I-nom 341 mA Tc 25 °C 1671 162

    Tc-nom 45 °C 1612 159

    Tc-life 90 °C 1478 152

    I-nom 426 mA Tc 25 °C 2073 158

    Tc-nom 45 °C 2000 155

    Tc-life 90 °C 1835 148

    I-life 630 mA Tc 25 °C 3004 149

    Tc-nom 45 °C 2899 146

    Tc-life 90 °C 2663 139

    Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.

    Operation point 850 lm lm/W

    80% I-nom 341 mA Tc 25 °C 1671 162

    Tc-nom 45 °C 1612 159

    Tc-life 90 °C 1478 152

    I-nom 426 mA Tc 25 °C 2073 158

    Tc-nom 45 °C 2000 155

    Tc-life 90 °C 1835 148

    I-life 630 mA Tc 25 °C 3004 149

    Tc-nom 45 °C 2899 146

    Tc-life 90 °C 2663 139

    Tolerance for flux data is ±7.5%.Tolerance for efficacy data is ±10%.

    Measurement tolerance is ± 2.5% for the flux data and 5% for the efficacy data.

  • 4 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    Performance over life

    Lumen maintenanceOperation point Time x 1000 hours L70 L80 L90

    B50 B20 B10 B50 B20 B10 B50 B20 B10

    80% I-nom 340 mA Tc 25 °C >100 100 100 94 91 90 44 43 42

    Tc-nom 45 °C 100 100 99 65 63 62 31 30 29

    Tc-life 90 °C 63 61 60 39 38 38 19 18 18

    I-nom 426 mA Tc 25 °C >100 100 100 94 91 90 44 43 42

    Tc-nom 45 °C 100 100 99 65 63 62 31 30 29

    Tc-life 90 °C 63 61 60 39 38 38 19 18 18

    I-life 630 mA Tc 25 °C >100 100 100 94 91 90 44 43 42

    Tc 45 °C 100 100 99 65 63 62 31 30 29

    Tc-life 90 °C 63 61 60 39 38 38 19 18 18

    Values in the table are based on available LM80 LED data (12000h). Lumen maintenance will be updated once additional measurement data becomes available. >70k hours claim is based on extrapolating raw LM80-data to lower temperatures and currents by using statistical techniques.

    Parameter Min Typ Max Unit

    Δu'v' at 6000 hours 0.007 -

    Specifications stated while Tc < Tc-life and I < I-life.

    Absolute maximum ratings

    Parameter Min Typ Max Unit

    Current through the LED module (I-max) 650 mA

    Case temperature (Tc-max) 95 °C

    Power rated at U-max and I-max 22.7 W

    ESD (direct contact) 8 kV

    ESD (air) 15 kV

    Working voltage (between input to metal mounting plate) 420 Vdc

    Voltage strength (Input to metal mounting plate) 1840 Vac

    Ambient temperature -40 °C

    Wiring

    Specification item Value Unit Condition

    Input wire cross-section 0.2…0.75 mm2 Solid

    18…24 AWG

    0.3..0.5 mm2 Stranded

    20..22 AWG

    Input wire strip length 7.5..8.5 mm

    Tested cable length 4000 mm Total length of wiring including LED modules,

    one way

    Connector suited for robot wiring.

    Electrical characteristics

    Parameter Min Typ Max Unit

    Nominal current 426 mA

    Forward voltage 28.9 30.3 31.7 V

    Power consumption 12.3 12.9 13.5 W

    Energy efficiency label A++

    Minimum dimming for performance 10 %

    Number of modules per chain 8

    Bins 2 (I and D)

    Specifications stated at Tc-nom and I-nom.

  • 5 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    Mechanical characteristics

    Parameter Min Typ Max Unit

    Length 279.75 280 280.25 mm

    Width 54.8 55 55.2 mm

    Height excl. connector 1.5 1.65 1.8 mm

    Height incl. connector 5.65 5.85 6.05 mm

    Warpage (IPC-TM-650) 2.1 mm

    Bow & Twist of the PCB after production tested and released according IPC-TM-650 2.4.22.

    ININ

    OUTOUT

    4055

    20

    7649 8026

    26

    280

    Ø4

    .75

    1.5

    5.9

    9

    1.6

    5

    4.2

    4

    0.9

    7.75

    A (2:1)

    A

    Connector, suited for robot wiringPolarity sensitive

    Hole allows wire feed through

    Connector, suited for robot wiringPolarity sensitive

    Approbation andconformity marks

    Area suited for clamping (4x)

    Module specicinfo sticker Tc point

    Screw hole (4x)max. M4 screw size

    ININ

    OUTOUT

  • 6 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    Application information

    Compliance and approvalIEC / EN 62031, IEC / EN 62471

    Photobiological safetyRisk Group: Risk Group 1

    EnvironmentalRoHS / REACH

    Application informationZhaga

    Designation of the Book-7 LLE category L28W6

    Luminous Flux category C020

    CCT category 3000 K, 3500 K, 4000 K, 5000 K

    CRI 80

    The position of the temperature measurement point tp Same as Tc point

    The value of tp, max 45

    IP rating No IP rating

    Overheating protection No protection

    Luminaire class IEC Class I or Class II

    Warranted number of full thermal product cycles at which the survival rate of the population ≥90%, at 25°C ambient temperature

    Case temperature Tc [°C] Amount of cycles

    35 14,600

    40

    45

    50 14,600

    55

    60

    65 14,600

    70

    75

    80 14,600

    85 14,600

    90 13,000

    95

  • 7 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    Flux and efficacy versus currentI [mA] Flux [%] Efficacy [%]

    50% Inom 210 50% 107%

    250 59% 106%

    300 71% 104%

    350 83% 102%

    I nom 426 100% 100%

    500 117% 98%

    I-life 630 145% 94%

    Flux and efficacy versus temperature at TcTc [°C] Flux [%] Efficacy [%]

    (Tc-life) 90 92% 95%

    80 94% 96%

    70 95% 97%

    60 97% 99%

    55 98% 99%

    (Tc-nom) 45 100% 100%

    25 104% 102%

    0 108% 104%

    Tuning information

    0 10 20 30 40 50 60 70 80

    Tc (°C)

    110%

    105%

    100%

    95%

    90%

    85%

    80%

    75%

    Valu

    e re

    lati

    ve t

    o n

    om

    inal

    (%

    )

    E�cacy (%)Flux (%)

    0 50 100 150 200 250 300 350 400 450 500 550 600 650 700

    Single LED module current (mA)

    150%140%130%120%110%

    100%90%80%70%60%50%40%30%

    Rel

    ativ

    e nu

    mb

    er

    E�cacy (%)Flux (%)

  • 8 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    Lumen maintenance

    0% 100%

    0% 100%

    70%

    0 10,000 20,000 30,000 40,000 50,000 70,000 60,000

    Operating lifetime (hours)

    Lum

    en m

    aint

    enan

    ce (

    %) Lum

    en dep

    reciation (%

    )

    B50B10

    0% 100%

    0% 100%

    70%

    0 10,000 20,000 30,000 40,000 50,000 70,000 60,000

    Operating lifetime (hours)

    Lum

    en m

    aint

    enan

    ce (

    %) Lum

    en dep

    reciation (%

    )

    Tc 25 °CTc nom 45 °CTc-life 90 °C

    Lumen maintenance at I-life and Tc-life conditions

    Lumen maintenance for B50 at current I-life conditions

    Lumen depreciation as a function of operating hours for I-life and Tc-life.

    Lumen depreciation as a function of operating hours at different Tc values and I-life.

  • 9 - 10 Datasheet - Fortimo LED Line 1 ft 2000 lm 3R HV2 October 2015

    Wiring schematic

    More information in the design-in guide of LED Linear modules.

    Rset

    Rset

    Rset

    HV system1 chain (1C)

    HV system1 chain (1C)

    HV system2 chain (2C)

    Chain 1 dierent lenghtas Chain 2 = NOK

    Idrive = Inom

    Vdrive = Vf x # boards

    Idrive = Inom

    Vdrive = Vf x # boards

    Idrive = Inom x #C

    Vdrive = (Vf x # boards) / #C

    Non-Isolated LED driver 1 ft HV LED board

    HV LED board HV LED board

    HV LED board HV LED board

    HV LED board HV LED board

    1 ft HV LED board 1 ft HV LED board 1 ft HV LED board Return End

    Return End

    Return End

    Return End

    +-

    Non-Isolated LED driver+-

    Non-Isolated LED driver+-

    Examples

  • © 2015 Koninklijke Philips N.V. All rights reserved. Philips reserves the right to make changes inspecifications and/or to discontinue any product at any time without notice or obligation andwill not be liable for any consequences resulting from the use of this publication.

    10/2015 Data subject to change

    www.philips.com/technology www.philips.com/fortimo www.philips.com/xitanium