  • FOLGER ADAM PRODUCT CATALOG

    4634 S. Presa Street, San Antonio, TX 78223Phone 210-533-1231 Fax 210-533-2211

    www.SouthernFolger.comSee who we are. See all we do.

  • FA Rev. 02-10 1

    For more information, please call 210.533.1231.

    Electric Locks ................................................................................................................................................................................................................... A3

    Pneumatic Locks ............................................................................................................................................................................................................. B3

    Mechanical Locks ........................................................................................................................................................................................................... C3

    Locking Devices/Door Operators ............................................................................................................................................................................... D3

    FOLGER ADAM TABLE OF CONTENTS

    TABLE OF CONTENTS

    RECOMMENDED APPLICATION GUIDELINES

    ELECTRIC LOCKS

    Introduction to Electric Locks ...................................................................................................................................................................................... A1

    Guide and Section Index .............................................................................................................................................................................................. A2

    51E Deadlatch ........................................................................................................................................................................................................... A5-A6

    51M Deadlatch .......................................................................................................................................................................................................... A7-A8

    50HBM Deadlatch .................................................................................................................................................................................................. A9-A10

    How to Specify 50HBM Locks ................................................................................................................................................................................... A11

    120E Deadlatch ..................................................................................................................................................................................................... A13-A14

    120M Deadlatch .................................................................................................................................................................................................... A15-A16

    120MC Half-Cycle Deadlatch ............................................................................................................................................................................. A17-A18

    120ED Deadbolt ................................................................................................................................................................................................... A19-A20

    120RUP Deadlatch .............................................................................................................................................................................................. A21-A22

    How to Specify 120 Locks ................................................................................................................................................................................. A23-A24

    NS400E Solenoid-Operated Deadlatches ..................................................................................................................................................... A25-A26

    NS400M and 400MC Motor-Operated Deadlatches ................................................................................................................................. A27-A28

    NS400MCD Motor-Operated Deadbolts ....................................................................................................................................................... A29-A30

    How to Specify NS400 Locks ........................................................................................................................................................................... A31-A32

    800 Gate Locks .................................................................................................................................................................................................... A33-A34

    D9300 Electric Maxi-Mortise .......................................................................................................................................................................... A35-A40

  • 2 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    FOLGER ADAM TABLE OF CONTENTS

    TABLE OF CONTENTS

    MECHANICAL LOCKS

    Introduction to Pneumatic Locks ............................................................................................................................................................................... B1

    Guide and Section Index .............................................................................................................................................................................................. B2

    NS400P Pneumatic Deadlatch .............................................................................................................................................................................. B5-B6

    120P Deadlatch ......................................................................................................................................................................................................... B7-B8

    51P Deadlatch ......................................................................................................................................................................................................... B9-B10

    Introduction to Mechanical Locks .............................................................................................................................................................................. C1

    Guide and Section Index ............................................................................................................................................................................................. C2

    10 Deadlock .............................................................................................................................................................................................................. C5-C6

    80 Deadlock ............................................................................................................................................................................................................. C 7-C8

    FGM-80 Fence Gate Lock/Mounting ................................................................................................................................................................ C9-C10

    30/30D Locks ....................................................................................................................................................................................................... C11-C12

    70 Deadlatch ......................................................................................................................................................................................................... C13-C14

    60/60K Latch and Key Operated Deadlocks ................................................................................................................................................. C15-C16

    15 Latch ........................................................................................................................................................................................................................... C17

    17 Latch ........................................................................................................................................................................................................................... C19

    17-M Latch ..................................................................................................................................................................................................................... C20

    Lock Mountings .................................................................................................................................................................................................. C21-C22

    3600 and 3800 Cremone Bolts ...................................................................................................................................................................... C23-C25

    Keeper Switches .......................................................................................................................................................................................................... C27

    D9300 Maxi-Mortise ........................................................................................................................................................................................ C29-C36

    A9300 Maxi-Mortise ......................................................................................................................................................................................... C37-C44

    9300 Lock Conversion Chart .................................................................................................................................................................................... C45

    D9300/A9300 Handing Chart ................................................................................................................................................................................... C46

    PNEUMATIC LOCKS

  • FA Rev. 02-10 3

    For more information, please call 210.533.1231.

    FOLGER ADAM TABLE OF CONTENTS

    TABLE OF CONTENTS

    Introduction to Accessories .......................................................................................................................................................................................... E1

    Guide and Section Index .............................................................................................................................................................................................. E2

    Escutcheon and Cylinder Shield ................................................................................................................................................................................. E3

    Door Pulls ......................................................................................................................................................................................................................... E4

    Prison Hinges ............................................................................................................................................................................................................. E5-E6

    No. 4-1/2FM-ICS Institutional Hinges ....................................................................................................................................................................... E7

    No. 4-1/2EH Electric Hinge ........................................................................................................................................................................................... E8

    FOLGER ADAM ACCESSORIES

    LOCKING DEVICES

    Introduction to Locking Devices ................................................................................................................................................................................ D1

    Guide and Section Index ............................................................................................................................................................................................. D2

    Locking Device/Door Operator Application Guidelines ....................................................................................................................................... D4

    Guide to Specification Preparation ............................................................................................................................................................................ D5

    102 Track and Hanger Sets ................................................................................................................................................................................... D7-D8

    2B.3 Sliding Door Locking Device ..................................................................................................................................................................... D9-D11

    3B.2 Sliding Door Locking Device .................................................................................................................................................................. D13-D15

    KR.3 Sliding Door Locking Device ................................................................................................................................................................... D17-D19

    Mechanical Control Cabinets ........................................................................................................................................................................... D21-D22

    D Corridor Door Operator ............................................................................................................................................................................... D23-D24

    D2B.3 Corridor Door Operator ....................................................................................................................................................................... D25-D26

    D3B.2 Corridor Door Operator ....................................................................................................................................................................... D27-D28

    D5B Corridor Door Operator ........................................................................................................................................................................... D29-D30

    DKR Corridor Operator ..................................................................................................................................................................................... D31-D32

    G Operators ......................................................................................................................................................................................................... D33-D34

    J Operators Sliding Fence Gate ....................................................................................................................................................................... D35-D36

    continued

  • 4 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    FOLGER ADAM TABLE OF CONTENTS

    TABLE OF CONTENTS

    Abbreviations and Finishes .......................................................................................................................................................................................... G1

    General ...................................................................................................................................................................................................................... G2-G5

    GLOSSARY

    Safety Mirrors ................................................................................................................................................................................................................ SF1

    Clothes Hook/Shelf ...................................................................................................................................................................................................... SF2

    Key Cabinet and Door Stop ....................................................................................................................................................................................... SF3

    Pistol Lockers ................................................................................................................................................................................................................. SF4

    TestPro Test Unit .................................................................................................................................................................................................. SF5-SF6

    SOUTHERN FOLGER ACCESSORIES

    FOLGER ADAM ACCESSORIES

    Head and Foot Bolts ...................................................................................................................................................................................................... E9

    523 Concealed Door Position Switch .............................................................................................................................................................. E11-E12

    534 Door Position Switch ................................................................................................................................................................................... E13-E14

    ASSW-105A Magnetic Switch ..................................................................................................................................................................................... E15

    continued from previous page

  • FA Rev. 02-10 A1

    For more information, please call 210.533.1231.

    Folger Adam brand electric locks arecharacterized by superior quality anddependability. These locks have beenproven by years of use in prisons, jailsand detention facilities throughout theworld. Each model offers a wide rangeof features to allow customized functionfor specific security requirements.

    Qualification ofSecurity Levels___________The security level of a lock or otherhardware item is determined by itsability to endure in the specificenvironment in which it is used, thelevel of supervision within the areawhere it is installed, and a variety ofother factors. The terms minimum,medium and maximum are used todescribe the relative relationship ofproducts to one another.

    Each lock on the following pages carriesa level of security designation or range.These designations are Southern FolgerDetention Equipment Companysevaluation of the ability of the productto withstand the rigors probable in thatparticular security level. Key type,cylinder type, and overall strength andconstruction of the locks have beenconsidered in reaching the publishedlevels. Because of the number ofvariables affecting security level, thedesignations in this catalog should beconsidered as guidelines only.

    Keys_____________________

    All keys are registered before shipmentto allow prompt, accurate response torequests for additional or replacementkeys. To ensure the security of your

    keying system, keys are sold only toproperly authorized buyers. Keys aresold separately and are not included inthe price of the locks.

    Prison Keys

    Southern Folgers standard policy doesnot allow master keying lever tumblerlocks. This is done for the protection ofthe end user.

    Lever tumbler locks have a limitednumber of usable keying combinations.Master keying reduces the number ofcombinations to three or four, whichdrastically limits the change keyapplications within a facility.

    Master keying lever tumbler locksrequires the bypass of four of the fivetumblers leaving only one tumbler toresist picking attempts. This wouldmake the remaining usablecombinations easy to pick.

    A master keyed lock is more easilypicked by an inmate/resident.

    Keying Security__________Proper use and care of keys helps tomaintain overall security.

    Keys should be handled only by staffpersonnel.

    Keys should be stored in a lockedcabinet, in the charge of an executiveofficer.

    Staff personnel should conceal thebitted end of the key from view ofinmates. Key shields available.

    Keys should never be left in a cylinderor out of reach of the officer.

    Doors should be closed and locked afteruse and locks/keepers checkedfrequently for tampering or vandalism.Doors left open for extended periods

    should be subject to lock and boltkeeper inspection to eliminateobstructions which may interfere withproper operation.

    Templates________________Templates are issued on a job specificbasis only. Southern Folger does notissue registered template books.Templates will be issued upon receipt ofa valid purchase order and hardwareschedule.

    Southern Folger reserves the right tomodify template information at any timeand without prior notice. When achange in templates occurs, material willbe shipped in accordance with thetemplates used for each specific job.

    Dimensional drawings in this catalog arenot to be used for template information.

    Electrical Indication______In systems using custom graphic panelsor electronic monitoring consoles,electrical indication is achieved byadding internal switches to the locks.These switches monitor the condition ofthe lock, indicating its locked orunlocked status. Details on specifyingthese switches are contained on eachproduct page.

    IMPORTANT NOTE: When a door is open,the deadlock actuator of the lock may bemanually depressed, giving a falseindication that the door is closed andlocked. To eliminate this false indication, adoor position switch should be installedand wired in series with the indicationswitches of the lock. Then a secureindication may be produced only afterthree conditions have been met:

    1) Deadlock actuator is depressed.

    2) Latchbolt is extended.

    3) The door is closed.

    FOLGER ADAM ELECTRIC LOCKS

    INTRODUCTION

  • A2 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Deadlatch Lever tumbler Swinging 51E Maximum A5-6

    51M Maximum A7-8

    Deadlatch Sliding 50HBM Maximum A9-10

    How to Specify A1150HBM SeriesLocks

    Deadlatch Pin tumbler Swinging 120E Med/Max A13-14(Mogul Cyl.) 120M Med/Max A15-16

    120MC Med/Max A17-18

    Deadlock Swinging 120ED Med/Max A19-20

    Deadlatch Roll-up 120RUP Med/Max A21-22

    How to Specify A23-24120 Series Locks

    Deadlatch Pin tumbler Swinging NS400E Min/Med A25-26(Builders NS400M/400MC Min/Med A27-28Hardware Cyl.)

    Deadlock Swinging NS400MCD Min/Med A29-30

    How to Specify A31-32NS400 Series Locks

    Fence Gate Locks Lever tumbler Swinging/Sliding 800 Maximum A33-34

    Mortise Pin Tumbler Swinging D9300 Min/Med A35-40Deadlatch (Mogul Cyl.)

    FOLGER ADAM ELECTRIC LOCKS

    ELECTRIC LOCK SELECTIONGUIDE AND SECTION INDEX

    LOCKTYPE

    CYLINDERTYPE

    DOORTYPE

    APPLICABLESERIES

    SECURITYLEVEL PAGE

    The above is a generalized guideline only. To determine specific models required for your application, refer to product pages fordetailed descriptions.

  • FA Rev. 02-10 A3

    For more information, please call 210.533.1231.

    FOLGER ADAM ELECTRIC LOCKS

    ELECTRIC LOCKAPPLICATION GUIDELINES

    IMPORTANT NOTE: The above guidelines are not specific recommendations. The security of a particular door or group of doorsdepends upon not only hardware employed, but also supervision both direct and indirect. For questions on the application of aparticular lock, contact the factory.

  • BLANK PAGE

  • FA Rev. 02-10 A5

    For more information, please call 210.533.1231.

    Description______________Series 51E Deadlatches are levertumbler, solenoid-operated locks forswinging doors. Specify keying asfollows:

    52E Five tumbler model, keyed cover side

    52E-6 Six tumbler model, keyed cover side

    56E Five tumbler model, keyed both sides

    56E-6 Six tumbler model, keyed both sides

    Applications_____________51E Deadlatches are designed for doorjamb installation and provide maximumsecurity for heavily used cell, corridor orentrance doors. They provide theconvenience of slam-locking withremote, electrical unlocking.

    Operations______________Standard (1): When connected to amomentary-contact switch, the latchboltretracts when the solenoid is energized.Once retracted, the latchbolt is heldmechanically retracted until the door isopened. The latchbolt extends when thedoor is open.

    Standard (1a): When connected to amaintained-contact switch, the latchboltretracts when the solenoid is energized.Once retracted, it is held electricallyretracted for an extended period oftime. The latchbolt extends only whenthe solenoid is de-energized.

    No-notch (2): Latchbolt extends whenthe switch is selected to lock.

    Standards Compliance____All 51E Series models are UL Listed asBurglary-Resistant Mechanisms and FireDoor Accessories to a three-hour rating.

    ASTM F-1577 Grade 1 Impact

    Standard Features_______ Solenoid voltage 120VAC

    Two piece plug connector Simplifies wiring.

    Instant solenoid operation Dependable, continuous-dutysolenoid.

    Automatic deadlocking When thelatchbolt is extended, it automaticallydeadlocks on closure.

    Full 3/4" bolt throw Projects 1/4"when retracted.

    Mechanical unlocking by key Foruse during power failure, or any timethe lock unlocks by use of prisonparacentric key. Latchbolt remainsretracted until relocked by key.

    FOLGER ADAM ELECTRIC LOCKSKey: Prison ParacentricDoor: Swinging

    SecurityLevel: Maximum 51E DEADLATCH

  • A6 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Indication switch A lock statusindication switch which monitors theextension of the latch bolt and thedeadlocked condition is included.

    Rugged construction Case andcover are 7 gauge steel.

    Tumbler Options Choice of five orsix tumbler models. Six tumblermodel offers greater pick resistance.

    Solid steel latchbolt Latchbolt iszinc plated steel; concealed pins resistsawing.

    Deadlock actuator Roller type, zincplated steel, adjustable for variationsin door-to-jamb clearance.

    Finish Zinc plated.

    Optional Features________ Solenoid voltage 220VAC

    No-notch feature The holdbacklever has no notch to hold thelatchbolt mechanically retracted. Thelatchbolt extends in the lockedposition regardless of the position ofthe door.

    Interlocking Accomplished throughthe control console.

    Specifications_________ Case and cover 7 gauge steel.

    Latchbolt Solid steel with hardened steel roller pins.

    Deadlock actuator Zinc platedsteel, roller type.

    Lever tumblers spring temperbrass, activated by heavy phosphor bronze springs.

    Key cylinder One piece,bronze alloy with paracentrickeyway.

    Bolt size 2" x 3/4"

    Bolt throw 3/4"

    ElectricalCharacteristics________ Solenoid Continuous-duty type.

    Ratings 120VAC, 60HZ, 13amps inrush, .75 amps seated220VAC, 60Hz, 6.5 amps inrush,.38 amps seated.

    Indication switch SPDT, UL Listed.

    Rating 15 amps at 125 or 250 VAC.

    How to Specify___________

    NOTE: The above are standard 5-tumbler models. To specify 6-tumblerunits, add 6 after the basic modelnumber. Example: 56E-6-L.

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    FOLGER ADAM ELECTRIC LOCKS Key: Prison ParacentricDoor: Swinging

    SecurityLevel: Maximum51E DEADLATCH

    OPERATION KEYING WITH IND.SWITCH

    Standard (1)one side 52EL

    two sides 56EL

    No-notch (2)one side 52ELNN

    two sides 56ELNN

    LEGEND

    56 LOCKKEYEDBOTHSIDES

    52 LOCKKEYEDHINGESIDE

    POCKET COVER HINGE SIDE

    25 LHRB LATCHBOLT RHRB 26

    27 LHRB LATCHBOLT RHRB 28

    Specify circled swing number when ordering.

  • FA Rev. 02-10 A7

    For more information, please call 210.533.1231.

    Description______________Series 51M Deadlatches are levertumbler, motor operated locks forswinging doors. Specify keying asfollows:

    52M Five tumbler model, keyed cover side

    52M-6 Six tumbler model, keyed cover side

    56M Five tumbler model, keyed both sides

    56M-6 Six tumbler model, keyed both sides

    Applications_____________These jamb-mounted locks providemaximum security for cell, corridor orentryway doors. They slam lock onclosure and provide staff with the safetyand convenience of remote, electricunlocking. Quiet motor operation is wellsuited to residence areas.

    Operations______________When used in conjunction with amomentary contact switch, the unitunlocks when energized. The latchboltretracts, and once retracted, it is heldmechanically retracted until the door isopened. The latchbolt extends when thedoor is open.

    Standards Compliance___51M Series Deadlatches are UL Listed asBurglary-Resistant Mechanisms and asFire Door Accessories to a three-hourrating. UL Fire Door rating is notavailable with Model 51MC.

    ASTM F 1577 Grade 1 - Impact

    Standard Features_______ Motor voltage 120VAC Two piece plug connector

    Simplifies wiring. Quiet operation Unlocks by

    smooth motor action. Automatic deadlocking All models

    automatically deadlock on closure. Rugged construction 7 gauge steel

    for durability. Indication switch A lock status

    indication switch which monitors theextension of the latch bolt and thedead locked condition is included.

    High security Five or six tumblermodels available. Six tumbler modeloffers greater pick resistance.

    Mechanical unlocking by key Inthe event of power failure, or at anytime, 51M Series deadlatches may beunlocked by prison paracentric key;latchbolt remains retracted untilrelocked by key.

    Solid steel latchbolt Zinc plated,with two hardened steel pins to resistsawing.

    Deadlock actuator Roller type, zincplated steel, adjustable for variationsin door-to-jamb clearance.

    Full 3/4" bolt throw Projects 1/4"when retracted.

    Finish Zinc plated.

    FOLGER ADAM ELECTRIC LOCKSKey: Prison ParacentricDoor: Swinging

    SecurityLevel: Maximum 51M DEADLATCH

  • A8 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Optional Features________ Motor voltage 24VDC Continuous-duty function Using a

    two-position, maintained contactswitch, and a two-position cam on themotor, the latchbolt may be heldretracted for extended periods. Thelatchbolt extends only when the dooris open and the motor is energized asecond time. The latchbolt deadlockswhen extended and the door isclosed.

    No-notch feature The holdbacklever has no notch to hold thelatchbolt mechanically retracted. Thisfeature may be used with ContinuousDuty feature, and operates in thesame manner as above, except thatthe latchbolt extends when the motoris energized a second time regardlessof the position of the door.

    Interlocking Accomplished throughthe control console.

    Specifications_________ Case and cover 7 gauge steel.

    Latchbolt Solid steel with hardened steel roller pins.

    Deadlock actuator Zinc platedsteel, roller-type.

    Lever tumblers Spring-temperbrass, activated by heavy phosphor-bronze springs.

    Key cylinder One piece, bronzealloy with paracentric keyway.

    Bolt size 2" x 3/4"

    Bolt throw 3/4"

    ElectricalCharacteristics________ Motor (AC) Synchronous-type

    with brake.

    Ratings (120VAC) 60HZ, 1.3 amps full load.

    Ratings (220VAC) 60HZ, .65 amps full load.

    Motor (DC) Permanent magnetgearmotor.

    Ratings 24VDC, 2.2 amps at full load.

    Indication switch SPDT, ULListed, 15 amps at 125VAC or 250VAC.

    How to Specify___________

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    FOLGER ADAM ELECTRIC LOCKS Key: Prison ParacentricDoor: Swinging

    SecurityLevel: Maximum51M DEADLATCH

    OPERATION KEYING W/INDICATIONSWITCHESW/INDICATION

    & INT. SWITCHES

    Standardone side 52ML 52MLI

    two sides 56ML 56MLI

    ContinuousDuty

    one side 52MCL N/A

    two sides 56MCL N/A

    WithNo-notch

    one side 52MCLNN N/A

    two sides 56MCLNN N/A

    LEGEND

    56 LOCKKEYEDBOTHSIDES

    52 LOCKKEYEDHINGESIDE

    POCKET COVER HINGE SIDE

    25 LHRB LATCHBOLT RHRB 26

    27 LHRB LATCHBOLT RHRB 28

    Specify circled swing number when ordering.

    NOTE: The above are standard 5-tumbler models. To specify6-tumbler units, add -6 after the basic model number.Example: 52M-6-L

    AdministratorTypewritten Text

    AdministratorTypewritten Text

    AdministratorTypewritten Text

    AdministratorCross-Out

    AdministratorCross-Out

    AdministratorTypewritten TextRev 11-12

    AdministratorTypewritten Text

    AdministratorTypewritten Text

    AdministratorCross-Out

  • FA Rev. 02-10 A9

    For more information, please call 210.533.1231.

    Description______________Series 50HBM Deadlatches are levertumbler, motor-operated locks forsliding doors, utilizing hookbolts. Specifykeying as follows:

    51 Keyed case side52 Keyed cover side56 Keyed both sides

    Applications_____________Jamb-mounted 50HBM locks should bespecified for maximum security cell,corridor, sallyport, or entrance/egresssliding doors. May be installed within alock pocket or full height column. Theyare designed to be part of an electricallocking/unlocking system to provideinstitutional staff with maximum safetyand flexibility of operation.

    Operations______________All 50HBM locks are operated by electricmotor. The choice of two motoroperations provides a variety offunctions:

    Full-Rotation Motor (50HBM) with latchback (1): Unlocks when the motor is energized bya momentary contact switch. Onceunlocked, the hookbolt is heldmechanically in the raised position untilthe door is opened. It then returns tonormal, lowered position.

    Two-Position Motor (50HBMC) without latchback (2): Same as above, except that thehookbolt is raised and lowered as themotor runs. A door starter should beinstalled in the track housing to pushthe door open when the motor reachesthe unlocking point.

    Testing__________________50HBM locks have been tested for over1,000,000 operations.

    Standard Features_______ Motor voltage 120VAC External mounting Locks install

    without cover plate removal. Externalslotted mounting holes simplifyinstallation and allow for variations indoor gap by permitting lateralmovement.

    Two-piece plug connector Simplifies wiring at time of installationand allows pre-wiring at the lockpocket.

    Superior durability Working partsare stainless steel and designed formaximum strength and corrosionresistance.

    Hardened hookbolt and deadlockactuator Zinc plated for corrosionresistance.

    Motor operation A choice of twooperations is available, as shown onfollowing page.

    High security Choice of five or sixlever tumbler models. Six tumblermodel offers greater pick resistance.

    Mechanical unlocking by key Once unlocked by key, the hookboltremains in that position until relockedby key (Models without latchbackfeature). Key is removable in theunlocked position.

    Indication switch The indicationswitch monitors the deadlock lever toindicate a deadlocked hookbolt.

    Finish Zinc plated.

    FOLGER ADAM ELECTRIC LOCKSKey: Prison ParacentricDoor: Sliding

    SecurityLevel: Maximum 50HBM DEADLATCH

  • A10 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Optional Features________Motor voltage 24VDC

    Lock bolt keepers Select 50H-4DBwith dust box.

    Dimensional Data________Note: Dimensions are for informationand planning purposes only and shouldnot be used as templates.

    Specifications_________ Case 7 and 10 gauge steel.

    Cover 10 gauge HRS.

    Hookbolt .5 inch steel, casehardened and zinc plated.

    Deadlock actuator .5 inchsquare CRS, hardened and zinc plated.

    Deadlock and operator levers Stainless steel.

    Springs Stainless steel.

    Motor Synchronous-typegearmotor with brake.

    ElectricalCharacteristics________ Motor (AC) Synchronous-type

    gearmotor with brake.Ratings: 120VAC, 60HZ, 1.3 ampsat full load.

    Motor (DC) Permanent magnet gearmotor.Ratings: 24VDC, 2.2 amps at fullload.

    Indication switch SPDT, UL Listed. Deadlock Ratings: 15 amps at 125or 250 VAC.Auxiliary Ratings: 10 amps 125 or 250 VAC.

    FOLGER ADAM ELECTRIC LOCKS Key: Prison ParacentricDoor: Sliding

    SecurityLevel: Maximum50HBM DEADLATCH

    MODEL NO.OPERATION

    DESCRIPTION

    LATCHBACK OPERATIONSWITCHESINTERLOCK

    INDICATIONSWITCH

    DEADLOCKWITH WITHOUT

    50HBM-1-01 1 X X

    50HBMC-1-04 2 X X

    LEGEND

    50HB Series LocksLOCK COVER PLATE TRACK SIDE

    56HBKEYEDBOTHSIDES

    52HBKEYEDTRACKSIDE

    31 HRHL 23

    33 HRHL 34

    Specify circled swing number when ordering.

    This chart shows applicability of functions and features to specific 50HBM models.For complete details, see How To Specify on the following page.

  • 1 2

    3

    4 6

    5

    7KeyingLocation51HB

    Case Side

    52HBCover Side

    56HBBoth Sides

    BasicModels

    MFull-Rotation

    Motor

    MCTwo-Position

    OperationSeries

    1Standard

    SwitchFunctions

    WithLatchback

    01DeadlockIndication

    WithoutLatchback

    04DeadlockIndication

    Handing*

    LHLeft Hand

    RHRight Hand

    LeverTumblers

    5Five

    6Six

    OperatingVoltages

    120 VAC

    24 VDC

    1 2 3 4 5 6 7

    56HB M - 1 01 x 5 x LH x 120 VAC

    FA Rev. 02-10 A11

    For more information, please call 210.533.1231.

    FOLGER ADAM ELECTRIC LOCKS

    HOW TO SPECIFY50HBM SERIES LOCKS

    *For information on handing, see chart on previous page.

  • BLANK PAGE

  • FA Rev. 02-10 A13

    For more information, please call 210.533.1231.

    Description______________Series 120E Deadlatches are pintumbler, solenoid-operated locks forswinging doors. Specify keying asfollows:

    121 Keyed case side122 Keyed cover side126 Keyed both sides

    Applications_____________Series 120E Deadlatches are suited formedium or maximum securityapplication including cell doors, sallyportor egress doors, corridor or entrancedoors. Sensitive administration areas ofan institution may also warrant 120Series locks. These jamb-mounted locksare designed to be part of an electricalsystem with remote operation andmonitoring to provide supervisorypersonnel with optimum protection andflexibility.

    Operation_______________Standard (1): Series 120E locks unlockwhen the solenoid is energized by amomentary-contact switch. Onceunlocked, the latchbolt is heldmechanically retracted until the door isopened. It then extends automatically.

    Without latchback (1a) 04 one switch;05 two switches: Once unlocked, thelatchbolt is held retracted as long as thesolenoid is energized. A maintainedcontact switch may be used to keep thelatchbolt retracted for an extendedperiod of time.

    Knob release(2): 120E Deadlatchesmay be specified with knob release onone side, where the knob is alwaysactive. Knob may be mounted on thecase side, or the cover side.

    Key holdback (3): When unlocked bykey, the deadlatch remains retracteduntil relocked by turning the key in theopposite direction. Available one sideonly. For locks keyed both sides,available cover side only.

    Note: Key cylinders for locks with key holdbackfeature must be installed at the factory. Thisfunction is not UL Listed for Fire Doors.

    Testing__________________120E Series Deadlatches and Maxi-Mogul Key Cylinders have been testedto 1,000,000 operations.

    Standards Compliance___Series 120E locks are UL Listed asBurglary-Resistant Mechanisms and FireDoor Accessories to a three-hour rating.Maxi-Mogul Key Cylinders meet UL437requirements.

    ASTM F1577 Grade 1 - Impact

    Standard Features_______ Solenoid voltage 120 VAC Superior durability Working parts

    of stainless steel afford greaterstrength and corrosion-resistance.

    Standard lock size All models usethe same size case, cover andmounting holes for simplifiedinstallation and frame preparation.

    External two-piece plug connector All models install without coverremoval. Simple plug-in connection tofield wiring.

    External mounting holes Easyinstallation eliminates the need forcover removal.

    Standard lock Mounts behindframe and does not require afaceplate.

    1" throw latchbolt Offers greatersecurity. Each bolt is hardened toresist sawing. When latchbolt isengaged in strike, bevel is concealedto prevent picking.

    Mechanical unlocking by key Specify Folger Adam Mogul cylinders,Maxi-Mogul high security cylinders orother mogul cylinders.

    Investment-cast stainless steelstrike Furnished with four tamper-resistant screws.

    Continuous-duty solenoid Forinstant action.

    Finish Zinc plated case and cover.

    FOLGER ADAM ELECTRIC LOCKSKey: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum 120E DEADLATCH

  • A14 Printed in USA FA Rev. 07-12

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Optional Features________ Optional solenoid voltage

    230 VAC, 60Hz. Faceplate US32D finish. Indication/auxiliary switches

    An indication switch monitors thedeadlock lever indicating adeadlocked latchbolt. The auxiliaryswitch monitors the roller bolt forextended or retracted position.

    Local electric key (LEK) A uniquefunction which uses two types of keysfor applications where inmates carrytheir own keys, but supervision isnecessary. One key turns in onedirection only and operates the lockelectrically. The supervisory key turnsin both directions to operate the lockelectrically and mechanically. Theelectric operation may be cancelledfrom a central console or controlpoint at any time via a three-positionswitch. The Maxi-Mogul Key Cylinder isuniquely suited for this highfrequency operation, shown by cycletest of 1,000,000 operations.LEK not available on any 120E-3Series Locks.

    Key Cylinder Extension When thelock is keyed on the stop side of thejamb, an extension eliminates theneed for a special, recessed framepocket. Specify E-3 for 3", E-4 for 4"or E-5 for 5".

    The chart at right shows applicability of above options to all 120E Models.

    For complete details, see How toSpecify in this section.

    Specifications_________ Case and cover 10 gauge steel.

    Latchbolt Investment-caststainless steel hardened, 1" throw.

    Deadlock lever Stainless steel, adjustable for door gap variations.

    Bolt opening Does not allowaccess to mechanism.

    Roller bolt Investment-caststainless steel with stainless steel roller.

    Operating lever Stainless steelto operate with solenoid.

    Strike Investment-cast stainlesssteel, attached with screws in twodirections.

    Solenoid 120 VAC continuousduty with stainless steel guides;230VAC optional.

    Springs Stainless steel.

    ElectricalCharacteristics________ Solenoid voltages (120 VAC)

    13 amps inrush - .75 amps seated.

    Solenoid voltages (230 VAC) 6.6 amps inrush - .38 amps seated.

    Switches SPDT, UL Listed, 15 amps @ 125 or 250 VAC.

    FOLGER ADAM ELECTRIC LOCKS Key: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum120E DEADLATCH

    MODEL NO. OPERATIONLATCHBACK OPERATIONALSWITCHES

    INDICATIONSWITCHES LEK

    AVAILABLEWITH W/O HOLDBACK RELOCK INT. DEADLATCH AUX

    120E-1-01 Standard (1) X X Yes120E-1-04 Standard (1a) X X Yes120E-1-07 Standard (1b) X X X Yes120E-2-01 Knob Release (2) X X Yes120E-2-04 Knob Release (2a) X X Yes120E-2-07 Knob Release (2b) X X X Yes120E-3-01 Key Holdback (3) X X No120E-3-04 Key Holdback (3a) X X No120E-3-07 Key Holdback (3b) X X X No

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

  • FA Rev. 02-10 A15

    For more information, please call 210.533.1231.

    Description______________Series 120M Deadlatches are pintumbler, motor-operated electro-mechanical locks for swinging doors.

    Specify keying as follows:

    121 Keyed case side122 Keyed cover side126 Keyed both sides

    Applications_____________Series 120M Deadlatches are jamb-mounted and designed for use inmedium or maximum securityapplications to secure cell doors,sallyports, corridors or entrance doors.The motor provides smooth, quietoperation and positive locking. 120Mlocks are designed to be part of anelectrical system with remote operationand monitoring. They afford flexibilityand safety to institution staff.

    Operations______________Standard (1): Series 120M locks unlockwhen the motor is energized by amomentary-contact switch. Onceunlocked, the latchbolt is heldmechanically retracted until the door isopened. It then extends automatically.

    Knob release(2): 120M Deadlatchesmay be specified with knob release onone side, where the knob is alwaysactive. Knob may be mounted on thecase side, or the cover side.

    Key holdback (3): When unlocked bykey, the deadlatch remains retracteduntil relocked by turning the key in theopposite direction. Available one sideonly. This function is not UL Listed forFire Door Accessories to a three-hourrating.

    Note: Key cylinders for locks with key holdbackfeature must be installed at the factory.

    Testing__________________120M Series Deadlatches and Maxi-Mogul Key Cylinders have been testedto 1,000,000 operations.

    Standards Compliance___All Series 120M locks are UL Listed asBurglary-Resistant Mechanisms and FireDoor Accessories to a three-hour rating,except Key holdback function, which isnot Fire rated.

    Maxi-Mogul Key Cylinders meet UL437requirements.

    ASTM F1577 Grade 1 - Impact

    Standard Features_______ Motor voltage 120 VAC Superior durability Working parts

    of stainless steel afford greaterstrength and corrosion resistance.

    Standard lock size All models usethe same size case, cover and

    mounting holes for simplifiedinstallation and frame preparation.

    External two-piece plug connector All models install without coverremoval. Simple plug-in connection tofield wiring.

    External mounting holes Easyinstallation eliminates the need forcover removal.

    Standard lock Mounts behindframe and does not require afaceplate.

    1" throw latchbolt Offers greatersecurity. Each bolt is hardened toresist sawing. When latchbolt isengaged in strike, bevel is concealedto prevent picking.

    Mechanical unlocking by key Specify Folger Adam Mogul cylinders,Maxi-Mogul high security cylinders orother Mogul cylinders.

    FOLGER ADAM ELECTRIC LOCKSKey: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum 120M DEADLATCH

  • A16 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Investment-cast stainlesssteel strike Furnished with fourtamper-resistant screws.

    Fractional HP Motor Permanentlylubricated for smooth quiet operationwith thermal overload protection anda brake for accurate locking position.

    Finish Zinc plated case and cover.

    Optional Features________ Faceplate US32D finish. Indication/auxiliary switches

    An indication switch monitors thedeadlock lever indicating adeadlocked latchbolt. The auxiliaryswitch monitors the latchbolt forextended or retracted position.

    Local electric key (LEK) A uniquefunction which uses two types of keysfor applications where inmates carrytheir own keys, but supervision isnecessary. One key turns in onedirection only and operates the lockelectrically. The supervisory key turnsin both directions to operate the lockelectrically and mechanically. Theelectric operation may be cancelledfrom a central console or control pointat any time via a three-position switch.The Maxi-Mogul Key Cylinder isuniquely suited for this highfrequency operation, shown by cycletest of 1,000,000 operations.LEK not available on any 120M-3Series Locks.

    Key Cylinder Extension When thelock is keyed on the stop side of thejamb, an extension eliminates theneed for a special, recessed framepocket. Specify E-3 for 3", E-4 for 4"or E-5 for 5".

    Optional motor voltage 24 VAC or24 VDC.

    Specifications_________ Case and cover 10 gauge steel.

    Latchbolt Investment-cast stainless steel, hardened. 1"throw.

    Deadlock lever Stainless steel, adjustable for door gapvariations.

    Bolt opening Does not allowaccess to mechanism.

    Roller bolt Investment-caststainless steel with stainless steelroller.

    Operating lever Stainless steelto operate with solenoid.

    Strike Investment-cast stainlesssteel, attached with screws in twodirections.

    Motor 120 VAC continuousduty, 24 VAC or 24 VDC optional,synchronous-type gearmotor.

    Springs Stainless steel.

    ElectricalCharacteristics________ AC motors Synchronous-type

    gearmotor with brake.

    Ratings: 120 VAC: 60 Hz, 1.3amps at full load.

    DC motors Permanent-magnetgearmotor.

    Ratings: 24 VDC, 2.2 amps at fullload.

    Switch SPDT, UL Listed, 15 amps @ 125 or 250 VAC.

    FOLGER ADAM ELECTRIC LOCKS Key: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum120M DEADLATCH

    MODEL NO.OPERATION

    DESCRIPTIONLATCHBACK

    INDICATION SWITCHES LEKAVAILABLE

    DEADLATCH

    120M-1-01 Standard (1) X X Yes

    120M-2-01 Knob Release (2) X X Yes

    120M-3-01 Key Holdback (3) X X No

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    The chart below shows applicability ofabove options to all 120M Models.

    For complete details, see How toSpecify in this section.

  • FA Rev. 02-10 A17

    For more information, please call 210.533.1231.

    FOLGER ADAM ELECTRIC LOCKSKey: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum

    Description______________Series 120MC Deadlatches are pintumbler, motor-operated locks utilizing atwo-position motor cam.

    Specify keying as follows:

    121 Keyed case side122 Keyed cover side126 Keyed both sides

    Applications_____________Series 120MC Deadlatches are suitable foruse in medium or maximum securitysituations to lock cell, corridor or entrancedoors. Especially appropriate for areasrequiring the latchbolt to remain retracteduntil it is selected to lock again.

    Like all Series 120 locks, the jamb-mounted 120MC Deadlatch is designedfor use as part of an electrical system withremote operation and monitoring.

    Operations______________Standard (1): Unlocks when the motor isenergized by either a two or threeposition, maintained contact switch, or athree position momentary contact switch.Once unlocked, the latchbolt remainsretracted until it is selected to lock.Opening and closing the door has noeffect on the lock when selected tounlock. The latchbolt extends only whenthe door is opened and the motor isselected to lock. If the door is closed, itmust be opened to extend the latchbolt.Two additional variations on this featureare offered:

    Without latchback (1a): Once unlocked,the latchbolt is held retracted only as longas the motor remains in the unlockedposition. A maintained-contact switch maybe used to keep the latchbolt retracted foran extended period of time.

    Relock (1b) 09: Once unlocked, thelatchbolt is held retracted until the door isopened. It then extends automatically.This operation requires an additionalcontrol wire, and may be cancelled byadding an additional control switch. Amomentary-contact switch is used forunlocking, and the auxiliary switch is usedfor relocking. When the door is opened,the auxiliary switch repositions the motorto a locked position so that the lock willdeadlatch on closure.

    Knob release(2): 120MC Deadlatchesmay be specified with knob release onone side, where the knob is always active.Knob may be mounted on the case side,or the cover side.

    Key holdback (3): When unlocked by key,the deadlatch remains retracted untilrelocked by turning the key in the oppositedirection. Available one side only.

    Note: Key cylinders for locks with key holdbackfeature must be installed at the factory.

    Testing__________________120MC Series Deadlatches and Maxi-Mogul Key Cylinders have been tested to1,000,000 operations.

    Standards Compliance___All Series 120MC locks are UL Listed asBurglary-Resistant Mechanisms.

    Maxi-Mogul Key Cylinders meet UL437requirements.

    Standard Features_______ Motor voltage 120 VAC Superior durability Working parts of

    stainless steel afford greater strengthand corrosion resistance.

    Standard lock size All models usethe same size case, cover and mountingholes for simplified installation andframe preparation.

    External two-piece plug connector All models install without coverremoval. Simple plug-in connection tofield wiring.

    External mounting holes Easyinstallation, and eliminate the need forcover removal.

    Standard lock Mounts behind frameand does not require a faceplate.

    1" throw latchbolt Offers greatersecurity. Each bolt is hardened to resistsawing. When latchbolt is engaged instrike, bevel is concealed to preventpicking.

    Mechanical unlocking by key SpecifyFolger Adam Mogul cylinders, Maxi-Mogul high security cylinders or otherMogul cylinders.

    Investment-cast stainless steel strike Furnished with four tamper-resistantscrews.

    Fractional HP Motor Permanentlylubricated for smooth quiet operationwith thermal overload protection and abrake for accurate locking position.

    Finish Zinc plated case and cover.

    120MC HALF-CYCLEDEADLATCH

  • A18 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    FOLGER ADAM ELECTRIC LOCKS Key: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum120MC HALF-CYCLE

    DEADLATCHOptional Features________ Faceplate US32D finish. Indication/auxiliary switches An

    indication switch monitors the deadlocklever indicating a deadlocked latchbolt.The auxiliary switch monitors thelatchbolt for extended or retractedposition.

    Local electric key (LEK) A uniquefunction which uses two types of keysfor applications where inmates carrytheir own keys, but supervision isnecessary. One key turns in onedirection only and operates the lockelectrically. The supervisory key turns inboth directions to operate the lockelectrically or mechanically. The electricoperation may be cancelled from acentral console or control point at anytime via a three-position switch.The Maxi-Mogul key cylinder isuniquely suited for this high frequencyoperation, shown by cycle test of1,000,000 operations.

    LEK not available on any 120MC-3Series Locks.

    Key Cylinder Extension When thelock is keyed on the stop side of thejamb, an extension eliminates the needfor a special, recessed frame pocket.

    Optional motor voltage 24 VAC or24 VDC.

    Dimensional Data________Note: Dimensions are for information andplanning purposes only, and should notbe used as templates.

    The chart at right shows applicability ofabove options to all 120MC Models.

    For complete details, see How toSpecify in this section.

    Specifications_________ Case and cover 10 gauge steel.

    Latchbolt Investment-caststainless steel, hardened, 1" throw.

    Deadlock lever Stainless steel,adjustable for door gap variations.

    Bolt opening Does not allowaccess to mechanism.

    Roller bolt Investment-caststainless steel with stainless steelroller.

    Operating lever Stainless steel tooperate with motor.

    Strike Investment-cast stainlesssteel, attached with screws in twodirections.

    Motor 120 VAC continuous duty,24 VAC or 24 VDC optional,synchronous-type gearmotor.

    Springs Stainless Steel.

    ElectricalCharacteristics________ AC motors Synchronous-type

    gearmotor with brake.

    Ratings:

    120 VAC: 60 Hz, 1.3 amps at fullload.

    DC motors Permanent-magnetgearmotor.

    Ratings: 24 VDC, 2.2 amps at fullload.

    Switches SPDT, UL Listed, 15amps @ 125 or 250 VAC.

    MODEL NO. OPERATIONLATCHBACK RELOCK

    SWITCHINDICATION SWITCHES LEK

    AVAILABLEWITH W/O DEADLATCH AUX

    120MC-1-01 Standard (1) X X Yes120MC-1-04 Standard (1a) X X Yes120MC-1-09 Standard (1b) X X X Yes120MC-2-01 Knob Release (2) X X Yes120MC-2-04 Knob Release (2) X X Yes120MC-2-09 Knob Release (2) X X X Yes120MC-3-01 Key Holdback (3) X X No120MC-3-04 Key Holdback (3) X X No120MC-3-09 Key Holdback (3) X X X No

  • FA Rev. 02-10 A19

    For more information, please call 210.533.1231.

    Description______________Series 120ED Deadbolts are pintumbler, solenoid-operated locks forswinging doors. Specify keying asfollows:

    121 Keyed case side122 Keyed cover side126 Keyed both sides

    Applications_____________Series 120ED Deadbolts are ideal for awide range of medium or maximumsecurity applications including celldoors, corridor doors, entryways or anyopening requiring a deadbolt-typelocking. These jamb-mounted locks aredesigned to be part of an electricalsystem with remote unlocking andmonitoring to provide staff safety andoperational flexibility.

    Operation_______________Key Holdback (3): Units unlock by keyor when the solenoid is energized by amomentary-contact switch oremergency-unlock signal (fire alarm).Once unlocked, the deadbolt is heldmechanically retracted, regardless ofdoor position, and must be relocked by key.

    Testing__________________120ED Series Deadbolts and Maxi-Mogul key cylinders have been testedto 1,000,000 operations.

    Standards Compliance___Series 120ED locks are UL Listed asBurglary-Resistant Mechanisms. Maxi-Mogul key cylinders meet UL437requirements.

    ASTM F-1577 Grade 1 Impact

    Standard Features_______ Solenoid voltage 120 VAC Superior durability Working parts

    of stainless steel afford greaterstrength and corrosion-resistance.

    Standard lock size All models usethe same size case, cover andmounting holes for simplifiedinstallation and frame preparation.

    External two-piece plug connector All models install without coverremoval. Simple plug-in connection tofield wiring.

    External mounting holes Easyinstallation eliminates the need forcase and cover removal.

    Standard lock Mounts behindframe and does not require afaceplate.

    1" throw deadbolt Offers greatersecurity. Each bolt is hardened toresist sawing.

    Mechanical unlocking by key Specify Folger Adam Mogul cylinders,Maxi-Mogul high security cylinders orother mogul cylinders.

    Continuous-duty solenoid Forinstant action; positive unlocking.

    Finish Zinc plated case and cover. Deadlock switch Monitors the

    deadlock lever indicating adeadlocked deadbolt.

    FOLGER ADAM ELECTRIC LOCKSKey: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum 120ED DEADBOLT

  • A20 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Optional Features________ Optional solenoid voltage

    230 VAC, 60Hz. Key Cylinder Extension When the

    lock is keyed on the stop side of thejamb, an extension eliminates theneed for a special, recessed framepocket. Specify E-3 for 3", E-4 for 4"or E-5 for 5".

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    For complete details, see How toSpecify in this section.

    Specifications_________ Case and cover 10 gauge steel.

    Deadbolt Investment-cast stainless steel, hardened, 1" throw.

    Deadlock lever Stainless steel, adjustable for door gap variations.

    Bolt opening Does not allowaccess to mechanism.

    Operating lever Stainless steelto operate with solenoid.

    Solenoid 120 VAC continuousduty with stainless steel guides,230VAC optional.

    Springs Stainless steel.

    ElectricalCharacteristics________ Solenoid voltage standard

    (120 VAC) 13 amps inrush - .75amps seated.

    Solenoid voltages optional(230 VAC) 6.6 amps inrush -.38 amps seated.

    Switches SPDT, UL Listed, 15amps @ 125 or 250 VAC.

    FOLGER ADAM ELECTRIC LOCKS Key: MogulDoor: Swinging

    SecurityLevel: Medium/Maximum120ED DEADBOLT

    MODEL NO.OPERATION

    DESCRIPTIONLATCHBACK

    INDICATIONSWITCH

    DEADLOCK

    120ED-3-01 Key Holdback (3) X X

    The chart below shows applicability ofabove options to all 120ED Models.

  • FA Rev. 02-10 A21

    For more information, please call 210.533.1231.

    Description______________Series 120RUP Deadlatches are pintumbler, solenoid-operated locks forroll-up doors. Specify keying as follows:

    121 Keyed case side122 Keyed cover side126 Keyed both sides

    Applications_____________Series 120RUP Deadlatches aredesigned to provide security for garageand service bay roll-up doors. In thecase of roll-up shutters or unusualclosures, the units may be keyed twosides, with key holdback one side only.120RUP Models are fully compatiblewith electrically operated and monitoredsystems and provide safe, remotelocking and unlocking.

    Operation_______________This device unlocks when the solenoidis energized by a momentary contactswitch. Once unlocked, the latchbolt isheld mechanically retracted and a switchenergizes the open circuit of the roll-up door. When the door is opened, thelatchbolt extends automatically. 120RUPlocks may be mechanically unlocked bykey, with latchbolt remaining retracteduntil relocked by key.

    Testing__________________120RUP Deadlatches and Maxi-Mogul

    key cylinders have been tested to1,000,000 operations.

    Standards Compliance___120RUP locks are UL Listed as Burglary-Resistant Mechanisms. Maxi-Mogul keycylinders meet UL437 requirements.

    Standard Features_______ Solenoid voltage 120 VAC.

    Superior durability Working partsof stainless steel afford greaterstrength and corrosion-resistance.

    Standard lock size All models usethe same size case, cover andmounting holes for simplifiedinstallation and frame preparation.

    External mounting holes Easyinstallation and eliminate the need forcase and cover removal.

    1" throw latchbolt Offers greatersecurity. Each bolt is hardened toresist sawing.

    Mechanical unlocking by key Specify Folger Adam Mogul cylindersor Maxi-Mogul high securitycylinders.

    Continuous-duty solenoid Provides instant unlocking action.

    Finish Zinc plated case and cover.

    Optional Features________ Optional solenoid voltage

    230 VAC, 60Hz.

    Indication/auxiliary switches An indication switch monitors thedeadlock lever indicating adeadlocked latchbolt.

    FOLGER ADAM ELECTRIC LOCKSKey: MogulDoor: Roll-up

    SecurityLevel: Medium/Maximum 120RUP DEADLATCH

  • A22 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Key cylinder extension When thelock is keyed on the stop side of thejamb, an extension eliminates theneed for a special, recessed framepocket. Specify E-3 for 3", E-4 for 4"or E-5 for 5" extensions.

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    For complete details, see How toSpecify in this section.

    Specifications_________ Case and cover 10 gauge steel.

    Latchbolt Investment-caststainless steel, hardened, 1" throw.

    Deadlock lever Stainless steel,adjustable for door gapvariations.

    Roller bolt Investment-caststainless steel with stainless steelroller.

    Operating lever Stainless steelto operate with solenoid.

    Solenoid 120 VAC continuousduty with stainless steel guides,230VAC optional.

    Springs Stainless steel.

    ElectricalCharacteristics________ Solenoid voltage standard

    (120 VAC) 13 amps inrush -.75 amps seated.

    Solenoid voltages optional (230 VAC) 6.6 amps inrush -.38 amps seated.

    Switches SPDT, UL Listed, 15 amps @ 125 or 250 VAC.

    FOLGER ADAM ELECTRIC LOCKS Key: MogulDoor: Roll-up

    SecurityLevel: Medium/Maximum120RUP DEADLATCH

  • 1 3

    2

    4 5

    8

    6

    FA Rev. 02-10 A23

    For more information, please call 210.533.1231.

    FOLGER ADAM ELECTRIC LOCKS

    HOW TO SPECIFY120 SERIES LOCKS

    KeyingLocation

    121Case Side

    122Cover Side

    126Both Sides

    Basic ModelsDeadlatches

    ESolenoid

    MFull-Rotation

    Motor

    MCTwo-Position

    Motor

    DeadboltsED

    Solenoid

    RUPSolenoid

    (Roll-Up Door)

    OperationSeries

    1Standard

    2Knob Release

    3Holdbackby Key

    (one side only)

    SwitchFunctions

    01DeadlockIndication

    Switch WithLatchback

    04DeadlockIndicationSwitch NoLatchback

    07Electric

    Holdback

    Key Cylinderand Finish

    Folger AdamMogul

    MPrep. Only

    M0-US26D110 Mogul

    Cylinder withUS26D Finish

    M1-US26D190-1 Maxi-Mogul KeyCylinder withUS26D Finish

    190-AASSA Mogul Key Cylinderwith US26D

    Finish

    190MMedeco MogulKey Cylinder

    with US4 Finish

    Available KeyCylinderFinishes:

    US26D(standard)

    US26D

    LEKFeature

    LEK-1Case Side

    LEK-2Cover Side

    LEK-6Both Sides

    9Key CylinderExtensionE33" Long

    E44" Long

    E55" Long

    LockHanding*

    Deadlatches

    LHRBLeft Hand

    Reverse Bevel

    RHRBRight Hand

    Reverse Bevel

    DeadboltsLH

    Left Hand

    RHRight Hand

    7OperatingVoltageSolenoid120 VAC230 VAC

    Motor120 VAC24 VDC

    1 2 3 4 5 6 7 8 9

    126 E - 1 - 01 x M0-US26D x LHRB x 120 VAC x LEK-2 x E3

    *For applicationhanding see thehanding chart onthe followingpage.

  • A24 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    FOLGER ADAM ELECTRIC LOCKS

    HOW TO SPECIFY120 SERIES LOCKS

    Specify circled swing number when ordering.

  • FA Rev. 02-10 A25

    For more information, please call 210.533.1231.

    Description______________NS400E Series Deadlatches are pintumbler, solenoid-operated locks forswinging doors. Specify buildershardware cylinders and keying asfollows:

    NS402E & NS402EFSKeyed one side

    NS406E & NS406EFSKeyed both sides

    Note: See optional features for factory or customer-supplied key cylinders. For modelsNS400E and NS400EFS, no cylinders are supplied.

    Applications_____________Specify for minimum/medium securityswinging cell, corridor or administrationareas of institutions with 2" wide hollowmetal jamb construction.

    Operations______________A remote switch is used to control thelock electrically, or it may be operatedmechanically by builders hardwarecylinder. These locks offer theconvenience of remote, electricunlocking or locking and automaticdeadlocking when the door is closed.

    Fail-Safe Models

    Unlock when solenoid is de-energized(1): by switch or power failure, and thelatch remains retracted while the door isopen. Upon closure, with powerrestored, the latchbolt extends anddeadlocks.

    Non-Fail-Safe Models

    Unlock when solenoid is energized(1): by a momentary-contact switch.Latchbolt remains retracted mechanically

    until the door is opened. Upon closure,the latchbolt extends automatically(mechanical latchback).

    Unlock when solenoid is energized(2): by a momentary-contact switch.Latchbolt is electrically held retractedonly as long as control switch is tripped(no mechanical latchback). The doormust be opened while control switch isin the unlocked position. Upon closure,the latchbolt deadlocks automatically.Continuous-duty feature is standard tohold bolt retracted for extended periods(no latchback, continuous-duty powermodulator).

    Unlock when solenoid is energized(3): by a momentary-contact switch.Latchbolt is held electrically retracteduntil door is opened, then it extendsautomatically (electric holdback).

    Standards Compliance____ All deadlatch models UL1034

    Burglary-resistant electric deadbolts. Non-fail-safe models, UL10B

    Electrically controlled single pointlocks or latches, three-hour rating, A label.

    ASTM F-1577 Grade 1 Impact

    Standard Features_______ Instant solenoid actuation Heavy

    duty solenoid provides fast, audiblelatchbolt operation.

    Fail-safe model operation Solenoidholds latchbolt extended anddeadlocked.

    Compact size Designed for hollowmetal frames with standard 2" face.

    Power modulator Allows solenoidmodels to operate on either 24VAC or24VDC - reduces power consumption.UL listed and patented (Pat. No.4,797,779).

    Two-piece, twelve-pin plug connector Simplifies wiring, allowspre-wiring of the lock opening.

    Heavy duty lock mechanism Designed with heavy duty, corrosion-resistant working parts tested over1,000,000 cycles.

    Stainless steel strike Angled lip-type, furnished with tamper-resistantscrews. Requires less force to closeand lock the door.

    Mechanical latchback (ModelNS400E-01) Holds latchboltretracted until door opens. Notavailable in fail-safe models.

    Mechanical unlocking by key Offers manual control at the door inevent of power failure or at any othertime.

    Stainless steel latchbolt 3/4" throw,hardened to resist sawing.

    FOLGER ADAM ELECTRIC LOCKSKey: Builders HardwareDoor: Swinging

    SecurityLevel: Minimum/Medium NS400E

    SOLENOID-OPERATED DEADLATCHES

  • A26 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Holdback switch (ModelsNS400EFS, NS400E with electricalholdback) Maintains electricalholdback. Requires a relay in thecentral control console.

    Finish US32D satin stainless steel. Indication switch An internal switch

    to monitor the positions of thedeadlock actuator. Signals deadlockedcondition.

    Optional Features_______ Builders hardware cylinders High

    security six-pin tumbler cylinder maybe specified. Special keying requestswill be accommodated, if possible.

    NOTE: Customer-supplied key cylinders may beused to adapt NS400 Series locks to a specifickeying system. These cylinders must have:a) 1-5/32" diameter, full bar stock bodies.b) 1-1/8" length, including cam.c) Standard, removable Yale-type cam.Cylinders and all keys should be sent to SouthernFolger Detention Equipment Company and arerequired with cylinder extenders.

    Local electric key (LEK) Inmate keyoperates lock electrically. Staff keysalways operate the lock manually andcan operate it electrically. Feature isenabled or canceled from a remotecontrol console.

    NOTE: When key cylinders for LEK are suppliedby customer, contact factory before ordering orsending cylinders.

    Inmate push button Allowsoperation of the lock from inside theroom or cell. May be canceled fromcentral control console. A double-pole,double-throw switch is available foradditional functions.

    Key cylinder extension Requiredwhen lock is keyed on the stop side ofthe door frame. Five standard lengthsare offered:Jamb CylinderSize Extension4-1/2" 5" 4-3/4"5" 6" 5-3/4"6" 7" 6-3/4"7" 8" 7-3/4"8" 9" 8-3/4"

    NOTE: Please specify appropriate cylinderextension length when ordering. Special lengthsmay be provided for other jamb thicknesses.Contact factory for pricing and availability.

    Finish Key Cylinder: US26D

    Specifications_________ Lock case Investment-cast

    stainless steel.

    Latchbolt Investment-caststainless steel hardened.

    Latchbolt throw 3/4"

    Operating lever Stainless steel.

    Deadbolt lever/trigger bolt Investment-cast stainless steel.

    Strike Stainless steel stamping,angled lip.

    ElectricalCharacteristics________ Solenoid Tubular, continuous-

    duty power modulator.

    Voltage 24 VAC or DC, 3.3amps, 82 watts inrush; .25 amps6 watts seated.

    Indication switch SPDT, UL listed.

    Switch rating 5 amp @ 125 or 250 VAC.

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    For complete details, see How toSpecify in this section.

    FOLGER ADAM ELECTRIC LOCKS Key: Builders HardwareDoor: Swinging

    SecurityLevel: Minimum/MediumNS400E

    SOLENOID-OPERATED DEADLATCHES

    MODEL OPERATIONINDICATION

    SWITCH

    LATCHBACK OPERATIONALSWITCH

    HOLDBACK

    LEKOPTION

    CONTINUOUSDUTY

    MODULATORWITH WITHOUT ELECTRIC

    NS400E-01 1 Available StandardNS400E-04 2 Available StandardNS400E-07 3 Available StandardNS400EFS-04 1 Available Standard

    Feature/Option Chart

  • FA Rev. 02-10 A27

    For more information, please call 210.533.1231.

    Description______________NS400M and NS400MC SeriesDeadlatches are pin tumbler, motor-operated locks for swinging doors.Specify builders hardware cylinders andkeying as follows:

    NS402M/MC Keyed one sideNS406M/MC Keyed both sides

    Note: See optional features for factory orcustomer-supplied key cylinders. For ModelsNS400M and NS400MC, no cylinders aresupplied.

    Applications_____________Specify for minimum/medium securityswinging cell, corridor or administrationareas of institutions, with 2" widehollow metal jamb construction.

    Operations______________A remote switch is used to control thelock electrically, or may be operatedmechanically by a builders hardware keycylinder. These locks offer theconvenience of remote, electricunlocking or locking and automaticdeadlocking when the door is closed.

    Motor-Actuated Models

    Unlock when the motor is energized(1): by a momentary-contact switch.Latchbolt is held mechanically retracteduntil the door is opened. It then extendsautomatically (mechanical latchback).

    Two-Position Motor Actuated Models

    Lock or unlock when the motor isenergized (1): by either a two or three-position maintained-contact switch, orby a three-position, momentary-contactswitch. When unlocked by controlswitch, latchbolt remains retracted

    by motor position until control switch isset to lock. Latchbolt is heldmechanically retracted until the door isopened. It will then extendautomatically, if the control switch is setto the lock position (mechanicallatchback).

    Lock or unlock when the motor isenergized (2): by either a two or three-position maintained-contact switch, or athree-position momentary-contactswitch. Latchbolt then remains retracteduntil selected to lock. Opening andclosing the door has no effect on thelock (no latchback).

    Unlock when the motor is energized(3): by a momentary contact switch. Arelock switch energizes the motor torelock once the door is open. Onclosure, the latchbolt deadlocksautomatically (no latchback with relock).

    Standards Compliance___ All deadlatch models, UL1034

    Burglary-Resistant Mechanisms. All models (except two-position

    motor actuated), UL10B Electricallycontrolled single point locks orlatches, three-hour rating, A label.

    ASTM F-1577 Grade 1 Impact

    Standard Features_______ 300 lb. rated side load motor

    operation (Models NS400M,NS400MC) Preclude jamming byapplying side pressure on the door.

    Compact size Designed for hollowmetal frames with standard 2" face.

    Two-piece, twelve-pin plugconnector Simplifies wiring, allowspre-wiring of the lock opening.

    Heavy-duty lock mechanism Designed to complement the hightorque motor. Corrosion resistantworking parts tested over 1,000,000cycles.

    Stainless steel strike Angled liptype, furnished with tamper resistantscrews. Requires less force to closeand lock the door.

    Mechanical latchback (ModelsNS400M, NS400MC) Holdslatchbolt retracted until door opens.

    Mechanical unlocking by key Offers manual control at the door inevent of power failure, or at any othertime.

    Stainless steel latchbolt 3/4" throw,hardened to resist sawing.

    Relock switch (Model NS400MC) Repositions motor to relock whendoor is opened.

    Finish Key Cylinder: US32D.

    FOLGER ADAM ELECTRIC LOCKSKey: Builders HardwareDoor: Swinging

    SecurityLevel: Minimum/Medium NS400M and 400MC

    MOTOR-OPERATED DEADLATCHES

  • Indication switch An internal switchto monitor the positions of thedeadlock actuator. Signals deadlockedcondition.

    Optional Features________ Builders hardware cylinders High

    security six-pin tumbler cylinder maybe specified. Special keying requestswill be accommodated, if possible.

    Note: Customer supplied key cylinders may beused to adapt NS400 Series locks to a specifickeying system. These cylinders must have:a. 1-5/32" diameter, full bar stock bodies.b. 1-1/8" length, including cam.c. Standard, removable Yale-type cam.

    Cylinders and all keys should be sent toSouthern Folger Detention EquipmentCompany and are required with cylinderextenders.

    Local electric key (LEK) Inmate keyoperates lock electrically. Staff keysalways operate the lock manually andcan operate it electrically. Feature isenabled or canceled from a remotecontrol console.

    Inmate push button Allowsoperation of the lock from inside theroom or cell. May be canceled fromcentral control console. A double pole, double throw switch is available foradditional functions.

    Key cylinder extension Requiredwhen lock is keyed on the stop side ofthe door frame. Five standard lengthsare offered:Jamb CylinderSize Extension4-1/2" 5" 4-3/4"5" 6" 5-3/4"6" 7" 6-3/4"7" 8" 7-3/4"8" 9" 8-3/4"

    NOTE: Please specify appropriate cylinderextension length when ordering. Special lengthsmay be provided for other jamb thicknesses.Contact factory for pricing and availability.

    Finish Key Cylinder: US26D.

    Specifications_________ Lock case Investment-cast

    stainless steel.

    Latchbolt Investment-cast stainless steel hardened.

    Latchbolt throw 3/4"

    Operating lever Stainless steel.

    Deadbolt lever/trigger bolt Investment-cast stainless steel.

    Strike Stainless steel stamping,angled lip.

    ElectricalCharacteristics________ Motor High-torque,

    permanently lubricated,permanent magnet, planetarygearmotor, UL Listed.

    Voltage 24 VDC, operates on24 VAC via rectifier 0.12 Ampsrunning, 1.29 amps stalled.

    Indication switch SPDT, ULlisted.

    Switch rating 5 amp @ 125 or250 VAC.

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    For complete details, see How toSpecify in this section.

    A28 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    FOLGER ADAM ELECTRIC LOCKS Key: Builders HardwareDoor: Swinging

    SecurityLevel: Minimum/MediumNS400M and 400MC

    MOTOR-OPERATED DEADLATCHES

    Feature/Option Chart

    MODEL OPERATIONINDICATION

    SWITCH

    LATCHBACK OPERATIONALSWITCH

    HOLDBACK

    LEKOPTION

    CONTINUOUSDUTY

    MODULATORWITH WITHOUT

    NS400M-01 1 Available NoNS400MC-01 1 No NoNS400MC-04 2 No NoNS400MC-09 3 Available No

  • FA Rev. 02-10 A29

    For more information, please call 210.533.1231.

    Description______________NS400MCD is a pin tumbler, two-position motor-operated deadbolt forswinging doors. Specify buildershardware cylinders and keying asfollows:

    NS402MCD Keyed one sideNS406MCD Keyed both sides

    Note: See optional features for either factory orcustomer-supplied key cylinders. ModelNS400MCD, no cylinder supplied.

    Applications____________Specify for minimum/medium securityswinging cell or office areas ofinstitutions requiring deadbolt locks foruse in 2" wide hollow metal jambconstruction.

    Operations______________Locks or unlocks when motor isenergized by either a two or three-position maintained contact switch.Once unlocked, the deadbolt remainsretracted until selected to lock. Openingand closing the door have no effect onthe lock. Non-fail-safe only. Holdbackswitch prevents the deadbolt fromextending while the door is open.Deadbolt is deadlocked upon closure ofthe door.

    Standards Compliance___ UL1034 Burglary-Resistant

    Mechanisms. ASTM F-1577 Grade 1 Impact

    Standard Features_______ 300 lb. rated side load motor

    operation Precludes jamming byapplying side pressure on the door.

    Heavy-duty lock mechanism Designed to complement the hightorque motor. Corrosion-resistantworking parts tested over 1,000,000cycles.

    Compact size Specifically for hollowmetal frames with standard 2" face.

    Two-piece, twelve-pin plugconnector Simplifies wiring, allowspre-wiring of the lock opening.

    Stainless steel strike Furnished withtamper-resistant screws.

    Holdback switch Does not allowdeadbolt to extend while door isopen.

    Mechanical unlocking by key Offers manual control at the door inevent of power failure, or at any othertime.

    Stainless steel deadbolt 3/4"throw, hardened to resist sawing.

    Faceplate finish US32D satinstainless steel.

    Indication switch An internal switchto monitor the positions of thedeadlock actuator. Signals deadlockedcondition.

    Optional Features________ Builders hardware key cylinders

    High security six-pin tumbler cylindermay be specified. Special keyingrequests will be accommodated, ifpossible.Note: Customer supplied key cylinders may beused to adapt NS400 Series locks to a specifickeying system. These cylinders must have:1. 1-5/32" diameter, full bar stock bodies.2. 1-1/8" length, including cam.

    3. Standard, removable Yale-type cam.Cylinders and all keys should be sent toSouthern Folger Detention EquipmentCompany and are required with cylinderextenders.

    Key cylinder extension Requiredwhen lock is keyed on the stop side ofthe door frame. Five standard lengthsare offered:Jamb CylinderSize Extension4-1/2" 5" 4-3/4"5" 6" 5-3/4"6" 7" 6-3/4"7" 8" 7-3/4"8" 9" 8-3/4"

    Note: Please specify appropriate cylinderextension length when ordering. Speciallengths may be provided for other jambthickness. Contact factory for pricing andavailability.

    Finish Key cylinder: US26D.

    FOLGER ADAM ELECTRIC LOCKSKey: Builders HardwareDoor: Swinging

    SecurityLevel: Minimum/Medium NS400MCD

    MOTOR-OPERATED DEADBOLTS

  • A30 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    Specifications_________ Lock case Investment-cast

    stainless steel.

    Deadbolt Investment-caststainless steel hardened.

    Deadbolt throw 3/4"

    Deadlock lever/operating lever Stainless steel.

    Strike Stainless steel stamping.

    ElectricalCharacteristics________ Motor High-torque,

    permanently lubricated,permanent magnet, planetarygearmotor, UL Listed.

    Voltage 24VDC or 24VAC 0.12running, 1.29 amps stalled.

    Indication switch SPDT, ULlisted.

    Switch rating 5 amp @ 125 or250 VAC.

    Dimensional Data________Note: Dimensions are for informationand planning purposes only, and shouldnot be used as templates.

    For complete details, see How toSpecify in this section.

    FOLGER ADAM ELECTRIC LOCKS Key: Builders HardwareDoor: Swinging

    SecurityLevel: Minimum/MediumNS400MCD

    MOTOR-OPERATED DEADBOLTS

    MODEL OPERATIONINDICATION

    SWITCHLATCHBACKWITHOUT

    LEKOPTION

    CONTINUOUSDUTY

    MODULATOR

    NS400MCD-04-01 Standard No No

    Feature/Option Chart

  • FA Rev. 02-10 A31

    For more information, please call 210.533.1231.

    FOLGER ADAM ELECTRIC LOCKS

    HOW TO SPECIFYNS400 SERIES LOCKS

    1 4

    2

    3

    5

    6

    7

    89

    10KeyingLocationNS400No Cylinder

    NS402Keyed 1 Side

    NS406Keyed 2 Sides

    Basic ModelsDeadlatches

    ESolenoid

    MMotor

    MC2-Position Motor

    DeadboltMCD

    2-Position Motor

    SwitchFunctions

    01Deadlock

    Indication SwitchWith Latchback

    04Deadlock

    Indication SwitchNo Latchback

    07Deadlock

    Indication SwitchNo Latchback

    Auxiliary SwitchFor ElectricHoldback

    09Deadlock

    Indication SwitchNo Latchback

    Auxiliary SwitchFor Electric

    RelockMode of

    Operation(E Solenoid Only

    For Fail-Safe)

    NFSNon-Fail-Safe

    FSFail-Safe

    CylinderOptions

    BCPrep For Builders

    HardwareCylinder,CustomerSupplied

    B2High Security

    Builders HardwareCylinder

    LatchboltHanding*

    RHRB LHRBRHSB LHSB

    DeadboltHanding

    LHRH

    Voltage

    Solenoid24 VAC24 VDC

    Optional

    Local ElectricKey

    Optional

    Inmate PushButton

    FaceplateFinish

    StandardUS32D

    11OptionalCylinderExtensionSelect StandardOffered Length

    1 2 3 4 5 6 7 8 9 10 11

    NS400 E FS 01 B2 RHRB 24 VAC LEK PB-1 US32D Cyl. Ext.5-3/4"

    * For application handing, see the handing chart on the following page.

  • A32 Printed in USA FA Rev. 02-10

    P.O. Box 2021, San Antonio, TX 78297 Ph: 210.533.1231 Fx: 210.533.2211Web: www.SouthernFolger.com Email: [email protected]

    FOLGER ADAM ELECTRIC LOCKS

    HOW TO SPECIFYNS400 SERIES LOCKS

    Specify circled swing number when ordering.

  • FA Rev. 11-12 A33

    For more information, please call 210.533.1231.

    Description______________Series 800 Deadlatches are levertumbler, solenoid operated locks forswinging or sliding chain-link fencegates. Specify keying as follows:

    For Swinging Gates:802ES-L Keyed cover side806ES-L Keyed both sides

    For Sliding Gates:802ER-L Keyed cover side806ER-L Keyed both sides

    Applications_____________For use on sliding or swinging chain-linkfence gates. Provide automaticdeadlocking with flexibility of remoteunlocking.

    Operation_______________This lock is electrically operated forunlocking. The deadbolt retracts whensolenoid is energized. Once retracted,deadbolt is held electrically retracteduntil gate is closed. Deadbolt extendsautomatically in case of power failure.Emergency mechanical operation byparacentric key.

    Testing__________________The 800 Series Electric Gate locks havebeen electrically tested for over1,000,000 operating cycles.

    Standard Features_______ Solenoid actuated 120 VAC, 60hz,

    continuous-duty type. Unlocking by prison paracentric key

    in case of power failure or for localcontrol. When unlocked by key,deadbolt remains retracted untilrelocked by key.

    Deadlocks automatically When gate is closed.

    Adjustable mounting and lockingtongue Fits fence posts between 2" and 8-5/8" diameter; gate postsbetween 1" and 4-1/4" diam