BIDDING DOCUMENT

FOR

MODIFICATION TO REGIONAL OFFICE BUILDING

AT KURUNEGALA

B/07/2018

CEYLON PETROLEUM CORPORATION

2018

Page 2: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

CONTENTS

Pages

SECTION 1 - INSTRUCTIONS TO BIDDERS……………………………… 1 - 2

SECTION 2 - STANDARD FORMS (CONTRACT) .……………………… 3 - 9

SECTION 3 - CONDITIONS OF CONTRACT…………………………….. 10 - 11

SECTION 4 - FORM OF BID AND QUALIFICATION

INFORMATION …………………………………………….. 12 - 14

SECTION 5 - BIDDING DATA AND CONTRACT DATA………………. 15 – 22

SECTION 6 - SPECIFICATIONS ………………………………………….. 23 – 24

SECTION 7 - BILL OF QUANTITIES……………………………………... 25 - 55

SECTION 8 - DRAWINGS ………………………………………………. … 56 - 57

SECTION 9 - STANDARD FORMS (BID)…………………………….......... 58 - 60

CHECKLIST FOR BIDDERS ………………………………………………. 61

Page 3: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

INVITATION FOR BIDS

Note :

The relevant form shall be filled by the Procuring Entity and included

in Volume 2 of the bidding documents.

Note :

Bidders are advised to consider the information printed in bold & Italic in the

document as a checklist, when preparing their bids. However, it is the

responsibility of the bidders to comply with all the requirements given in the

bidding document.

Page 4: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

INVITATION FOR BIDS (IFB)

Ceylon Petroleum Corporation (Ministry of Petroleum Resources

Development

MODIFICATION TO REGIONAL OFFICE BUILDING AT

KURUNEGALA

(400023693)

B/ 07/2018

1. The Chairman Departmental Procurement Committee (DPC) on behalf of the Ceylon

Petroleum Corporation invites sealed bids from eligible and qualified contractors for the contract

“Modification to Regional office Building at Kurunegala” at an estimated cost of Rs. 15.0

Million.

The period of Construction of this work is six (06) Months.

2. Bidding will be conducted through National Competitive Bidding Procedure.

3. To be eligible for contract award, the successful bidder shall have not been blacklisted and shall

meet the ICTAD Registration C6 or above.

4. Qualification requirements to qualify for contract award include: Bidders applied for this tender

should have ICTAD Registration C6 or above.

5. Interested Prospective bidders may obtain further information from Manager (Procurement &

Stores) over the Tele Nos. 5455330 or 5666225 or Facsimile No : 5455424 and inspect the bidding

documents in his Office at No. 609, Dr. Danister De Silva Mawatha, Colombo 09, from 0900 hrs.

to 1500 hrs. until 02.02.2018.

6. A complete set of Bidding Document in English language may be purchased by interested bidders

on submission of a written application to the Manager (Procurement & Stores) from 0900 hrs.

to 1500 hrs. until 02.02.2018. upon payment of a non refundable fee of Rs 2,000.00

(i.e. Rs. 1,705.02 + 2% NBT + 15% VAT). The method of payment will be by cash .

7. Bids shall be delivered to the Manager (Procurement & Stores), Procurement & Stores

Function, Ceylon Petroleum Corporation, 1st Floor, No.609, Dr. Danister De Silva Mawatha,

Colombo 09 on or before 1400 hrs. on 05.02.2018. Late bids will be rejected. Bids will be

opened soon after closing and in the presence of the bidders or their authorized representatives who

choose to attend.

8. The bidders designated representative is invited to attend a pre-bid meeting which, if

convened and informed to the bidders, will take place at Regional Office (Kurunegala),

Ceylon Petroleum Corporation at No. 20/3, Noyel Senevirathne Mawatha, Colombo

Road, Kurunegala. The pre-bid will be conducted at 10.00 a.m. on 25.01.2018.

9. All bids shall be accompanied by a Bid-Security of Rs. 250,000.00.

Chairman,

Departmental Procurement Committee,

C/o Manager (Procurement & Stores),

Procurement & Stores Function,

Ceylon Petroleum Corporation,

1st Floor, No. 609, Dr. Danister De Silva Mawatha,

Colombo 09.

Page 5: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 1 of 61

Section - 1

INSTRUCTIONS TO BIDDERS

Notes :

Instructions to Bidders shall be read in conjunction with Bidding Data under Section 5

(Volumn 2). Matters governing the performance of the Contractor, payments under the

Contract, or matters affecting the risks, rights, and obligations of the parties under the

Contract are included under Section 3 - Conditions of Contract (Volume 1) and Contract

Data under Section 5 (Volume 2). However, some information is reproduced in this Section

facilitate the bidder to price their bids.

Instructions to Bidders will not be a part of the Contact and will ceases to have effect once

the Contract is signed.

Note :

Bidders, may consider the information printed in bold & Italic in the document as a

checklist when preparing their bids. However, it is the responsibility of the bidders to

comply with all the requirements in the bidding document.

Page 6: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 2 of 61

Section 1

1. INSTRUCTIONS TO BIDDERS

Instructions to Bidders applicable for this Contract are that given in Section 1 of the

Standard Bidding Document for Procurement of Works, ICTAD Publication No.

ICTAD/SBD/01, January 2007, published by the Institute for Construction Training

and Development [ICTAD], “Savsiripaya”, Wijerama Mawatha, Colombo 07.

This publication will not be issued with the Bidding Document and Bidder is advised to

Purchase it from ICTAD.

Page 7: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 3 of 61

Section - 2

STANDARD FORMS (CONTRACT)

o Letter of Acceptance

o Agreement

o Performance Security

o Advance Payment Security

o Retention Money Guarantee

Page 8: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 4 of 61

Notes on Standard Forms :

Bidders shall submit the completed Form of Bid Security as appropriate in

compliance with the requirements of the bidding documents.

Bidders should not complete the Form of Agreement at the time of preparation of

bids.

The successful bidder will be required to sign the Form of Agreement, after the

award of contract.

Any corrections or modifications to the accepted bid resulting from arithmetic

corrections, acceptable deviations, or quantity variations in accordance with the

requirements of the bidding documents should be incorporated into the Agreement.

The Form of Performance Security, Form of Advance Payment Security and Form of

Retention Money Guarantee should not be completed by the bidders at the time of

submission of bids.

The successful bidder will be required to provide these securities in compliance with

the requirements herein or as acceptable to the Employer.

Notes on Form of Letter of Acceptance

The Letter of Acceptance will be the basis for formation of the Contract as described in

Clause 1.6.3 of the Instructions to Bidders. This Form of Letter of Acceptance should be

filled in and sent to the successful bidder only after evaluation of Bids and after obtaining

approval from the relevant authority.

Page 9: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 5 of 61

FORM OF LETTER OF ACCEPTANCE

[Letter heading paper of the procuring entity]

---------------------------------------- [date]

To: ---------------------------------------------------------------------------------------------------------------------

[name and address of the Contractor]

This is to notify you that your bid dated ------------------- [insert date] for the construction and

remedying defects of the ------------------------------------------------------------------- [name of the

Contract and identification number] for the Contract price of ---------------------[name of currency]

---------------------------------------------------[amount in figures and words] as corrected in accordance

with Instructions to Bidders and / or modified by a Memorandum of Understanding, is hereby

accepted.

The adjudicator shall be --------------------------------------- [name and address of the Adjudicator, if

agreed] / shall be appointed by the Institute for Construction Training and Development (ICTAD).

You are hereby instructed to proceed with the execution of the said Works in accordance with the

Contract documents.

The Start Date shall be: ------------------------- (fill the date as per Conditions of Contract).

The amount of Performance Security is : ------------------- (fill the date as per Conditions of Contract).

The Performance Security shall be submitted on or before --------------------- (fill the date as per

Conditions of Contract).

Authorized Signature : -----------------------------------------

Name and title of Signatory : -------------------------------------------------------------

Name of Agency : ----------------------------------------------------------------------------

Page 10: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 6 of 61

STANDARD FORM: AGREEMENT

This AGREEMENT, made the ----------[day] day of ------------[month] 20-------- [year] between

------------------------------------[name and address of Employer] (hereinafter called “the Employer”) of

the one part, and --------------------------------------------------------- [name and address of Contractor]

(hereinafter called “the Contractor”) of the other part.

WHEREAS the Employer desires that the Contractor execute -----------------------------------[name and

identification number of Contract] (hereinafter called “the Works”) and the Employer has accepted

the Bid by the Contractor for the execution and completion of such Works and the remedying of any

defects therein.

NOW THIS AGREEMENT WITNESSETH as follows:

1. In this Agreement, words and expressions shall have the same meanings as are respectively

assigned to them in the Conditions of Contract hereinafter referred to, and they shall be

deemed to form and be read and construed as part of this Agreement.

2. In consideration of the payments to be made by the Employer to the Contractor as hereinafter

mentioned, the Contractor hereby covenants with the Employer to execute and complete the

Works and remedy any defects therein in conformity in all respects with the provisions of the

Contract.

3. The Employer hereby covenants to pay the Contractor in consideration of the execution and

completion of the Works and the remedying of defects wherein the Contract Price or such other

sum as may become payable under the provisions of the Contract at the times and in the manner

prescribed by the Contract.

In Witness whereof the parties thereto have caused this Agreement to be executed the day and year

aforementioned, in accordance with laws of Sri Lanka.

………………………………………. ……………………………………….

Authorized signature of Contractor Authorized signature of Employer

COMMON SEAL COMMON SEAL

In the presence of:

Witnesses :

1. Name and NIC No. ………………………………………………

Signature …………………………

Address …………………………………………………………..

2. Name and NIC No. ………………………………………………

Signature …………………………

Address ………………………………………………………….

Page 11: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 7 of 61

FORM OF PERFORMANCE SECURITY

( Unconditional )

……………………………………………………………………………………

[Issuing Agency’s Name, and Address of Issuing Branch or Office]

Beneficiary: ………………………………………………………………………………........

[Name and Address of Employer]

Date: ……………………………

PERFORMANCE GUARANTEE NO.: …………………….

We have been informed that ………………………………………....[name of Contractor]

(hereinafter called “ the Contractor”) has entered into Contract No…………[reference

number of the contract] dated……………….with you, for the …...insert “Construction”]

of ………………………………………………….[name of contract and brief description of

Works] (hereinafter called “the Contract”).

Furthermore, we understand that, according to the conditions of the Contract, a performance

guarantee is required.

At the request of the Contractor, we…………………………………………[name of Agency]

hereby irrevocably undertake to pay you any sum or sums not exceeding in total an amount of

…………..[amount in figures] (………………………………………….. ) [amount in

words], upon receipt by us of your first demand in writing accompanied by a written

statement stating that the Contractor is in breach of its obligation(s) under the Contract,

without your needing to prove or to show grounds for your demand or the sum specified

therein.

This guarantee shall expire, no later than the……….day of…………., 20…..[insert date, 28

days beyond the Intended Completion Date] and any demand for payment under it must be

received by us at this office on or before that date.

-------------------------- [Signature(s)]

Page 12: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 8 of 61

FORM OF ADVANCE PAYMENT SECURITY

……………………………………………………………………………[Name and address

of Agency, and Address of Issuing Branch or Office]

Beneficiary: …………………………………………………………..[Name and Address of

Employer]

Date : …………………………………….

ADVANCE PAYMENT GUARANTEE NO.:………………………………

We have been informed that …………………………………………......[name of Contractor]

(hereinafter called “the Contractor”) has entered into Contract No……………….(reference

number of the contract] dated……………………………….with you, for the ………………

Construction of ………………………....[name of contract and brief description] (hereinafter

Called “the Contract).

Furthermore, we understand that, according to the conditions of the Contract, an advance

payment in the sum……………..[amount in figure] (………………………………..[amount

in words] is to be made against an advance payment guarantee.

At the request of the Contractor, we…………………………………[name of issuing agency]

Hereby irrevocably undertake to pay you any sum or sums not exceeding in total an amount

of…………………..[amount in figures] (…………………………………………….)

[amount in words] upon receipt by us of your first demand in writing accompanied by a

written statement stating that the Contractor is in breach of its obligation in repayment of the

advance payment under the Contract.

The maximum amount of this guarantee shall be progressively reduced by the amount of the

advance payment repaid by the Contractor.

This guarantee shall expire on……………………[Insert the date, 28 days beyond the Intended

Completion date]

Consequently, any demand for payment under this guarantee must be received by us at this

office on or before that date.

---------------------------------------

[Signature(s)]

------------------------------ 4 The Guarantor shall insert an amount representing the amount of the advance payment and denominated

either in the currency(ies) of the advance payment as specified in the Contract.

Page 13: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 9 of 61

FORM OF RETENTION MONEY GUARANTEE

……………………………………………………………………………….[Issuing Agency’s

Name, and Address of Issuing Branch or Office]

Beneficiary :…………………………………………………………….. .[Name and Address

of Employer]

Date : …………………………….

RETENTION MONEY GUARANTEE NO.:…………………………….

We have been informed that …………………………………………….[name of Contractor]

(hereinafter called “the Contractor”) has entered into Contract No…………………[reference

number of the contract] dated…………………with you, for the execution of …………[name

of contract and brief description of Works] (hereinafter called “the Contract”).

Furthermore, we understand that, according to the conditions of the Contract, when the works

have being taken over and the first half of the Retention Money has been certified for

payment, payment of the second half of the Retention Money may be made against a

Retention Money guarantee.

At the request of the Contractor, we………………………………………...[name of Agency]

Hereby irrevocably undertake to pay you any sum or sums not exceeding in total an amount

of …………………………[amount in figures] (……………………………………………...)

[ amount in words5] upon receipt by us of your first demand in writing accompanied by a

written statement stating that the Contractor is in breach of its obligation under the Contract

because the Contractor has not attended to the defects in accordance with the Contract.

This guarantee shall expire, at the latest,………………………[insert 28 days after the end of

the defects liability period]. Consequently, any demand for payment under this guarantee

must be received by us at this office on or before that date.

--------------------------

[Signature(s)]

----------------------------- 5 The Guarantor shall insert an amount representing the amount of the second half of the Retention Money.

Page 14: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 10 of 61

SECTION – 3

CONDITIONS OF CONTRACT

Conditions of Contract shall be read in conjunction with Section 5- Contract Data in

Volume 2, which shall take precedence over the Conditions of Contract.

Page 15: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 11 of 61

Section – 3

3.0 GENERAL CONDITIONS OF CONTRACT

General Conditions of Contract applicable for this Contract are that given in Section 3

of the Standard Bidding Document for Procurement of Works, ICTAD Publication No.

ICTAD/SBD/01, January 2007, published by the Institute for Construction Training

and Development [ICTAD], “Savsiripaya”, Wijerama Mawatha, Colombo 07.

This publication will not be issued with the Bidding Document and Bidder is advised to

Purchase it from ICTAD.

General Conditions of contract shall be read in conjunction with schedule provided

under Section 5 of the Bidding Document.

Page 16: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 12 of 61

SECTION - 4

FORM OF BID AND QUALIFICATION

INFORMATION

Note :

Bidders are advised to consider the information printed in Bold & Italic in the document as

a checklist, when submitting their bids. However, it is a responsibility of the bidders to

comply with all the requirements given in the bidding document.

Page 17: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 13 of 61

Form of Bid

Note : Prior to issue of the bidding documents, the Employer should insert relevant data for all

items marked with an asterisk (*).

Name of Contract : Modification to Regional Office Building at Kurunegala

To : Ceylon Petroleum Corporation

Gentleman,

1. Having examined the Standard Bidding Document - Procurement of Works

[ICTAD/SBD/01 - Second Edition, January 2007], Specifications, Drawings and Bills of

Quantities and Addenda for the execution of the above-named Works, we the undersigned,

offer to execute and complete such Works and remedy any defect therein in conformity

with the aforesaid Conditions of Contract, Specifications, Drawings, Bills of Quantities and

addenda for the sum of Sri Lankan Rupees ....................................... (LKR ...................) or

such other sums as may be ascertained in accordance with the said Conditions.

2. We acknowledge that the Contract Data forms part of our Bid.

3. We undertake, if our Bid is accepted, to commence the Works as stipulated in the Contract

Data, and to complete the whole of the Works comprised in the Contract within the time

stated in the Contract Data.

4. We agree to abide by this Bid for the period of Seventy Seven (77) Days from the date fixed

for receiving or any extended period and it shall remain binding upon us and may be

accepted at any time before the expiration of that period.

5. Unless and until a formal agreement is prepared and executed this Bid, together with your

written acceptance thereof, shall constitute a binding contract between us.

6. We accept / we do not accept the Adjudicator.

7. We understand that you are not bound to accept the lowest or any Bid you may receive.

Dated this ............. day of ............ 20... in the capacity of .............. duly authorized to sign tenders

for and on behalf of ............................................................................

(IN BLOCK CAPITALS)

Signature : ....................................................

Address : ...............................................................................................................

Witness : ....................................................

Page 18: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 14 of 61

Qualification Information

(To be completed and submitted by the bidder, with the Bid) ( if requested only)

ICTAD Registration Registration number

(attach copies of relevant pages from the registration book)

Grade

C6 or above

Specialty

Buildings

Expiry Date

Blacklisted Contractors

Have you been declared as a defaulted contractor by NPA or any other Agency? (Yes/No)

IF yes provide details

VAT Registration Number

Construction Program ( attach as annex)

Legal status (attach relevant status copies, as annex)

Value of Construction works

performed in last 5 years

(attach copies of Certificate of Completion etc. and other

documents such as profit-loss and income expenditure statement)

Year 2016

Year 2015

Year 2014

Year 2013

Year 2012

Value of similar works completed

in last 05 years (indicate only the

three largest projects)

1. Value Year ……………..

2. Value Year …………..

3. Value Year …………….

(attach copies of Certificate of Completion etc., as annex)

Major items of construction

equipment proposed

1. type Capacity ………………

2. type Capacity ………………

3. type Capacity …………….....

4. type Capacity ……………….

5. type Capacity ……………….

Qualification and experience of key

staff – Site & Head Office

(Permanent, Contract basis &

Consultants)

Technical:

1.

2.

3.

Managerial:

1.

2.

3. Other information requested under

ITB Clause 4.1

Page 19: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 15 of 61

SECTION – 5

BIDDING DATA AND CONTRACT DATA

Page 20: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 16 of 61

5.1 Bidding Data

Instructions to Bidders

Clause Reference

1.1 The Employer is

Name : Ceylon Petroleum Corporation

Address : “609”, Dr. Danister De Silva Mw., Colombo 09.

The Works Consists of – Modification to Regional Office Building at

Kurunegala Located at : Kurunegala

1.2 Intended Completion Date is six (06) months from the Start Date.

1.3 The Office for collection of bid forms is :

Manager (Procurement & Stores), Procurement & Stores Function,

1st Floor, No. 609, Dr. Danister De Silva Mw., Colombo 09.

The non-refundable fee is Rupees Rs. 2,000.00 (including Taxes)

The Bid Forms will be issued until 02.02.2018.

2.1 The source of funds is Ceylon Petroleum Corporation

4.2 The registration required

Specialty : Building Construction

Grade : C6 and above.

Page 21: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 17 of 61

4.3 The following information shall be provided in Section 4:

* ICTAD Registration;

Registration number

Grade

Specialty

Expiry Date

* VAT Registration number

* Construction Programme

* Legal Status (Sole proprietor, Partnership, Company etc. )

* Total monetary value of construction work performed for each of the last five years;

* Experience in works of a similar nature and size for each of the last five years;

* Major items of construction equipment proposed to carry out the Contract;

* Qualifications and experience of key site management and technical personnel proposed for the

Contract;

* any other.

4.4

* Average of the annual volume of construction work performed in the last five

years shall be similar to the estimated cost given in the “Invitation For Bids”

* Experience in the construction of at least one contract of similar nature Works

(building & steel structures) over the last 05 years (to comply with this

requirement, works cited should be at least 70 percent completed);

* Following technical and managerial Staff:

Technical Staff :

1. NDT Civil with 3 years - 01 Full Time

Page 22: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 18 of 61

9.1

11.1

12.0

Employer’s address for the purpose of clarification is ;

Name : Mr. S.D.S. Rajapakse

Address : Manager (Procurement & Stores), Procurement & Stores Function,

1st Floor, No. 609, Dr. Danister De Silva Mw. Colombo 09.

Fax : 5455424, Tel : 5455330, 5666225

The language of the bidding document shall be English.

Any other ________________________________________

13.3

VAT component shall not be included in the rates. The amount written in the

Form of Bid shall be without VAT. However VAT component shall be shown

separately at the end of the BOQ.

13.4

The Contract is not subjected to price adjustment in accordance with Clause 47 of the

Conditions of Contract.

14.1 Bidders are not allowed to bid in foreign currencies

15.1

The Bid shall be valid up to Seventy seven ( 77 ) days from the date of closing of the

Bid.

16.1 Bid shall include a Bid Security using the form included in Section 9.

16.2

Bid Security shall be:

for an amount of Rs. 250,000.00 Valid until 105 days (i.e. until 21.05.2018)

from the date of closing the Bid .

issued by a Bank or an Insurance Company operating in Sri Lanka and

acceptable to Employer using the form for bid security (unconditional guarantee)

included in Section 9 Standard Forms.

19.2 a

19.2 b

The Employer’s address for the purpose of Bid submission is

Manager (Procurement & Stores), Procurement & Stores Function, 1st Floor, No.

609, Dr. Danister De Silva Mw., Colombo 09.

Contract name: Modification to Regional Office Building at Kurunegala

Contract no : 400023693

Page 23: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 19 of 61

20.1 The deadline for submission of Bids shall be 05.02.2018.

28.1 For evaluation and comparison of Bids under Sub-Clause 29.2 tes and prices quoted in

foreign currencies by the bidders will be converted to Sri Lanka Rupees using middle

exchange rate published by the Central Bank of Sri Lanka, on the date of closing of the

Bid.

34.0 The amount of Performance Security is 5% of the Initial Contract Price.

36.0 Clause 36.0 Adjudicator will be reformulated as follows.

Arbitration

36.1 Any doubt, difference, dispute, controversy or claim arising, out of or in

connection with or touching or concerning the execution or maintenance of the

works in this contract, or on the interpretation thereof or on the rights, duties,

obligations, or liabilities of any of the parties thereto or on the operation, breach

termination, abandonment, foreclosure or invalidity thereof, shall be finally

settled by arbitration after written notice by either party to the contract to the

other for a decision to a sole arbitrator to be appointed as hereinafter provided.

36.2 The Party desiring arbitration shall nominate three arbitrators out of which one to

be nominated by the other party within 21 days of the receipt of the said

request. If the other party does not nominate one to serve as Arbitrator within

the stipulated period the party calling for arbitration shall nominate one of the

three and inform the other party accordingly.

36.3 The arbitration shall be conducted in accordance with Arbitration Act No. 11 of

1995.

36.4 If the Arbitrator so appointed is unable or unwilling to act or resign the

appointment or vacate his office due to any reason whatsoever another

Arbitrator shall be appointed in the same manner as mentioned aforesaid.

36.5 The Arbitrator so appointed shall be entitled to determine the rules of procedure

to be followed in the Arbitration.

36.6 The Arbitration shall be held in Sri Lanka and the venue if not finalized by the

parties, shall be decided by the Arbitrator.

Page 24: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 20 of 61

Contract Data

(Please note that the Clause nos. given hereunder are that of Conditions of Contract)

1.1 The Employer is

Name : Ceylon Petroleum Corporation

Address: No. 609, Dr. Danister De Silva Mawatha., Colombo 09.

Name of Authorized Representative : To be informed after awarding the

Contract

1.1 The Engineer is

Name : Eng. & Premises Manager

Address : Engineering & Premises Function,

7th Floor, No. 609, Dr. Danister De Silva Mw.,

Colombo 09.

Name of Engineer's Representative : To be notified after awarding the

Tender

1.1 The Works consists of : Modification to Regional Office Building at

Kurunegala

1.1

The Site is located at : Kurunegala

1.1

The Start Date shall be Fourteen (14) Days from the Letter of

Acceptance.

2.3

The following documents also form part of the Contract:

1. Bidding Data

2. Contract Data

3. Specification

4. B.O.Q.

Page 25: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 21 of 61

8.1 Schedule of other contractors:

Name Period

Not Applicable (N/A)

N/A

9.1

Schedule of Key Personnel:

(a ) NDT (Civil) Engineers with three years Site Experience (full time)

13.1

The minimum insurance covers shall be :

(a) 10% of the initial Contract value ( for the Employer )

(b) 110% of the initial contract value ( for the contractor )

17.1

The Intended Completion Date for the whole of Works shall be

Six (06) months from the Start Date

21.1 The Site Possession Date shall be Fourteen (14) Days from Letter of

Acceptance

27.1 The Contractor shall submit a programme for the Works within

Seven (07) Days of delivery of the Letter of Acceptance.

27.3

The period between Programme update is One month

Page 26: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 22 of 61

27.4 The amount to be withheld for late submission of a Programme is Rupees

10% of the value of the bill certified.

35.1

39.2

The Defects Liability Period is 365 Days.

Engineer may order variations up to a total cumulative value of not

exceeding Rs. 5% of the initial contract value.

44.1 The following events shall also be Compensation Events:

Not Applicable

46.1

47.1

The exchange rate used for calculating the amounts to be paid in

currencies other than Sri Lankan Rupees is : Not Applicable

The Contract Price is not subjected to price adjustment

Input

Percentage

48.1 The retention from each payment shall be 10% percent of the certified

work done.

The limit of retention shall be 5% percent of the Initial Contract Price.

49.1

50.1

The liquidated damages for the whole of the Works shall be Rs.

1/2000 of the initial contract value Per Day.

The maximum amount of liquidated damages for the whole of the Works

shall be 10% percent of the Initial Contract Price. If the total amount of

the liquidated damages exceed 10% of the initial contract value, the

contract is liable for termination.

52.1

The Performance Security shall be 5% percent of the Initial Contract

Price.

58.1 Schedule of operating and maintenance manuals.

60.1 The percentage to apply to the value of the work not completed,

representing the Employer's additional cost for completing the Works,

is 25% of the initial Contract Value.

Page 27: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 23 of 61

Section – 6

SPECIFICATIONS

Page 28: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 24 of 61

Section – 6

SPECIFICATIONS

6.1 GENERAL SPECIFICATIONS – ICTAD.

6.1.1 Relevant latest publications of ICTAD (No SCA /4 volume 1 As at 1st June. 1998).

6.2 General Specifications

6.2.1 Specifications for water supply ,sewerage and storm water Drainage works, ICTAD

Publication No. SCA /3/2 Revised Edition – April 2002.

6.2.2 Specification for Building works– Sri Lanka. ICTAD Publication No. SCA /4

6.2.3 Standard bidding document procurement of works ICTAD/SBD/01.

6.3 Method of Measurement

6.3.1 The Bill of Quantities has been prepared generally in accordance with the “Sri Lanka

Standard Method of Measurement” (SMM 573,1999) and quantities given here may not be

100% accurate. Payment will be made based on the actual measurement at the site.

Page 29: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala- ip Page 25 of 61

Section - 7

BILL OF QUANTITIES

Notes : In preparation of the Bidding Document the users are advised to;

(1) Include appropriate Preliminary Bill items as Bill No.01 in

Accordance with ICTAD Publication No. ICTAD/ID/04

(2) Allow provision for the Bidders to include the VAT and NBT Components

separately and instruct them not to carry the VAT and NBT Components

to the Form of Bid.

(3) Advise the bidders that any discount offered will not be considered

for Provisional Sum Items.

Page 30: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

A/- DEMOLISH WORK

A01 Demolish and removing of existing store room ,

stores , rest room and wash room area . (Approx. size

40' 0'' x 40' 0'' ) and remove from site to a place

provided by the contractor . 1.0 Item

A02 Removing existing all Electrical wiring with fitting

(as shown in drawing ) and remove from site to a

place provided by the contractor. 1.0 Item

A03 Remove existing all timber doors and windows (as

shown in drawing ) and remove from site to a place

provided by the contractor. 1.0 Item

A04 Remove existing Asbestos sheets roof with timber

frame work and asbestos ceiling with timber frame

work in existing building and remove from site to a

place provided by the contractor.(Appro. area 35 .0

Sqrs) 1.0 Item

A05 Demolish and removing of existing cement rendered

floor area and remove from site to a place provided

by the contractor (ground floor and upper floor). 375.0 m2

A06 Demolish and remove existing 9'' thick brick wall and

remove from site to a place provided by the contractor

(ground and upper floor). 140.0 m2

A07Remove existing bath rooms fittings (01 No wash

basing , 01 nos water closet , 01 no bath tub and other

necessary fittings and floor tile and wall tile etc) in

R.M's bath room (Size 10' 0'' x 10' 0'') and remove

from site to a place provided by the contractor .1.0 Item

A08 - Ditto - upper floor bath room 1.0 Item

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

Page 26 of 61

Page 31: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

A09 Remove existing concrete roof carporch (approx area

13' 0'' x 15' 0'') including 02 nos 225mm x225mm

Reinforce cement concrete column and beams and

remove from site to a place provided by the

contractor. 20.0 m2

A10 - Ditto - balconys (35' 0'' x 6' 0'' ) 20.0 m2

A11Demolish and remove existing drain (approx 225 mm

wide x 150mm to 300mm average depth) and remove

from site to a place provided by the contractor.28.0 m

A12 Demolish and removing of existing septic tank in rear

side of building (Approx. 6' 0''x 7' 6'' x 10' 0'' high )

and remove from site to a place provided by the

contractor. 1.0 Nr

B/- EARTH WORK

B01 Excavation for wall foundation depth not exceeding 3'

0'' from finished ground level. 23.0 m3

B02 Excavation for column foundation depth not

exceeding 3' 0'' from finished ground level. 15.0 m3

B03 Supply, filling and compacting imported soil in layers

not exceeding 6'' at any time watered well rammed and

consolidated 57.0 m3

Anti-termite treatment

B04Anti-termite treatment to be carried out from a reputed

company to excavated surfaces and backfilled areas to

manufacturers specifications. (Tenderer to submit

technical proposals along with the tender) payments

will be effected only on submission of guarantee for a

period of ten ( 05 )years. 355.0 m

2

TOTAL DEMOLISH WORK CARRIED TO SUMMARY

TOTAL EARTH WORK CARRIED TO SUMMARY

Page 27 of 61

Page 32: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

C CONCRETE WORK

Plain Concrete -1:3:6 (1''agg. ) -Grade -15

C/01 2'' thick concrete screed under column and trench

footings. 56.0 m2

C/02 3'' thick concrete in all floor area including pavement.

( proposed stores building area and existing office

area). 372.0 m2

Reinforced cement concrete -1 : 11/2 : 3 (3/4'' agg. )

- Grade - 25

(Reinforcement measured separately)

C/03 1' 0'' thick column footing 6.00 m3

C/04 In column base up to Plinth beam level 1.20 m3

C/05 In column from Plinth beam level up to 1st floor level 2.85 m

3

C/06 In 1st floor beams 4.30 m3

C/07 5'' thick 1st floor slab 160.00 m2

C/08 9'' x 9'' plinth beams at D.P.C. level reinforced with 4

nos 12mm tor bars with 6mm M.S. stirrups at 6'' crs

(R/F and F/W measured separately) 4.3 m3

C/09 -Ditto- 9'' x 6'' cement concrete lintol in 1:2:4(20mm)

concrete, reinforced with 2nos 12mm tor bars with

6mm M.S. stirrups at 6'' crs. Rate to include R/f and

F/w . 11.0 m

Water Proofing

The method of water proofing with the materials

proposed to be forwarded with the quotation

C/10 Supply and apply "Xypex" or approved equivalent

water proofing agent to manufactures specification to

bath rooms ,water tank slab , balcony and blind wall. 260.0 m2

Reinforcement

C/11 12mm tor steel in columm footing 170.00 Kg

Page 28 of 61

Page 33: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

C/12 12mm tor steel in columm (ground and upper floor) 470.00 Kg

C/13 12mm tor steel in Plinth beam 310.00 Kg

C/14 12mm tor steel in 1st floor beam 350.0 Kg

C/15 10mm tor steel in 1st floor slab 2200.0 Kg

C/16 6mm mild steel in columns (ground and upper floor) 175.0 Kg

C/17 -Ditto - Plinth beam 130.0 Kg

C/18 -Ditto - 1 st floor beam 130.0 Kg

Sawn form work

C/19 To sides of plinth beam 38.00 m2

C/20 To sides of 1 st floor beam 56.00 m2

C/21 To sides and soffit of slab 168.00 m2

D/- MEASONRY WORK

Rubble work

D01 Rubble masonry in cement sand mix 1:5 in trench

foundation 40.0 m3

Brick work

D02 9'' thick brick work in cement sand mix 1:5 in

walls(ground floor) 215.0 m2

D03 4'' thick solid cement Block work in cement sand mix

1:5 in bath room partition wall.(ground floor) 48.0 m2

TOTAL CONCRETE WORK CARRIED TO SUMMARY

TOTAL MEASONRY WORK CARRIED TO SUMMARY

Page 29 of 61

Page 34: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

E/- DOORS AND WINDOWS

Aluminium Door and window

Note

All Aluminium Doors and Windows extrusions

shall be powder coated and of approved colour ,

Total thickness of 60 - 80 microns.

E01 Supply and fixing of Door type ''D'' overall size 4' 6'' x

8' 0'' high Aluminium framed glazed double sash door

with louvers above and all as per detailed drawing .

Rate to include necessary fittings including Stainless

steel Door handle,door lock approved make and

quality, hinges and barrol bolt etc. as approved by the

Engineer. (02No) 6.8 m2

E02 Supply and fixing of Door type ''D1'' overall size 4' 0''

x 7' 0'' high Aluminium framed glazed door with

louvers above and all as per detailed drawing . Rate to

include necessary fittings including Stainless steel

Door handle,door lock approved make and quality,

hinges and barrol bolt etc. as approved by the

Engineer. (02No) 3.9 m2

E03 - Ditto - upper floor (02 nos) 3.9 m2

E04 Supply and fixing of Door type ''D2'' overall size 4' 0''

x 7' 0'' high Aluminium framed glazed door with

louvers above and all as per detailed drawing . Rate to

include necessary fittings including Stainless steel

Door handle,door lock approved make and quality,

hinges and barrol bolt etc. as approved by the

Engineer. (01No) 2.7 m2

E05 Supply and fixing of Door type ''D3'' overall size 3' 6''

x 7' 0'' high Aluminium framed glazed door sash and

all as per detailed drawing . Rate to include necessary

fittings including Stainless steel Door handle,door

lock approved make and quality, hinges and barrol

bolt etc. as approved by the Engineer. (05No) 11.5 m2

E06 - Ditto - upper floor (03 nos) 6.9 m2

Page 30 of 61

Page 35: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

E07 Supply and fixing of Door type ''D4'' overall size 2' 9''

x 7' 0'' high Aluminium framed door with sash bottom

part aluminium cladding and upper part pin head

glazed as approved by the Engineer in ground floor

bath room a. Rate to include necessary fittings

including door handle, door lock of approved make

and quality, hinges and barrol bolt etc. (02 Nos) 3.8 m2

E08 - Ditto - upper floor (01 nos) 1.9 m2

E09 Supply and fixing of Door type ''D5'' overall size 2' 6''

x 6' 9'' high Aluminium framed door with sash bottom

part aluminium cladding and upper part pin head

glazed as approved by the Engineer in ground floor

bath room a. Rate to include necessary fittings

including door handle, door lock of approved make

and quality, hinges and barrol bolt etc. as approved

by the Engineer. (05No) 7.9 m2

E10 - Ditto - upper floor (02 nos) 3.2 m2

E11 Window type ''W'' overall size 8' 0'' x 6' 0''

Aluminum framed glazed window with louvers above

all as per detailed drawing and including all necessary

fittings. as approved by the Engineer. (02 No) 9.0 m2

E12 Window type ''W1'' overall size 6' 0'' x 6' 0''

Aluminum framed glazed window with louvers above

all as per detailed drawing and including all necessary

fittings. as approved by the Engineer. (09 No) 31.0 m2

E13 - Ditto - upper floor (08 nos) 26.8 m2

E14 Window type ''W2'' overall size 4' 0'' x 6' 0''

Aluminum framed glazed window with louvers above

all as per detailed drawing and including all necessary

fittings. as approved by the Engineer. (03 No) 6.7 m2

Page 31 of 61

Page 36: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

E15 Window type ''SW'' overall size 4' 0'' x 6' 0''

Aluminum framed glazed sliding window with louvers

above all as per detailed drawing and including all

necessary fittings. as approved by the Engineer. (02

No) 4.5 m2

E16 Supply and fixing of Fanlight type "F1" overall size 2'

6'' x 3' 6'' Aluminium framed glazed fanlight with

louvers, all as per detailed drawing and including all

necessary fittings. (01No ) 0.9 m2

E17 - Ditto - upper floor (01 nos) 0.9 m2

E18 Supply and fixing of Fanlight type "F2" overall size 2'

0'' x 3' 0'' Aluminium framed glazed fanlight with

louvers, all as per detailed drawing and including all

necessary fittings. ( 04 No) 2.3 m2

E19 - Ditto - upper floor (02 nos) 1.2 m2

E20 Supply and fixing of Fanlight type "FG1" overall size

5' 0'' x 6' 0'' Aluminium framed fixed glazed window

with louvers above, all as per detailed drawing and

including all necessary fittings. ( 01 No) 2.8 m2

E21 Supply and fixing of Fanlight type "FG" overall size

3' 0'' x 6' 0'' Aluminium framed fixed glazed window

with louvers above, all as per detailed drawing and

including all necessary fittings. ( 02 No) 3.4 m2

E22 - Ditto - upper floor (01 nos) 1.7 m2

Aluminium partition

Note

All Aluminium partition extrusions shall be

powder coated and of approved colour (white

colour) , Total thickness of 60 - 80 microns.

All glass should be 5mm thick St Gobain float glass

Samples to be submitted and obtained approval

from the Engineer .

Page 32 of 61

Page 37: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

E23 Supply , fabricating & installation of new partition

with powder coated Aluminium frame and 5mm thick

plain glass .(ground floor) 56.0 m2

E24 -Ditto - upper floor 38.0 m2

F/- ROOFING WORK

Roof covering

F01 Supply and installing of Zinc Aluminium colour

bonded AZ -150 roofing sheets(not less than 0.5mm

total coated thickness, Tile roofin gprofile) laid on

steel frame work .(Frame work measured separately.) 224.0 m2

F02 Supply and laying of double sided foil for thermal

protection laid including 50mm x50mm GI mesh fixed

to the roof frame. 224.0 m2

Frame work

F03 Supply , fabricating and fixing of 2/3''x3'' angle iron

trusss fixed on brick wall with rag bolts in

1:2:4(20mm) 225 x 225 x 200mm concrete pad. as per

detail drawing No CEYPET / ENG / SK / .......... Rate

shall include for necessary brackets and cleats to

welded / fixed as requred and one coat of primer and

two coats of enamel paint. 15.0 m

F04 Supply and fixing of 6'' lip channel purlins including

necessary connection (welding/bolting) as per detail

drawing No CEYPET / ENG / SK / .......... Rate shall

include for one coat of primer and two coats of

enamel paint. 183.0 m

F05 Supply and fixing 10'' x 1'' timber valance board

(Ginisapu timber or approved equivalent). Rate to

include one coat of wood primer and two coats of

enamel paint. 14.0 m

TOTAL DOORS AND WINDOW WORK CARRIED TO SUMMARY

Page 33 of 61

Page 38: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

F06 Supply and fixing 10'' x 1'' timber bardge board

(Ginisapu timber or approved equivalent). Rate to

include one coat of wood primer and two coats of

enamel paint. 14.0 m

F07 Supply and fix Colour Bonded Zinc Aluminium 9'' x 1'

0'' gutters with a coated thickness of 0.47 mm all as

per manufactures specification and details drawings in

roof. Rate shall include for all necessary specials.

(down pipes measured separately) 14.0 m

F08 Supply and fixing of colour Bonded Zinc Aluminium

down pipe 6'' x 6'' square type with a coated thickness

of 0.47mm fixed with G.I. brackets complete with

specials and embeded in concrete column connection

to external rain water canales. 25.0 m

Flashing

F09 Supply and fixing 0.47mm thick Zn / Al plain sheet

flashing bent to shape(50mm embedded to wall). The

width of the flashing should not be less than 600mm. 18.6 m2

Strip ceiling (I - panel Ceiling )

F10 Supply and installing of strip ceiling ( ''I '' panel

ceiling ) as per the specification. 186.0 m2

Features : Wearing resistance , water proof , flame

retarding , aging resistance , smoothness , flatness and

mothproof.

Proof : Light in weight and easy to install.

Content : PVC - 45% , CaCo3 -55%

Surfaces : High quality laminated

Width : 8 inch

Length : 10 feets

Thickness : 7.5mm , 8mm

weight : 3.0 - 3.5 kg per square meter

TOTAL ROOF WORK CARRIED TO SUMMARY

Page 34 of 61

Page 39: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

G/- PLUMBING AND DRAINAGE WORK

Cold water installation

G01 2'' diameter Grade 1000 uPVC solvent socketed pipes,

with necessary specials, laid in trenches not exceeding

1 m deep,. 12.0 m

G022'' diameter Grade 1000uPVC solvent socketed pipes,

with necessary specials, laid in chases and clipped in

brick / concrete surface in internal distribution system.12.0 m

G03 - ditto - 11/2'' diameter 12.0 m

G04 1'' diameter Grade 1000 uPVC solvent socketed pipes

with and including all necessary specials, laid in

trenches not exceeding 1 m deep in garden water

supply network. 12.0 m

G05 1'' diameter Grade 1000 uPVC solvent socketed pipes

with and including all necessary specials, laid in

chases and clipped in brick / concrete surface in

internal distribution system. 12.0 m

G06 3/4'' diameter Grade 1000 uPVC solvent socketed

pipes with and including all necessary specials, laid in

chases and clipped in brick / concrete surface in

internal distribution system. 12.0 m

G07 1/2'' diameter Grade 1000 uPVC solvent socketed

pipes with and including all necessary specials, laid in

chases and clipped in brick / concrete surface in

internal distribution system. 30.0 m

Soil & Waste water installation

G08 4'' diameter soil pipe, grade 600, rubber ring socketed

uPVC, with all necessary specials, laid from manhole

including all necessary excavation not exceeding 1.5m

deep, earth work and 375mm x 375mm grade 15

concrete backing and haunching at minimum 1.0m

intervals. 60.0 m

Page 35 of 61

Page 40: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

G09 11/2'' diameter soil pipe (grade 600 uPVC) with all

necessary specials, laid from manhole including all

necessary excavation not exceeding 1.0m deep

including earth work . 60.0 m

Sanitary Fittings and Toilet Accessories

Note

(a) Contractor to purche all items from the agent

with agent warranty and invoice.

Samples and technical data / catalogue to be

submitted and obtained approval from the client

before purchasing the materials.

(b) All taps and accessories to be ' HUIDA '

(Reform Ceramic (pvt) Ltd) , or ' HAGAR '

(Rajabdeen & sons Ltd)

(c) All sanitary fittings to be following or

equivalent American standard (Agent Key Group

Three (private ) Ltd, Rocell (Agent Royal Ceramic

Lanka PLC ) or Cotto (Agent Rifirm international

(Pvt) Ltd)

(d) All connections to appliances shall be through

20mm diameter cromium plated angle valve (Agent

Raniyo (Pvt) Ltd, Peglar No -1 or equivalent) and

connected to fittings with 20mm diameter cromium

plated flexible pipe (Amirican standard ,

manufactured Thailand or equivalant ) approved

by Engineer.

G10 Supply and fix 3/4'' thick polished granite venity top

with bull nose edge ( Approx. size 6' 0'' x 2' 0'') and

fixing 02 nos ceramic wash basin (white ) 22'' x 15''

overall size with 20mm dia cromium plated piller tap

and other necessary accessaries including water supply

and waste water connection . All complete to working

order . Rate shall include for macking opening in the

granite top for installation of 02 Nos wash basin.

Sample to be approved by the Engineer. (Prime cost

of wash basin with fitting -Rs 15,000 /= per 1 No)

1.0 nr

Page 36 of 61

Page 41: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

G11 Supply and fix 3/4'' thick polished granite venity top

with bull nose edge ( Approx. size 3' 6'' x 2' 0'') and

fixing 01 no ceramic wash basin (white )22'' x 15''

overall size with 20mm dia cromium plated piller tap

and other necessary accessaries including water supply

and waste water connection . All complete to working

order . Rate shall include for macking opening in the

granite top for installation of 01 no wash basin.

Sample to be approved by the Engineer. (Prime cost

of wash basin with fitting -Rs 15,000 /= per 1 No) 2.0 nr

G12 - Ditto - 1st floor 1.0 nr

G13 Supply and installation pedestal type ceramic wash

basin (white )22" x 15 " overall size with 20mm dia

cromium plated piller tap and other necessary

accessaries including water supply and waste water

connection . All complete to working order.(Prime

cost of wash basin with fitting -Rs 15,000 /= per No) 2.0 nr

G14 Supply and installation of ceramic close couple water

closet with " P " or "S" trap duel flush complete with

flexible connection and angle valves to the working

order.(Prime cost of water closet with fittings -Rs

18,000 /= per No) 5.0 nr

G15 - Ditto - 1st floor 2.0 nr

G16 Supply and installation of ceramic urinars with plush

valve complete with flexible connection to the

working order.(Prime cost of water closet with

fittings -Rs 18,000 /= per No) 2.0 nr

G17 Supply and Installation of Cromium plated 1/2'' dia

bib tap .(Prime cost of bib tap -Rs 1750 /= per No) 5.0 nr

G18 - Ditto - 1st floor 2.0 nr

G19 Supply and fixing of bidet shower.(Prime cost of

bidet shower with fittings - Rs 2500 /= per No)

.(Ground floor) 5.0 nr

Page 37 of 61

Page 42: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

G20 - Ditto - 1st floor 2.0 nr

G21 Supply and installation of 100mm dia stainless steel

shower rose.(Prime cost of shower rose with fittings -

Rs 2500 /= per No) 1.0 nr

G22 Supply and installation of stainless steel towel rail

.(Prime cost of stainless steel towel holder with

fittings -Rs 2900 /= per No) 2.0 nr

G23 - Ditto - 1st floor 2.0 nr

G24 Supply and installation of stainless steel coat

hooks.(Prime cost of stainless steel coat hook. - Rs

1000 /= per No) (Ground floor) 6.0 nr

G25 - Ditto - 1st floor 4.0 nr

G26 Supply and installation of stainless steel soap tray

.(Prime cost of stainless steel soap tray with fittings

Rs 2750 /= per No) 6.0 nr

G27 - Ditto - 1st floor 4.0 nr

G28 Supply and installation of mirror size 600mm x

400mm plain glass mirror with chromium plated clips

and plugs to be fixed to wall above wash basin in

bath rooms .(Prime cost of mirror - Rs 3750 /= per

No) 3.0 nr

G29 - Ditto - 1st floor 3.0 nr

Valves

G30 Remove existing Angle value and supply and fixing of

new Angle value in removed locationand all complete

to working order.(quality to be approved by the

Engineer)(ground floor) 9.0 nr

G31 - Ditto - 1st floor 8.0 nr

Page 38 of 61

Page 43: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

G32 Supply and installation of 20mm dia concealed

valve.(Prime cost of 20mm dia concealed valve -Rs

2000 /= per No) 1.0 nr

Builders works

G33 150 mm x 150 mm x 125 mm deep injection moulded

PVC floor trap (catchpit) with stainless steel grating

on top and set in concrete and connected to waste

water lines. 6.0 nr

G34 - Ditto - 1st floor 2.0 nr

G35 Waste water gully internal size 225x225 x300mm

deep in concrete floor including 130mm thick concrete

screed (1:3) rendering to all exposed surfaces and

finished smooth with neat cement float. Rate to

include for necessary earthwork, grouting etc. 6.0 No

G36 Sewer manhole 450x 450mm and average depth not

exceeding 500mm internally with and including all

necessary excavation, earthwork, 160mm thick grade

'20 concrete base, one brick thick brick walls, cement

plasterwork, grade 20 rebated concrete pad on 10mm

diameter tor steel bars at 20 mm crs. Bothways with

bothways with lifting hooks. 5.0 No

G37 1200mm dia and 2400mm deep (internal) waste water

soakage pit. The pit wall to be built in 225 brick work

in cement with 1:5 alternate open joints as directed.

rate to include 125mm thick concrete cover slab 1:2:4

(20)r/f with 12 mm dia tor bars at 150mm crs.

bothways, and 16mm thick cement rendering 1:3

finish smooth. provide for in to 225x225mm concrete

1:2:4 (20mm) rebated pad to accommadate the cover 1.0 No

G38 300 x 300 x 450mm deep gully in 50mm thick 1:2:4

Concrete rendering all exposed surfaces finish smooth

with neat cement float Rate to include for necessary

earthwork and steel grating to cover the gully 2.0 No

Page 39 of 61

Page 44: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

G39 1800x900x1650 ( internal )septic tank with

1200x900x1650 ( internal ) attached soakage pit as

shown in drawing. The septic tank base to be in

150mm thick concrete 1:2:4( 20) r/f with 10mm dia.

Tor bars at 200 crs. bothways. 225mm brick work in

cement 1:5. 75mm thick R.C.C. cover slab reinforced

as shown in drawing including cement rendering 1:3

finished smooth. 225x225 R.C.C. ring beam under

soakage pit, 2 Nos.100mm dia. G.S.W. tees and 10mm

thick cement rendering 1:3 with 5% pudlo to all

internal surfaces of septic tank finished smooth. Rate

to include for excavation, back filling and disposing

surplus earth as directed. 1.0 No

G40 Supply and install plastishell 2000 Litr. water tank

over the concrete toilet roof slab approved by the

engineer. 1.0 No

H/- ELECTRICAL INSTALLATION

Rates in Bill of Quantities shall include all necessary

materials (Cables, conduits, PVC sunk box, bulbs,

switches etc.) and labour required to complete the

electrical installation to good working order.

Except where specifically stated, all costs associated

with provision of all holes, openings, chases, ducts

and other builders' work required for installation and

make them good, shall be included in the rates.

Where reference is made to certain manufactures'

products and items identified by registered trade

marks, has been done for the sole purpose of defining

and establishing standards of quality and performance

and not with the intention of restricting the

procurement of material or fitting to a particular

manufacturer. However all equipment and material

should meet the BS or an equivalent standard.

Testing and commissioning of the electrical

installation is to be carried out by the contractor and

inspection report submitted according to the

requirements of the power supply Authority.

TOTAL PLUMBING WORK CARRIED TO SUMMARY

Page 40 of 61

Page 45: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

Electrical Items (MCB,RCCB etc.) should be of

European/Japanese origin or to the BS or equivalent

and items without an accredited agent in Sri Lanka

shall not be accepted. Guarantee cards(Fans etc.)

should be provided from Accredited agent before

installation.

All the quantities given here are approximated values

and Quantities may change with the actual installation

at the site.

All types of fittings, materials, painting and finishes

shall be approved by the Engineer prior to installation.

All panel boards and consumer units should have wire

numbering and a laminated circuit diagram should be

pasted on the inside surface of the door.

H/01 Main Distribution Board 1.0 No

Supply and installation of Main Distribution Board

(MDB) complete with powder coated 2mm sheet steel

enclosure with lockable doors. All panel boards

should have wire numbering and a laminated circuit

diagram should be pasted on the inside surface of the

panel board.

Main Distribution Board shall be complete with

necessary over load protection (adjustable current and

time), short circuit protection, surge protection, earth

fault protection comprising all other required

accessories.

Surge protection for Main Distribution Board shall be

provided at main busbars, with proper earthing and

necessary protection.

Make of MCCBs and MCBs, etc shall be ABB,

Terasaki, Merlin Gerin or equivalent make approved

by the Electrical Engineer.

02 No. 63A, 4P Automatic mains failure (AMF) and

automatic load transfer switch (ATS) switchgear for

automatic transfer of load from CEB supply to Diesel

Generator and vice versa

All control circuits, control cables, contractors, relays

etc. shall be included

Incoming Circuit Breakers

01 No. 63A, 3P+N Link MCCB (25kA fault level)

Outgoing Circuit Breakers

02 Nos. 32A, 3P+N link MCB

Page 41 of 61

Page 46: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

01 No. 40A 3P+N link

01 No. 20A 3P+N link MCB

1 set of Voltage/Current surge arrestors for three phase

& neutral (3P+N)

01 No. of Earth Fault Relay (0.3A to 1A) with shunt

trip to trip Main Incoming Breaker.

2 Sets of indicator bulbs for three phases with

protection.

02 Nos. of Ammeters for 3 Phases (0 - 100A) with

selector switch

02 No. of Voltmeters ( 0 - 500V) with selector switch

01 No. of Digital Analyzer to display V, A, KWh,

KVA, PF

All internal connections including 100A Live and

Neutral bus bars, Earth bar etc.

Note: For 3P+N MCCB, the Neutral Link must be

mounted adjacent to the MCCB.

Equipment to be to the BS and European/Japanese

make

H/02 Floor Distribution Board (FDB)

Supply and installation of switch gear cubicle made

out of (1.5mm thickness) sheet steel (IP54) stove

enameled or powder coated for the finish with one coat

of primer to the approval of the engineer with following

equipment. All cable terminations to the panels should be

properly galnded or suitablely fixed to the panel enclosure

as approved by engineer.

H/02.1 FDB-GF 1.0 No

01 No. 40A 4-pole MCB

01 Nos. 40A, 4-pole RCCB, 30mA sensitivity

01 Nos. 32A 3-pole ISOLATOR

01 No. 40A 2-pole ISOLATOR

05 No. 20A 2-Pole ISOLATOR

1 Set of Live & Neutral bus bars

Earth Bar

01 Nos Volt meter & Ammeter with selector switch

and protection.

1 Set of indicator bulbs for three phases with

protection.

All internal connections.

Page 42 of 61

Page 47: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

Equipment to be to the BS and European/Japanese

make

H/02.2 FDB-FF 1.0 No

01 No. 32A 4-pole MCB

01 Nos. 40A, 4-pole RCCB, 30mA sensitivity

01 Nos. 32A 3-pole ISOLATOR

02 No. 32A 2-pole ISOLATOR

1 Set of Live & Neutral bus bars

Earth Bar

01 Nos Volt meter & Ammeter with selector switch

and protection.

1 Set of indicator bulbs for three phases with

protection.

All internal connections.

Equipment to be to the BS and European/Japanese

make

H/02.3 FDB-Work shop

01 No. 32A 4-pole MCB 1.0 No

03 No. 32A 2-pole ISOLATOR

02 No. 20A 4-pole ISOLATOR

1 Set of Live & Neutral bus bars

Earth Bar

01 Nos Volt meter & Ammeter with selector switch

and protection.

1 Set of indicator bulbs for three phases with

protection.

All internal connections.

Equipment to be to the BS and European/Japanese

make

H/03 Consumer units

Supply and installation of wall mounted/ sunk type

switch gear cubicle made out of polycarbonate

enclosure to the approval of the engineer with

equipments as specified in each board.

Equipment to be to the BS and European/Japanese

make

H/03.1 Cu-01 1.0 No

01 No. 40A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

Page 43 of 61

Page 48: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

05 No. 6A 1-Pole MCB 6kA

01 No. 10A 1-Pole MCB 6kA

04 No. 10A 1-Pole MCB 6kA

02 No. 20A 1-Pole MCB 6kA

10 Nos of ways 6-32A, 1-Pole MCB 6kA

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/03.2 Cu-02 1.0 No

01 No. 20A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

03 No. 6A 1-Pole MCB 6kA

01 No. 16A 1-Pole MCB 6kA

02 No. 20A 1-Pole MCB 6kA

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/03.3 Cu-03 1.0 No

01 No. 20A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

02 No. 6A 1-Pole MCB 6kA

01 No. 16A 1-Pole MCB 6kA

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/03.4 CU-04 1.0 No

01 No. 20A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

03 No. 6A 1-Pole MCB 6kA

01 No. 16A 1-Pole MCB 6kA

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Page 44 of 61

Page 49: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

Equipment to be to the BS and European/Japanese

make

H/03.5 CU-05 1.0 No

01 No. 20A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

02 No. 6A 1-Pole MCB 6kA

01 No. 16A 1-Pole MCB 6kA

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/03.6 CU-06 1.0 No

01 No. 20A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

02 No. 6A 1-Pole MCB 6kA

01 No. 16A 1-Pole MCB 6kA

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/03.7 CU-07 1.0 No

02 No. 32A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

01 No. 6A 1-Pole MCB 6kA

01 No. 10A 1-Pole MCB 6kA

04 No. 16A 1-Pole MCB 6kA

01 Nos Volt meter & Ammeter with selector switch

and protection.

1 Set of indicator bulbs for three phases with

protection.

1 Set of Live & Neutral bus bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/03.8 CU-08 1.0 No

01 No. 32A, 2-pole MCB 10kA

01 No. 40A, 2-Pole RCCB 30mA

01 No. 6A 1-Pole MCB 6kA

04 No. 16A 1-Pole MCB 6kA

01 No. 20A 1-Pole MCB 6kA

Page 45 of 61

Page 50: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/3.9 CU-10 1.0 No

01 No. 32A, 4-pole MCB 10kA

03 No. 32A, 2-pole MCB 10kA

03 No. 40A, 2-Pole RCCB 30mA

06 No. 6A 1-Pole MCB 6kA

04 No. 16A 1-Pole MCB 6kA

05 No. 20A 1-Pole MCB 6kA

1 Set of Live and neutral Bus Bars

Earth Bar

All internal connections

Equipment to be to the BS and European/Japanese

make

H/4 Cables

H/4.1 Supply & installation of Main incoming cable 4x1Cx16

mm2 CU/PVC/PVC cable from CEB meter to MDB

5.0 m

H/4.2 Supply & installation of 4x1Cx10 mm2 CU/PVC/PVC

cable from MDB to FDB-GF

7.0 m

H/4.3 Supply & installation of 4x1Cx10 mm2 CU/PVC/PVC

cable from MDB to FDB-FF

8.0 m

H/4.4 Supply & installation of 4Cx1x6 mm2 CU/PVC/PVC

armoured cable from MDB to FDB-work shop

36.0 m

H/4.5 Supply & installation of 2Cx1x6 mm2 CU/PVC/PVC

cable from FDB-GF to CU-01

6.0 m

H/4.6 Supply & installation of 2Cx1x6 mm2 CU/PVC/PVC

cable from FDB-work shop to CU-07, CU-08

12.0 m

H/4.7 Supply & installation of 2Cx1x4 mm2 CU/XLPE/PVC

cable from FDB-GF to CU-02, CU-03, CU-05, CU-06

75.0 m

H/4.8 Supply & installation of 2Cx1x4 mm2 CU/XLPE/PVC

armoured cable from FDB-GF to CU-04

21.0 m

Page 46 of 61

Page 51: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

H/4.9 Supply & installation of 2Cx1x6 mm2 CU/PVC/PVC

cable from FDB-FF to CU-10

8.0 m

Earth Cables

H/4.10 Supply and Installation of 16mm2 Cu/PVC Earth cable

from Earth Bar of MDB to earth pipe

6.0 m

H/4.11 Supply and Installation of 10mm2 Cu/PVC Earth cable

from MDB to FDB-GF, FDB-FF

15.0 m

H/4.12 Supply and Installation of 6mm2 Cu/PVC Earth cable

from FDB-GF to CU-01 & from FDB to CU-10

32.0 m

H/4.13 Supply and Installation of 4mm2 Cu/PVC Earth cable

from FDB-GF to CU-02, CU-03, CU-05, CU-06

75.0 m

H/5 Ground Rod (Earth pipe)

H/5.1 Supply of galvanised iron pipe of diameter 50mm and

length 2 metres complete with brass clamp, nut, bolt

and washers to fix the main Earth wire.

1.0 no

H/5.2 Installation of Item No. 5.1 above with all necessary

accessories and cable connections

1.0 no

H/6 Light Fittings

H/6.1 Type A Light Fitting

Supply of 1x36W single fluorescent batten lamp

enclosed in powder coated enameled mild steel (Zinc

coated) sheet, thickness not less than guage 24, colour

brilliant white, ceiling mounted/GI chain suspended

fitting with wraparound type prismatic diffuser

complete with holders, choke, starter and a power

factor correction capacitor.

5.0 nos

H/6.2 Type B Light Fitting

Supply of 12 Watt squre type LED Panel lamp fitting

enclosed in white enameled sheet (steel) ceiling

mounted/ceiling recessed with diffuser complete with

all required accessories

14.0 nos

H/6.3 Type C Light Fitting

Supply of 3x9 Watt squre type(2'x2') LED Panel lamp

fitting enclosed in white enameled sheet (steel) ceiling

mounted/ceiling recessed with diffuser complete with

all required accessories

47.0 nos

Page 47 of 61

Page 52: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

H/6.4 Type D Light Fitting

Supply of Sofit mount light fitting made out of

cylindrical enameld steel cover & internal reflector

complete with 11 watt LED bulb and all other

accessories

10.0 nos

H/6.5 Type K Light Fitting

Supply of weather proof Bracket light fitting (wall

mounted) made out of glass complete with 11 watt

LED bulb

18.0 nos

H/6.6 Type W Light Fitting

Supply of Pendant light fitting made out of glass

complete with 15 watt LED bulb

5.0 nos

H/6.7 Type P Light Fitting

Supply of mirror light fitting made out of glass

complete with 8 watt LED bulb

5.0 nos

H/6.8 Type Q Light Fitting

Supply of stair way light fitting made out of glass

complete with 2x8 watt LED bulb

2.0 nos

H/6.9 Type R Light Fitting

Supply of street light fitting with arm made out of

polycarbonate complete with 100 watt LED bulb

6.0 nos

H/6.10 Type S Light Fitting

Supply of 1" dia. High Bay light fitting made out of

enamaled steel cover and aluminium reflector

complete with 250 watt Mercury vapour bulb and all

other acessories required

6.0 nos

H/6.11 Type T Light Fitting

Supply of weather proof bulk head light fitting

complete with 11 watt CFL bulb

5.0 nos

H/6.12 Type U Light Fitting

Supply of weather proof Bollard light fitting of clear

acrylic globe and complete with 15 watt CFL bulb

2.0 nos

H/7 Wiring of Lamp Fittings

Page 48 of 61

Page 53: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

H/7.1 Wiring (including supply of all materials & a switch)

of the above light points using approved type PVC

insulated PVC sheathed 2x1mm2 CU/PVC/PVC cable

drawn through recessed PVC conduits.

114.0 nos

H/8 Wiring of Two way Lamp Fittings

H/8.1 Wiring (including supply of all materials & a two way

switch) of the above light points using approved type

PVC insulated PVC sheathed 2x1mm2 CU/PVC/PVC

cable drawn through recessed PVC conduits.

2.0 nos

H/9 Fans

Ceiling fans

H/9.1 Supply & installation of 56" sweep ceiling fan

(European/Japanese make),minimum 165 CMM,

complete with regulator, fan hook, extension rod &

attachment - Guarantee cards should be provided

from accredited agent.

11.0 nos

Wall fans

H/9.2 Supply and installation of dia. 400mm wall mounted

fan complete with regulator (cord for regulator) and all

other accessories required - Guarantee cards should be

provided from accredited agent & approved by

Engineer before installation.

8.0 nos

H/10 Wiring for fans

Ceiling fans

H/10.1 Wiring (including supply of all material, earth wire &

switch) of the above ceiling fans using approved type

2x1 mm2, CU/PVC/PVC cable & 2.5 mm2 Cu earth

wire drawn through securely fixed consealed PVC

conduits.

11.0 nos

Wall fans

H/10.2 wiring with 2x 1 mm2 CU/PVC/PVC cable &

2.5mm2 Cu earth insulated cable & 5A switched

socket outlet & controlled by regulator as indicated in

the single line diagram.

8.0 nos

Note

Guarantee cards should be provided with the serial

number of each Ceiling & wall fan.

H/11 Emergency Lamps

Page 49 of 61

Page 54: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

H/11.1 Supply and installtion of wall mounted type

emergency lamp fitting with 2 nos of 9W fluorscent

lamps; polycarbonate cover and battery pack of

minimum 3hrs. Duration with both fluorscent lamps

1.0 nos

H/12 Wiring for Emergency Lamps

H/12.1 Wiring(including supply of all material required) of

13A socket outlet using approved type 1.5 mm2

Cu/PVC/PVC 2C cable & 2.5mm2 earth cable drawn

through securely fixed concealed PVC conduit

1.0 nos

H/13 Socket Outlets

H/13.1 Supply of 13 Amp, 250 volt, flush type, socket outlet

with switch

66.0 nos

H/13.2 Installation of Item above wired with 2.5 mm2 PVC

insulated cable as indicated in single line diagram with

all necessary accessories.

66.0 nos

H/13.3 Supply of 15 Amp, 250 volt, flush type socket outlet

with switch.

12.0 nos

H/13.4 Installation of Item above wired with 2.5 mm2 PVC

insulated cable as indicated in single line diagram with

all necessary accessories.

12.0 nos

Note

Installation cost also includes cost of cables, 2.5 mm2

earth wire, conduits etc.

H/14 5 Pin Industrial Sockets

H/14.1 Supply of 5 pin 16A 3 Phase industrial socket outlet 1.0 nos

3 Pin Industrial Sockets

H/14.2 Supply of 3 pin 16A 1 Phase industrial socket outlet 5.0 Nos

H/15 Wiring of 5 Pin Industrial Socket outlets

H/15.1 Wiring(including supply of all material required) of

16A 3 phase industrial socket outlet using approved

type 4x2.5 mm2 Cu/PVC/PVC 2C cable & 2.5mm2

earth cable drawn through securely fixed concealed

PVC conduit

1.0 nos

H/16 Wiring of 3 Pin Industrial Socket outlets

H/16.1 Wiring(including supply of all material required) of

16A 1 phase industrial socket outlet using approved

type 2x2.5 mm2 Cu/PVC/PVC 2C cable & 2.5mm2

earth cable drawn through securely fixed concealed

PVC conduit

5.0 Nos

H/17 DB for 5 Pin Industrial Socket outlet

Page 50 of 61

Page 55: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

H/17.1 Supply and installation of wall mounted/ sunk type

switch gear cubicle made out of polycarbonate

enclosure to the approval of the engineer with

equipments as specified in each board.

Equipment to be the BS and European/Japanese make

01 No. 20A, 4-pole MCB 10kA 1.0 nos

01 No. 40A, 4-Pole RCCB 30mA

H/18 DB for 3 Pin Industrial Socket outlet

H/18.1 Supply and installation of wall mounted/ sunk type

switch gear cubicle made out of polycarbonate

enclosure to the approval of the engineer with

equipments as specified in each board.

Equipment to be the BS and European/Japanese make

01 No. 20A, 2-pole MCB 10kA 5.0 Nos

01 No. 40A, 2-Pole RCCB 30mA

H/19 Supplying, wiring & installation of 20A 4 Pole MCB

& 20A 4 Pole RCCB with sensitivity of 100 mA with

4 mm2 1Cx4+4.0 mm2 earth cable complete with

enclosure for the compressor

1.0 No

H/20 Supply and install yard light pole in 75mm dia.

Medium duty G.I. pipe 6m above the ground level to

fix the LED street light fitting

6.0 Nos

H/21 Chatrered Electrical Engineeer certificate for the entire

electrical installation

1.0 No

J/- FINISHES

J1Supply and laying of Homogeneous non slip tiles

(600mm x 600mm) on tile adhesives of approved

quality and design to all ground floor. Rate to include

12mm thick cement rendering 1:3 to floor before

laying tiles and dressing grooves with coloured cement

slurry after fixing tiles as directed and 100mm high

skirtings (Prime cost of a Tile Rs 1200.00 per Tile ). 280.0 m2

J2 Supply and laying of Homogeneous non slip tiles

(600mm x 600mm) on tile adhesives of approved

quality and design to all upper floor. Rate to include

12mm thick cement rendering 1:3 to floor before

laying tiles and dressing grooves with coloured cement

slurry after fixing tiles as directed and 100mm high

skirtings (Prime cost of a Tile Rs 1200.00 per Tile ). 215.0 m2

TOTAL ELECTRICAL INSTALLATION CARRIED TO SUMMARY

Page 51 of 61

Page 56: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

J3 Supply and laying of Ceramic non slip tiles (300mm x

300mm ) of approved size quality and design to toilet

floor area . Rate to include 12mm thick cement

rendering 1:3 to floor before laying tiles and dressing

grooves with coloured cement slurry after fixing tiles

as directed (Prime cost of Tile Rs 950.00 per Tile )

(ground floor) 38.0 m2

J4 Ditto upper floor bath rooms 19.0 m2

J5Supply and laying of Glazed tiles (300mm x 600mm

)of approved size and design to walls of toilets up to

1500mm height. Rate to include12mm thick cement

rendering 1:3 to wall surfaces before fixing tiles and

dressing grooves with white cement slurry after fixing

as directed. (Prime cost of a Tile Rs 400.00 per Tile ) 120.0 m

2

J6 - Ditto - upper floor bath rooms 75.0 m2

J7 15mm thick cement lime sand plaster 1:1:5 to internal

surfaces of walls and columns finished smooth with

lime putty. (ground floor) 280.0 m2

J8 -Ditto - Preparing reveals not exceeding 225mm

wide 385.0 m

J9 15mm thick cement lime sand plaster 1:1:5 to internal

surfaces of walls and columns finished smooth with

lime putty. (upper floor) 130.0 m2

J10 15mm thick cement lime sand plaster 1:1:5 to external

surfaces of walls finished semi rough with wooden

float. Rate to include preparing jambs and reveals. 130.0 m2

J11 - Ditto - upper floor bath rooms 130.0 m2

J12 15mm thick cement sand plaster 1 :5 in soffit of slab

finished smooth with lime putty. 135.0 m2

Page 52 of 61

Page 57: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

Staircase

J13 Supply and laying of Ceramic non slip tiles (300mm x

300mm ) of approved size quality and design to

staircase floor area . Rate to include 12mm thick

cement rendering 1:3 to floor before laying tiles and

dressing grooves with coloured cement slurry after

fixing tiles as directed (Prime cost of Tile Rs 300.00

per Tile ) (ground floor) 14.0 m2

J14Supply and fixing 2' 0'' wide and 2' 4'' high pantry

cupboard with 2'' x 2'' special class timber frame

treated with wood preservatives and teak timber sash

(20mm thick) . Rate to include spray painting , all

necessary fixtures and locks in pantry area. Sample to

be approved by the Engineer. (Pantry area) 4.6 m

J15 Supply and fixing stain less steel sink ( single bowl ,

single drain) on pantry top as directed. Rate to include

chromium plated swan neck tap , water supply and

waste lines and necessary fittings as approved by the

Engineer. 1.0 nr

J16 Supply and fixing of polycarbonate sheet roof with

stainless steel frame as per detail drawing.Rate to

include 02 nos 6'' x 6'' GI box post , earth work and

concreting. P S 500,000.00

TOTAL FINISHES CARRIED TO SUMMARY

Page 53 of 61

Page 58: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

ITEM DESCRIPTION QTY UNT RATE AMOUNT

BILL OF QUANTITIES

CEYLON PETROLEUM CORPORATION

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

B.O.Q. No. 2017 /KU/24

K/- PAINTING

K01 Prepare surface by scratching sand papering as

required level by approved wall putty and applying

one coat of approved primer and two coats of

emulsion paint of an approved colour and quality to

internal wall surface including reveals in ground

floor. 560.0 m2

K02 - Ditto - upper floor 375.0 m2

K03 Prepare surface by scratching sand papering as

required and levelling by an approved primer and two

coats of weather shiled paint of an approved colour

and quality to external wall surface including reveals

in ground floor. 280.0 m2

K04 - Ditto - upper floor 375.0 m2

K05 Prepare surface by scratching , Cement/ Sand plaster

filling as required and levelling by an approved

primer and two coats of weather shiled paint of an

approved colour and quality to Boundry wall

surfaces. 375.0 m2

K06 Prepare surface , Sandpapering and applying one coat

of approved primer and two coats of emulsion paint

of an approved colour and quality to all soffit of slab.

(1st floor) 315.0 m2

TOTAL PAINTING CARRIED TO SUMMARY

Page 54 of 61

Page 59: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

CEYLON PETROLEUM CORPORATION

B.O.Q. No. 2017/KU/24

SUMMARYITEM DESCRIPTION AMOUNT

A DEMOLISH WORK -Rs.

B EARTH WORK -Rs.

C CONCRETE WORK -Rs.

D MEASONRY WORK -Rs.

E DOORS AND WINDOWS -Rs.

F ROOFING WORK -Rs.

G PLUMBING AND DRAINAGE WORK -Rs.

H ELECTRICAL INSTALLATION -Rs.

J FINISHES -Rs.

K PAINTING -Rs.

TOTAL AMOUNT -Rs.

LESS DISCOUNT RS.

SUB TOTAL I RS.

ADD NBT (…….%) RS.

SUB TOTAL II

ADD VAT (…….%) RS.

GRAND TOTAL RS.

Total amount in words :-………………………………………………………………………………………

…………………………………………………………………………………………………………………

……………..

Date

BILL OF QUANTITIES

JOB: MODIFICATION TO REGIONAL OFFICE BUILDING AT KURUNEGALA.

Signature of Tenderer

…………………………….

Name of Tenderer :- ………………………………………………………………………………………….

VAT Registration No :- ……………………………………………………………………………………….

C:\Lalith\New Head office\Copy of Kurunegala_20171208074635.513_X\summary Page 55 of 61

Page 60: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Page 56 of 61

Section - 8

DRAWINGS

Note :

Insert here a list of Drawings

Page 61: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala - ip Page 57 of 61

Section – 8

8.0 DRAWINGS

8.1 CEYPET /ENG/0563A - Detail of Office Building

8.2 CEYPET /ENG/0563B - Detail of Area office Building

Page 62: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Page 58 of 61

Modification to Regional Office Building at Kurunegala - ip

SECTION – 9

STANDARD FORMS [BID]

BID SECURITY

Page 63: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala - ip Page 59 of 61

Notes on Standard Forms :

Bidders shall submit the completed Form of Bid Security/Bid Securing

Declaration as appropriate in compliance with the requirements of the bidding

documents.

Bidders should not complete the Form of Agreement at the time of preparation of

bids.

The successful bidder will be required to sign the Form of Agreement, after the

award of contract.

Any corrections or modifications to the accepted bid resulting from arithmetic

corrections, acceptable deviations, or quantity variations in accordance with the

requirements of the bidding documents should be incorporated into the Agreement.

The Form of Performance Security, Form of Advance Payment Security and Form

of Retention Money Guarantee should not be completed by the bidder s at the time

of submission of bids.

The successful bidders will be required to provide these securities in compliance

with the requirements herein or as acceptable to the Employer.

Page 64: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Page 60 of 61

Modification to Regional Office Building at Kurunegala - ip

FORM OF BID SECURITY

[this Guarantee form shall be filled in accordance with the instructions indicated in brackets]

------------------------------------------------------------------------------------------------------- [insert issuing bank’s

name, and address of issuing branch or office]

Beneficiary: ------------------------------------------------------------------------------------------------------ [insert

(by PE) name and address of Employer]

Date: ---------------------------- [insert (by issuing bank) date]

BID GUARANTEE No.: -------------------------- [insert (by issuing bank) number] We have been

informed that ------------------------------------------------------------------------------ [insert (by issuing bank)

name of the Bidder] (hereinafter called "the Bidder") has submitted to you its bid dated ------------------

-[insert (by issuing bank) date] (hereinafter called "the Bid") for the execution of [insert name of

Contract] under Invitation for Bids No. -------------- [insert IFB number] (“the IFB”).

Furthermore, we understand that, according to your conditions, Bids must be supported by a Bid

Guarantee.

At the request of the Bidder, we ----------------------------------------------- [insert name of issuing bank]

hereby irrevocably undertake to pay you any sum or sums not exceeding in total an amount of -----------

-------- [insert amount in figures] ---------------------------------------------------- [insert amount in words]

upon receipt by us of your first demand in writing accompanied by a written statement stating that the

Bidder is in breach of its obligation(s) under the bid conditions, because the Bidder:

(a) has withdrawn its Bid during the period of bid validity specified; or

(b) does not accept the correction of errors in accordance with the Instructions to Bidders

(hereinafter “the ITB”) ; or

(c) having been notified of the acceptance of its Bid by the Employer during the period of bid

validity, (i) fails or refuses to execute the Contract Form, if required, or (ii) fails or refuses to

furnish the Performance Security, in accordance with the ITB.

This Guarantee shall expire: (a) if the Bidder is the successful bidder, upon our receipt of copies of the

Contract signed by the Bidder and of the Performance Security issued to you by the Bidder; or (b) if

the Bidder is not the successful bidder, upon the earlier of (i) the successful bidder furnishing the

performance security, otherwise it will remain in force up to ---------------- (insert date)

Consequently, any demand for payment under this Guarantee must be received by us at the office on or

before that date.

___________________________________________

[signature(s) of authorized representative(s) ]

Page 65: FOR MODIFICATION TO REGIONAL OFFICE BUILDING …ceypetco.gov.lk/wp-content/uploads/B072018.pdf · Standard Bidding Document for Procurement of Works, ICTAD Publication No. ICTAD/SBD/01,

Modification to Regional Office Building at Kurunegala - ip Page 61 of 61

Check List for Bidders

Bidders are advised to fill the following table:

SIGNATURE OF THE BIDDER

ITEM ITB

Clause

YES

(tick)

REFERENCE

Form of Bid

Addressed to the Employer ?

18

Completed?

18

Signed ?

18

Bid Security

Addressed to the Employer?

16

Format as required ?

16

Issuing Agency as specified ?

16

Amount and currency as requested?

16

Validity 28 days beyond the validity of Bid

16

Qualification Information

All relevant information completed? 4

Signed ?

4

Addendum

Contents of the addendum (if any)

Taken into account ?

10

BID package

All the documents given in ITB Clause 12

enclosed in the original and copy?

12

ITB Clause 19 followed before

Sealing the Bid Package?

19