Baseline CHSM6610P SeriesBaseline CHSM6610P/HV Series
Crystalline PV Module
With innovational 4-busbar cellsUnique PERC technology with optimized module process
CHSM6610P max system voltage 1000V standard, CHSM6610P/HV max system voltage 1500V standard
0/+5 Wp
- 0.407%/K
+0.049%/K
- 0.000%/K
- 0.408%/K
- 0.310%/K
43±2°C
Warranted power output STC (Pnominal)
Rated voltage (Vmpp) at STC
Rated current (lmpp) at STC
Open circuit voltage (Voc) at STC
Short circuit current (Isc) at STC
Module effi ciency
Rated output (Pmpp) at NOCT
Rated voltage (Vmpp) at NOCT
Rated current (Impp) at NOCT
Open circuit voltage (Voc) at NOCT
Short circuit current (Isc) at NOCT
Temperature coeffi cient (Pmpp)
Temperature coeffi cient (Isc)
Temperature coeffi cient (Impp)
Temperature coeffi cient (Vmpp)
Temperature coeffi cient (Voc)
STC rated output (Pmpp)*
PTC rated output (Pmpp)**
ELECTRICAL SPECIFICATIONS
Standard sorted output
275 280 285 290
290 Wp
268.7 Wp
290 Wp
31.55 V
9.20 A
39.18 V
9.75 A
17.8%
217.5 Wp
28.56 V
7.62 A
35.79 V
8.21 A
280 Wp
259.2 Wp
280 Wp
31.20 V
8.99 A
38.69 V
9.59 A
17.2%
210.0 Wp
28.22 V
7.44 A
35.35 V
8.08 A
* Measurement tolerance +/- 3%** Estimated
Normal operating cell temperature (NOCT)
EN
6 (or 3)
15 A
Maximum system voltage (IEC/UL)
Number of diodes
Maximum series fuse rating
1000VDC / 1000VDCor 1500VDC / 1500VDC
285 Wp
263.9 Wp
285 Wp
31.38 V
9.09 A
38.94 V
9.68 A
17.5%
213.8 Wp
28.41 V
7.52 A
35.57 V
8.15 A
275 Wp
254.4 Wp
275 Wp
31.12 V
8.85 A
38.45 V
9.52 A
16.9%
206.3 Wp
28.15 V
7.33 A
35.13 V
8.02 A
IEC TS 62941
-
© Chint Solar (Zhejiang) Co., Ltd. Reserves the right of final interpretation.Specifications and designs included in this datasheet are subject to change without notice.
01-2017
RELATED PARAMETERS QUALIFICATION AND LINEAR WARRANTIES
Product standard IEC 61215, 61730 / UL1703
1st year
2nd~ 25th years
Extended product warranty
Output decline 2.5%/year performance Pmpp (STC)
Output decline 0.7%/year performance Pmpp (STC)
Number of cells / cell arrangement
Cell type
Cells dimension
Packing unit
Polycrystalline
60 / 6 x 10
6”
28 modules
10 years
MECHANICAL SPECIFICATIONS
Outer dimensions (L x W x H)
Frame technology
Module composition
Weight (module only)
Front glass thickness
Junction box IP rating
① Cable length (UL/IEC)
Cable diameter (UL/IEC)
② Maximum load capacity
Fire performance (UL/IEC)
Connector type ( UL/IEC)
Front view
Aluminum, silver anodized
Glass / EVA / Backsheet (white)
3.2 mm / 0.13 in
IP 65 (above)
900(+)/600(-)mm / 35.43/23.62 in
12 AWG / 4 mm²
2400 Pa
Type 1 (UL) or Class C (IEC)
MC4 compatible
MODULE DIMENSION DETAILS
Side view Frame cross sectionRear view
18.3 kg / 40.34 lbs
1648 x 990 x 35 mm64.88 x 38.98 x 1.38 in
① Option: 1000 mm for defined projects in advance.
990 mm/3.248 feet 35 mm/0.115 feet
35 mm/ 0.115 feet
11mm/ 0.036 feet
35 m
m/0
.115
feet
1648
mm
/5.4
07 fe
et
80.70%
0 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5
Linear Performance Wanrranty100.00%
95.00%
90.00%
85.00%
80.00%
75.00%
97.50%
ARTICLE NUMBER
Model Article No. (IEC) Article No. (UL)
(VIOLIN II) CHSM6610P-275
(VIOLIN II) CHSM6610P-280
(VIOLIN II) CHSM6610P-285
(VIOLIN II) CHSM6610P-290
(VIOLIN II) CHSM6610P/HV-275
(VIOLIN II) CHSM6610P/HV-280
(VIOLIN II) CHSM6610P/HV-285
(VIOLIN II) CHSM6610P/HV-290
Weight of packing unit (for container) 557 kg / 1228 lbs
100
mm
/0.3
28 fe
et
946 mm/ 3.104 feet
Mounting hole
6-Φ5.5 mm / 0.018 feet
16-3.5 mm x8.5 mm/ 0.011 feet x0.028 feet
6-7 mm x11.5 mm / 0.023 feet x0.038 feet
Drainage hole
Ground hole 824
mm
/2.7
03 fe
et
198
mm
/0.6
50 fe
et
600
mm
/ 1.
97 fe
et
900
mm
/ 2.
95 fe
et
② Refer to Astronergy crystalline installation manual.
200601
200641
200684
200685
500082
500084
500100
500101
200602
200642
200686
200687
500083
500085
500102
500103