fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP...

11
Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th 4+ in aqueous environment Selva Kumar R a and S.K. Ashok Kumar a * a Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore- 632014, Tamil Nadu, India. † E-mail: [email protected] 500 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 1/cm -0 20 40 60 80 100 %T 3269.34 2968.45 2899.01 1678.07 1666.50 1625.99 1595.13 1554.63 1516.05 1490.97 1409.96 1352.10 1300.02 1240.23 1157.29 1130.29 1072.42 1012.63 947.05 869.90 848.68 781.17 704.02 648.08 588.29 447.49 SK-SOLID Figure 1S. FTIR of 2-chloro-N-(quinolin-8-yl) acetamide Electronic Supplementary Material (ESI) for Dalton Transactions. This journal is © The Royal Society of Chemistry 2019

Transcript of fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP...

Page 1: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Electronic Supporting Information

Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Selva Kumar R a and S.K. Ashok Kumar a*a Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore-

632014, Tamil Nadu, India. † E-mail: [email protected]

5007501000125015001750200025003000350040001/cm

-0

20

40

60

80

100

%T

3269.34

2968.45

2899.01

1678.07

1666.50

1625.99

1595.13

1554.63

1516.051490.97

1409.96

1352.10

1300.02

1240.23

1157.29

1130.29

1072.42

1012.63

947.05

869.90

848.68

781.17 70

4.02

648.08

588.29

447.49

SK-SOLID

Figure 1S. FTIR of 2-chloro-N-(quinolin-8-yl) acetamide

Electronic Supplementary Material (ESI) for Dalton Transactions.This journal is © The Royal Society of Chemistry 2019

Page 2: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 2S. 1H NMR of 2-chloro-N-(quinolin-8-yl) acetamide

Figure 3S. 13C NMR of 2-chloro-N-(quinolin-8-yl) acetamide

Page 3: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 4S. DEPT-135 NMR of 2-chloro-N-(quinolin-8-yl) acetamide

Figure 5S. HR mass of 2-chloro-N-(quinolin-8-yl) acetamide

Page 4: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

5007501000125015001750200025003000350040001/cm

-0

20

40

60

80

100

%T

3336.85

2958.80

2873.94

1685.79

1597.06

1527.62

1485.191425.40

1382.96

1325.10

1246.02

1116.78

1060.85

1018.41

975.98

950.91

902.69

827.46

792.74

756.10

727.16 698.23

557.43 507.28

468.70

SK-L

Figure 6S. FTIR of spectra L

Figure 7S. 1H NMR spectra of L

Page 5: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 8S. 13C NMR spectra of L

Figure 9S. 31P NMR spectra of L

Page 6: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 10S. DEPT-135 NMR spectra of L

Figure 11S. HR mass spectra of L

Page 7: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 12S. UV-Vis spectral response of L with other metal ions in CH3CN:H2O (9:1, v/v)

Figure 13S. Change in absorbance at 240 nm of L (50μM) with Th4+ (0-50μM)

Page 8: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure. 14S. Fluorescence spectral change of L, L-Zr4+ and L-Ti4+ upon an excitation at 240 nm and 315 nm

Figure 15S. Change in emission at 486 nm of L (50μM) with Th4+ (0-50μM)

Page 9: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 16S. Time response curve of optode-10

Figure 17S. Dynamic emission response of optode-10

Page 10: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 18S. Lifetime study of optode-10 sensor

Page 11: fluorescent Optode for Th4+ in aqueous …Electronic Supporting Information Light activated CMP conjugated 8-aminoquinoline turn-on fluorescent Optode for Th4+ in aqueous environment

Figure 19S. LC chromatogram and mass spectra of L-Th complex