FORMENTERA CTFS CONDENSING BOILERS FORMENTERA … · Inovia Cond, Rinnova cond, Parva recupera /...
Transcript of FORMENTERA CTFS CONDENSING BOILERS FORMENTERA … · Inovia Cond, Rinnova cond, Parva recupera /...
Pre-set to run on Methane or LPG
Available heat outputs:
➲ Touch screen user interface
➲Ready for connection to an external probe (optional)
➲26-plate DHW heat exchanger
➲
Controls to manage three different types of solar thermal systems fitted as standard (solar probe is optional)
➲Boiler hydraulic replacement kit
24kW
CTFS
28kW
CTFS
32kW
CTFS
24kW
CTN
28kW
CTN
FORMENTERA CTFS FORMENTERA CTN CO
ND
ENSI
NG
BO
ILER
S
MONO-THERMAL
EN
• Mono-thermal heat exchanger
• 26-plate stainless steel DHW heat exchanger
• 3-speed pump with integrated air purging device
• Integrated hydraulic assembly including: three-way valve, automatic
by-pass, safety valve, pressure transducer, unloading tap, connection to
the expansion vessel
• Integrated safety and modulation electronic board
• Installation flexibility thanks to IPX5D electrical protection degree
• Multifunctional relay for connection to systems with zone valves or to
solar systems or to remote boiler shutdown alarms
• Virtual room temperature control with weather compensation via
external temperature probe (option)
• Management of high-and low-temperature heating zones via electric
board (option)
• Energy efficiency marking (92/42/EC) CTFS:★★★ CTN: ★★
THE PRICE INCLUDES: Standard hydraulic kit, paper template, flue gas discharge diaphragm, air-intake blanking tap kit.
ModelType of
gasCode Heat output kW
Efficiency at nominal heat output
Gross weight(kg)
FORMENTERA CTFS 24sealed chamber
METHANE CFNxx2CA2423.7 93.0 % 37.50
LPG CFNxx3CA24
FORMENTERA CTFS 28sealed chamber
METHANE CFNxx2CA2828.6 93.7 % 38.00
LPG CFNxx3CA28
FORMENTERA CTFS 32sealed chamber
METHANE CFNxx2CA3230.8 93.4 % 38.50
LPG CFNxx3CA32
FORMENTERA CTN 24open chamber
METHANE CFNxx2CC2423.1 90.6 % 36.00
LPG CFNxx3CC24
FORMENTERA CTN 28open chamber
METHANE CFNxx2CC2827.4 90.0 % 36.50
LPG CFNxx3CC28
FORMENTERA CTFS and CTN
G Gas inlet (½”)
M CH flow (¾”)
C DHW outlet (½”)
F Cold water inlet (½”)
R CH return (¾”)
top viewbottom view
750
420 315
76 60 62 67 82 73
12118
515
413
1
132
4792
210135147
ACCESSORIES
DIMENSIONS AND CONNECTION CENTRE DISTANCES
750
420 315
76 60 62 67 82 73
12118
515
413
1
132
4792
210135147
750
420 315
76 60 62 67 82 73
12118
515
413
1
132
4792
210135147
MC
FR
G
R
750
420 315
121
131
154
185
117
76 60 62 67 82 73
210 210
750
420 315
121
131
154
185
117
76 60 62 67 82 73
210 210M
C
F
GG
CTFS
CTN
Article Description Code
Air-intake/flue gas coaxial connection for type B22 installation 0ATTCOVE03
Pipes and taps cover 0COPETUB03
Remote control 0CREMOTO04
Fixing template (metal) 0DIMMECO11
Wall spacer kit 0DISTANZ00
Ø 100/60 mm, 1 metre type “A”coaxial kit for TFS models
0KITCONC00
Protection kit for outdoor installation, with anti-freeze kit, for condensing boilers for TFS models
0KITCOPE03
ProtProtection kit for outdoor installation, for condensing boilers
for TFS models0KITCOPE04
Article Description Code
Sludge remover 0KITDEFA00
Flow - return cold water 90° taps kit 0KITIDBA11
Solar connection kit (for combi boilers)
0KITSOLC07
Connection kit for complex solar systems 0KITSOLC08
Baxi/ Formentera replacement kit- Luna 3 System HT - Luna 3 Comfort HT - Luna
Platinum HT - Prime HT0KITSOST08
Beretta/ Formentera replacement kit- Esclusive Green - Mynute Green
- Mybute Sinthesi0KITSOST09
Immergas/ Formentera replacement kit
- Victrix 50 - Victrix Mini0KITSOST10
Vaillant/ Formentera replacement kit- Eco Block Exclusive - Eco block Plus
- Eco Block Pro0KITSOST11
Ariston/ Formentera replacement kit- Clas Premium - Genus Premium - Genus - Clas 0KITSOST12
Tahiti/ Formentera replacement kit 0KITSOST13
Biasi/Savio replacement kit - Inovia, Inovia Cond, Rinnova cond, Parva recupera /
Aludens, Evodens, Futura, Superevo due0KITSOST14
Electric zone kit with external probe 0KITZONE05
Standard split pipe kitfor TFS models 0SDOPPIA11
“Plus” split pipe kit (0.5 meter long pipes)
for TFS models0SDOPPIA12
External probe 0SONDAES01
Temperature probe for solar heating plants PSPTMILL00
Inhibitor for multi-metal systems (0.5 L bottle) 0PROTIMP00
Universal cleaner (0.5 L bottle) 0PROTIMP01
Liquid inhibitor for domestic multi-metal systems (10 L bottle) 0PROTIMP02
Neutral universal cleaner (10 L bottle) 0PROTIMP03
Liquid inhibitor for 3/4” filter 0PROTIMP04
Hydrocyclone and magnetic filter 0FILTIMP00
Gas and water tap kit 0KITRUBI04
WALL-HUNG GAS COMBI BOILER WITH INSTANT PRODUCTION OF DOMESTIC HOT WATER, OPEN COMBUSTION CHAMBER
The
man
ufac
ture
r res
erve
s th
e rig
ht to
car
ry o
ut th
e ne
cess
ary
chan
ges
with
out p
rior n
otic
e.U
ff. P
ubb.
Fon
dita
l CTC
03
C 61
2 - 0
1 N
ovem
bre
2016
(500
- 11
/201
6)
TECHNICAL SPECIFICATIONS CTFS 24 CTFS 28 CTFS 32 CTN 24 CTN 28
No. nozzles - 11.0 13.0 15.0 11.0 13.0
Nominal heat input kW 25.5 30.5 33.0 25.5 30.5
Reduced heat input kW 12.5 13.5 16.0 10.0 12.5
Nominal heat output kW 23.7 28.6 30.8 23.1 27.4
Reduced heat output kW 11.1 12.0 14.3 8.5 10.8
Useful efficiency at nominal heat input % 93.0 93.7 93.4 90.6 90.0
Useful efficiency at 30% % 90.2 90.6 91.0 89.4 87.9
Casing heat loss with burner on at nominal heat input % 1.05 0.76 1.37 1.88 2.83
Casing heat loss with burner off % 0.26 0.20 0.20 0.57 0.57
Chimney heat loss with burner on at nominal heat input % 5.97 5.54 5.23 7.52 7.17
Energy efficiency marking (92/42/EC) - ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★ ★
CH maximum working pressure bar 3.0 3.0 3.0 3.0 3.0
CH maximum working temperature °C 83 83 83 83 83
CH temperature range °C 35-78 35-78 35-78 35-78 35-78
Expansion vessel capacity l 7 7 7 7 7
Consumption at nominal heat output (CH) Methane m3/h 2.70 3.23 3.49 2.70 3.23
Consumption at nominal heat output (CH) Propane kg/h 1.98 2.37 2.56 1.98 2.37
Consumption at nominal heat output (CH) Butane kg/h 2.01 2.41 2.60 2.01 2.41
DHW maximum pressure bar 6.0 6.0 6.0 6.0 6.0
DHW minimum pressure bar 0.5 0.5 0.5 0.5 0.5
DHW nominal flow ∆T 30°C l/min 11.6 14.2 15.1 11.2 13.5
DHW minimum heat input l/min 3.0 3.0 3.0 3.0 3.0
DHW maximum working temperature °C 62 62 62 62 62
DHW temperature range °C 35-57 35-57 35-57 35-57 35-57
Air-flue ΔT at nominal heat input °C 95.0 101.0 105.0 86.0 96.0
Flue gas flow at nominal heat input g/s 15.44 17.29 17.80 20.73 21.70
CO2 at nominal heat input Methane % 6.1 7.0 7.4 4.9 5.5
CO2 at nominal heat input Propane % 6.7 7.7 8.4 5.6 6.5
CO2 at nominal heat input Butane % 7.0 8.0 8.7 5.8 6.5
Supply pressure Methane mbar 20 20 20 20 20
Supply pressure Propane mbar 37 37 37 37 37
Supply pressure Butane mbar 28-30 28-30 28-30 28-30 28-30
Power supply voltage/frequency V/Hz 230/50 230/50 230/50 230/50 230/50
Fuse on the power supply A 3.15 3.15 3.15 3.15 3.15
Power absorption W 125 134 134 86 86
Electric protection rating - IPX5D IPX5D IPX5D IPX5D IPX5D
Gas fitting - G ½ G ½ G ½ G ½ G ½
CH fittings - G ¾ G ¾ G ¾ G ¾ G ¾
DHW fittings - G ½ G ½ G ½ G ½ G ½
Coaxial air intake/flue gas duct diameter mm 100/60 100/60 100/60 - -
Split air intake/flue gas duct diameter mm 80+80 80+80 80+80 - -
Flue gas duct diameter mm - - - 130 130
LxHxD mm 420x750x315
Net weight kg 34.00 34.50 35.00 32.50 33.00
Gross weight kg 37.50 38.00 38.50 36.00 36.50
FONDITAL S.p.A.
25079 VOBARNO (Brescia) Italy
Via Cerreto, 40 - Tel. + 39 0365 878.31 www.fondital.com