Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters,...
Transcript of Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters,...
Fluid Service ProductsFluid Condition Monitoring & Contamination Control
Fluid Service Catalog2
Pulp and PaperLube oil circuits and hydraulic systems found inpaper mills benefit greatly from the implementationof HYDAC fluid service products as well asHYDAC filters, coolers, accumulators, and otherproducts. As with all industrial hydraulics and lubeoil circuits, it is crucial to keep the levels of bothwater and solid contamination to a minimum.
About HYDACHYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributorsworldwide and more than 40 wholly owned branches. HYDAC has been active in the field of fluid conditionmonitoring and filtration for more than 30 years and is a global leader in the design and production of suchproducts. The experience of our staff, and distributors become the customer’s asset when working with HYDAC.Controlling contamination is crucial to fluid power systems — Let the experts at HYDAC help!
Power GenerationHYDAC Fluid Service Products play a key role in providing system maintenance and monitoring inpower generation plants. By implementing acomprehensive filtration & fluid condition monitoringprogram these systems will operate more efficiently,and downtime and component failure will be reduced.
Mobile MarketOur rugged, portable contamination monitors alloweasy field use to check oil cleanliness. OEM’s useour products to verify and document that equipmentis leaving the factory with clean oil. Our portable fil-tration units are ideal for correcting extreme waterand contamination problems caused by the severeenvironments in which these machines operate.
Steel & Heavy IndustryMaintaining clean hydraulic systems in steel millsand other heavy industrial plants is very important.The use of HYDAC fluid service products will helpkeep these operations running smoothly and effi-ciently, by reducing costly system and componentfailures. Investment in these products can easily bejustified by the resulting cost savings.
Offshore Shipbuilding and Marine TechnologyHYDAC offline filtration units protect the hydraulicsystems of cranes, blow-out preventors, motioncompensators, thruster and ballast controls, and risertensioning systems on offshore drilling rigs. Our compact offline filter is available in an explosionproof (intrinsically safe) version, making it ideal for usein any industry where volatile gasses may be present.
Plastics Injection molding and blow molding machines, areall perfect candidates for the supplemental filtrationloops that HYDAC can help you install. Whenmachine downtime is a problem, HYDAC’s fluidservice product are the solution!
HYDAC ProductsOur product range includes portable and online contaminationmonitors and water content sensors, as well as portable andpermanent offline filters. For more critical applications, we offerin-depth analysis kits which return detailed reports about thecondition of a system’s fluid.
HYDAC Customer ServiceOur internal staff and worldwide distribution network take care ofthe important matter of customer service. HYDAC values highstandards, professional ethics, and mutual respect in all transactionswith customers, vendors, and employees. We invest in our relationshipsby providing expertise, quality, dependability, and accessibility tofoster growth and a sense of partnership. Our customer servicerepresentatives are committed to serving the customers’ needs.
HYDAC QualityHYDAC stands for quality and customer satisfaction. This quality isthe result of constant research and development combined with 35years of global application experience and know-how. Our productsare designed to be reliable and cost-effective solutions for monitoringand maintaining hydraulic and lube oil cleanliness.
Fluid Service Catalog
Fluid Service
1-877-GO HYDAC
IntroductionGeneral Introduction .............................1Cost Savings Calculations ....................2ISO Cleanliness Levels .........................3
Offline FiltersOF5 [Filtromat] ....................................39OLF .....................................................41OLF compact ......................................45
Water Content ControlNegative Effects of Water ...................37AS series [water content sensor] ........13AS1000 series [water sensor] .............15FAM [water & solid removal] ...............35WTK [water test kit].............................24Aquamicron® Elements .......................50
Replacement ElementsReplacement Elements .......................49Aquamicron® .......................................50Betamicron® ........................................50Betafit Interchange Elements..............50
Other Products from HYDACCoolers................................................51Filters...................................................51Reservoir Accessories ........................51Complete Line Card ..............back cover
Portable FiltersOF7 [hand-held] ..................................27OF5 [wheeled carts] ............................29FCC [compact fluid carrier].................31FCM [mobile fluid cleaner] ..................33FAM [water & solid removal] ...............35
Fluid Analysis Fluid Analysis Service .........................19FES [fluid sampling kit] .......................23WTK [water test kit].............................24FAS [fluid analysis kit] .........................25Measuring Microscopes......................26
Contamination Monitors & DiagnosticsFCU series [portable particle counter] ..5CS series [permanent particle counter] 9CS1000 series [contamination sensor]11AS series [water content sensor] ........13AS1000 series [water sensor] .............15HMG series [portable data recorder] ..17
All information is subject to change without notice.
Fluid Service Catalog
Fluid Service
1
IntroductionContamination and degraded fluid quality cause inefficientoperation, component wear, and eventually failures in allhydraulic and lubrication systems. The products in thiscatalog are the tools that are needed to prevent suchoccurances. HYDAC Recommends a three step approachto controlling contamination in any system:
• Assess
• Recommend & Implement
• Monitor & Maintain
AssessStart by gathering complete information on the system.This includes:• a list of the most critical components• the mfg’s recommended ISO class for each component• the type of oil being used• flow rate & operating pressure• fluid temperature & ambient temperature• system’s operational characteristics• details on all current filters in the system• solid contamination levels (ISO class)• water content levels• details on all current filters in the system
Recommend & ImplementNext, specify your recommendations for upgradingthe current filtration, and adding the appropriatesupplementary filtration:• pressure filters• return line filters• manifold cartridge/circuit protector filters• element micron rating• reservoir breathers or filler breathers• strainer baskets• addition of offline filtration loop• use of portable filters for filling/temporary offline loops• sufficient water removal protection• proper fluid monitoring devices
Monitor & MaintainFinally, use reliable methods for continuous monitoring ofthe fluid conditions including:• solid contamination• water content• additive depletion• element clogging• periodic detailed analysis of actual fluid samples• portable filters for correcting unacceptable levels
The FCU portable particle counter
OLF 15 installation
Microscope with camera attached to a monitor
Fluid Service Catalog
Fluid Service
21-877-GO HYDAC
Savings Realized by ProperContamination ControlThe money invested in contamination control can easily bejustified when the resulting machine availability increasessignificantly. The graph below illustrates that there is arange in which this investment really pays off.
Savings Calculation ExampleThis example demonstrates how to calculate the potentialsavings that will be realized by implementing a proper fluidservice program.
Example Your Data
Number of Machines 50 a ________
Operating Hours per year 5,000 b ________
Current Availability 92% c ________
Downtime Costs per hour $60 d ________
Total Downtime Costs $1,200,000 e ________ (a x b x (100 - c) x d)100
Downtime costs due to:
- mechanical/electrical failures (65%) $780,000 f ________ (e x .65)
- hydraulic failures (35%) of which: $420,000 g ________ (e x .35)
- 70% is due to the fluid $294,000 h ________ (g x .70)
- 30% is caused by other faults $126,000 i ________ (g x .30)
HYDAC Fluid Service can return 90%of the fluid related downtime costs $264,600 j ________ (h x .90)
Machine Availibilty in %
Solid
Part
icle
Con
ten
t /
mg
Economic Range
Try our automated savings calculator at:
click products > fluid service products
Example: larger than 4µm = 22,340larger than 6µm = 1,950larger than 14µm = 43
ISO Code = 22 / 18 / 13
13
18
282726252423222120191817161514131211109876543210
2,500,0001,300,000
640,000320,000160,000
80,00040,00020,00010,000
5,0002,5001,300
640320160
80402010
52.51.3
0.640.320.160.080.040.020.010.00
> 4 µm > 6 µm > 14 µm
22
Fluid Service Catalog
ISO Cleanliness Levels
3
How the ISO 4406 Code works:Cleanliness levels are defined by three numbers divided byslashes (/.) These numbers correspond to 4, 6, and 14micron, in that order. Each number refers to an ISO RangeCode, which is determined by the number of particles forthat size (4,6, & 14µm) and larger present in 1 ml of fluid.Each range is double the range below. Refer to the chartbelow to see the actual ranges.
Achieving the appropriate cleanliness level in a system:The only way to achieve and maintain the appropriate cleanliness level in a hydraulic or lubrication system,is to implement a comprehensive filtration program.
HYDAC offers all of the products that are needed to do just that! - They include:
Solid Contamination:• pressure filters
• return line filters
• offline filtration loops
• oil transfer units for precleaning of new oil
• portable and online contamination monitors
• reservoir breathers and filler/breathers
Water Content:• water content sensors
• reservoir breathers with silica gel desiccant
• vacuum dehydration water removal units
• water removal elements
Fluid Analysis:• bottle sampling kits
• complete analysis kits
14/12/9
17/15/12
20/18/15
23/21/18
Fluid Service Catalog
ISO Cleanliness Levels
4
TISOarget
Levels
ISO
Low/Medium PressureUnder 2000 psi(moderate conditions)
High Pressure2000 to 2999 psi(or low/medium with severe conditions1)
Very High Pressure3000 psi and over(or high pressure with severe conditions1)
TargetLevels
TISOarget
LevelsMicronRatings
MicronRatings
MicronRatings
PumpsFixed Gear or Fixed Vane 20/18/15 20 19/17/14 10 18/16/13 5
Fixed Piston 19/17/14 10 18/16/13 5 17/15/12 3Variable Vane 18/16/13 5 17/15/12 3 not applicable not applicable
Variable Piston 18/16/13 5 17/15/12 3 16/14/11 3(2
ValvesCheck Valve 20/18/15 20 20/18/15 20 19/17/14 10
Directional (solenoid) 20/18/15 20 19/17/14 10 18/16/13 5Standard Flow Control 20/18/15 20 19/17/14 10 18/16/13 5
Cartridge Valve 19/17/14 10 18/16/13 5 17/15/12 3Proportional Valve 17/15/12 3 17/15/12 3 16/14/11 3(2
Servo Valve 16/14/11 3(2 16/14/11 3(2 15/13/10 3(2
ActuatorsCylinders, Vane
20/18/15 20 19/17/14 10 18/16/13 5Motors, Gear MotorsPiston Motors, 19/17/14 10 18/16/13 5 17/15/12 3
Swash Plate MotorsHydrostatic Drives 16/15/12 3 16/14/11 3(2 15/13/10 3(2
Test Stands 15/13/10 3(2 15/13/10 3(2 15/13/10 3(2
BearingsJournal Bearings 17/15/12 3 not applicable not applicable not applicable not applicable
Industrial Gearboxes 17/15/12 3 not applicable not applicable not applicable not applicable
Ball Bearings 15/13/10 3(2 not applicable not applicable not applicable not applicable
Roller Bearings 16/14/11 3(2 not applicable not applicable not applicable not applicable
1-877-GO HYDAC
Finding the cleanliness level required by a system:1. Starting at the left hand column, select the most sensitive component used in the system.
2. Move to the right to the column that describes the system pressure and conditions.
3. Here you will find the recommended ISO class level, and recommended element micron rating.
1. Severe conditions may include high flow surges, pressure spikes, frequent cold starts, extremely heavy duty use, or the presence of water2. Two or more system filters of the recommended rating may be required to achieve and maintain the desired Target Cleanliness Level.
FREE Poster!The information on these two pages is also available on our ISO Cleanliness Guidelines poster.Visit our web site to request your FREE copy.
Fluid Service Catalog
Contamination Monitors
5
Description:The FCU 2000 Series Fluid Control Unit is the second generation of diagnostic equipment for measuring and controlling contamination in hydraulic and lubrication systems. These Units are portable, which makes them ideal for use on multiple machines in a plant, or in-the-fielduse. The rugged construction incorporates a folding handlewhich also serves as a prop stand for optimal viewing.
Online Measurement:A key advantage of the FCU is that it allows the user tomeasure changes in contamination instantaneously as theyoccur. The unit continuously detects solid particles and displays the results in cleanliness classes according to ISO4406 (1992 or 1999), SAE AS 4059 or NAS 1638 standards.
Tank Extraction/Bottle Sampling:The FCU 2000-4 model is equipped with a specific suctioninlet and an integrated pump for reservoir and bottle extraction,in addition to the standard online measurement capability.
Comprehensive Reporting:Measurements are automatically stored in memory and canbe used to print tabular and graphic reports in a wide varietyof formats. Although extensive functions for data recordingand documentation are available, clear built-in menus makeit easy for a user to develop highly informative reports withminimal training.
PC Capability:For many applications, the built-in printer will produce thenecessary reports. In addition, data can be transmitted to aPC via an RS232C interface, providing the user with flexibilityin analysis with the supplied CoCos light software package,or with standard packages like MS-EXCEL.
Contamination Control:By means of control software, the user can program theFCU to activate an auxiliary filtration unit through built-inrelays when contamination reaches a specified maximumlevel. This makes it possible to control system cleanlinessreliably and automatically.
The FCU also can be programmed to de-activate an off-lineunit when contamination reaches a preset target level, anespecially useful feature in flushing operations.
Applications:The versatility and simplicity of the FCU 2000 Series isadvantageous in various applications:
• Preventive Maintenance
• Field Service
• System Production and Testing
• Fluid Cleanliness Documentation
• Flushing Process Control
FCU series Fluid Control Units
FCU 2000-4FCU 2000-1
Fluid Service Catalog
Contamination Monitors
61-877-GO HYDAC
FCU 2100 FCU 2200Particle size channels 2µm / 5µm / 15µm / 25µm 4µm(c) / 6µm(c) / 14µm(c) / 21µm(c)
Measurement Range NAS 2 to 12 SAE 2 to 12ISO 13/11/10 to 23/21/18 ISO 13/11/10 to 23/21/18
Indication Range NAS 2 to 15 SAE 2 to 15ISO 12/10/9 to 25/23/21 ISO 12/10/9 to 25/23/21
Accuracy ± 1/2 class (ISO, NAS, SAE)
Calibration ISO 4402 ISO 11943
Recalibration Recommended every 2 years
Log Memory Can accommodate up to 3000 measured values / 100 Test Headers
Inlet Operating Pressure 45 to 5000 psi
Outlet Flow Rate 800 ml/min max
Outlet Operating Pressure max 45 psi back pressure
Measurement Flow Rate 50 - 150 ml/min
Permissible Viscosity Range 1 to 1000 mm2/sec (inlet port, see graph below) / 1 to 150 mm2/sec (suction port, continuous operation) /
150 to 350 mm2/sec (suction port, brief operation, 10 min.)
Fluid Temperature Range 32° to 160° F
Supply Voltage 24 V DC, ± 25% or 110 V AC with supplied adapter
Wattage 25 W max 100 W max
Battery Powered Measurement without pump or pump supplied externally: up to 6 hoursOperating DurationSerial Port RS 232 with 15-pin Sub D plug
Ambient Temperature Range 0° to 130° F
Storage Temperature Range -4° to 185° F
Relative Humidity max 90%, non-condensing
Protection Type IP40
Weight ≈ 30 lbs
The minimum inlet pressure required to achieve a flow rate of 100 ml/min for a given viscosity can be found byreferring to the graphic below. The required inlet pressure increases with increasing clogging of the filter element.
Technical Data:
0
375
300
225
150
75
0
450
1000 2000 3000
Viscosity / SUS
Pressure Required at the FCU High-Pressured Port(inlet) for a Flow Rate of 100 ml/min
(Flow regulator opened, new filter element)
Pre
ssur
e /
psi
4000 5000
FCU 22 10 1 K KIT
SeriesFCU = Fluid Control Unit
Model21 = 3 digit ISO 4406 Code (>2/>5/>15µm) and NAS 163822 = 3 digit ISO 4406 Code (>4/>6/>14µm) and SAE AS 4059
Media10 = Mineral Oil11 = Phosphate Ester/Skydrol (not available with pump option -4)
Options1 = Standard4 = Integrated Pump
Supply VoltageK = 110V
Component PackageKIT = Includes Components• Minimess Adapter to SAE-6• One Inlet and One Outlet Hose• Software Package - Download from www.hydac.com (CoCos light)• PC Cable• Power Adapter• Instruction Manuals• Shipping Case
Additionally for FCU 2xxx-4:• Second power adapter• Suction hose 6mm bore (1m length)• Suction hose 6mm bore (0.2m length)
FCU Accessories Part NumberAluminum Transport Case for FCU-1 Series 00349153
Aluminum Transport Case for FCU-4 Series 03040814
Printer Paper (5 rolls) 00349155
Printer Ink Ribbon 00349156
Line Adapter 110V 03090803
High Pressure Hose (2 meters / 6.5 feet) 00349150
Return Hose (2 meters / 6.5 feet) 00349151
Fluid Service Catalog
Contamination Monitors
7
Model Code:
FCU Accessories:
Fluid Service Catalog
Contamination Monitors
81-877-GO HYDAC
mode
7
memory
8
9
limits
4
setup
5 6
ISO
1
NAS
2 3
0
okstart
stop
-
+
+-
Flow ControlFluid Control Unit
10.0"(254 mm)
5.6"(142 mm)
12.4"(315 mm)
12.3"(312 mm)
18.0"(457 mm)
Caution!Do notlock OUTLET
Max. 3bar 43 PSI
INLETMax. 350bar 5000 PSI
O / I POWER INPUT24 V= / 1 A
Filter Element0060 D 005 BN/HC
PC CONTROL
A B
C
D E
F
G
H
Dimensions: FCU 2000-1 FCU 2000-4
mode
7
memory
8
9
limits
4
setup
5 6
ISO
1
NAS
2 3
0
okstart
stop
-
+
+-
Flow ControlFluid Control Unit
14.3"(364 mm)
5.8"(148 mm)
16.5"(419 mm)
Filter Element
12.3"(313 mm)
17.7"(450 mm)
OUTLETMax. 3barMax. 43 PSI
INLETMax. 350barMax. 5000 PSI
INLETMax. 350barMax. 5000 PSI
O / I
POWER INPUTPump24 V-2.3A
POWER INPUT24 V-/1A
Filter Element0060 D 005 BN/HC
PC CONTROL
A B C D E
F
G
HI JKL
CautionDo notlock
SUCTIONINLET
SUCTIONINLET
A = Outlet (return flow to tank)B = Inlet (high pressure port)C = Filter CoverD = On/Off SwitchE = Power Supply Connection (main)F = PC Connector (serial port)G = Control ConnectorH = Case Ground
A = Suction Inlet (suction port)B = Outlet (return flow to tank)C = Inlet (high pressure port)D = On/Off SwitchE = Power Supply Connection (main)F = PC Connector (serial port)G = Control ConnectorH = Power Supply Connection (pump)I = Filter CoverJ = Case GroundK = Ball Valve (for INLET/high pressure port)L = Ball Valve (for SUCTION INLET/suction port)
Fluid Service Catalog
Contamination Monitors
9
Description:The CS Contamination Sensor is a new solid contaminationsensor for detecting and monitoring solid contamination inhydraulic, lube and fuel oil. The CS Sensor continuouslymonitors the condition of the fluid and transmits the infor-mation to a variety of devices in real-time!
The data can be transmitted in various formats, allowingthe user to display contamination levels, program alarmsand/or warnings, activate or de-activate auxiliary filtrationloops, or examine via HYDAC software.
The Sensor technology used is the same as that in ourportable FCU series contamination monitors and has beenproven as a successful means of detecting solid contami-nation particles.
The HYDAC sensor concept provides a distinct durabilityadvantage. The CS Sensor is NOT sensitive to vibration,optical system contamination, pressure pulsations, fluidcolor, turbidity, or continuous high fluid temperatures.
Applications:This unit can be applied to any hydraulic system in whichcontamination monitoring is critical. It is designed for per-manent installation in the system. Common applications ofthe CS Sensor Include:
• Lube-oil systems
• Paper mills
• Power generation plants
• Steel mills
• Flushing Process Control
• Fuel oil systems
CS series Contamination Sensors
WarningLamps
PLC
User’sSoftware
HYDACSoftware
ISO Code Displays
Features:• Online installation
(pressures up to 5000 psi w/ external relief)
• 4-bolt cushioned mounting
Data Output To:• PC - via HYDAC software (included)
• Programmable logic controllers (PLC)
• Warning lamps via relays
• Local ISO class display (customer supplied)
• 4 to 20mA or DIN-Messbus or Ethernet
Fluid Service Catalog
Contamination Monitors
101-877-GO HYDAC
CS 21 3 0 - 1 - U / -1 -2
SeriesCS
Model21 = 3 digit ISO 4406 Code (>2/>5/>15)22 = 3 digit ISO 4406 Code (>4/>6/>14)
Enclosure3 = Stationary
Fluids0 = Standard mineral fluids and mineral based synthetics1 = Phosphate esters (e.g. Skydrol, Hyjet)
Modification Number1 = Standard
Supply VoltageU = 24 VDC
Pressure Range1 = 280-560 psi (for pressures from 560 to 5000 psi see below*)2 = 70-210 psi3 = 28-140 psi
Output0 = RS232 (DIN-66348 protocol) (enables easy communication with Hydac Software (CoCoS)1 = 4 - 20 mA2 = DIN-Messbus (enables communication with HYDAC software)5 = Ethernet
* For pressures above 560 psi - Reduce the pressure to between 280 and 560 psi. Please contact HYDAC for details.
Model Code:
35mm(1.38")
22mm(0.87")
Power Signal
194mm(7.64")
209mm(8.23")
134mm(5.276")
65mm(2.56")
105mm(4.13")
25mm(0.984")
15mm(0.59")
173mm(6.81") M6
38mm(1.5")
1/4" BSPPInlet
1/4" BSPPOutlet
Dimensions:
Fluid Service Catalog
Contamination Monitors
11
Description:The CS 1000 Contamination Sensor is the newest HYDACdevelopment for continuous measurement of solid contam-ination of fluids on the market.
The latest technology and materials combine with proventechniques make the CS 1000 a small, reliable measuringinstrument that is permanently mounted on your mobile orindustrial applications.
The attractive cost-to-performance ratio makes it especiallyinteresting for OEM applications. Online, real-time conditionmonitoring allows you to have total predictive maintenance.
Applications:Monitoring system on OEM vehicles such as
• Construction equipment• Agricultural machinery• Mobile and stationary mining equipment
Industrial hydraulic systems• Integration in Monitoring Systems
via 4 to 20mA.
Combination with filter unit
CS 1000 series Contamination Sensors
Technical Details:Self-diagnosis continuously with error
indication via status LEDMeasuring range Display up to class ISO 28/27/26
Calibration within the range ISO13/11/10 to 23/21/18
Operation pressureInlet 450 bar max / 6550 psi maxOutlet 450 bar max / 6550 psi maxConnectorsInlet Thread G 1/4, ISO 228Outlet Thread G 1/4, ISO 228Sensor flow rate 30 - 300 ml/minPermissible viscosity range 1 - 1000 mm2/s 15-5000 SUSFluid temperature range 0 to 85°CPower supply voltage 9 - 36 VDC, residual ripple < 10%Power consumption 3 Watt maximumElectrical specification
4 to 20 mA output: Max. 330Ω0 to 10 V output: Min. 820ΩMax. current 1.5 A
Electrical outputsAnalog Interfaces SAE A-D (Default),
SAE-Code (A/B/C/D), ISO-Code, Temperature
Limit Switching Output SAE A-D (Default), SAE-Code (A/B/C/D),ISO-Code, Temperature
RS485 (reserved for future use)Hydac Single Wire Interface (for HMG 3000)
Ambient temperature range -30° to 80°CStorage temperature range -40° to 80°CRelative Humidity max. 95%, non-condensingMaterial of sealing FPMElectrical safety class III (low voltage protection)
IP class IP67Weight 1.3 kg
We do not guarantee the accuracy or completeness of this informa-tion. The information are based on average working condition. Forexceptional operating conditions please contact our technicaldepartment. All details are subject to technical changes.
Features:• Version with or without display• Measurement of solid particle contamination
in hydraulic and lubricating fluids • Compact and rugged design• Type of protection IP67• Max. pressure 6500 psi (450 bar)• External flow condition
avoids internal clogging of orifices• Voltage supply 9-36VDC• Data output 4-20mA, customized• Display with 6-digit ISO Code (optional)
• Display with pivot-functionwithout display
with display
Fluid Service Catalog
Contamination Monitors
121-877-GO HYDAC
CS 1 2 2 0 - A - 0 - 0 - 0 - 0 / - 000
SeriesCS = Contamination Sensor
Resolution1 = 4 Particle Size Channels
Indicator Code2 = ISO 4406 : 1999; SAE AS 4059 (D)
>4 µm( c) >6 µm( c) >14 µm( c)>21 µm( c)
Options1 = without Display2 = with Display
Fluids0 = based on mineral oil1 = for Phosphate Esters
Analog InterfacesA = 4 to 20 mAB = 0 to 10 V
Switching Output0 = Limit Switching Output
Digital Interfaces0 = RS485 (reserved for future use)
Electrical Connection0 = Plug M12x1, 8-pole (connector not included)
Mounting0 = Pipe mounting / Wall mounting1 = Flange mounting
Modification Number000 = standard
Scope Of Delivery- CS- Manual- Calibration Certficate
Accessories- Connection cable 2m with M12x1 connector, 8-pole- Connection cable 5m with M12x1 connector, 8-pole
Model Code:
0.79”(20mm)
2.36”(60mm)
ø 0.20”(5mm)4 Place’s
4.19”(106.5mm)
3.27”(83mm)
30°
2.15”(54.5mm)
ø 0.35” (9mm) thruCounterbore
ø 0.59” x 0.31”(15mm x 8mm) DP
Contamination Sensor CS
ISO SAE Flow Out Drive Temp
Esc o.k.
SP1
Status
SP2
Dimensions:
Fluid Service Catalog
Contamination Monitors
13
Description:The AS2000 series AquaSensors are stationary, microprocessorbased measurement units for the continuous monitoring ofthe water saturation level and temperature in hydraulic andlubrication systems. The saturation level indicates the percentage of maximum possible water is dissolved in theoil. A reading of 0% would indicate an oil free of water,while a reading of 100% would indicate oil that is saturatedwith water. The saturation level and temperature are reportedcontinuously to the integrated display and alarm relays andcan be captured via PLC, PC, etc.
Water in Oil:It is almost certain that there is water present in hydraulicand lubrication systems. These systems should be operatedwithout the presence of free or emulsified water. The mostcommon sources of water entering a system are ambienthumidity, “splash” from process water, and new oil. Watercontamination will accelerate the aging process of the oilresulting in oil oxidization, additive depletion, reduced lubrication, corrosion and damaged components. Most ofthese costly problems can be avoided by monitoring thewater content of the operating fluids.
Sometimes the water content is difficult to determine, butwith the new AquaSensor, determining the amount of wateris easy! The most practical method for monitoring watercontent in oil is as a percent of the saturation level.Different oils are capable of dissolving varying amounts ofwater, therefore they have varying water saturation curves.The curve to the right is an example of the typical relationship of water saturation level versus fluid temperature in hydraulic and lubrication oils. By looking atthe example graph it can be seen that this fluid is capableof holding more water, or has a higher saturation level, asthe temperature increases.
AS series AquaSensor Water Content Sensors
The AquaSensor is available in only one version with the following specifications:Measuring Range 0-100% %Saturation (%S)
-4° to 250°F (-20° to 120°C)
Accuracy +/- 2%S, +/- 4°C
Power Supply 24 V DC
Analog Outputs 4 - 20 mA for %S and Temperature
Alarm Relays 2 x %Saturation / 2 x Temperature
Serial Interface RS485
Display With display for %S and temperatureand keys to program the alarm relays
Sensor Cable Length 3 meters (9.8 feet)
Probe Stainless Steel, 210mm (8.27 in) in length
Operating Pressure -7.25 to 145 psi (-0.5 to 10 bar)
Fluids Mineral oils, Gear oils, Synthetic Esters
Connection G1/2 BSPP
Protection IP65
Flow Velocity max 4.5 m/sec
Fluid Temp Range 41° to 194°F (5° to 90°C)
Ambient Temp Range 14° to 158°F (-10° to 70°C)
Technical Details:
1200
1000
800
600
400
200
01048668503214-4 122
Dissolved Water
Temperature in °F
Wat
er C
onte
nt in
PP
M
Free and Emulsified Water
Example of a Hydraulic Oil Saturation Curve
Fluid Service Catalog
Contamination Monitors
141-877-GO HYDAC
Model Code:AS 2 3 3 0 - 1 - U
TypeAS = AquaSensor
Measuring Range2 = Saturation level 0-100%; temperature -20 to 120°C
Version0 = 4-20mA output3 = 4-20mA output + display + RS485 interface + switch outputs
Enclosure3 = For stationary use
Fluids0 = For standard mineral fluids
Length of Cable (up to tip of probe)1 = 3000 mm
Supply VoltageU = 24 VDC
Dimensions:
Scope Of Delivery
- AS
- Stainless steel screw connection 1/2“ with cutting ring
- Manual
esc
AquaSensor
esc
AquaSensor
ø 0.47" 12mm
G 1/2
8.27"210mm
2.09"53mm
4.21"107mm
5.51"140mm
4.21"5mm
1.61"41mm
4.72"120mm
0.20"5.1mm
3.25"82.5mm
5.12"130mm
Fluid Service Catalog
Contamination Monitors
15
Description:The AS 1000 series AquaSensors are stationary, microproces-sor based measurement units for the continuous monitoringof the water saturation level and temperature in hydraulicand lubrication systems. The saturation level indicates the percentage of maximum possible water is dissolved in theoil. A reading of 0% would indicate an oil free of water,while a reading of 100% would indicate oil that is saturatedwith water. The saturation level and temperature are out-putted as 4 to 20mA signal.
Water in Oil:It is almost certain that there is water present in hydraulicand lubrication systems. These systems should be operatedwithout the presence of free or emulsified water. The mostcommon sources of water entering a system are ambienthumidity, “splash” from process water, and new oil. Watercontamination will accelerate the aging process of the oilresulting in oil oxidization, additive depletion, reduced lubrication, corrosion and damaged components. Most ofthese costly problems can be avoided by monitoring thewater content of the operating fluids.
Sometimes the water content is difficult to determine, butwith the new AquaSensor, determining the amount of wateris easy! The most practical method for monitoring watercontent in oil is as a percent of the saturation level.Different oils are capable of dissolving varying amounts ofwater, therefore they have varying water saturation curves.The curve to the right is an example of the typical relationship of water saturation level versus fluid temperature in hydraulic and lubrication oils. By looking atthe example graph it can be seen that this fluid is capableof holding more water, or has a higher saturation level, asthe temperature increases.
AS 1000 series AquaSensor
Measuring range Temperatur: -25° to 100°CSaturation level: 0 to 100%
Operating pressure -0.5 to 50 bar (-0.05 to 5 MPa)
Burst pressure max. 630 bar
Flow velocity max. 5 m/sec
Nominal temperature range 0° to 90°C(when measuring saturation level)
Fluid temperature range -40° to 125 °C
Ambient temperature -40° to 100 °C
Viscosity range 1 to 5000 mm2/s 15-25000 SUS
Permissible fluids Fluids based on mineral oil andsynthetic and natural esthers
Parts in contact with fluid Stainless steel, FPM (AS1008)/ EPDM (AS1108) seal, vacuum metallized ceramic
Mechanical connection G 3/8A DIN 3852
Torque rating approx. 25 Nm
Weight approx. 145 g
Protection class IP67
CE mark EN 50081-1, EN 50081-2, EN50082-1, EN 61000-6-2
Reverse polarity protection of thesupply voltage, excess voltage, Standard override and short circuit protection
Supply voltage 12 to 32 V DC
Residual ripple ≤ 5 %
Output data
Saturation level 4 to 20mA (0 to 100%), calibrated accuracy≤ ±2% FS max., accuracy when measuringin fluid ≤ ± 3 % FS typically, pressuredependence +0.02% FS/bar
Temperature 4 to 20mA (-25° to 100°C), accuracy ≤ ± 2 % FS max.
Technical Details:
note: FS (Full Scale) = relative to the full measuring range
1200
1000
800
600
400
200
01048668503214-4 122
Dissolved Water
Temperature in °F
Wat
er C
onte
nt in
PP
M
Free and Emulsified Water
Example of a Hydraulic Oil Saturation Curve
Fluid Service Catalog
Contamination Monitors
161-877-GO HYDAC
Model Code:AS 1 0 0 8 - C - 000
TypeAS = AquaSensor
Series1 = 1000 series
Fluids0 = based on mineral oil1 = phosphate esters (HFD-R)
Mechanical Connection0 = G 3/8A DIN 3852
Electrical Connection8 = Plug M12x1, 5-pole (connector not included)
Signal TechnologyC = Saturation level 4 to 20 mA (0 to 100%), Temperature 4 to 20 mA (-25° to 100°C)
Modification Number000 = Standard
Items supplied• AquaSensor• Manual
Dimensions:
Accessories:ZBE 08Right-angled connector(5 pole, M12x1)ZBE 08S-02Right-angled connector(5 pole, M12x1) with 2 mcable, screened(ZBE 08-02, not screened)
ZBE 08S-05Right-angled connector(5 pole, M12x1) with 5 mcable, screened(ZBE 08-05, not screened)
ZBE 08S-10Right-angled connector(5 pole, M12x1) with 10m cable, screened
ZBE 08
ZBE 08S
Circuit Connection:
ø 0.47"(12mm)
0.86"(21.9mm)
1.16"(29.5mm)
2.18"(55.3mm)
G 3/8 A
2.64"(67.1mm)
1.18"(30mm)
0.47"(12mm) 0.10"
(2.5mm)
ø 1.06"(27mm)
SW 27
SignalSaturation Level
SignalTemperature
RL
RL
1
5Pin 5 not to be connected
2
4
3Ground
+ Ub
AS 1000
1.04"(26.5mm)
1.24"(31.50mm)
1.38"(35mm)
ø 0.79"(20mm)
1.10"(28mm)
• Definable displaysDefine which measured variables should appear onthe unit display.Ex: User display 1 of 5: current temperature value,peak value of the flow rate, minimum pressure valueand current rpm value.
• Identification of recorded curves or logsThe user can program in a specific ‘company name’and assign a specific station number to the systembeing presently worked on. This specifies which sys-tem each measurement was recorded from.
• Printer OptionsThese options enable print outs (black & white or color)to be done on commercially available printers.Additional details can be obtained from the technicalinformation in this brochure, or simply by contacting one of our distributors.
Fluid Service Catalog
Diagnostics
17
HMG 2020 Portable Data Recorder
The HMG 2020 generally distinguishes between threemeasurement options:
1. Normal measurementPurely a display function where the measured values aredisplayed immediately.Ex: When HMG is measuring with pressure sensors to actas a digital gauge.
2. Curve measurementThe measured values are displayed and simultaneouslystored continuously in the internal memory. The coursesof the curves can be printed out on the printer as soonas measuring has stopped, or transferred to a PC andviewed with the software.
3. Log measurementThe measured values are displayed and can be stored aslog entries in the internal memory. This method of meas-urement is used primarily for long-term measurements(e.g. one week, one month, one year etc.). The log entries canbe printed out on a printer as soon as measuring hasstopped, or transferred to a PC.
The internal memory can store up to 50 different curves andlogs with 250,000 measured values in total.
To optimize your measurements the unit has a wide varietyof additional functions:
• Choice of languageThe user may define which language the unit will displaythe data and parameters.
• Two trigger possibilitiesDefinition of events which start a curve measurement orwhich, on a log measurement, transfer the current measuredvalues to memory.Ex: A curve is to be recorded when the temperatureexceeds 50°C or the system pressure falls below 25 bar.The two triggers can in addition be linked together logically(and/or following one another chronologically), so that data isrecorded exactly at the required moment.
Ordering Information:Standard American Unit: HMG 2020 - 004 - ECall your distributor for details on available options
Description:The HMG 2020 is a portable data recorder for recording pressure, temperature, flow rate, rpm etc. in industrial machinery and systems(e.g. hydraulics, pneumatics). The HMG 2020 can record the measured valuesfrom up to five sensors simultaneously.• 2 inputs for 4 to 20 mA sensors
• 2 inputs for either 4 to 20 mA or 0 to 10 V sensors
• 1 frequency input for digital signals in the range 0.3 to 30,000 Hz
• The measurement range and the unit for each sensor can be set as required(e.g. 0 to 250 bar, -25° to 100°C, 0 to 217 KN). Therefore, the majority of commer-cially available sensors with standard output signals can be connected andevaluated.
• As well as the current measured values, the unit also records the minimumand maximum values, in addition to the differential between two sensors ofthe same type.
Deluxe HMG Diagnostic Kitask your distributor for details
Fluid Service Catalog
Diagnostics
181-877-GO HYDAC
Multiple graphs and whole measurement curve
Zoomed section from overlayOverlay of two curves
HMGWINThe HMGWIN PC program expands the measurement options ofthe portable HMG 2020 data recorder. HMGWIN is compatiblewith Windows 95/98/NT, user friendly, an interactive softwarepackage that allows the user to download the stored data andstudy it in greater detail.
For the user who wishes to store or further evaluate the recordedmeasurement curves and measurement logs, this HMGWIN providesa range of useful functions.
Features:
• Transfer and Storage of curves and logsfrom the HMG 2020 to a PC.
• Viewing of up to 4 different recorded curve orlog measurements simultaneously on the monitor.
• Superimposition of curvesParts of different curves can be superimposed in a new graph, for example to show the wear and tear of a machine (new condi-tion/current condition).
• Straight edge functionAs with a straight edge, you can measure the curves using themouse (exact time and amplitude value). Absolute measured val-ues and also relative measured values (measurement in relation toa set marker) can be displayed.
• Zoom functionUsing the mouse, part of a graph can be framed. The framedarea appears as a new graph, enlarged accordingly.
• Online functionThe portable data recorder measures and transfers the currentmeasured values straight onto the PC. These are then immediatelydisplayed as a graph in realtime (comparable with the function ofan oscilloscope). The graph displayed can be stored if there areany interesting results.
• Portable data recorderSettings can be transferred to the PC and may be stored. Thereverse is also possible, so, for example, settings for takingmeasurements on a particular machine can be fed into theHMG 2020 again and again.
• Data conversionHMGDESK can convert the HMG 2020 data into some otherdata formats. This means, for example, that the recordedcurves can be transferred to many other PC programs (spread-sheets, database, word processing etc.) and further processed.
For complete details on the HMGportable data recorder, and HYDAC’sfull line of pressure, temperature, andflow rate sensors and switches, pleaserequest our Electronics Catalog.Part Number: 02075078
Fluid Service Catalog
Fluid Analysis Service
19
Fluid Analysis Service
HYDAC hydraulic components have an unequaled reputationfor quality, reliability and performance. We built that reputationon a tradition of customer service, and stand behind everyone of our products.Our Fluid Analysis Service follows that same tradition. Weprovide our customers with comprehensive fluid testing anddiagnostic services, with detailed reports that are easy tounderstand.To find out how the HYDAC Fluid Analysis Service can helpyour operation, read on. Then call us to get started.
A Name You TrustOnly one fluid analysis lab lets you put years of HYDACexperience to work for you. That’s because nobody knowshydraulics like HYDAC. So when the health of yourhydraulic system is at stake, choose a partner with morethan 25 years of experience. Contact your HYDAC repre-sentative for more information on our Fluid Analysis Service.
Critical AnalysisFluid is the lifeblood of every hydraulic power system. Tokeep yours running efficiently and effectively, you need toknow what’s in it. What you don’t know can hurt you.The HYDAC Fluid Analysis Service analyzes hydraulic fluidin much the same way a medical lab tests a blood sample.Just as a blood test helps a doctor diagnose health problems,a sample of hydraulic fluid can help us pinpoint sources of contamination and determine whether or not your systemuses adequate filtration.We can help you reduce catastrophic equipment failures,maintain optimum component performance, and identify anysubstandard maintenance practices. Your bottom-line benefitis increased productivity.
Clear BenefitsWe offer testing designed to tell you the most about yourhydraulic fluid. We use sophisticated computer programsand laboratory diagnostic equipment such as an EnergyDispersive X-ray Fluorescence, and an inductively coupledplasma spectrophotometer.After we use this advanced equipment to provide the mostdetailed possible analysis of your hydraulic fluid, we createreports that are always easy to read and understand. By tak-ing the mystery out of fluid analysis, we provide a servicethat clearly explains the benefits of clean fluid.
Comprehensive TestingThe HYDAC Fluid Analysis Service offers a full range oftests specifically designed for the analysis of hydraulic and lubrication system fluid. Our laboratory equipment and testprocedures provide an exact analysis of your hydraulic or oillubricated system, and our drawdown particle isolation procedure ensures accurate results.
Fluid Service Catalog
Fluid Analysis Service
20
Our testing procedures can include:Photomicrography:We scan and photograph a filter patch using an opticalmicroscope to find particle size and type. The scanningprocess verifies the automatic particle count to identify samples needing special preparation. This provides confirmation of automatic counter results, and helps us see what contaminants are in the fluid.
Viscosity (ASTM D445):We use this test to determine the viscosity of your oil.Without proper hydraulic fluid viscosity, your equipment willsuffer. Incorrect viscosity leads to fluid breakdown, inefficientequipment operation, premature system failure, and damageto other components.
Water (ASTM E203):We determine the water content in hydraulic fluid, whichhelps us predict quality and performance characteristics for the fluid and system components. Excess water reduces the viscosity of hydraulic fluid, which increases the likelihood of adverse chemical reactions and degradesequipment performance.
Drawdown Particle Isolation:Using this test, we determine the insoluble contaminates in hydraulic fluids, both insoluble particles and gel-like matter, organics and inorganics. Used in conjunction withphotomicrography, the drawdown patch helps us identify the source and type of fluid contaminants.
Automatic Particle Count (ISO 11500):We use a high-intensity laser light source and a photo sensor to count the number and size of particles in the fluidsample, and then define contaminants according to size distribution and quantities. Automatic particle counting isquick, repeatable and accurate. It provides reliable informationwe can use to check against ISO Standard 4406, whichdefines the relationship between particle counts andhydraulic fluid cleanliness. This lets us determine exactlywhat corrective actions—if any—are needed. The lab is also capable of testing to the new ISO 4406 (1999) standard (4µ, 6µ,14µ).
Spectrometric Analysis (ASTM D 5185):This shows us the concentration of oil-soluble elements, and indicates the additives and trace metal content in thefluids. We use this technique to evaluate the condition of the additives in a fluid rather than its particulate contamination.Used in conjunction with automatic particle counting, it helpsus accurately assess the cleanliness level of the fluid.
Energy Dispersive X-ray Fluorescence (ASTM E 1508):We perform Energy Dispersive X-ray Fluorescence (XRF)analysis on samples with extremely high concentrations ofparticulate contamination. By isolating chemical elements,we pinpoint contaminant types so we can establish their origins, and so you can take corrective action.
1-877-GO HYDAC
17/15/12
20/18/15
23/21/18
Fluid Service Catalog
Fluid Analysis Service
21
Results Target:A results target compares your actual fluid cleanlinessresults and your ideal cleanliness level. If you don’t have atarget level yet, we can use your sample to help you deter-mine what it should be.
Easy-to-Read ReportsWe present your fluid test results in a format that is easy to understand. Results typically include these items:
Trend Information:We evaluate data from your previous two samples alongwith the results of your current sample. This provides a trendanalysis of critical measurements, and shows changes in thefluid over time.
pH (ASTM E 70) represents the strength of acidity inhydraulic fluid, and is usually measured for water-containinghydraulic fluids (water/glycols, invert emulsions). Typicalvalues are 8.5–10.5.
Total Acid Number, or TAN (ASTM D 974), is the amount ofacid and acid-acting material constituents in hydraulic fluid.An increase in TAN indicates oxidation or acid contamina-tion. Some hydraulic fluids exhibit higher acid numbers thanothers. Typical values are 0.1–3.0.
TimeViscosity@ 100˚F
cSt (SUS)
Water %Weight pH1) TAN mg
KOH/gm2)
Test 1Present
45.0 (210) 0.03% 9.4 2.1
Test 2Previous #1
45.5 (212) 0.03% 9.5 2.0
Test 3Previous #2
45.8 (213) 0.03% 9.6 2.1
Time >4µ >6µ >10µ >14µ >21µ >50µCleanliness
Code
Test 1Present
65,120 12,220 5,800 900 125 12.0 23/21/17
Test 2Previous #1
4,100 1,250 700 250 60 5.0 19/17/15
Test 3Previous #2
418 88 39 22 4 1.0 16/14/12
Particle Count Summary
Fluid Results
52
VISCOSITY
WATER 15
On-target
Marginal
Re-sample
Immediate action required 1) pH is for water- containing fluids only.2) TAN is for synthetic fluids only.
Fluid Service Catalog
Fluid Analysis Service
221-877-GO HYDAC
Cleanliness Code Graph:This graph uses the ISO 4406 standard for measuring anddepicting the amount and size of particles per milliliter inhydraulic fluid, shown in a log-log2 graph that charts theamount of particles greater than certain micron sizes permilliliter of fluid.
Recommendations:This section of the report provides you with valuable infor-mation on the cleanliness of your hydraulic system, as wellas tips on maintaining or improving its current condition.
0
10
20
30
40
50
60
70
80
90
100
Ca P S Fe ZnElement
Per
cent
Sample XRF Analysis ResultsWhen a fluid sample shows high particulate contamination, we useEnergy Dispersive X-ray Fluorescence (XRF) analysis to isolate andidentify chemical elements. The results are shown in a graph like this.
Kit Part NumbersFluid Analysis Kit - Premium: 02080533 particle Count, Water, TAN/PH (as applicable), Viscosity,Microscopy, XRF (as applicable), Spectrographic Analysis
Fluid Analysis Kit - Basic: 02080534particle Count, Water, TAN/PH (as applicable), Viscosity.
Fluid Analysis Sampling Pump: 02080531Vacuum pump for extracting oil sample.
Each Fluid Analysis Kit includes the following:• Super clean sample bottle. • Numbered test sample data form (must be filled out com-
pletely to receive the most accurate test results, includingtrend information and E-mail)
• Packaging for mailing sample. • Prepaid fluid analysis services
Range Code
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
100.000
10,000
1,000
100
10
1.0
.1
.01
300,000200,000150,000
50,00040,00030,00020,00015,000
5,0004,0003,0002,0001,500
500400300200150
5040302010
54321.5
.5
.4
.3
.2
.01
1 2 5 10 15 20 25 30 354045 50Paritcle size in micrometers
Num
ber of p
articles greater than size per m
ililiter
20/14/15Cleanliness code
100,000
80,000
40,000
20,000
10,000
5,000
2,500
1,000
500
250
100
80
40
20
10
5
2.5
1.5
1
.5
.15
.08
.04
.02
Fluid Service Catalog23
Fluid Analysis Kits
Description:The static sampler is used to take samples from systemreservoirs. By creating a vacuum in the pre-cleaned samplebottle, the fluid is drawn from the tank at the required level.
For a representative investigation of stray particles in thehydraulic system, dynamic sampling is preferred.
The required sample volume is taken from a pressure lineusually through a testpoint with a minimess flexible hose,after the valve has been flushed.
Applicable Standards:ISO 4021CETOP RP 95 H
FES series Fluid Extraction Set
Quantity Description1 Vacuum pump with gauge1 Aluminum adapter1 2 sampling bottles1 Wash bottle (500 ml)
with removable syringe1 2 Disposable membrane filters
for wash bottle1 2 meter flexible PVC hose1 Telescopic pointer (90 cm)
for accurate mid-tank sampling1 Cable ties (20 pcs.)1 Dynamic sampler1 Minimess flexible hose
(screw/screw)1 Minimess flexible hose
(screw/push-in)1 Sampling bottle (500 ml)1 Case1 Operating Manual1 Contamination Handbook
Items Included in the Kit: Replacement Parts:Quantity Description Part No.
1 Vacuum pump with gauge 3093451 Aluminum adapter 3093491 2 sampling bottles 3093521 Wash bottle (500 ml) 309358
with removable syringe1 2 Disposable membrane filters 309371
for wash bottle1 2 meter flexible PVC hose 3093741 Telescopic pointer (90 cm) 309342
for accurate mid-tank sampling1 Cable ties (20 pcs.) 6275001 Dynamic sampler 3093481 Minimess flexible hose 309350
(screw/screw)1 Minimess flexible hose 309351
(screw/push-in)1 Sampling bottle (500 ml) 3093601 Case 6375611 Operating Manual1 Contamination Handbook 349339
Fluid Service Catalog
Fluid Analysis Kits
241-877-GO HYDAC
Description:The Water Test Kit is used for the quantitative analysis ofwater content in percent by volume of mineral and lubricat-ing oils. Adding two reagents to the contaminated oil caus-es an increase in pressure in the measuring cell. This pres-sure increase can be read off the digital display as watercontent in percent by volume or ppm.
Measurement ranges selectable: 0.02 to 1%; 0 to 10%; 0 to 20% and 200 to 10000 ppm
Test time: only approx. 2 minutes (excluding sample preparation)
Ordering Information:
WTK 200 / -D
WTK series Water Test Kits
Quantity Description1 WTK measuring Cell2 Reagent A, 500 ml bottle50 Reagent B, sachets3 Disposable - 5 ml10 Disposable syringe - 1 ml100 Gloves1 Tweezer1 Scissor1 Measuring cup - 100 ml1 Case1 Operating Instructions
Items Included in the Kit:
Description Part No.Replacement pack consists of: 06030669Reagent A, 500 ml bottleReagent B, sachetsDisposable - 5 mlDisposable syringe - 1 mlGlovesTweezerScissor
Content sufficient for 50 tests
Replacement Parts:
Fluid Service Catalog
Fluid Analysis Kits
25
Description:The Fluid Analysis Set with electric vacuum pump andfiltration unit to laboratory standards is used to producecontamination reports from oil samples. The referencephotographs, found in the contamination handbook,enable a quick evaluation of the contamination levels inthe fluid. A microscope (sold separately - see page 18)can be used to determine the type of particle and there-fore its origin in the hydraulic system. Precision scales(not supplied) can be used to determine the gravimetriccontamination content of the fluid (ISO 4405.)
Ordering Information: FAS K 2: 110 V / 60 Hz electric vacuum pump
FAS series Fluid Analysis Sets
Quantity Description1 Carry case1 Silicone hose (6 feet, 3 x 6 mm Ø)1 Membrane filter disc1 Electric vacuum pump1 Centering ring with strainer1 Vacuum filtration device1 Measuring cylinder (100 ml)1 Sampling jar (500 ml)50 Petri slides1 Wash bottle with membrane filter1 Contamination handbook
Items Included in the Kit
Quantity Description Part No.1 Vacuum filtration device 637345
• top section (250 ml)• funnel attachment• centering ring with strainer• clamp
1 Rubber plug 6373441 Suction flask (1000 ml) 6373431 Silicone Hose (6 feet, 3 x 6 mm Ø) 6389561 Electric vacuum pump (110 V / 60 Hz) 6001270 1 Electric vacuum pump (230 V / 50 Hz) 6373401 Wash bottle (500 ml) 309358
with removable syringe1 Disposable membrane filter 309371
for wash bottle1 100 membrane filter discs 309354
for mineral oil47 mm Ø, 0.8 micron
1 Tweezers (105 mm) 6373411 50 Petri slides (type PD 1504700) 3093771 Measuring cylinder with bushing (100 ml) 6373421 Sampling jar (500 ml) 3093601 Contamination handbook (not shown) 349339
Replacement Parts:
Fluid Service Catalog
Fluid Analysis Kits
261-877-GO HYDAC
MM-S5-P, MM-S5-P-L, & MM-KKE-P-C-LHuygens Eyepiece 10 x MAchromatic Lens 4x, 10x, 20xMagnification 40x, 100x, 200xSupply Voltage 110 V 60 HzMM-S5-P-L & MM-KKE-P-C-L (only)Image Digitation CCD-CameraVideo System PAL color systemResolution horiz. 460 lines
vert. 400 linesImage Processing Video capture unitPC interface LPT 1 portSystem Requirements min. Pentium 100 Mhz.,
Windows 95
Technical Data:Description:This measuring microscope is designed specifically to beused for measuring contamination particles in oil sampleson filter membranes. All models include coarse and finefocusing adjustments, as well as both X and Y directionalslide table adjustments to make focusing and positioningthe subject simple, even at maximum magnification.
There is a rotating lens holder with 3 achromatic objectivelenses with magnifications of 4x, 10x, and 20x. Themicrometer eyepiece provides an additional 10x magnifica-tion resulting in 40x, 100x, and 200x magnifications. Themeasuring scale on the eyepiece has a scale division of 1mm in 100 parts, allowing measurement of particles at allthree magnifications.
These units come with an integrated plug-in light sourcethat provides sufficient illumination, even at maximummagnification.
The optional CCD digital camera attaches to the eyepieceand transfers images to a PC via a USB connection, mak-ing it easy to capture and transmit images from the micro-scope.
Ordering Information:MM-S5-P Standard eyepiece
110 V 60 Hz powered light source
MM-S5-P-L Standard eyepiece110 V 60 Hz powered light sourceCCD camera with LPT-1 port for connection to laptop or PC
MM-KKE-P-C-L Triocular eyepiece110 V 60 Hz external cold light illuminationCCD camera with LPT-1 port for connection to laptop or PC
MM series Measuring Microscopes
Fluid Service Catalog
Portable Filters
27
Applications:The portable OF7 filtration unit is a compact filter/pumpdevice used for transferring and filtering hydraulic fluids. Itcan be used for:
• Removing water from oil• Changing oil in hydraulic systems.• Filling hydraulic systems with filtered oil.• Off-line filtration of hydraulic systems with inadequate
filtering capacity.
Design:A low noise vane pump is directly flanged to the electricalmotor and fixed to an aluminum housing with a foot bracket.The suction line has a cleanable wire screen strainer forpump protection. An AC motor is standard, DC optional.
Product Features:The OF7 is ideal for maintaining construction and agricul-tural machinery, off-highway vehicles and trucks. It isequally useful for servicing a wide variety of industrialequipment.
The standard OF7 incorporates a highly efficientBetamicron® spin-on filter element with a 10 µm absoluterating. Elements with other ratings are available. Other fea-tures of the unit include:
• Relief valve in housing.• Static pressure gauge clogging indicator.• Element easily replaced with strap wrench.
Multi-Pass Filtration EfficiencyRatings for BETAMICRON®
Elements (to ISO 4572):• Beta Ratios for differential pressures above the indicator
trip pressure are shown to demonstrate particle removalat high differential pressures.
• Beta Ratios for many competitive elements drasticallydeteriorate at high differential pressure.
OF7 series Hand Held
BETAMICRON® BN Beta Ratio Data:Betamicron Absolute Terminal
Media Rating ∆P AcrossFilter Element
003 BN ß3 ≥ 200 43 psi
005 BN ß5 ≥ 200 43 psi
010 BN ß10 ≥ 200 43 psi
020 BN ß20 ≥ 200 43 psi
Recommended Fluid Petroleum based oils. Contact HYDAC for other applications.
Nominal Flow 4 GPM / 15 l/min
Maximum Oil Temperature 180°F / 80°C
Viscosity Range 40 to 2300 SUS 5-500 mm2/sec
Max. Operating Pressure 50 PSI / 3.5 bar
Weight 27.5 lb / 12.5 kg
Electrical Motor 110 VAC (0.25 HP / 0.18 KW) or 24 VDC (0.27HP / 0.20KW)
Technical Data:
Fluid Service Catalog
Portable Filters
28
Model Code:OF7 S 10 P 1 K 1 B 10 E
ModelOF7
TypeS = standard
Code10 = standard
SealsP = Nitrile (NBR) (standard)
Pump1 = Vane Pump (standard)
Electric Motor VoltageK = 110 VAC, 60 Hz (standard)U = 24 VDCD = pneumatic motor
Spin-on Filter Element Size1 = Size 0160
Filter Element MaterialB = Betamicron® Low CollapseP = PaperA = Water Removal
Filtration Rating (microns)0305 BN10 Absolute Filtration2010 P -Nominal Filtration10 W Water Removal
Type of Clogging IndicatorE = Pressure Gauge
Dimensions:
1-877-GO HYDAC
ReplacementElement Model Codes
Betamicron®
3 µm 0160MA003BN
5 µm 0160MA005BN
10 µm 0160MA010BN
20 µm 0160MA020BN
Paper
10 µm 0160MA010P
Water Removal
10 µm 0160MA010A
10.87276
14.37365
14.41366
≈21.26≈540
14.37365
Fluid Service Catalog
Portable Filters
29
Applications:The OF5 Filter Carts are used to transfer and filter hydraulicfluids at a rate of 10 or 15 gpm.
Typical applications are to:
• Filter particles and/or water from new oil while filling areservoir.
• Recirculate and filter oil during start-up, when contami-nation is often heaviest.
• Recirculate and filter oil off-line on systems with inade-quate filtering capacity.
• Empty a storage tank or reservoir.
• OF5 Carts are ideal for use in industrial plants and inother demanding applications because of their efficien-cy, capacity, and durability.
Description:Two filter assemblies are staged in series so that all oilflows first through stage 1, then through stage 2 (eachassembly consists of one head and two elements). A key advantage is that the OF5 incorporates four elements toincrease the dirt-holding capacity. Moreover, the OF5 permits the use of different types of elements in eachstage, making it possible to:
A) remove particles in stage 1 and water in stage 2, or
B) remove coarse particles in stage 1 and fine particles instage 2.
Performance:HYDAC is recognized as a leader in the manufacture ofhigh-efficiency, high-capacity, absolute-rated fiberglass filters. Our Betamicron® 3 elements maintain Beta ratios inexcess of 200, meaning that they are able to remove a highpercentage of particles quickly and effectively.
As a result, the cart is capable of:
A) cleaning new oil to a low level of contamination before itis introduced into the system and
B) cleaning oil in a reservoir with a minimum number of circulation passes.
The cart is designed to capture a large quantity of particulatesbecause of the high retention capacity of the filter mediaand use of multiple, extended-length spin-on elements.
Product Features:• Choice of 3, 5, 10, or 20 µm Betamicron 3® absolute-
rated filter elements, all with Beta Ratios ≥ 200 for maximum efficiency
• Availability of water removal elements with capacity of0.45 quarts of water each
• Welded tubular steel frame for durability
• Dirt-tolerant, self-priming vane pump
• Compact design, balanced weight, and large tires foreasy handling
• Color-coded gauge for warning of clogged filter elements
• Spiral-reinforced, clear, 10’ PVC hoses with 20” steel end wands
• 520 µm cleanable strainer before the pump
Dimensions:
OF5 series Wheeled Carts
27.5"
51"
21.5"
Fluid Service Catalog
Portable Filters
30
Technical Data:Fluid Compatibility Mineral oil, including lube & fuel oil. Note: Not allowed for use on water based fluids.
(Contact HYDAC for other applications.)
Motor 1750 rpm, 3/4 HP (series 10), or 2 HP (series 15) 110V Single Phase
Electric Cord 20’ long
Pump Direct drive vane, 10 or 15 gpm, self-priming
Absolute-Rated Filters Extended length spin-on, with 25 psi (1.7 bar) bypass
Water Removal Filters Extended length spin-on, approximately 0.45 quarts of water capacity, with 25 psi (1.7 bar) bypass
Clogging Indicators Color coded static pressure gauge
Strainer Stainless steel, 520 µm
Hoses Spiral-reinforced clear PVC, standard 10’ length, 20” steel wands (Contact HYDAC for applications requiring longer hose lengths)
Dimensions Height 51”Width 21.5”Length 27.5”
Weight of Cart With Elements 123 lbs.
Operating Range Fluid temperature 50ºF - 130ºF (10°C - 54°C)Pressure to 87 psi (6 bar)Viscosity 100 - 500 SUS
1-877-GO HYDAC
Model Code:OF5 - 10 - 03BN - 10A - S
ModelOF5 - Two Stage Filter Cart
Flow Rate10 = 10 gpm15 = 15 gpm
Filtration Rating (micron) (2 Elements Per Stage)
Stage 103BN Betamicron®
05BN Absolute ßx ≥ 20010BN Filtration20BN Rating
Stage 203BN Betamicron®
05BN Absolute ßx ≥ 20010BN Filtration20BN Rating
10A Water Removal ßx ≥
Clogging Indicator
S = Static Pressure Gauge
Replacement Element Model Codes
Betamicron® Paper Water Removal
3 µm 0180MA003BN – –
5 µm 0180MA005BN – –
10 µm 0180MA010BN 0180MA010P 0180MA010A
20 µm 0180MA020BN – –
Fluid Service Catalog
Portable Filters
31
Features: • 18.5 gallon tank capacity
• HYDAC OLF compact offline filter with pump motor unit
• (2) 7.5 foot hoses with wands and holder
• Choice of 2, 5, 10, 20 Dimicron® or 2, 20 Aquamicron®
element with Beta ≥ 1000
• Oil drain
• Optional FCU particle counter connection
• Optional flow counter
Filter Element Dimicron® (2, 5, 10, 20 µm / absolute)Aquamicron® (3, 20 µm / absolute)
Flow Rate 1.3 / 4.9 gpm
Operating Pressure 50.75 psi
Viscosity Range FCC 5/4: 1000-10,000 SUSFCC 5/15: 75-3000 SUS
Fluid Temperature Range 32° to 176° F
Ambient Temperature Range 32° to 104° F
Seals NBR
Safety Type IP 55 (without FCU)
Mass ~133 lbs empty
Tank Volume 18.5 gallons
Length of Hoses 7.5 ft
Length of Electric Cable 33 ft
Technical Data:
Applications:The FCC Filter Carts are used to transfer and filterhydraulic fluids at a rate of 1.3 or 4.9 gpm.
Typical applications are to:
• Filter particles and/or water from new oil whilefilling a reservoir.
• Recirculate and filter oil during start-up, whencontamination is often heaviest.
• Recirculate and filter oil off-line on systems withinadequate filtering capacity.
• Empty a storage tank or reservoir.
• FCC Carts are ideal for use in industrial plants and inother demanding applications because of their efficiency,capacity, and durability.
MP S
FCC series Compact Fluid Carrier
Fluid Service Catalog
Portable Filters
321-877-GO HYDAC
Model Code:FCC - 5/15 - S - L - N5DM002 - BM / K
ModelFCC = Compact Fluid Carrier
Size and Flow Rate5/4 = 1.3 gpm5/15 = 4.9 gpm
Pump TypeS = vane pump
Motor VoltageL60 = 115 V 60 Hz single phaseO60 = 460 V 60 Hz 3 phase
Element Type and Filtration Rating (micron)N5DM 002 = 2 µmN5DM 005 = 5 µmN5DM 010 = 10 µm Dimicron® high efficiency particle removal
N5DM 020 = 20 µm
N5AM 003 = 3 µmN5AM 020 = 20 µm Aquamicron® water removal w/ Dimicron® high efficiency particle removal
Clogging IndicatorBM = Differential indicator - visual with manual reset (model VM2BM.1)C = Differential indicator - electrical (for option FA1 and E - VM2C.0)
Additional OptionsK = Flow counterFA1 = Cut-out when filter is cloggedFCU* = Equipped for FCU connection including holder, measuring points, and switch-over valveE* = Electrical control unit for automatic control using FCU
* For use with the FCU 2000 Series. FCU must be ordered separately.
45.87"1165mm
28.74"730mm
22.68"576mm
Dimensions:
Fluid Service Catalog
Portable Filters
33
FCM series Mobile Fluid Cleaner
Technical Data:Vane Pump Model Gear Pump Model
Max. Flow Rate FCM 60 19 gpmFCM 100 32 gpm
Operating Pressure pmax= 87 psi pmax = 145 psi
Viscosity Range 75 to 2000 SUS 75 to 5000 SUS
Permissible Operating Fluid Mineral Oil
Fluid Temperature 14° to 176°F
Ambient Temperature 14° to 104°F
Seals NBR (optional: Viton)
Safety Type IP 55
Electrical Cable Length 20 ft.
Hose Connections/Hose Length M 52x2 / 2.5 mM 36x2 / 4 m
Weight approx. 175 lbs. (FCM 60) approx. 198 lbs. (FCM 100)
Power Consumption Table:Type FCM 60 FCM 100Vane pump 1.5 kW 2.2 kW
Gear pump 2.2 kW 3.0 kW
P A
M
P A
M
without change-over with change-over
Model Code:FCM - 100 - L - O - 3 B03 - C / S5D5-V
ModelFCM = Mobile Fluid Cleaner
Flow Rate060 = 19 gpm100 = 32 gpm
Pump TypeL = vane pump without change-over (standard)
75 to 2000 SUSF = vane pump with change-over
K = gear pump without change-over75 to 5000 SUS
G = gear pump with change-over
Motor VoltageO = 460 V 60 Hz 3 phase
Filter Size2 = filter size 13003 = filter size 2600
Filter Design (all elements are without bypass)B03 = 3 µmB05 = 5 µm Betamicron® Low CollapseB10 = 10 µmB20 = 20 µm
A40 = 40 µm Aquamicron®
BA03 = 3 µm Betamicron®/Aquamicron® Combination (10 µm only available in size 2)BA10 = 10 µm
Clogging IndicatorB = Visual differential indicator (standard)C = Differential indicator with auto motor cut-out when filter is contaminated (model VM2C.0)
Supplementary DetailsS5 = Suction hose, 16 feet with lanceD5 = Pressure hose, 16 feet with lanceV = FPM (Viton) seals
Dimensions:
Fluid Service Catalog
Portable FIlters
341-877-GO HYDAC
29.53"750mm
49.21"1250mm
26.38"670mm
top ofsize 3(2600)
top ofsize 2(1300)
Fluid Service Catalog
Portable Filters
35
Description: The dewatering and filtration unit FAM is a bypass unitwhich has been specially designed for the conditioning oflubrication and hydraulic fluids. Because of the use of theDimicron® filter element technology with a high contaminationretention capacity the unit works very efficiently.
Advantages: • Separation of 100% free and 90% dissolved water
through vacuum dehydration
• Separation of particles with high contamination retentioncapacity ISO 13/10 attainable
• Removal of 100% free and 100% dissolved gases
• Easy handling and supervision of the process
Applications: • Steel and roll mills
• Pulp and paper plants
• Power generation plants
• Tool machines/Plastic machines
• Oil conditioning
HYDAC FAM vs Other:• Water removal below saturation point
• Static flow through the filter only
• Most efficient particle removal
• Removed water is used to seal the vacuum pump (Vacuum Pump type S, SW only)
• The special vacuum pump concept avoids any dangerouschemical reaction products (Vacuum Pump type S, SW only)
• No corrosion within the vacuum pump
• Serviceable vacuum chamber
• Low operating costs
The contamination of hydraulic fluids with water can eitherbe caused by condensation or by penetration. Variations intemperature of the hydraulic tank lead to condensation.The penetration of water can be caused by defective coolinghoses, defective seals or external leakages into the system.
In lubrication and hydraulic fluids water can occur in twodifferent forms:
• free water (visible)
• dissolved water (not visible)
Aquamicron®, centrifuges and condensation methods normally only separate free water, the FAM separates bothforms of water from the oil. While dewatering the fluid, dissolved gases are also removed. Thereby the lubricatingproperties are improved which extends oil life, reducescomponent wear rates, and eliminates production lossescaused by breakdowns.
FAM series Water & Solid Removal
Fluid Service Catalog
Portable FIlters
361-877-GO HYDAC
Model Code:FAM 15 M 1 O / 1900 015 DM 02 S Z 1
Basic ModelFAM = Fluid Aqua Mobile
Flow Rate10 = 3.3 gpm15 = 5 gpm30 = 10 gpm50 = 16 gpm70 = 23 gpm
Operating FluidM = Mineral OilI = Transformer Oil (heater required)B = Biodegradable OilX = Synthetic & Fire Resistant Oil (please specify exact fluid type)
Type1 = Stationary2 = Mobile
Voltage/FrequencyF = 230 V / 60 Hz / 3Ph+PEO = 460 V / 60 Hz / 3Ph+PEX = Other Voltage
Powerwithout heater with heater1500 = 1500 W (size 10) 4400 = 4400 W (size 10)1900 = 1900 W (size 15) 8650 = 8650 W (size 15)2700 = 2700 W (size 30) 19200 = 19200 W (size 30)3200 = 3200 W (size 50) 21200 = 21200 W (size 50)5100 = 5100 W (size 70) 26100 = 26100 W (size 70)
Filter Size & Number of Elements005 = 1 x N15DMxx (FAM 10 only)015 = 1 x N15DMxx (FAM 15 only)030 = 2 x N15DMxx (FAM 15 and 30 only)045 = 3 x N15DMxx (FAM 15, 30 and 50 only)060 = 4 x N15DMxx (FAM 15, 30 and 50 only)075 = 5 x N15DMxx (FAM 70 only)
Filter MaterialDM = Dimicron®
Absolute Filtration Rating (micron) 02 = 2 µm (DM)10 = 10 µm (DM)20 = 20 µm (DM)30 = 30 µm (DM)
Vacuum Pump Type/SizeD = Rotary vane pump (operating fluid I, X)S = Standard watering / vacuum pumpSW = S with automatic cooling water fill
Measuring EquipmentA = AquaSensorZ = without
Modification Number (latest version always supplied)1
FAM 10 FAM 15 FAM 30 FAM 50 FAM 70Filter Size OLF-5 OLF-15 OLF-30 OLF-45 OLF-70Filter Element N15DMxxx(1x) N15DMxxx(1x) N15DMxxx(2x) N15DMxxx(3x) N15DMxxx(5x)Capacity of Pressure Vessel gal(liters) 1.25(4.75) 5.25(20) 10.5(40) 20.5(78) 26.25(100)Solid Contamination to ISO 4572 lbs(g) 0.45(200) 1.1(500) 2.2(1000) 3.3(1500) 5.5(2500)Electric Clogging Indicator VM 2C.x VM 2C.x VM 2C.x VM 2C.x VM 2C.xBypass Cracking Pressure psi(bar) 29 (2) 29 (2) 29 (2) 29 (2) 29 (2)Pump Type Vane pump Gear pump Gear pump Gear pump Gear pumpFlow rate gpm 3.3 5 10 16 23Maximum Operating Pressure psi(bar) 50.75(3.5) 87(4.5) 87(4.5) 87(4.5) 87(4.5)Viscosity Range (without ) SUS(cst) 75-4000(15-800) 75-2500(15-500) 75-2500(15-500) 75-2500(15-500) 75-2500(15-500)Electrical Cable Length ft (m) 32 (10) 32 (10) 32 (10) 32 (10) 32 (10)Hose Length ft (m) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5)Hose Material NBR NBR NBR NBR NBRInlet - Outlet G1 - G1/2 M52x2-M36x2 M52x2-M36x2 M52x2-M36x2 M52x2-M36x2Seal Material (FPM for operating fluid B, X) NBR NBR NBR NBR NBRDry Weight (lbs.) 665 940 970 1100 1145Fluid Temperature 50°F to 175°F 50°F to 175°F 50°F to 175°F 50°F to 175°F 50°F to 175°FAmbient Temperature 5°F to 105°F 5°F to 105°F 5°F to 105°F 5°F to 105°F 5°F to 105°FMax. Free Water Removal Rate* (gallons/hour) 0.5 0.75 1 1.5 2Attainable water content (ppm) <100 ppm <100 ppm <100 ppm <100 ppm <100 ppm
Technical Data:
For special models, please contact our sales/technical department *See next page for factors that affect water removal rate
Fluid Service Catalog
Portable Filters
37
Saturation Limit of a Hydraulic Oil for Water
free and emulsified water
dissolvedwater
Negative Effects of Water on Oils:It is almost certain that there is water in a hydraulic system. The most frequent causes are: ambient humidity, splashwater, and new oil. Mineral based oils show a faster aging process, if there is water in the oil. This aging process is accel-erated through contamination particles by a catalytic effect. The additives are quickly used up and the lifetime of theoperating fluid is much shorter than that of "dry" oil.
Water in Mineral Oil causes:• Ageing of the fluid
• Fluid deterioration
- Reduced air separating results in: Cavitation
- Increased foaming results in: Cavitation
- Reduced lubrication results in: Vibration & Wear
- Erratic operation results in: Inaccuracy
• Depletes additives
• Clogged filters
Water in Ester Oils causes:• Hydrolysis
• Seal deterioration
• Leakage
FAM Sizing:Sizing of the FAM is normally donethrough periodic measuring of thewater content which will determinethe hourly ingestion of water. Thetypical dewatering speed of theFAM is listed in the technical datatable on page 2. If there is a con-tinuous ingression of water (i.e.condensation) the recommendedflow rate of the FAM can be deter-mined by the the system size (totalgallons.) It should circulate 3 or 4times through the FAM every day.
*Please note that the fluid temperatureshould be a minimum of 20°F warmer thanthe ambient air temperature to enable effi-cient dewatering. An inline heater is avail-able for reclaim applications. Please contactour sales/technical department.
Factors That Affect Water Removal RateFactor Dewatering
(increasing/decreasing) Speed
Water Content
Fluid Temperature*
Detergent Additives
Absolute Pressure in Vacuum Chamber
Humidity
FAM Flow Rate
Ester Oils
Sizing Chart(continuous water ingression)
Tank Volume FAM(gallons) Model
up to 1000 FAM 10
1000 to 2000 FAM 15
2000 to 4000 FAM 30
4000 to 7000 FAM 50
7000 and up FAM 70
tiny water droplets in hydraulic fluid(1 unit equals 10 micron)
Fluid Service Catalog
Portable FIlters
381-877-GO HYDAC
Dimensions are for general information only.
64.96"1650mm
70.47"1790mm
27.56"700mm
24.41"620mm
38.58"980mm
21.65"550mm
69.02"1753mm
67.44"1713mm
M
M
HydraulicApplication
System
M
M
Filter
Level Sensors
Inlet
SolenoidValve
Stop
Stop Stop Outlet
Air Breather
VacuumRegulation
VacuumPump
VacuumChamber
PressureGauge
DrainPump
VacuumPump
Reactor
LevelSwitch
OptionalHeater
DrainPump
SolenoidControlValve
InletOutlet
AirInlet
VacuumAdjustment
Drawing and Dimensions:FAM 10 FAM 15 - 70 (without heater)
Water Extraction Process:(for FAM 15 - 70 without heater only)The operating fluid is drawn from the oil reservoir by the vacuum inthe reactor through the suction strainer and the shut-off valve. Theoil trickles down slowly and from there is fed back into the oil reservoirby the gear pump through the filter. When Dimicron filter elementtechnology is used the unit is especially economical.
Water is removed from the fluid in the reactor. The vacuum presenthas the effect of reducing the boiling point of the water.
The water vapor is released into the atmosphere or the water reservoirthrough the vacuum pump.
Hydraulic Symbol:FAM 10 FAM 15 - 70 without heater
M
M
Fluid Service Catalog
Offline Filtration
39
Technical Data:
Hydraulic Circuit OF5 S:Pumping Out Without Filtration
Off-Line FIltration
Filling With Filtration
Hydraulic Circuit OF5 N:
Dimensions:
Max. Flow Rate 13 gpm
Operating Pressure 65 psi max.
Viscosity Range 75-4000 SUS
Permiss. Operating Fluid Mineral oil (other fluids on request)
Fluid Temperature 14° to 176° F
Ambient Temperature -4° to 104° F
Seals NBR (option FPM)
Safety Type IP 54
Weight approx. 102 lbs empty
7.32"186mm
8.43"214mm
14.65"372mm
15.75"400mm
6.69"170mm
17.52"445mm
35.04"890mm
33014.17"360mm
130024.80"630mm
260042.52"
1080mm
15.75"400mm
M
T A B
M
T A B
M
T A B
M
Filtromat OF5
Fluid Service Catalog
Offline Filtration
401-877-GO HYDAC
Model Code:OF5 S 10 P 6 N 1 B 05 E
ModelOF5 -
TypeS = stationary with change-overN = stationary without change-over
Type Code10 = standard
SealsP = NBRV = FPM (Viton)
Motor Pump UnitCode flow rate max viscosity Electric motor output3 = 10 gpm 1250 SUS 0.75 kW6 = 13 gpm 4000 SUS 1.5 kW
Electric Motor VoltageM = 1 x 230 V - 50 HzN = 3 x 380-420 V - 50 Hz, 3 x 440-480 V - 60 Hz
Filter Size1 = for element size 3302 = for element size 13003 = for element size 2600
Filter MaterialP = paper (P/HC)B = Betamicron® (BN3HC)A = Aquamicron® (BN/AM), (AM)
Filtration Rating (micron) 03 = 3 µm05 = 5 µm Betamicron® Low Collapse10 = 10 µm20 = 20 µm
40 = 40 µm Auquamicron®
A03 = 3 µmA10 = 10 µm Betamicron®/Aquamicron® Combination (10 µm only available in size 2)
10 = 10 µmPaper
20 = 20 µm
Clogging Indicator
E = pressure gauge (standard)B = differential pressure indicator - visualC = differential pressure indicator - electricalD = differential pressure indicator - visual/electrical
Note: Options B, C, D are not available for type “N”
Fluid Service Catalog
Offline Filters
41
Features and Benefits:The OLF series of filters is designed to efficiently and costeffectively filter hydraulic oils, lubricating oils, cleaning fluidsand coolants which are highly contaminated. The filters canbe supplied either as individual filters or as ready-to-installoffline units complete with optional motor and pump units.
• Lower Operating Costs
• Extended Element Service Life
• Cleaner, more efficient systems
Dimicron® Technology:Dimicron® technology, which incorporates membrane filtration and multi-disc construction, sets the OLF apartfrom conventional filters by providing it with exceptionaldirt holding capacity and separation efficiency. Each filterelement is able to capture and hold more than 1 pound ofdirt, meaning that the OLF60, which uses four elements,will hold nearly 5 pounds of dirt. Membrane filtration provides the OLF with a separation efficiency over 99.9%for particles 2 micron and larger (ß2 > 1000) even in a single pass.
Applications:Typical applications include:
• Filling and flushing hydraulic units
• Filtration of fluids for hydraulic systems and test stands
• Filtration of cleaning fluids for parts washing machines
• Filtration of coolants
Dimicron® Element:The synthetic membrane (2µm absolute) provides a high filtration rating while the cellulose filter layer collects andholds the bulk of the dirt load. This combination results inexcellent removal efficiency, even in a single pass, andextremely high dirt holding capacity.
Typical Cleanliness Improvement Using the OLF
Time (minutes)
without OLF with OLFIS
O -
Cla
ss
23/21
21/28
19/16
17/14
15/12
13/10
11/8
9/60 2 4 6 8 10 12 14 16 18 20
OLF series Offline Filtration
QQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQ
CelluloseFilter Layer
SyntheticMembrane
DrainageStructure
SupportTube
Mobile Version Now Available.Consult HYDAC for Details!
Fluid Service Catalog
Offline Filters
421-877-GO HYDAC
Model Code:OLF - 15 / 15 - S - L60 - N15DM002 - E / 12
SeriesOLF = Stationary offline filter with integrated pressure gauge
Size15 = 1 element30 = 2 elements45 = 3 elements60 = 4 elements
Pump Flow Rate (must be less than or equal to size)15 = 5 gpm30 = 10 gpm45 = 15 gpm60 = 20 gpmZ = without pump
Pump TypeS = vane pumpG = gear pumpW = centrifugal pumpZ = Without motor-pump
Motor VoltageL60 = 115V, Single PhaseO60 = 460V, Three PhaseZ = Without motor-pump
Filter ElementN15DM002 = Dimicron® 2 µm AbsoluteN15DM010 = Dimicron® 10µm AbsoluteN15DM020 = Dimicron® 20 µm AbsoluteN15DM030 = Dimicron® 30 µm Absolute
Clogging IndicatorE = Standard Integrated Pressure GaugeC = Differential Pressure Indicator - Electrical (VM2 C.0)F = Pressure Switch - Electrical (VR2 F.0)
Supplementary Details12 = SAE adapters (BSPP connections are standard)V = Viton® Seals (NBR seals are standard)MP = Integrated TestPoint for connection to FCU via Minimess Line
this code entry (15, 30, 45, 60)must be less than or equal to thesize code entry (15, 30, 45, 60)
Dimensions:
17.5"
27"OLF 15
64"OLF 60
52"OLF 45
40"OLF 30
24"
PressureGauge
InletHousingDrain
Outlet
8"
6"
Fluid Service Catalog
Offline Filters
43
Technical Details:Connections (All Female)
Housing Inlet & Outlet: 1 5/16 - 12UN (SAE 16) G1*Pump Inlet:Model Vane Gear CentrifugalOLF-15 1 1/16 -12UN (SAE 12) G3/4 1 1/16 -12UN (SAE 12) G3/4 1 5/16 -12UN (SAE 16) G1OLF-30 1 5/8 -12UN (SAE 20) G1 1/4 1 5/16 -12UN (SAE 16) G1 1 5/16 -12UN (SAE 16) G1OLF-45, 60 1 5/8 -12UN (SAE 20) G1 1/4 1 7/8 -12UN (SAE 24) G1 1/2 1 5/8 -12UN (SAE 20) G11/4
Housing drain standard on all unitsBLACK = SAE connections when using adapters which are supplied standardRED = BSPP connections if supplied adapters are not used
OLF-15 OLF-30 OLF-45 OLF-60Filter Element N15DMxxx(1x) N15DMxxx(2x) N15DMxxx(3x) N15DMxxx(4x)
Contamination Retention Capacity 500g 1000g 1500g 2000g(1.1lbs) (2.2lbs) (3.3lbs) (4.4lbs)
Filter Efficiency ßx > 1000 ßx > 1000 ßx > 1000 ßx > 1000Permissible ∆p Across the Element (psi) 72.5 72.5 72.5 72.5Weight Element (lbs) 6.6 13.2 19.8 26.4Material of Filter Housing Stainless Steel Stainless Steel Stainless Steel Stainless SteelCapacity of Pressure Vessel (gallons) 5.25 10.50 15.75 20.5Max. Operating Pressure Filter Housing (psi) 87 87 87 87Material of Seals-Housing (standard) NBR NBR NBR NBRWeight Housing (lbs) 25 33 53 62Fluid Temperature in °F 15-175 15-175 15-175 15-175
Technical Details for Motor-Pumps Units 5gpm 10gpm 15gpm 20gpmOperating Pressure of the Pump (psi) 65 65 65 65Viscosity Range with Vane Pump (SUS) 75-2500 75-2500 75-2500 75-2500Viscosity Range with Gear Pump (SUS) 75-5000 75-5000 75-5000 75-5000Viscosity Range with Centrifugal Pump (SUS) 5-100 5-100 5-100 5-100Motor Capacity (watts)Vane Pump 370 W 570 W 1500 W 1500WGear Pump 370 W 570 W 1500 W 1500WCentrifugal Pump 370 W 570 W 1500 W 1500WWeight Vane Pump (lbs) 17 30 43 43Weight Gear Pump (lbs) 21 33 49 49Weight Centrifugal Pump (lbs) 33 33 55 55Material of Seals in Pumps (standard) NBR NBR NBR NBRAll details in this brochure are subject to technical modifications.
60
45
30
15
040003000200010000 5000
Viscosity (SUS)
Diff
eren
tial
Pre
ssur
e (p
si)
Differential Pressure at 5 gpm (single element)
N15DM020
N15DM02
N15DM030
N15DM010
Sizing Offline Filtration:The following calculations will help to approximate the attainable system cleanliness level when applying offline filtration.
Step 1: Select the approximate contamination ingression rate fromthe chart below. HYDAC quantitative investigations have yielded the following approximate figures.
Step 2: Make the correction required for offline filtration.The contamination input selected above must be multiplied by the factor:
Main System Flow Rate / Desired Offline Flow Rate
Note: Main system flow rate must be corrected for cycle time. For example, if the flow rate is 500 gpm, but only runs for20% of the system cycle, the main system flow rate would be 100 gpm. (500 gpm X 20%)
This yields the expression:
Contamination Factor = Contamination Input (µg/gal) x Main System Flow Rate (gpm)
Desired Offline Flow Rate (gpm)
Calculate the contamination factor using this expression.
Step 3: Determine the attainable cleanliness level. Locate the calculated contamination factor on the y-axis of the attachedgraph. Go to the right to find the intersection point on the curve corresponding to the desired absolute filter micron rating.Read the resulting attainable cleanliness level on the x-axis. (In case of dynamic flow through the offline filter, the attainablecleanliness level will be 2 to 3 times worse than indicated by the graph.)
Offline Filtration Sizing ExampleType of System: Heavy industrial press
Surroundings: Normal
Main System Flow Rate: 150 GPM
Desired Offline Flow Rate: 16 GPM (OLF 60)
Step 1: Using this criterion select the approximate contamination ingression rate from the chart above.
This yields a contamination input of 18 µg/gal based on a heavy industrial press with normal surroundings.
Step 2: Make the correction required for offline filtration.
Contamination Factor = 18 µg/gal x 150 gpm / 20 gpm = 135
Step 3: Determine the approximate attainable cleanliness level for each micron rating using the attached graph. If theattainable cleanliness level is not acceptable, the desired offline flow rate should be increased. The approximate attainablelevels for this example are as follows.
2µm - ISO 17/15/12
20µm - Between ISO 20/18/15 and ISO 21/19/16
Fluid Service Catalog
Offline Filters
441-877-GO HYDAC
CONTAMINATION INGRESSION (µg/gal)
TYPE OF SYSTEM SURROUNDINGS
CLEAN NORMAL POLLUTED
Closed circuit 1 3 5
Injection molding machine 3 6 9
Standard hydraulic system 6 9 12
Lubrication system 8 11 14
Mobile equipment 10 13 16
Heavy industrial press 14 18 22
Flushing test equipment 42 60 7820
20
20
20
20
10
10
10
10
10
3
1000
100
10
1
0.1
0.0112/10/7
13/11/814/12/9
15/13/1016/14/11
17/15/1218/16/13
19/17/1420/18/15
21/19/1622/20/17
3
3
3
5
5
2
2
25
Con
tam
inat
ion
Fact
or (
g/ga
l)
Maximum Attainable Cleanliness Level (ISO)
20
10
3
2 2 micron
5
20 micron
10 micron
3 micron
5 micron
LEGEND
Fluid Service Catalog
Fluid Service
45
Operating RangeViscosity: (see pressure drop curves) to 700 SUS (OLF-5) / to 3000 SUS (OLF-5/15) / to 10,000 SUS (OLF-5/4)Operating Pressure: 45 PSI (3 bar) maxSuction Pressure: 11” Hg (-0.4 to 6 bar) maxInlet Pressure (Model with flow control valve): 145 PSI (10 bar) min / 725 PSI (50 bar) maxFluid Temperature: 32 to 175° F (0 to 80° C)Ambient Temperature: -4 to 104° F (-20 to 40° C)Seals: NBR (standard)Maximum Flow Rate: OLF-5 = 1.6 GPM / OLF-5/15 = 4.9 GPM / OLF-5/4 = 1.3 GPM
Fluids Standard Mineral Oils / Water/Oil based fluids (Minimum 40% Oil in Fluid)Consult Factory for Other Fluids
ElementsMedia: Dimicron - 2µm, 20µm / Water Removal - 2µm, 20µmNumber required: OLF-5, 5/15, and 5/4 = 1Dirt Holding Capacity (∆P = 36 psi [2.5 bar]): 200g ISO MTD (N5DM...) / 185g ISO MTD (N5AM...)Water Retention (∆P = 36 psi [2.5 bar]): Approximately 0.5 quarts (0.5 liters)Beta Ratio: ßx > 1000 (absolute value)Maximum ∆P: 45 PSI (3 bar)
Connections (All Female)OLF-5 with motor/pump: Inlet & Outlet: 3/4 - 16UNF (SAE 8) (BSPP G1/2)OLF-5/15 & 5/4: Inlet & Outlet: 1 5/16-12UN (SAE 16) (BSPP G1)OLF-5 without motor/pump: Inlet: 9/16-18UNF (SAE 6) (BSPP G3/8)
Outlet: 3/4-16UNF (SAE 8) (BSPP G1/2)Weight OLF-5-S (15.5 lbs. (7.0 kg) / OLF-5-E (5.5 lbs. (2.5 kg) / OLF-5/15 (24.3 lbs. (11 kg)
OLF-5/4 (24.3 lbs. (11 kg)
Technical Data:
OLF series Offline Filtration
Features:The OLF Compact filter is designed to be used offline toefficiently and cost effectively filter standard hydraulic oilswhich are highly contaminated. The OLF Compact isspecifically designed to be used on hydraulic systems witha reservoir volume of up to 1000 gallons. Please see sizingcalculation on back page. The standard filters can be suppliedas ready to install offline units complete with motor andpump units as shown or as individual filters.
Applications:Typical applications include:
• Injection molding machinery• Machine tools• Gear boxes• Mobile equipment• Filtration of fluids for intermittently operated hydraulic
systems and test stands
Benefits:• Lower operating costs• Extended element service life• Extended fluid life• Cleaner, more efficient systems• Incinerable elements• Easy installation
Housing drain standard on all unitsBlack = SAE connections when using adapters which are supplied as standardRed = BSPP connections if supplied adapters are not used
Fluid Service Catalog
Offline Filters
461-877-GO HYDAC
Typical Cleanliness Improvement Using the OLF
Time (minutes)
without OLF with OLF
ISO
- C
lass
23/21
21/28
19/16
17/14
15/12
13/10
11/8
9/60 2 4 6 8 10 12 14 16 18 20
Model Code:OLF-5 - S - 120 - K - N5DM002 - E / 12
SeriesOLF-5 = Series 5 (1.6 gpm) OLF-5/15 = Series 15 (4.9 gpm)OLF-5/4 = Series 15 (1.3 gpm)
Pump TypeS = Vane Pump* (standard)E = Flow Control Valve (series 5 only)M = Mobile
Power Consumption120 = 120W for all OLF 5200 = 200W for all 12VDC and 24VDC370 = 370W for all Series 5/15 & 5/4Z = Without motor-pump unit (series 5 only)
VoltageT = 12VDCU = 24VDC K = 115V single phaseM = 220V single phase N = 220/440V 3 phaseZ = Without motor-pump unit
ElementN5DM002 = 2 micronN5DM020 = 20 micronN5AM002 = 2 micron with water removalN5AM020 = 20 micron with water removalM180B20 = 20 micron spin-on (series 5/4 only)
Clogging IndicatorE = Standard gauge (series 5 only)F = Static electrical switch VMF2F.0 (series 5 only)BM = Differential visual VM2BM.1 (series 5/15 & 5/4 only)C = Differential electrical VM2C.0 (series 5/15 & 5/4 only)D = Differential electrical/visual VM2D.0/L... (series 5/15 & 5/4 only)
Mechanical Connections12 = SAE Connections (standard)
Supplementary DetailsL24 = Lamp for 24 voltsL48 = Lamp for 48 volts D-Type CloggingL115 = Lamp for 115 volts Indicator OnlyL230 = Lamp for 230 volts
Consult Factory for special optionsNot all combinations available
*Choose “S” for model without motor-pump and without flow control valve.
ReplacementElement Model Codes
Betamicron®
2 µm N5DM002
20 µm N5DM020 or 180MA020BN (OLF-5/4 only)
Water Removal2 µm N5AM002
20 µm N5AM020
0
2.5
10bar
11.890"(302)
9.961"(253)
.354"(9)
.394"(10)
538
413
2
6
7
5
8
2.913"(74) 1.457"
(37)
min 2.362" (60)
6.614"(168)
3.189"(81)
4.291"(109)
7.362"(187)
6.299"(160)
Fluid Service Catalog
Offline Filters
47
P
S
3.5 bar
M
P
S
M
VA
P
S
po =3.5 bar
Dimensions:
12.598"(320)
605
2
65
Ø 5.67"(Ø 144) 5.35"
(136)4.410"(112) Ø 0.276"
(Ø 7)
2.795"(71)
370-M370-K
8.31"(211)Max.
1
3
8
7
3.543"(90)
4.409"(112)
4.528"(115)
4
N5...
0
2.5
10bar
12.205"(310)
9.961"(253)
.354"(9)
.394"(10)
13.228"(336)
4
132
6
7˚
5
2.913"(74)
1.457"(37)
7.362"(187)
ca. 9.843"(250)
6.299"(160)
6.614"(168)
3.189"(81)
7.480"(109)
OLF-5-S-...
OLF-5/4-S-... and OLF-5/15-S...
OLF-5-E-...
12.76"(324)
016019.88"(505)
01606.89"(175)
018023.94"(608)
018011.06"(281)
2
Ø 5.512"(Ø 140) 5"
(127)4.410"(112) Ø 0.276"
(Ø 7)
2.795"(71)
7.283"(185)
4.488"(114)
1
3
8
7
7
3.543"(90)
4.409"(112)
4.528"(115)
(0160)
(0180)
OLF-5/4-SP-...
Key1 = Inlet 5 = Filter Bowl2 = Clogging Indicator 6 = Drain3 = Outlet 7 = Filter Element4 = Clamp 8 = Electric MotorDimensions are in inches (mm)
Fluid Service Catalog
Offline Filters
481-877-GO HYDAC
Differential Pressure:
OLF-5-TAK:
OLF-5/4-...
OLF-5
Q (
gpm
)
Viscosity (SUS)15 200 7000
4
00 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 47.5 5042.5 45
1.0
2.0
3.0
4.0
5.0
6.0
Bar
l/min
SRV flow control valve curve Application
Tank capacity to approx. 200 gallons
Tank capacity to approx. 525 gallons
N5DM002
Viscosity (SUS)
Diff
eren
tial P
ress
ure
(PS
I)
45.04.9 gpm
1.66 gpm
1.36 gpm
37.5
30.0
22.5
15.0
7.5
0.00 2500 5000 7500 10,000
N5DM020
Viscosity (SUS)
Diff
eren
tial P
ress
ure
(PS
I)
4.9 gpm
1.66 gpm
1.36 gpm
37.5
30.0
22.5
15.0
7.5
0.00 2500 5000 7500 10,000
breather filter
ventalation
S
R
adapter
return hose
suction hose
Description:Use the OLF-5-TAK tank connection kit 2.0 toquickly mount bypass filter units on hydraulicinstallations. This component can be mountedon installations with ventilation filter whoseconnections conform to DIN 24557/T2.
Ordering Information:Model Code: OLF-5-TAK Part No.: 03039235
Fluid Service Catalog
Replacement Elements
49
Be sure to order the correct number of elements:OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4
*Cartridge element can not be used with OLF 5/4-SP**Spin-on element for OLF 5/4-SP only
Model Code Micron Rating Media Type Part No.N15DM002 2 Dimicron® 01251590N15DM010 10 Dimicron® 03115180N15DM020 20 Dimicron® 00349576N15DM030 30 Dimicron® 03048790
OLF Offline Filters
FCM & Filtromat OF5
Model Code Micron Rating Media Type Part No.N5DM002* 2 Dimicron® 00349494N5DM020* 20 Dimicron® 03023508N5AM002* 2 Aquamicron® 00349677N5AM020* 20 Aquamicron® 03040345
180MA020BN** 20 Betamicron® 02059441
OLF Compact Offline Filters & FCC Filter Cart
1300R BN3HC 003 KB
Size0330R = size 330 return line element (Filtromat OF5 only)1300R = size 1300 return line element2600R = size 2600 return line element
Media TypeBN3HC = Betamicron®
AM = Aquamicron®
BN/AM = Betamicron®/Aquamicron® CombinationP/HC = Paper
Micron Rating003 = 3 µm005 = 5 µm010 = 10 µm020 = 20 µm040 = 40 µm
Bypass Valve(omit) = 43 psidKB = without bypassB6 = 87 psid
NOTE: not all combinations are available.
Fluid Service Catalog
Replacement Elements
501-877-GO HYDAC
HYDAC offers a complete range of interchange elementsfor all major manufacturers. To quickly and easily searchfor an interchange for any manufacturer, please visit:
BN/AM filter elements are specifically designed to absorb water and achieve absolute filtration ofsolid particles from mineral oils, HFD-R oils, and rapidly biodegradable oils. A super absorberreacts with the water present in the fluid and expands to form a gel from which the water can nolonger be extracted even by increasing the system pressure. These filter elements do not removedissolved water below the saturation level of the hydraulic medium. Solid particle filtration (3 µm,10 µm absolute) is achieved due to the Betamicron® filter construction.For complete details please contact your HYDAC distributor.
Aquamicron® filter elements are specially designed to separate water from mineral oils. They areonly supplied in the dimensions of HYDAC return line filter elements from size 330 and larger.This means that they can be installed in all HYDAC filter housings from size 330 which are fittedwith return line filter elements.The increasing pressure loss in a filter element which is being saturated with water indicates, bymeans of standard clogging indicators, that it is time to change the element. When theAquamicron® technique is employed, particle contaminants are also separated from the hydraulicmedium as a by-product. This means that the Aquamicron® element doubles as a safety filter.The "filtration rating" is 40 µm absolute (ß40 ≥ 100 to ∆p = 3 bar).In order to guarantee the greatest efficiency, it is recommended that these elements be installed inan off-line recirculation loop configuration.For complete details please contact your HYDAC distributor.
Interchange Elements
Aquamicron® (AM)
Betamicron® / Aquamicron® (BN/AM)
0180MA BN 003
Size0160MA = size 160 spin-on element (OF7 only)0180MA = size 180 spin-on element (OF5-10 & 15 only)
Media TypeBN = Betamicron®
A = Aquamicron®
P = Paper
Micron Rating003 = 3 µm005 = 5 µm010 = 10 µm020 = 20 µm025 = 25 µm
NOTE: not all combinations are available.Refer to product model code charts to seewhich combinations are available for each.
Portable Filtration Units
Fluid Service Catalog
Other Products
51
HYDAC’s Hydraulic Division offers a line of air-cooled andwater-cooled conditioning units for both mobile and industrialapplications. Highly engineered heat exchangers providethese units with exceptional efficiency in a compact design.
Air-Cooled industrial units use AC fans, while the mobile unitsuse DC, or hydraulic drive fans. Industrial units are availablewith pump & filter to provide a complete conditioning unit.
Call HYDAC’s Hydraulic Division for more information:
630-545-0800
HYDAC has over 35 years of experience developing filtrationproducts. Extensive field research and an application drivendesign philosophy have lead to a complete line of filters.Our line ranges from small manifold cartridges (circuitprotectors) to huge return-line housings that handle flowsup to 3900 gpm.
Call HYDAC’s HYCON Division for more information:
877-464-9322
Reservior accessories produced by HYDAC’s HYCONDivision include breathers, filler breathers, fluid level indicatorsand suction strainers. Breathers prevent the ingression ofcontamination which is more 10 times more efficient thanhaving to remove it after entry to the system. Filler basketsprevent large contamination from entering the tank duringfilling. Suction strainers protect the pump from contaminationthat does enter the tank. Fluid level indicators which areavailable with electric level switches protect against low oillevels which could result in inefficient system operation andcomponent damage.
Call HYDAC’s HYCON Division for more information:
877-464-9322
New Online Selector!
This new software is driven by a database that is constantly updated,so you know that you are viewing the most current data available. Itallows users to quickly perform searches by model code OR manu-facturer, and allows for the use of wildcards. This program alsoallows users to easily inquire about elements that are not listed.
Upgrade All Your Elements Today!Let HYDAC be your single source for all of your hydraulic and lube oil filter elements.Simplify purchasing and inventory while experiencing these benefits:
• High Dirt-Holding Capacities• Low Pressure Drops• High Efficiency Absolute Ratings• Great Cost to Value Ratio• Supported Mesh Packs• Global Availability
Fluid Service Catalog1-877-GO HYDAC
Bladder, Piston, & Diaphragm Types; Pulsation Dampeners & Shock Absorbers;Safety & Shut-off Blocks; Charging & Gauging Units; Mounting Components & Accessories
Hydraulic Oil; Lube Oil; Fuel & Fuel Oil; Water; Process;High Pressure; Return Line; Suction; Strainers; Inline; Manifold-mount; Modular Stacking;In-tank; Inside Tank; Circuit Protectors; Spin-on; Backflush; Selectable Duplex; Clogging Indicators;Wide Variety of Elements Including Interchanges for All Major Brands; Private Labeling for OEM’s
Offline & Portable Filters; Online & Portable Realtime Particle Counters; Water Sensors;Fluid Sampling Kits; Fluid Analysis Kits; Vacuum Dehydration Water Removal Units
High & Low Pressure Ball Valves; Flow, Needle, & Check Valves;Hydraulic/Pneumatic Actuators; Custom Valve Design
Hose, Tube, & Pipe Clamps; Cushion Clamps; Band Straps;U-bolts; Fixed Cylinder Clamps; Custom Clamping Solutions
TestPoints & Flexible Test Hoses; Fluid Level Indicators; Gauge Isolators;Suction Strainers; Breathers; Filler/Breathers; Desiccant Breathers
Pressure & Temperature Transducers & Switches; Flow Rate Meters;Current Probes; Digital Displays; Portable Data Recorders
Air-Cooled & Water-Cooled Models; Cooler, Pump/Filter, & Pump/Filter/Cooler Units;AC Industrial Models; DC & Hydraulic Drive Mobile Models
High Pressure & Compact Power Units;Standard & Custom Integrated Control Units
Pressure Controls — Reducing & Relieving Valves; Proportional Pressure & Flow Control Valves;Check Valves; Flow Controls; Load Controls — Counterbalance & Pilot-Op. Check Valves;Custom Manifold Design & Manufacturing; Solenoid Directional Valves — Poppet & Spool Types;5000 psi, up to 40 GPM; Inline Mounting Bodies
Central Valve Blocks; Suspension Control; Steering Control;Power Attachment Controls; Design & Application Assistance
© Copyright 2003, 2005 HYDAC TECHNOLOGY CORPORATION • HYCON Division2260 City Line Road • Bethlehem, PA 18017Phone: (610) 266-0100 • Fax: (610) 231-0445
Brochure - Fluid Service Products Catalog #02075860 / 06.05
The Single Source for Hydraulic Components