7/30/2019 Flush Bottom Valve
1/3
Page:1 of 3
As the name implies, the valve is fixed flush with the bottom portion of the dish, and ensuresminimum volume of reactants is held in the bottom nozzle. This avoids contamination and
eliminates unreacted (dead) volume. Spindle moves only in the vertical direction when the handwheel is operated.
For dimensions of standard valve, please refer page 2 of 3 this document.
For different models available, please refer page 3 of 3
Details of a few models:
Requirement Specify as Details of corresponding part
1
For sensing
temperatures at volumes
lower than can sensedby the conventional
thermowell
DV-TO-TS
SIZE
150 x 100100 x 8080 x 50
438 ml275 ml
936 ml
DEAD VOLUME
TANTALUM TIP DEAD VOLUME
2
For operating the valve
pneumatically (to avoid
human contact or for
remote operation)
DV-TO-AC
3
For reduced dead
volume in the valvebody (to avoid
contamination to the
subsequent batches /
processes)
DV-TO-BE
4
For frequent removal of
valve for cleaning
(when dead volume in
the bottom nozzle is
acceptable)
DV-BO-TS
5
For poking through thebottom nozzle to make
way through settled
reactants to facilitate
discharge (Pl. note that
discharge rate reduces
by 40%)
DV-TO-PK
Valves with more than one feature described above also can be supplied. Please contact us
for more details.
NILE LIMITED
FLUSH BOTTOM VALVETDC-07
ISSUE-2
http://whom_contact.pdf/http://whom_contact.pdf/http://whom_contact.pdf/ -
7/30/2019 Flush Bottom Valve
2/3
Page:2 of 3
PCD
C'
D
J
50
(LIFT)
K
PCD `B'
A
`E' Nos - `F' HOLES
`G' Nos. - `H' HOLES
80 x 50
100 x 80
150 x 100
A PCD `B' PCD `C' D E G F H J K
190 152.5 120.5 152 4 4 19 19 93 478
4229 190.5 152.5 190 8 19 19 104.5 508
8279 241.5 190.5 229 8 22 19 116 549
VALVE SEAT (PTFE)
SPINDLE(CS GL/SSGL)
VALVE BODY(CI GL/SS GL)
CHVRON PACKING(PTFE)
GLAND PUSHER (GUN METAL/SS)
BONNET ASSEMBLY (CI/SS )
HAND WHEEL (CI/SS )
FLUSH BOTTOM VALVENILELIMITED
TDC-07ISSUE: 2
*
* `K' will vary for actuated valves depending on the model of actuator.When fitted with temperature sensor, the hieght will increase by max. 200mm.
DIMENSIONS OF STANDARD VALVE
-
7/30/2019 Flush Bottom Valve
3/3
Page:3 of 3
NILE LIMITED
FLUSH BOTTOM VALVETDC-07
ISSUE-2
Models available in glass lined bottom discharge valve
Valves with more than one feature described above also can be supplied. Please
contact usfor more details.
S. No. MODEL DESCRIPTION / OPERATION
1 DV-TOSpindle moves upwards to open. In closed position, the PTFEvalve seat facilitates minimum dead volume.
2 DV-BOSpindle moves downwards to open. In closed position, media in
the nozzle remains as dead volume.
3 DV-TO-TS
Same as in DV-TO, but with temperature sensing arrangementwith Tantalum tip. Facilitates sensing of temperatures of thereactants at volume lower than sensing volume of thermowell /
baffle.
4 DV-TO-BESame as in DV-TO, but with bellow arrangement to minimize
retained material in the valve body.
5 DV-TO-BE-TS A combination of DV-TO-BE & DV-TO-TS
6 DV-TO-AC
Same as in DV-TO, but with pneumatic actuator to facilitate
remote operation & automation. This also provides safety forthe personnel.
7 DV-TO-PKSame as in DV-TO, but with a spindle that facilitates dislodgingthe chocked solids around the valve during its upward motionand clearing way for discharge, though at reduced rate.
8 DV-TO-PK-TS
Same as DV-TO-PK, but with temperature sensing arrangementwith Tantalum tip, for facilitating sensing of temperatures of the
reactants at volume lower than sensing volume of thermowell /baffle.
9 DV-TO-SN
Available in only SSGL construction. Operation is similar to thatof DV-TO, but with a nozzle of 20 NB size on the valve body.
This facilitates purging of gas to clear chocking in valve or
discharge line.