Flush Bottom Valve

download Flush Bottom Valve

of 3

Transcript of Flush Bottom Valve

  • 7/30/2019 Flush Bottom Valve

    1/3

    Page:1 of 3

    As the name implies, the valve is fixed flush with the bottom portion of the dish, and ensuresminimum volume of reactants is held in the bottom nozzle. This avoids contamination and

    eliminates unreacted (dead) volume. Spindle moves only in the vertical direction when the handwheel is operated.

    For dimensions of standard valve, please refer page 2 of 3 this document.

    For different models available, please refer page 3 of 3

    Details of a few models:

    Requirement Specify as Details of corresponding part

    1

    For sensing

    temperatures at volumes

    lower than can sensedby the conventional

    thermowell

    DV-TO-TS

    SIZE

    150 x 100100 x 8080 x 50

    438 ml275 ml

    936 ml

    DEAD VOLUME

    TANTALUM TIP DEAD VOLUME

    2

    For operating the valve

    pneumatically (to avoid

    human contact or for

    remote operation)

    DV-TO-AC

    3

    For reduced dead

    volume in the valvebody (to avoid

    contamination to the

    subsequent batches /

    processes)

    DV-TO-BE

    4

    For frequent removal of

    valve for cleaning

    (when dead volume in

    the bottom nozzle is

    acceptable)

    DV-BO-TS

    5

    For poking through thebottom nozzle to make

    way through settled

    reactants to facilitate

    discharge (Pl. note that

    discharge rate reduces

    by 40%)

    DV-TO-PK

    Valves with more than one feature described above also can be supplied. Please contact us

    for more details.

    NILE LIMITED

    FLUSH BOTTOM VALVETDC-07

    ISSUE-2

    http://whom_contact.pdf/http://whom_contact.pdf/http://whom_contact.pdf/
  • 7/30/2019 Flush Bottom Valve

    2/3

    Page:2 of 3

    PCD

    C'

    D

    J

    50

    (LIFT)

    K

    PCD `B'

    A

    `E' Nos - `F' HOLES

    `G' Nos. - `H' HOLES

    80 x 50

    100 x 80

    150 x 100

    A PCD `B' PCD `C' D E G F H J K

    190 152.5 120.5 152 4 4 19 19 93 478

    4229 190.5 152.5 190 8 19 19 104.5 508

    8279 241.5 190.5 229 8 22 19 116 549

    VALVE SEAT (PTFE)

    SPINDLE(CS GL/SSGL)

    VALVE BODY(CI GL/SS GL)

    CHVRON PACKING(PTFE)

    GLAND PUSHER (GUN METAL/SS)

    BONNET ASSEMBLY (CI/SS )

    HAND WHEEL (CI/SS )

    FLUSH BOTTOM VALVENILELIMITED

    TDC-07ISSUE: 2

    *

    * `K' will vary for actuated valves depending on the model of actuator.When fitted with temperature sensor, the hieght will increase by max. 200mm.

    DIMENSIONS OF STANDARD VALVE

  • 7/30/2019 Flush Bottom Valve

    3/3

    Page:3 of 3

    NILE LIMITED

    FLUSH BOTTOM VALVETDC-07

    ISSUE-2

    Models available in glass lined bottom discharge valve

    Valves with more than one feature described above also can be supplied. Please

    contact usfor more details.

    S. No. MODEL DESCRIPTION / OPERATION

    1 DV-TOSpindle moves upwards to open. In closed position, the PTFEvalve seat facilitates minimum dead volume.

    2 DV-BOSpindle moves downwards to open. In closed position, media in

    the nozzle remains as dead volume.

    3 DV-TO-TS

    Same as in DV-TO, but with temperature sensing arrangementwith Tantalum tip. Facilitates sensing of temperatures of thereactants at volume lower than sensing volume of thermowell /

    baffle.

    4 DV-TO-BESame as in DV-TO, but with bellow arrangement to minimize

    retained material in the valve body.

    5 DV-TO-BE-TS A combination of DV-TO-BE & DV-TO-TS

    6 DV-TO-AC

    Same as in DV-TO, but with pneumatic actuator to facilitate

    remote operation & automation. This also provides safety forthe personnel.

    7 DV-TO-PKSame as in DV-TO, but with a spindle that facilitates dislodgingthe chocked solids around the valve during its upward motionand clearing way for discharge, though at reduced rate.

    8 DV-TO-PK-TS

    Same as DV-TO-PK, but with temperature sensing arrangementwith Tantalum tip, for facilitating sensing of temperatures of the

    reactants at volume lower than sensing volume of thermowell /baffle.

    9 DV-TO-SN

    Available in only SSGL construction. Operation is similar to thatof DV-TO, but with a nozzle of 20 NB size on the valve body.

    This facilitates purging of gas to clear chocking in valve or

    discharge line.

    http://whom_contact.pdf/http://whom_contact.pdf/http://whom_contact.pdf/