Fluke Power Quality
-
Upload
meg-jaskowiak -
Category
Technology
-
view
3.723 -
download
2
description
Transcript of Fluke Power Quality
©2006 June 2006 1
Fluke Power Quality1750 and 1740 Series Overview
©2006 June 2006 2
Types of Portable PQ Tools
Troubleshooters: instantly show measured results in a display.
Recorders: logs PQ measurements and captures detailed high resolution waveforms for analysis. Measured results can be analyzed and reports created on a PC
Loggers: logs PQ measurements (min, max, avg). Measured results can be analyzed and reports created on a PC.
©2006 June 2006 3
TroubleshootersFluke 345 Power Quality Clamp Meter
– power, energy, harmonics, inrush– 2000A ac or dc with large integrated clamp– long-term analysis with internal logging and analysis software– bright color display of waveforms, harmonics, and trends
Fluke 43B Power Quality Multimeter– transients, dips, swells, power, energy, harmonics, inrush– includes full-featured scopemeter and multimeter– long-term analysis with internal logging and analysis software– capture transients down to 40nS
Fluke 430 Series Three Phase Power Quality Troubleshooters– transients, dips, swells, power, energy, harmonics, inrush– Autotrend – every measurement is always recorded, without setup– troubleshoot real-time even while background recording continues– capture transients simultaneously on all three phases and neutral
©2006 June 2006 4
Loggers and Recorders
1740 Series Loggers 1750 Recorder
Validate Voltage Quality Diagnose Intermittent or Complex Issues
Recording Capabilitieslogs voltage, current power, energy, harmonics, dips, swells ● ●
thresholds user-defined threshold-free
event capture time, duration, magnitude time, duration, magnitude + waveform (5MHz)
Storage capacity 3 months (8Mb) 1 month (2,000 Mb)
Operationdisplay LEDs or LCD wireless PDA and LEDs
data retrieval USB / RS232 Ethernet or SD memory card
power supply powered by measured voltages independent input
Analysis and Reportingincluded analysis software ● ●
report-writer ●
©2006 June 2006 5
Fluke 1750 Power Recorder
The all-purpose recorder that does all the work for you
©2006 June 2006 6
Fluke 1750 Power Recorder• Quick and reliable configuration: PDA wireless
“front panel interface” provides a window into what the instrument is recording, even in awkward test locations
• Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyze Software
• Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time
• Intuitive PC software: Easily analyze data and generate reports
• Plug and play: Set up in minutes with self-identifying current probes and single-lead voltage connections
• Measure every parameter: voltage and current on three phases, neutral, and ground
• 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events
©2006 June 2006 7
Applications
Long-term analysis: Uncover hard-to-find or intermittent issues
Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports
Quality of service compliance: Validate incoming power quality at the service entrance
Semi-permanent monitoring: Monitor critical equipment, capturing power quality events to correlate with equipment malfunction
©2006 June 2006 8
Fluke 1750 – The Complete Package
Fluke 1750
PDA wireless front panelinterface
5 voltage leads and
clips
4 400A current clamps(ground clamp
optional)
Application and PDA software
SD flash memory card
©2006 June 2006 9
Easy to Setup
• Single lead voltage connections simplifies connections
• Self-identifying current probes eliminates setting current probe scaling
©2006 June 2006 10
Verify in Seconds
Wireless PDA interface enables safe and easy verification
– instantly provides a window into measurements
– confirm setup and swap channels from a safe distance
©2006 June 2006 11
Verify in Seconds
• Ethernet connection provides direct PC connection or remote connection over the internet
• LEDs indicate inputs are within range, bluetooth and ethernet connectivity, and recording status
©2006 June 2006 12
Threshold Free Operation
• Never miss capturing a disturbance - with the exclusive Full-Disclosure measurement system, it’s automatic
• The patented capture algorithms record everything for a month on the internal industrial 2Gb flash memory
• Fluke Power Analyze allows the user to adjust thresholds after recording is complete!
©2006 June 2006 13
Capture Everything
• Current and voltage triggering monitors for events on all channels
• Cross-channel triggering captures waveforms on all channels simultaneously
• Snapshot feature allows periodic analysis of waveforms
©2006 June 2006 14
Powerful Transient Capture
1000 1050 1100 1150 1200 1250 1300 1350 1400 1450-2500
-2000
-1500
-1000
-500
0
500
1000
1500
2000
2500
3000
3500
4000
Vo
lts
Selected Recorded Event Zoomed Detail -- 04/05/2006 13:31:20.304.976.400 - 04/05/2006 13:31:20.305.470.500 - Phase A Event, Amp = 4402.07
Tim e 04/05/2006 13:31:20.304000 + uS
• Analyze ringing of transients with 5Mhz resolution
• View lightening strikes with 8000V peak capture
©2006 June 2006 15
Download Data Quickly
Three quick and easy methods to retrieve data:– Use PDA to download data to included SD memory card
– Transfer directly to the PC via TCP/IP protocol
– Download over the network with 100Base-T Ethernet connection
©2006 June 2006 16
Full Suite of Accessories
Current Accessories• Flexible and clamp style probes from 5A
up to 5000A
• Precision current clamps down to 0.01A for secondary applications
Voltage Accessories• Everything from bus bar clamps to fused
test leads
• Compatible with all Fluke SureGrip accessories
Miscellaneous Upgrades• Watertight transit case with custom designed insert protects
the 1750 and accessories• Soft carry bag for the 1750 and accessories
©2006 June 2006 17
Fluke 1750 Power Recorder
The all-purpose recorder that does all the work for you
©2006 June 2006 18
Fluke 1740 Series Power Quality Logger
The power quality specialist’s logger for conducting long-term studies with ease
©2006 June 2006 19
Fluke 1740 Series• Plug and play: Setup in minutes with automatic
current probe detection and powering
• Installs inside the cabinet: Compact, fully insulated housing and accessories fit easily in tight spaces, next to live power
• Determines the root cause: Included PQ Log software quickly analyzes trends, creates statistical summaries, and generates detailed graphs and tables
• Monitors power for the long-term: Data can be downloaded during recording without interruption
• Measure voltage with premium accuracy: IEC61000-4-30 Class-A compliant voltage accuracy (0.1 %)
• Quickly validate quality of power: Assess power quality according to EN50160 power quality standard, with statistical overview
• Rugged and reliable: Designed for everyday field use, with no moving parts and durable, insulated case, with two year warranty
©2006 June 2006 20
Applications
Disturbance analysis — Uncover root cause of equipment malfunction for later mitigation and predictive maintenance
Quality of service compliance — Validate incoming power quality at the service entrance
Power quality studies — Assess baseline power quality to validate compatibility with critical systems, before installation
Load studies — Verify electrical system capacity before adding loads
Energy and power quality assessment — Validate performance of facility improvements by quantifying energy consumption, power factor,and general power quality, before and after improvements
©2006 June 2006 21
Selection Guide - 3 Models
1745 1744 1743
Measurement of common power parameters: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
● ● ●
Measurement of voltage and current harmonics to the 50th, unbalance, and mains signaling
● ●
Dust/water resistance IP 50 IP 65 weatherproof
Display LED + LCD LED
UPS ride-through 5 hrs 3s 3s
Dimensions (HxWxD) 282 x 216 x 74 mm
(11.5 x 8.8 x 3 in.)
170 x 125 x 55 mm
(6.9 x 5.1 x 2.2 in.)
©2006 June 2006 22
Fluke 1745 – Turnkey Solution
Flexible Current
Probe 15/150/1500/3000A
Fluke 1745
Power Cord (up to 660V or from a
wall outlet)
Voltage Probe
480V P-N; 830V P-P
PQ Log Software
(included)
©2006 June 2006 23
Fluke 1743/1744 Turnkey Solution
Flexi Current
probe 15/150/1500/3000A
Fluke 1743/4 (IP65 weatherproof)
Voltage probe
480V P-N; 830V P-P
without plug
PQ Log Software
(included)
Power Cord (up to 660V or from a
wall outlet)
©2006 June 2006 24
Measurement process 1
2 – Set up the logger and hook up instrument, check LED and start measurement
1 - Go on site 3 – Bring the logger back to office, download data and analyze
©2006 June 2006 25
Measurement process 2
2 - Go on site
3 – Hook up the logger, check LED and start measurement
4 – Bring the logger back to the office, download data and analyze
1 – Expert sets up the logger in the office
2 – Technician connects and retrieves 1740 on-site
©2006 June 2006 26
Flexible Power Supply Options
Option 1:
Piggy-back on measured voltages up to 660V
Option 2:
Use international adapters to power independently from wall outlets
©2006 June 2006 27
Fluke 1740 Series Power Quality Logger
The power quality specialist’s logger for conducting long-term studies with ease