Fluid Service Products Fluid Condition Monitoring & Contamination Control

Transcript of Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters,...

Page 1: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service ProductsFluid Condition Monitoring & Contamination Control

Page 2: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog2

Pulp and PaperLube oil circuits and hydraulic systems found inpaper mills benefit greatly from the implementationof HYDAC fluid service products as well asHYDAC filters, coolers, accumulators, and otherproducts. As with all industrial hydraulics and lubeoil circuits, it is crucial to keep the levels of bothwater and solid contamination to a minimum.

About HYDACHYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributorsworldwide and more than 40 wholly owned branches. HYDAC has been active in the field of fluid conditionmonitoring and filtration for more than 30 years and is a global leader in the design and production of suchproducts. The experience of our staff, and distributors become the customer’s asset when working with HYDAC.Controlling contamination is crucial to fluid power systems — Let the experts at HYDAC help!

Power GenerationHYDAC Fluid Service Products play a key role in providing system maintenance and monitoring inpower generation plants. By implementing acomprehensive filtration & fluid condition monitoringprogram these systems will operate more efficiently,and downtime and component failure will be reduced.

Mobile MarketOur rugged, portable contamination monitors alloweasy field use to check oil cleanliness. OEM’s useour products to verify and document that equipmentis leaving the factory with clean oil. Our portable fil-tration units are ideal for correcting extreme waterand contamination problems caused by the severeenvironments in which these machines operate.

Steel & Heavy IndustryMaintaining clean hydraulic systems in steel millsand other heavy industrial plants is very important.The use of HYDAC fluid service products will helpkeep these operations running smoothly and effi-ciently, by reducing costly system and componentfailures. Investment in these products can easily bejustified by the resulting cost savings.

Offshore Shipbuilding and Marine TechnologyHYDAC offline filtration units protect the hydraulicsystems of cranes, blow-out preventors, motioncompensators, thruster and ballast controls, and risertensioning systems on offshore drilling rigs. Our compact offline filter is available in an explosionproof (intrinsically safe) version, making it ideal for usein any industry where volatile gasses may be present.

Plastics Injection molding and blow molding machines, areall perfect candidates for the supplemental filtrationloops that HYDAC can help you install. Whenmachine downtime is a problem, HYDAC’s fluidservice product are the solution!

HYDAC ProductsOur product range includes portable and online contaminationmonitors and water content sensors, as well as portable andpermanent offline filters. For more critical applications, we offerin-depth analysis kits which return detailed reports about thecondition of a system’s fluid.

HYDAC Customer ServiceOur internal staff and worldwide distribution network take care ofthe important matter of customer service. HYDAC values highstandards, professional ethics, and mutual respect in all transactionswith customers, vendors, and employees. We invest in our relationshipsby providing expertise, quality, dependability, and accessibility tofoster growth and a sense of partnership. Our customer servicerepresentatives are committed to serving the customers’ needs.

HYDAC QualityHYDAC stands for quality and customer satisfaction. This quality isthe result of constant research and development combined with 35years of global application experience and know-how. Our productsare designed to be reliable and cost-effective solutions for monitoringand maintaining hydraulic and lube oil cleanliness.

Page 3: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Service

1-877-GO HYDAC

IntroductionGeneral Introduction .............................1Cost Savings Calculations ....................2ISO Cleanliness Levels .........................3

Offline FiltersOF5 [Filtromat] ....................................39OLF .....................................................41OLF compact ......................................45

Water Content ControlNegative Effects of Water ...................37AS series [water content sensor] ........13AS1000 series [water sensor] .............15FAM [water & solid removal] ...............35WTK [water test kit].............................24Aquamicron® Elements .......................50

Replacement ElementsReplacement Elements .......................49Aquamicron® .......................................50Betamicron® ........................................50Betafit Interchange Elements..............50

Other Products from HYDACCoolers................................................51Filters...................................................51Reservoir Accessories ........................51Complete Line Card ..............back cover

Portable FiltersOF7 [hand-held] ..................................27OF5 [wheeled carts] ............................29FCC [compact fluid carrier].................31FCM [mobile fluid cleaner] ..................33FAM [water & solid removal] ...............35

Fluid Analysis Fluid Analysis Service .........................19FES [fluid sampling kit] .......................23WTK [water test kit].............................24FAS [fluid analysis kit] .........................25Measuring Microscopes......................26

Contamination Monitors & DiagnosticsFCU series [portable particle counter] ..5CS series [permanent particle counter] 9CS1000 series [contamination sensor]11AS series [water content sensor] ........13AS1000 series [water sensor] .............15HMG series [portable data recorder] ..17

All information is subject to change without notice.

Page 4: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Service

1

IntroductionContamination and degraded fluid quality cause inefficientoperation, component wear, and eventually failures in allhydraulic and lubrication systems. The products in thiscatalog are the tools that are needed to prevent suchoccurances. HYDAC Recommends a three step approachto controlling contamination in any system:

• Assess

• Recommend & Implement

• Monitor & Maintain

AssessStart by gathering complete information on the system.This includes:• a list of the most critical components• the mfg’s recommended ISO class for each component• the type of oil being used• flow rate & operating pressure• fluid temperature & ambient temperature• system’s operational characteristics• details on all current filters in the system• solid contamination levels (ISO class)• water content levels• details on all current filters in the system

Recommend & ImplementNext, specify your recommendations for upgradingthe current filtration, and adding the appropriatesupplementary filtration:• pressure filters• return line filters• manifold cartridge/circuit protector filters• element micron rating• reservoir breathers or filler breathers• strainer baskets• addition of offline filtration loop• use of portable filters for filling/temporary offline loops• sufficient water removal protection• proper fluid monitoring devices

Monitor & MaintainFinally, use reliable methods for continuous monitoring ofthe fluid conditions including:• solid contamination• water content• additive depletion• element clogging• periodic detailed analysis of actual fluid samples• portable filters for correcting unacceptable levels

The FCU portable particle counter

OLF 15 installation

Microscope with camera attached to a monitor

Page 5: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Service

21-877-GO HYDAC

Savings Realized by ProperContamination ControlThe money invested in contamination control can easily bejustified when the resulting machine availability increasessignificantly. The graph below illustrates that there is arange in which this investment really pays off.

Savings Calculation ExampleThis example demonstrates how to calculate the potentialsavings that will be realized by implementing a proper fluidservice program.

Example Your Data

Number of Machines 50 a ________

Operating Hours per year 5,000 b ________

Current Availability 92% c ________

Downtime Costs per hour $60 d ________

Total Downtime Costs $1,200,000 e ________ (a x b x (100 - c) x d)100

Downtime costs due to:

- mechanical/electrical failures (65%) $780,000 f ________ (e x .65)

- hydraulic failures (35%) of which: $420,000 g ________ (e x .35)

- 70% is due to the fluid $294,000 h ________ (g x .70)

- 30% is caused by other faults $126,000 i ________ (g x .30)

HYDAC Fluid Service can return 90%of the fluid related downtime costs $264,600 j ________ (h x .90)

Machine Availibilty in %

Solid

Part

icle

Con

ten

t /

mg

Economic Range

Try our automated savings calculator at:

click products > fluid service products

Page 6: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Example: larger than 4µm = 22,340larger than 6µm = 1,950larger than 14µm = 43

ISO Code = 22 / 18 / 13

13

18

282726252423222120191817161514131211109876543210

2,500,0001,300,000

640,000320,000160,000

80,00040,00020,00010,000

5,0002,5001,300

640320160

80402010

52.51.3

0.640.320.160.080.040.020.010.00

> 4 µm > 6 µm > 14 µm

22

Fluid Service Catalog

ISO Cleanliness Levels

3

How the ISO 4406 Code works:Cleanliness levels are defined by three numbers divided byslashes (/.) These numbers correspond to 4, 6, and 14micron, in that order. Each number refers to an ISO RangeCode, which is determined by the number of particles forthat size (4,6, & 14µm) and larger present in 1 ml of fluid.Each range is double the range below. Refer to the chartbelow to see the actual ranges.

Achieving the appropriate cleanliness level in a system:The only way to achieve and maintain the appropriate cleanliness level in a hydraulic or lubrication system,is to implement a comprehensive filtration program.

HYDAC offers all of the products that are needed to do just that! - They include:

Solid Contamination:• pressure filters

• return line filters

• offline filtration loops

• oil transfer units for precleaning of new oil

• portable and online contamination monitors

• reservoir breathers and filler/breathers

Water Content:• water content sensors

• reservoir breathers with silica gel desiccant

• vacuum dehydration water removal units

• water removal elements

Fluid Analysis:• bottle sampling kits

• complete analysis kits

14/12/9

17/15/12

20/18/15

23/21/18

Page 7: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

ISO Cleanliness Levels

4

TISOarget

Levels

ISO

Low/Medium PressureUnder 2000 psi(moderate conditions)

High Pressure2000 to 2999 psi(or low/medium with severe conditions1)

Very High Pressure3000 psi and over(or high pressure with severe conditions1)

TargetLevels

TISOarget

LevelsMicronRatings

MicronRatings

MicronRatings

PumpsFixed Gear or Fixed Vane 20/18/15 20 19/17/14 10 18/16/13 5

Fixed Piston 19/17/14 10 18/16/13 5 17/15/12 3Variable Vane 18/16/13 5 17/15/12 3 not applicable not applicable

Variable Piston 18/16/13 5 17/15/12 3 16/14/11 3(2

ValvesCheck Valve 20/18/15 20 20/18/15 20 19/17/14 10

Directional (solenoid) 20/18/15 20 19/17/14 10 18/16/13 5Standard Flow Control 20/18/15 20 19/17/14 10 18/16/13 5

Cartridge Valve 19/17/14 10 18/16/13 5 17/15/12 3Proportional Valve 17/15/12 3 17/15/12 3 16/14/11 3(2

Servo Valve 16/14/11 3(2 16/14/11 3(2 15/13/10 3(2

ActuatorsCylinders, Vane

20/18/15 20 19/17/14 10 18/16/13 5Motors, Gear MotorsPiston Motors, 19/17/14 10 18/16/13 5 17/15/12 3

Swash Plate MotorsHydrostatic Drives 16/15/12 3 16/14/11 3(2 15/13/10 3(2

Test Stands 15/13/10 3(2 15/13/10 3(2 15/13/10 3(2

BearingsJournal Bearings 17/15/12 3 not applicable not applicable not applicable not applicable

Industrial Gearboxes 17/15/12 3 not applicable not applicable not applicable not applicable

Ball Bearings 15/13/10 3(2 not applicable not applicable not applicable not applicable

Roller Bearings 16/14/11 3(2 not applicable not applicable not applicable not applicable

1-877-GO HYDAC

Finding the cleanliness level required by a system:1. Starting at the left hand column, select the most sensitive component used in the system.

2. Move to the right to the column that describes the system pressure and conditions.

3. Here you will find the recommended ISO class level, and recommended element micron rating.

1. Severe conditions may include high flow surges, pressure spikes, frequent cold starts, extremely heavy duty use, or the presence of water2. Two or more system filters of the recommended rating may be required to achieve and maintain the desired Target Cleanliness Level.

FREE Poster!The information on these two pages is also available on our ISO Cleanliness Guidelines poster.Visit our web site to request your FREE copy.

Page 8: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

5

Description:The FCU 2000 Series Fluid Control Unit is the second generation of diagnostic equipment for measuring and controlling contamination in hydraulic and lubrication systems. These Units are portable, which makes them ideal for use on multiple machines in a plant, or in-the-fielduse. The rugged construction incorporates a folding handlewhich also serves as a prop stand for optimal viewing.

Online Measurement:A key advantage of the FCU is that it allows the user tomeasure changes in contamination instantaneously as theyoccur. The unit continuously detects solid particles and displays the results in cleanliness classes according to ISO4406 (1992 or 1999), SAE AS 4059 or NAS 1638 standards.

Tank Extraction/Bottle Sampling:The FCU 2000-4 model is equipped with a specific suctioninlet and an integrated pump for reservoir and bottle extraction,in addition to the standard online measurement capability.

Comprehensive Reporting:Measurements are automatically stored in memory and canbe used to print tabular and graphic reports in a wide varietyof formats. Although extensive functions for data recordingand documentation are available, clear built-in menus makeit easy for a user to develop highly informative reports withminimal training.

PC Capability:For many applications, the built-in printer will produce thenecessary reports. In addition, data can be transmitted to aPC via an RS232C interface, providing the user with flexibilityin analysis with the supplied CoCos light software package,or with standard packages like MS-EXCEL.

Contamination Control:By means of control software, the user can program theFCU to activate an auxiliary filtration unit through built-inrelays when contamination reaches a specified maximumlevel. This makes it possible to control system cleanlinessreliably and automatically.

The FCU also can be programmed to de-activate an off-lineunit when contamination reaches a preset target level, anespecially useful feature in flushing operations.

Applications:The versatility and simplicity of the FCU 2000 Series isadvantageous in various applications:

• Preventive Maintenance

• Field Service

• System Production and Testing

• Fluid Cleanliness Documentation

• Flushing Process Control

FCU series Fluid Control Units

FCU 2000-4FCU 2000-1

Page 9: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

61-877-GO HYDAC

FCU 2100 FCU 2200Particle size channels 2µm / 5µm / 15µm / 25µm 4µm(c) / 6µm(c) / 14µm(c) / 21µm(c)

Measurement Range NAS 2 to 12 SAE 2 to 12ISO 13/11/10 to 23/21/18 ISO 13/11/10 to 23/21/18

Indication Range NAS 2 to 15 SAE 2 to 15ISO 12/10/9 to 25/23/21 ISO 12/10/9 to 25/23/21

Accuracy ± 1/2 class (ISO, NAS, SAE)

Calibration ISO 4402 ISO 11943

Recalibration Recommended every 2 years

Log Memory Can accommodate up to 3000 measured values / 100 Test Headers

Inlet Operating Pressure 45 to 5000 psi

Outlet Flow Rate 800 ml/min max

Outlet Operating Pressure max 45 psi back pressure

Measurement Flow Rate 50 - 150 ml/min

Permissible Viscosity Range 1 to 1000 mm2/sec (inlet port, see graph below) / 1 to 150 mm2/sec (suction port, continuous operation) /

150 to 350 mm2/sec (suction port, brief operation, 10 min.)

Fluid Temperature Range 32° to 160° F

Supply Voltage 24 V DC, ± 25% or 110 V AC with supplied adapter

Wattage 25 W max 100 W max

Battery Powered Measurement without pump or pump supplied externally: up to 6 hoursOperating DurationSerial Port RS 232 with 15-pin Sub D plug

Ambient Temperature Range 0° to 130° F

Storage Temperature Range -4° to 185° F

Relative Humidity max 90%, non-condensing

Protection Type IP40

Weight ≈ 30 lbs

The minimum inlet pressure required to achieve a flow rate of 100 ml/min for a given viscosity can be found byreferring to the graphic below. The required inlet pressure increases with increasing clogging of the filter element.

Technical Data:

0

375

300

225

150

75

0

450

1000 2000 3000

Viscosity / SUS

Pressure Required at the FCU High-Pressured Port(inlet) for a Flow Rate of 100 ml/min

(Flow regulator opened, new filter element)

Pre

ssur

e /

psi

4000 5000

Page 10: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

FCU 22 10 1 K KIT

SeriesFCU = Fluid Control Unit

Model21 = 3 digit ISO 4406 Code (>2/>5/>15µm) and NAS 163822 = 3 digit ISO 4406 Code (>4/>6/>14µm) and SAE AS 4059

Media10 = Mineral Oil11 = Phosphate Ester/Skydrol (not available with pump option -4)

Options1 = Standard4 = Integrated Pump

Supply VoltageK = 110V

Component PackageKIT = Includes Components• Minimess Adapter to SAE-6• One Inlet and One Outlet Hose• Software Package - Download from www.hydac.com (CoCos light)• PC Cable• Power Adapter• Instruction Manuals• Shipping Case

Additionally for FCU 2xxx-4:• Second power adapter• Suction hose 6mm bore (1m length)• Suction hose 6mm bore (0.2m length)

FCU Accessories Part NumberAluminum Transport Case for FCU-1 Series 00349153

Aluminum Transport Case for FCU-4 Series 03040814

Printer Paper (5 rolls) 00349155

Printer Ink Ribbon 00349156

Line Adapter 110V 03090803

High Pressure Hose (2 meters / 6.5 feet) 00349150

Return Hose (2 meters / 6.5 feet) 00349151

Fluid Service Catalog

Contamination Monitors

7

Model Code:

FCU Accessories:

Page 11: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

81-877-GO HYDAC

mode

7

memory

8

print

9

limits

4

setup

5 6

ISO

1

NAS

2 3

0

okstart

stop

-

+

+-

Flow ControlFluid Control Unit

10.0"(254 mm)

5.6"(142 mm)

12.4"(315 mm)

12.3"(312 mm)

18.0"(457 mm)

Caution!Do notlock OUTLET

Max. 3bar 43 PSI

INLETMax. 350bar 5000 PSI

O / I POWER INPUT24 V= / 1 A

Filter Element0060 D 005 BN/HC

PC CONTROL

A B

C

D E

F

G

H

Dimensions: FCU 2000-1 FCU 2000-4

mode

7

memory

8

print

9

limits

4

setup

5 6

ISO

1

NAS

2 3

0

okstart

stop

-

+

+-

Flow ControlFluid Control Unit

14.3"(364 mm)

5.8"(148 mm)

16.5"(419 mm)

Filter Element

12.3"(313 mm)

17.7"(450 mm)

OUTLETMax. 3barMax. 43 PSI

INLETMax. 350barMax. 5000 PSI

INLETMax. 350barMax. 5000 PSI

O / I

POWER INPUTPump24 V-2.3A

POWER INPUT24 V-/1A

Filter Element0060 D 005 BN/HC

PC CONTROL

A B C D E

F

G

HI JKL

CautionDo notlock

SUCTIONINLET

SUCTIONINLET

A = Outlet (return flow to tank)B = Inlet (high pressure port)C = Filter CoverD = On/Off SwitchE = Power Supply Connection (main)F = PC Connector (serial port)G = Control ConnectorH = Case Ground

A = Suction Inlet (suction port)B = Outlet (return flow to tank)C = Inlet (high pressure port)D = On/Off SwitchE = Power Supply Connection (main)F = PC Connector (serial port)G = Control ConnectorH = Power Supply Connection (pump)I = Filter CoverJ = Case GroundK = Ball Valve (for INLET/high pressure port)L = Ball Valve (for SUCTION INLET/suction port)

Page 12: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

9

Description:The CS Contamination Sensor is a new solid contaminationsensor for detecting and monitoring solid contamination inhydraulic, lube and fuel oil. The CS Sensor continuouslymonitors the condition of the fluid and transmits the infor-mation to a variety of devices in real-time!

The data can be transmitted in various formats, allowingthe user to display contamination levels, program alarmsand/or warnings, activate or de-activate auxiliary filtrationloops, or examine via HYDAC software.

The Sensor technology used is the same as that in ourportable FCU series contamination monitors and has beenproven as a successful means of detecting solid contami-nation particles.

The HYDAC sensor concept provides a distinct durabilityadvantage. The CS Sensor is NOT sensitive to vibration,optical system contamination, pressure pulsations, fluidcolor, turbidity, or continuous high fluid temperatures.

Applications:This unit can be applied to any hydraulic system in whichcontamination monitoring is critical. It is designed for per-manent installation in the system. Common applications ofthe CS Sensor Include:

• Lube-oil systems

• Paper mills

• Power generation plants

• Steel mills

• Flushing Process Control

• Fuel oil systems

CS series Contamination Sensors

WarningLamps

PLC

User’sSoftware

HYDACSoftware

ISO Code Displays

Features:• Online installation

(pressures up to 5000 psi w/ external relief)

• 4-bolt cushioned mounting

Data Output To:• PC - via HYDAC software (included)

• Programmable logic controllers (PLC)

• Warning lamps via relays

• Local ISO class display (customer supplied)

• 4 to 20mA or DIN-Messbus or Ethernet

Page 13: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

101-877-GO HYDAC

CS 21 3 0 - 1 - U / -1 -2

SeriesCS

Model21 = 3 digit ISO 4406 Code (>2/>5/>15)22 = 3 digit ISO 4406 Code (>4/>6/>14)

Enclosure3 = Stationary

Fluids0 = Standard mineral fluids and mineral based synthetics1 = Phosphate esters (e.g. Skydrol, Hyjet)

Modification Number1 = Standard

Supply VoltageU = 24 VDC

Pressure Range1 = 280-560 psi (for pressures from 560 to 5000 psi see below*)2 = 70-210 psi3 = 28-140 psi

Output0 = RS232 (DIN-66348 protocol) (enables easy communication with Hydac Software (CoCoS)1 = 4 - 20 mA2 = DIN-Messbus (enables communication with HYDAC software)5 = Ethernet

* For pressures above 560 psi - Reduce the pressure to between 280 and 560 psi. Please contact HYDAC for details.

Model Code:

35mm(1.38")

22mm(0.87")

Power Signal

194mm(7.64")

209mm(8.23")

134mm(5.276")

65mm(2.56")

105mm(4.13")

25mm(0.984")

15mm(0.59")

173mm(6.81") M6

38mm(1.5")

1/4" BSPPInlet

1/4" BSPPOutlet

Dimensions:

Page 14: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

11

Description:The CS 1000 Contamination Sensor is the newest HYDACdevelopment for continuous measurement of solid contam-ination of fluids on the market.

The latest technology and materials combine with proventechniques make the CS 1000 a small, reliable measuringinstrument that is permanently mounted on your mobile orindustrial applications.

The attractive cost-to-performance ratio makes it especiallyinteresting for OEM applications. Online, real-time conditionmonitoring allows you to have total predictive maintenance.

Applications:Monitoring system on OEM vehicles such as

• Construction equipment• Agricultural machinery• Mobile and stationary mining equipment

Industrial hydraulic systems• Integration in Monitoring Systems

via 4 to 20mA.

Combination with filter unit

CS 1000 series Contamination Sensors

Technical Details:Self-diagnosis continuously with error

indication via status LEDMeasuring range Display up to class ISO 28/27/26

Calibration within the range ISO13/11/10 to 23/21/18

Operation pressureInlet 450 bar max / 6550 psi maxOutlet 450 bar max / 6550 psi maxConnectorsInlet Thread G 1/4, ISO 228Outlet Thread G 1/4, ISO 228Sensor flow rate 30 - 300 ml/minPermissible viscosity range 1 - 1000 mm2/s 15-5000 SUSFluid temperature range 0 to 85°CPower supply voltage 9 - 36 VDC, residual ripple < 10%Power consumption 3 Watt maximumElectrical specification

4 to 20 mA output: Max. 330Ω0 to 10 V output: Min. 820ΩMax. current 1.5 A

Electrical outputsAnalog Interfaces SAE A-D (Default),

SAE-Code (A/B/C/D), ISO-Code, Temperature

Limit Switching Output SAE A-D (Default), SAE-Code (A/B/C/D),ISO-Code, Temperature

RS485 (reserved for future use)Hydac Single Wire Interface (for HMG 3000)

Ambient temperature range -30° to 80°CStorage temperature range -40° to 80°CRelative Humidity max. 95%, non-condensingMaterial of sealing FPMElectrical safety class III (low voltage protection)

IP class IP67Weight 1.3 kg

We do not guarantee the accuracy or completeness of this informa-tion. The information are based on average working condition. Forexceptional operating conditions please contact our technicaldepartment. All details are subject to technical changes.

Features:• Version with or without display• Measurement of solid particle contamination

in hydraulic and lubricating fluids • Compact and rugged design• Type of protection IP67• Max. pressure 6500 psi (450 bar)• External flow condition

avoids internal clogging of orifices• Voltage supply 9-36VDC• Data output 4-20mA, customized• Display with 6-digit ISO Code (optional)

• Display with pivot-functionwithout display

with display

Page 15: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

121-877-GO HYDAC

CS 1 2 2 0 - A - 0 - 0 - 0 - 0 / - 000

SeriesCS = Contamination Sensor

Resolution1 = 4 Particle Size Channels

Indicator Code2 = ISO 4406 : 1999; SAE AS 4059 (D)

>4 µm( c) >6 µm( c) >14 µm( c)>21 µm( c)

Options1 = without Display2 = with Display

Fluids0 = based on mineral oil1 = for Phosphate Esters

Analog InterfacesA = 4 to 20 mAB = 0 to 10 V

Switching Output0 = Limit Switching Output

Digital Interfaces0 = RS485 (reserved for future use)

Electrical Connection0 = Plug M12x1, 8-pole (connector not included)

Mounting0 = Pipe mounting / Wall mounting1 = Flange mounting

Modification Number000 = standard

Scope Of Delivery- CS- Manual- Calibration Certficate

Accessories- Connection cable 2m with M12x1 connector, 8-pole- Connection cable 5m with M12x1 connector, 8-pole

Model Code:

0.79”(20mm)

2.36”(60mm)

ø 0.20”(5mm)4 Place’s

4.19”(106.5mm)

3.27”(83mm)

30°

2.15”(54.5mm)

ø 0.35” (9mm) thruCounterbore

ø 0.59” x 0.31”(15mm x 8mm) DP

Contamination Sensor CS

ISO SAE Flow Out Drive Temp

Esc o.k.

SP1

Status

SP2

Dimensions:

Page 16: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

13

Description:The AS2000 series AquaSensors are stationary, microprocessorbased measurement units for the continuous monitoring ofthe water saturation level and temperature in hydraulic andlubrication systems. The saturation level indicates the percentage of maximum possible water is dissolved in theoil. A reading of 0% would indicate an oil free of water,while a reading of 100% would indicate oil that is saturatedwith water. The saturation level and temperature are reportedcontinuously to the integrated display and alarm relays andcan be captured via PLC, PC, etc.

Water in Oil:It is almost certain that there is water present in hydraulicand lubrication systems. These systems should be operatedwithout the presence of free or emulsified water. The mostcommon sources of water entering a system are ambienthumidity, “splash” from process water, and new oil. Watercontamination will accelerate the aging process of the oilresulting in oil oxidization, additive depletion, reduced lubrication, corrosion and damaged components. Most ofthese costly problems can be avoided by monitoring thewater content of the operating fluids.

Sometimes the water content is difficult to determine, butwith the new AquaSensor, determining the amount of wateris easy! The most practical method for monitoring watercontent in oil is as a percent of the saturation level.Different oils are capable of dissolving varying amounts ofwater, therefore they have varying water saturation curves.The curve to the right is an example of the typical relationship of water saturation level versus fluid temperature in hydraulic and lubrication oils. By looking atthe example graph it can be seen that this fluid is capableof holding more water, or has a higher saturation level, asthe temperature increases.

AS series AquaSensor Water Content Sensors

The AquaSensor is available in only one version with the following specifications:Measuring Range 0-100% %Saturation (%S)

-4° to 250°F (-20° to 120°C)

Accuracy +/- 2%S, +/- 4°C

Power Supply 24 V DC

Analog Outputs 4 - 20 mA for %S and Temperature

Alarm Relays 2 x %Saturation / 2 x Temperature

Serial Interface RS485

Display With display for %S and temperatureand keys to program the alarm relays

Sensor Cable Length 3 meters (9.8 feet)

Probe Stainless Steel, 210mm (8.27 in) in length

Operating Pressure -7.25 to 145 psi (-0.5 to 10 bar)

Fluids Mineral oils, Gear oils, Synthetic Esters

Connection G1/2 BSPP

Protection IP65

Flow Velocity max 4.5 m/sec

Fluid Temp Range 41° to 194°F (5° to 90°C)

Ambient Temp Range 14° to 158°F (-10° to 70°C)

Technical Details:

1200

1000

800

600

400

200

01048668503214-4 122

Dissolved Water

Temperature in °F

Wat

er C

onte

nt in

PP

M

Free and Emulsified Water

Example of a Hydraulic Oil Saturation Curve

Page 17: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

141-877-GO HYDAC

Model Code:AS 2 3 3 0 - 1 - U

TypeAS = AquaSensor

Measuring Range2 = Saturation level 0-100%; temperature -20 to 120°C

Version0 = 4-20mA output3 = 4-20mA output + display + RS485 interface + switch outputs

Enclosure3 = For stationary use

Fluids0 = For standard mineral fluids

Length of Cable (up to tip of probe)1 = 3000 mm

Supply VoltageU = 24 VDC

Dimensions:

Scope Of Delivery

- AS

- Stainless steel screw connection 1/2“ with cutting ring

- Manual

esc

AquaSensor

esc

AquaSensor

ø 0.47" 12mm

G 1/2

8.27"210mm

2.09"53mm

4.21"107mm

5.51"140mm

4.21"5mm

1.61"41mm

4.72"120mm

0.20"5.1mm

3.25"82.5mm

5.12"130mm

Page 18: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

15

Description:The AS 1000 series AquaSensors are stationary, microproces-sor based measurement units for the continuous monitoringof the water saturation level and temperature in hydraulicand lubrication systems. The saturation level indicates the percentage of maximum possible water is dissolved in theoil. A reading of 0% would indicate an oil free of water,while a reading of 100% would indicate oil that is saturatedwith water. The saturation level and temperature are out-putted as 4 to 20mA signal.

Water in Oil:It is almost certain that there is water present in hydraulicand lubrication systems. These systems should be operatedwithout the presence of free or emulsified water. The mostcommon sources of water entering a system are ambienthumidity, “splash” from process water, and new oil. Watercontamination will accelerate the aging process of the oilresulting in oil oxidization, additive depletion, reduced lubrication, corrosion and damaged components. Most ofthese costly problems can be avoided by monitoring thewater content of the operating fluids.

Sometimes the water content is difficult to determine, butwith the new AquaSensor, determining the amount of wateris easy! The most practical method for monitoring watercontent in oil is as a percent of the saturation level.Different oils are capable of dissolving varying amounts ofwater, therefore they have varying water saturation curves.The curve to the right is an example of the typical relationship of water saturation level versus fluid temperature in hydraulic and lubrication oils. By looking atthe example graph it can be seen that this fluid is capableof holding more water, or has a higher saturation level, asthe temperature increases.

AS 1000 series AquaSensor

Measuring range Temperatur: -25° to 100°CSaturation level: 0 to 100%

Operating pressure -0.5 to 50 bar (-0.05 to 5 MPa)

Burst pressure max. 630 bar

Flow velocity max. 5 m/sec

Nominal temperature range 0° to 90°C(when measuring saturation level)

Fluid temperature range -40° to 125 °C

Ambient temperature -40° to 100 °C

Viscosity range 1 to 5000 mm2/s 15-25000 SUS

Permissible fluids Fluids based on mineral oil andsynthetic and natural esthers

Parts in contact with fluid Stainless steel, FPM (AS1008)/ EPDM (AS1108) seal, vacuum metallized ceramic

Mechanical connection G 3/8A DIN 3852

Torque rating approx. 25 Nm

Weight approx. 145 g

Protection class IP67

CE mark EN 50081-1, EN 50081-2, EN50082-1, EN 61000-6-2

Reverse polarity protection of thesupply voltage, excess voltage, Standard override and short circuit protection

Supply voltage 12 to 32 V DC

Residual ripple ≤ 5 %

Output data

Saturation level 4 to 20mA (0 to 100%), calibrated accuracy≤ ±2% FS max., accuracy when measuringin fluid ≤ ± 3 % FS typically, pressuredependence +0.02% FS/bar

Temperature 4 to 20mA (-25° to 100°C), accuracy ≤ ± 2 % FS max.

Technical Details:

note: FS (Full Scale) = relative to the full measuring range

1200

1000

800

600

400

200

01048668503214-4 122

Dissolved Water

Temperature in °F

Wat

er C

onte

nt in

PP

M

Free and Emulsified Water

Example of a Hydraulic Oil Saturation Curve

Page 19: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Contamination Monitors

161-877-GO HYDAC

Model Code:AS 1 0 0 8 - C - 000

TypeAS = AquaSensor

Series1 = 1000 series

Fluids0 = based on mineral oil1 = phosphate esters (HFD-R)

Mechanical Connection0 = G 3/8A DIN 3852

Electrical Connection8 = Plug M12x1, 5-pole (connector not included)

Signal TechnologyC = Saturation level 4 to 20 mA (0 to 100%), Temperature 4 to 20 mA (-25° to 100°C)

Modification Number000 = Standard

Items supplied• AquaSensor• Manual

Dimensions:

Accessories:ZBE 08Right-angled connector(5 pole, M12x1)ZBE 08S-02Right-angled connector(5 pole, M12x1) with 2 mcable, screened(ZBE 08-02, not screened)

ZBE 08S-05Right-angled connector(5 pole, M12x1) with 5 mcable, screened(ZBE 08-05, not screened)

ZBE 08S-10Right-angled connector(5 pole, M12x1) with 10m cable, screened

ZBE 08

ZBE 08S

Circuit Connection:

ø 0.47"(12mm)

0.86"(21.9mm)

1.16"(29.5mm)

2.18"(55.3mm)

G 3/8 A

2.64"(67.1mm)

1.18"(30mm)

0.47"(12mm) 0.10"

(2.5mm)

ø 1.06"(27mm)

SW 27

SignalSaturation Level

SignalTemperature

RL

RL

1

5Pin 5 not to be connected

2

4

3Ground

+ Ub

AS 1000

1.04"(26.5mm)

1.24"(31.50mm)

1.38"(35mm)

ø 0.79"(20mm)

1.10"(28mm)

Page 20: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

• Definable displaysDefine which measured variables should appear onthe unit display.Ex: User display 1 of 5: current temperature value,peak value of the flow rate, minimum pressure valueand current rpm value.

• Identification of recorded curves or logsThe user can program in a specific ‘company name’and assign a specific station number to the systembeing presently worked on. This specifies which sys-tem each measurement was recorded from.

• Printer OptionsThese options enable print outs (black & white or color)to be done on commercially available printers.Additional details can be obtained from the technicalinformation in this brochure, or simply by contacting one of our distributors.

Fluid Service Catalog

Diagnostics

17

HMG 2020 Portable Data Recorder

The HMG 2020 generally distinguishes between threemeasurement options:

1. Normal measurementPurely a display function where the measured values aredisplayed immediately.Ex: When HMG is measuring with pressure sensors to actas a digital gauge.

2. Curve measurementThe measured values are displayed and simultaneouslystored continuously in the internal memory. The coursesof the curves can be printed out on the printer as soonas measuring has stopped, or transferred to a PC andviewed with the software.

3. Log measurementThe measured values are displayed and can be stored aslog entries in the internal memory. This method of meas-urement is used primarily for long-term measurements(e.g. one week, one month, one year etc.). The log entries canbe printed out on a printer as soon as measuring hasstopped, or transferred to a PC.

The internal memory can store up to 50 different curves andlogs with 250,000 measured values in total.

To optimize your measurements the unit has a wide varietyof additional functions:

• Choice of languageThe user may define which language the unit will displaythe data and parameters.

• Two trigger possibilitiesDefinition of events which start a curve measurement orwhich, on a log measurement, transfer the current measuredvalues to memory.Ex: A curve is to be recorded when the temperatureexceeds 50°C or the system pressure falls below 25 bar.The two triggers can in addition be linked together logically(and/or following one another chronologically), so that data isrecorded exactly at the required moment.

Ordering Information:Standard American Unit: HMG 2020 - 004 - ECall your distributor for details on available options

Description:The HMG 2020 is a portable data recorder for recording pressure, temperature, flow rate, rpm etc. in industrial machinery and systems(e.g. hydraulics, pneumatics). The HMG 2020 can record the measured valuesfrom up to five sensors simultaneously.• 2 inputs for 4 to 20 mA sensors

• 2 inputs for either 4 to 20 mA or 0 to 10 V sensors

• 1 frequency input for digital signals in the range 0.3 to 30,000 Hz

• The measurement range and the unit for each sensor can be set as required(e.g. 0 to 250 bar, -25° to 100°C, 0 to 217 KN). Therefore, the majority of commer-cially available sensors with standard output signals can be connected andevaluated.

• As well as the current measured values, the unit also records the minimumand maximum values, in addition to the differential between two sensors ofthe same type.

Deluxe HMG Diagnostic Kitask your distributor for details

Page 21: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Diagnostics

181-877-GO HYDAC

Multiple graphs and whole measurement curve

Zoomed section from overlayOverlay of two curves

HMGWINThe HMGWIN PC program expands the measurement options ofthe portable HMG 2020 data recorder. HMGWIN is compatiblewith Windows 95/98/NT, user friendly, an interactive softwarepackage that allows the user to download the stored data andstudy it in greater detail.

For the user who wishes to store or further evaluate the recordedmeasurement curves and measurement logs, this HMGWIN providesa range of useful functions.

Features:

• Transfer and Storage of curves and logsfrom the HMG 2020 to a PC.

• Viewing of up to 4 different recorded curve orlog measurements simultaneously on the monitor.

• Superimposition of curvesParts of different curves can be superimposed in a new graph, for example to show the wear and tear of a machine (new condi-tion/current condition).

• Straight edge functionAs with a straight edge, you can measure the curves using themouse (exact time and amplitude value). Absolute measured val-ues and also relative measured values (measurement in relation toa set marker) can be displayed.

• Zoom functionUsing the mouse, part of a graph can be framed. The framedarea appears as a new graph, enlarged accordingly.

• Online functionThe portable data recorder measures and transfers the currentmeasured values straight onto the PC. These are then immediatelydisplayed as a graph in realtime (comparable with the function ofan oscilloscope). The graph displayed can be stored if there areany interesting results.

• Portable data recorderSettings can be transferred to the PC and may be stored. Thereverse is also possible, so, for example, settings for takingmeasurements on a particular machine can be fed into theHMG 2020 again and again.

• Data conversionHMGDESK can convert the HMG 2020 data into some otherdata formats. This means, for example, that the recordedcurves can be transferred to many other PC programs (spread-sheets, database, word processing etc.) and further processed.

For complete details on the HMGportable data recorder, and HYDAC’sfull line of pressure, temperature, andflow rate sensors and switches, pleaserequest our Electronics Catalog.Part Number: 02075078

Page 22: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Analysis Service

19

Fluid Analysis Service

HYDAC hydraulic components have an unequaled reputationfor quality, reliability and performance. We built that reputationon a tradition of customer service, and stand behind everyone of our products.Our Fluid Analysis Service follows that same tradition. Weprovide our customers with comprehensive fluid testing anddiagnostic services, with detailed reports that are easy tounderstand.To find out how the HYDAC Fluid Analysis Service can helpyour operation, read on. Then call us to get started.

A Name You TrustOnly one fluid analysis lab lets you put years of HYDACexperience to work for you. That’s because nobody knowshydraulics like HYDAC. So when the health of yourhydraulic system is at stake, choose a partner with morethan 25 years of experience. Contact your HYDAC repre-sentative for more information on our Fluid Analysis Service.

Critical AnalysisFluid is the lifeblood of every hydraulic power system. Tokeep yours running efficiently and effectively, you need toknow what’s in it. What you don’t know can hurt you.The HYDAC Fluid Analysis Service analyzes hydraulic fluidin much the same way a medical lab tests a blood sample.Just as a blood test helps a doctor diagnose health problems,a sample of hydraulic fluid can help us pinpoint sources of contamination and determine whether or not your systemuses adequate filtration.We can help you reduce catastrophic equipment failures,maintain optimum component performance, and identify anysubstandard maintenance practices. Your bottom-line benefitis increased productivity.

Clear BenefitsWe offer testing designed to tell you the most about yourhydraulic fluid. We use sophisticated computer programsand laboratory diagnostic equipment such as an EnergyDispersive X-ray Fluorescence, and an inductively coupledplasma spectrophotometer.After we use this advanced equipment to provide the mostdetailed possible analysis of your hydraulic fluid, we createreports that are always easy to read and understand. By tak-ing the mystery out of fluid analysis, we provide a servicethat clearly explains the benefits of clean fluid.

Page 23: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Comprehensive TestingThe HYDAC Fluid Analysis Service offers a full range oftests specifically designed for the analysis of hydraulic and lubrication system fluid. Our laboratory equipment and testprocedures provide an exact analysis of your hydraulic or oillubricated system, and our drawdown particle isolation procedure ensures accurate results.

Fluid Service Catalog

Fluid Analysis Service

20

Our testing procedures can include:Photomicrography:We scan and photograph a filter patch using an opticalmicroscope to find particle size and type. The scanningprocess verifies the automatic particle count to identify samples needing special preparation. This provides confirmation of automatic counter results, and helps us see what contaminants are in the fluid.

Viscosity (ASTM D445):We use this test to determine the viscosity of your oil.Without proper hydraulic fluid viscosity, your equipment willsuffer. Incorrect viscosity leads to fluid breakdown, inefficientequipment operation, premature system failure, and damageto other components.

Water (ASTM E203):We determine the water content in hydraulic fluid, whichhelps us predict quality and performance characteristics for the fluid and system components. Excess water reduces the viscosity of hydraulic fluid, which increases the likelihood of adverse chemical reactions and degradesequipment performance.

Drawdown Particle Isolation:Using this test, we determine the insoluble contaminates in hydraulic fluids, both insoluble particles and gel-like matter, organics and inorganics. Used in conjunction withphotomicrography, the drawdown patch helps us identify the source and type of fluid contaminants.

Automatic Particle Count (ISO 11500):We use a high-intensity laser light source and a photo sensor to count the number and size of particles in the fluidsample, and then define contaminants according to size distribution and quantities. Automatic particle counting isquick, repeatable and accurate. It provides reliable informationwe can use to check against ISO Standard 4406, whichdefines the relationship between particle counts andhydraulic fluid cleanliness. This lets us determine exactlywhat corrective actions—if any—are needed. The lab is also capable of testing to the new ISO 4406 (1999) standard (4µ, 6µ,14µ).

Spectrometric Analysis (ASTM D 5185):This shows us the concentration of oil-soluble elements, and indicates the additives and trace metal content in thefluids. We use this technique to evaluate the condition of the additives in a fluid rather than its particulate contamination.Used in conjunction with automatic particle counting, it helpsus accurately assess the cleanliness level of the fluid.

Energy Dispersive X-ray Fluorescence (ASTM E 1508):We perform Energy Dispersive X-ray Fluorescence (XRF)analysis on samples with extremely high concentrations ofparticulate contamination. By isolating chemical elements,we pinpoint contaminant types so we can establish their origins, and so you can take corrective action.

1-877-GO HYDAC

17/15/12

20/18/15

23/21/18

Page 24: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Analysis Service

21

Results Target:A results target compares your actual fluid cleanlinessresults and your ideal cleanliness level. If you don’t have atarget level yet, we can use your sample to help you deter-mine what it should be.

Easy-to-Read ReportsWe present your fluid test results in a format that is easy to understand. Results typically include these items:

Trend Information:We evaluate data from your previous two samples alongwith the results of your current sample. This provides a trendanalysis of critical measurements, and shows changes in thefluid over time.

pH (ASTM E 70) represents the strength of acidity inhydraulic fluid, and is usually measured for water-containinghydraulic fluids (water/glycols, invert emulsions). Typicalvalues are 8.5–10.5.

Total Acid Number, or TAN (ASTM D 974), is the amount ofacid and acid-acting material constituents in hydraulic fluid.An increase in TAN indicates oxidation or acid contamina-tion. Some hydraulic fluids exhibit higher acid numbers thanothers. Typical values are 0.1–3.0.

TimeViscosity@ 100˚F

cSt (SUS)

Water %Weight pH1) TAN mg

KOH/gm2)

Test 1Present

45.0 (210) 0.03% 9.4 2.1

Test 2Previous #1

45.5 (212) 0.03% 9.5 2.0

Test 3Previous #2

45.8 (213) 0.03% 9.6 2.1

Time >4µ >6µ >10µ >14µ >21µ >50µCleanliness

Code

Test 1Present

65,120 12,220 5,800 900 125 12.0 23/21/17

Test 2Previous #1

4,100 1,250 700 250 60 5.0 19/17/15

Test 3Previous #2

418 88 39 22 4 1.0 16/14/12

Particle Count Summary

Fluid Results

52

VISCOSITY

WATER 15

On-target

Marginal

Re-sample

Immediate action required 1) pH is for water- containing fluids only.2) TAN is for synthetic fluids only.

Page 25: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Analysis Service

221-877-GO HYDAC

Cleanliness Code Graph:This graph uses the ISO 4406 standard for measuring anddepicting the amount and size of particles per milliliter inhydraulic fluid, shown in a log-log2 graph that charts theamount of particles greater than certain micron sizes permilliliter of fluid.

Recommendations:This section of the report provides you with valuable infor-mation on the cleanliness of your hydraulic system, as wellas tips on maintaining or improving its current condition.

0

10

20

30

40

50

60

70

80

90

100

Ca P S Fe ZnElement

Per

cent

Sample XRF Analysis ResultsWhen a fluid sample shows high particulate contamination, we useEnergy Dispersive X-ray Fluorescence (XRF) analysis to isolate andidentify chemical elements. The results are shown in a graph like this.

Kit Part NumbersFluid Analysis Kit - Premium: 02080533 particle Count, Water, TAN/PH (as applicable), Viscosity,Microscopy, XRF (as applicable), Spectrographic Analysis

Fluid Analysis Kit - Basic: 02080534particle Count, Water, TAN/PH (as applicable), Viscosity.

Fluid Analysis Sampling Pump: 02080531Vacuum pump for extracting oil sample.

Each Fluid Analysis Kit includes the following:• Super clean sample bottle. • Numbered test sample data form (must be filled out com-

pletely to receive the most accurate test results, includingtrend information and E-mail)

• Packaging for mailing sample. • Prepaid fluid analysis services

Range Code

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

100.000

10,000

1,000

100

10

1.0

.1

.01

300,000200,000150,000

50,00040,00030,00020,00015,000

5,0004,0003,0002,0001,500

500400300200150

5040302010

54321.5

.5

.4

.3

.2

.01

1 2 5 10 15 20 25 30 354045 50Paritcle size in micrometers

Num

ber of p

articles greater than size per m

ililiter

20/14/15Cleanliness code

100,000

80,000

40,000

20,000

10,000

5,000

2,500

1,000

500

250

100

80

40

20

10

5

2.5

1.5

1

.5

.15

.08

.04

.02

Page 26: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog23

Fluid Analysis Kits

Description:The static sampler is used to take samples from systemreservoirs. By creating a vacuum in the pre-cleaned samplebottle, the fluid is drawn from the tank at the required level.

For a representative investigation of stray particles in thehydraulic system, dynamic sampling is preferred.

The required sample volume is taken from a pressure lineusually through a testpoint with a minimess flexible hose,after the valve has been flushed.

Applicable Standards:ISO 4021CETOP RP 95 H

FES series Fluid Extraction Set

Quantity Description1 Vacuum pump with gauge1 Aluminum adapter1 2 sampling bottles1 Wash bottle (500 ml)

with removable syringe1 2 Disposable membrane filters

for wash bottle1 2 meter flexible PVC hose1 Telescopic pointer (90 cm)

for accurate mid-tank sampling1 Cable ties (20 pcs.)1 Dynamic sampler1 Minimess flexible hose

(screw/screw)1 Minimess flexible hose

(screw/push-in)1 Sampling bottle (500 ml)1 Case1 Operating Manual1 Contamination Handbook

Items Included in the Kit: Replacement Parts:Quantity Description Part No.

1 Vacuum pump with gauge 3093451 Aluminum adapter 3093491 2 sampling bottles 3093521 Wash bottle (500 ml) 309358

with removable syringe1 2 Disposable membrane filters 309371

for wash bottle1 2 meter flexible PVC hose 3093741 Telescopic pointer (90 cm) 309342

for accurate mid-tank sampling1 Cable ties (20 pcs.) 6275001 Dynamic sampler 3093481 Minimess flexible hose 309350

(screw/screw)1 Minimess flexible hose 309351

(screw/push-in)1 Sampling bottle (500 ml) 3093601 Case 6375611 Operating Manual1 Contamination Handbook 349339

Page 27: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Analysis Kits

241-877-GO HYDAC

Description:The Water Test Kit is used for the quantitative analysis ofwater content in percent by volume of mineral and lubricat-ing oils. Adding two reagents to the contaminated oil caus-es an increase in pressure in the measuring cell. This pres-sure increase can be read off the digital display as watercontent in percent by volume or ppm.

Measurement ranges selectable: 0.02 to 1%; 0 to 10%; 0 to 20% and 200 to 10000 ppm

Test time: only approx. 2 minutes (excluding sample preparation)

Ordering Information:

WTK 200 / -D

WTK series Water Test Kits

Quantity Description1 WTK measuring Cell2 Reagent A, 500 ml bottle50 Reagent B, sachets3 Disposable - 5 ml10 Disposable syringe - 1 ml100 Gloves1 Tweezer1 Scissor1 Measuring cup - 100 ml1 Case1 Operating Instructions

Items Included in the Kit:

Description Part No.Replacement pack consists of: 06030669Reagent A, 500 ml bottleReagent B, sachetsDisposable - 5 mlDisposable syringe - 1 mlGlovesTweezerScissor

Content sufficient for 50 tests

Replacement Parts:

Page 28: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Analysis Kits

25

Description:The Fluid Analysis Set with electric vacuum pump andfiltration unit to laboratory standards is used to producecontamination reports from oil samples. The referencephotographs, found in the contamination handbook,enable a quick evaluation of the contamination levels inthe fluid. A microscope (sold separately - see page 18)can be used to determine the type of particle and there-fore its origin in the hydraulic system. Precision scales(not supplied) can be used to determine the gravimetriccontamination content of the fluid (ISO 4405.)

Ordering Information: FAS K 2: 110 V / 60 Hz electric vacuum pump

FAS series Fluid Analysis Sets

Quantity Description1 Carry case1 Silicone hose (6 feet, 3 x 6 mm Ø)1 Membrane filter disc1 Electric vacuum pump1 Centering ring with strainer1 Vacuum filtration device1 Measuring cylinder (100 ml)1 Sampling jar (500 ml)50 Petri slides1 Wash bottle with membrane filter1 Contamination handbook

Items Included in the Kit

Quantity Description Part No.1 Vacuum filtration device 637345

• top section (250 ml)• funnel attachment• centering ring with strainer• clamp

1 Rubber plug 6373441 Suction flask (1000 ml) 6373431 Silicone Hose (6 feet, 3 x 6 mm Ø) 6389561 Electric vacuum pump (110 V / 60 Hz) 6001270 1 Electric vacuum pump (230 V / 50 Hz) 6373401 Wash bottle (500 ml) 309358

with removable syringe1 Disposable membrane filter 309371

for wash bottle1 100 membrane filter discs 309354

for mineral oil47 mm Ø, 0.8 micron

1 Tweezers (105 mm) 6373411 50 Petri slides (type PD 1504700) 3093771 Measuring cylinder with bushing (100 ml) 6373421 Sampling jar (500 ml) 3093601 Contamination handbook (not shown) 349339

Replacement Parts:

Page 29: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Analysis Kits

261-877-GO HYDAC

MM-S5-P, MM-S5-P-L, & MM-KKE-P-C-LHuygens Eyepiece 10 x MAchromatic Lens 4x, 10x, 20xMagnification 40x, 100x, 200xSupply Voltage 110 V 60 HzMM-S5-P-L & MM-KKE-P-C-L (only)Image Digitation CCD-CameraVideo System PAL color systemResolution horiz. 460 lines

vert. 400 linesImage Processing Video capture unitPC interface LPT 1 portSystem Requirements min. Pentium 100 Mhz.,

Windows 95

Technical Data:Description:This measuring microscope is designed specifically to beused for measuring contamination particles in oil sampleson filter membranes. All models include coarse and finefocusing adjustments, as well as both X and Y directionalslide table adjustments to make focusing and positioningthe subject simple, even at maximum magnification.

There is a rotating lens holder with 3 achromatic objectivelenses with magnifications of 4x, 10x, and 20x. Themicrometer eyepiece provides an additional 10x magnifica-tion resulting in 40x, 100x, and 200x magnifications. Themeasuring scale on the eyepiece has a scale division of 1mm in 100 parts, allowing measurement of particles at allthree magnifications.

These units come with an integrated plug-in light sourcethat provides sufficient illumination, even at maximummagnification.

The optional CCD digital camera attaches to the eyepieceand transfers images to a PC via a USB connection, mak-ing it easy to capture and transmit images from the micro-scope.

Ordering Information:MM-S5-P Standard eyepiece

110 V 60 Hz powered light source

MM-S5-P-L Standard eyepiece110 V 60 Hz powered light sourceCCD camera with LPT-1 port for connection to laptop or PC

MM-KKE-P-C-L Triocular eyepiece110 V 60 Hz external cold light illuminationCCD camera with LPT-1 port for connection to laptop or PC

MM series Measuring Microscopes

Page 30: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

27

Applications:The portable OF7 filtration unit is a compact filter/pumpdevice used for transferring and filtering hydraulic fluids. Itcan be used for:

• Removing water from oil• Changing oil in hydraulic systems.• Filling hydraulic systems with filtered oil.• Off-line filtration of hydraulic systems with inadequate

filtering capacity.

Design:A low noise vane pump is directly flanged to the electricalmotor and fixed to an aluminum housing with a foot bracket.The suction line has a cleanable wire screen strainer forpump protection. An AC motor is standard, DC optional.

Product Features:The OF7 is ideal for maintaining construction and agricul-tural machinery, off-highway vehicles and trucks. It isequally useful for servicing a wide variety of industrialequipment.

The standard OF7 incorporates a highly efficientBetamicron® spin-on filter element with a 10 µm absoluterating. Elements with other ratings are available. Other fea-tures of the unit include:

• Relief valve in housing.• Static pressure gauge clogging indicator.• Element easily replaced with strap wrench.

Multi-Pass Filtration EfficiencyRatings for BETAMICRON®

Elements (to ISO 4572):• Beta Ratios for differential pressures above the indicator

trip pressure are shown to demonstrate particle removalat high differential pressures.

• Beta Ratios for many competitive elements drasticallydeteriorate at high differential pressure.

OF7 series Hand Held

BETAMICRON® BN Beta Ratio Data:Betamicron Absolute Terminal

Media Rating ∆P AcrossFilter Element

003 BN ß3 ≥ 200 43 psi

005 BN ß5 ≥ 200 43 psi

010 BN ß10 ≥ 200 43 psi

020 BN ß20 ≥ 200 43 psi

Recommended Fluid Petroleum based oils. Contact HYDAC for other applications.

Nominal Flow 4 GPM / 15 l/min

Maximum Oil Temperature 180°F / 80°C

Viscosity Range 40 to 2300 SUS 5-500 mm2/sec

Max. Operating Pressure 50 PSI / 3.5 bar

Weight 27.5 lb / 12.5 kg

Electrical Motor 110 VAC (0.25 HP / 0.18 KW) or 24 VDC (0.27HP / 0.20KW)

Technical Data:

Page 31: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

28

Model Code:OF7 S 10 P 1 K 1 B 10 E

ModelOF7

TypeS = standard

Code10 = standard

SealsP = Nitrile (NBR) (standard)

Pump1 = Vane Pump (standard)

Electric Motor VoltageK = 110 VAC, 60 Hz (standard)U = 24 VDCD = pneumatic motor

Spin-on Filter Element Size1 = Size 0160

Filter Element MaterialB = Betamicron® Low CollapseP = PaperA = Water Removal

Filtration Rating (microns)0305 BN10 Absolute Filtration2010 P -Nominal Filtration10 W Water Removal

Type of Clogging IndicatorE = Pressure Gauge

Dimensions:

1-877-GO HYDAC

ReplacementElement Model Codes

Betamicron®

3 µm 0160MA003BN

5 µm 0160MA005BN

10 µm 0160MA010BN

20 µm 0160MA020BN

Paper

10 µm 0160MA010P

Water Removal

10 µm 0160MA010A

10.87276

14.37365

14.41366

≈21.26≈540

14.37365

Page 32: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

29

Applications:The OF5 Filter Carts are used to transfer and filter hydraulicfluids at a rate of 10 or 15 gpm.

Typical applications are to:

• Filter particles and/or water from new oil while filling areservoir.

• Recirculate and filter oil during start-up, when contami-nation is often heaviest.

• Recirculate and filter oil off-line on systems with inade-quate filtering capacity.

• Empty a storage tank or reservoir.

• OF5 Carts are ideal for use in industrial plants and inother demanding applications because of their efficien-cy, capacity, and durability.

Description:Two filter assemblies are staged in series so that all oilflows first through stage 1, then through stage 2 (eachassembly consists of one head and two elements). A key advantage is that the OF5 incorporates four elements toincrease the dirt-holding capacity. Moreover, the OF5 permits the use of different types of elements in eachstage, making it possible to:

A) remove particles in stage 1 and water in stage 2, or

B) remove coarse particles in stage 1 and fine particles instage 2.

Performance:HYDAC is recognized as a leader in the manufacture ofhigh-efficiency, high-capacity, absolute-rated fiberglass filters. Our Betamicron® 3 elements maintain Beta ratios inexcess of 200, meaning that they are able to remove a highpercentage of particles quickly and effectively.

As a result, the cart is capable of:

A) cleaning new oil to a low level of contamination before itis introduced into the system and

B) cleaning oil in a reservoir with a minimum number of circulation passes.

The cart is designed to capture a large quantity of particulatesbecause of the high retention capacity of the filter mediaand use of multiple, extended-length spin-on elements.

Product Features:• Choice of 3, 5, 10, or 20 µm Betamicron 3® absolute-

rated filter elements, all with Beta Ratios ≥ 200 for maximum efficiency

• Availability of water removal elements with capacity of0.45 quarts of water each

• Welded tubular steel frame for durability

• Dirt-tolerant, self-priming vane pump

• Compact design, balanced weight, and large tires foreasy handling

• Color-coded gauge for warning of clogged filter elements

• Spiral-reinforced, clear, 10’ PVC hoses with 20” steel end wands

• 520 µm cleanable strainer before the pump

Dimensions:

OF5 series Wheeled Carts

27.5"

51"

21.5"

Page 33: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

30

Technical Data:Fluid Compatibility Mineral oil, including lube & fuel oil. Note: Not allowed for use on water based fluids.

(Contact HYDAC for other applications.)

Motor 1750 rpm, 3/4 HP (series 10), or 2 HP (series 15) 110V Single Phase

Electric Cord 20’ long

Pump Direct drive vane, 10 or 15 gpm, self-priming

Absolute-Rated Filters Extended length spin-on, with 25 psi (1.7 bar) bypass

Water Removal Filters Extended length spin-on, approximately 0.45 quarts of water capacity, with 25 psi (1.7 bar) bypass

Clogging Indicators Color coded static pressure gauge

Strainer Stainless steel, 520 µm

Hoses Spiral-reinforced clear PVC, standard 10’ length, 20” steel wands (Contact HYDAC for applications requiring longer hose lengths)

Dimensions Height 51”Width 21.5”Length 27.5”

Weight of Cart With Elements 123 lbs.

Operating Range Fluid temperature 50ºF - 130ºF (10°C - 54°C)Pressure to 87 psi (6 bar)Viscosity 100 - 500 SUS

1-877-GO HYDAC

Model Code:OF5 - 10 - 03BN - 10A - S

ModelOF5 - Two Stage Filter Cart

Flow Rate10 = 10 gpm15 = 15 gpm

Filtration Rating (micron) (2 Elements Per Stage)

Stage 103BN Betamicron®

05BN Absolute ßx ≥ 20010BN Filtration20BN Rating

Stage 203BN Betamicron®

05BN Absolute ßx ≥ 20010BN Filtration20BN Rating

10A Water Removal ßx ≥

Clogging Indicator

S = Static Pressure Gauge

Replacement Element Model Codes

Betamicron® Paper Water Removal

3 µm 0180MA003BN – –

5 µm 0180MA005BN – –

10 µm 0180MA010BN 0180MA010P 0180MA010A

20 µm 0180MA020BN – –

Page 34: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

31

Features: • 18.5 gallon tank capacity

• HYDAC OLF compact offline filter with pump motor unit

• (2) 7.5 foot hoses with wands and holder

• Choice of 2, 5, 10, 20 Dimicron® or 2, 20 Aquamicron®

element with Beta ≥ 1000

• Oil drain

• Optional FCU particle counter connection

• Optional flow counter

Filter Element Dimicron® (2, 5, 10, 20 µm / absolute)Aquamicron® (3, 20 µm / absolute)

Flow Rate 1.3 / 4.9 gpm

Operating Pressure 50.75 psi

Viscosity Range FCC 5/4: 1000-10,000 SUSFCC 5/15: 75-3000 SUS

Fluid Temperature Range 32° to 176° F

Ambient Temperature Range 32° to 104° F

Seals NBR

Safety Type IP 55 (without FCU)

Mass ~133 lbs empty

Tank Volume 18.5 gallons

Length of Hoses 7.5 ft

Length of Electric Cable 33 ft

Technical Data:

Applications:The FCC Filter Carts are used to transfer and filterhydraulic fluids at a rate of 1.3 or 4.9 gpm.

Typical applications are to:

• Filter particles and/or water from new oil whilefilling a reservoir.

• Recirculate and filter oil during start-up, whencontamination is often heaviest.

• Recirculate and filter oil off-line on systems withinadequate filtering capacity.

• Empty a storage tank or reservoir.

• FCC Carts are ideal for use in industrial plants and inother demanding applications because of their efficiency,capacity, and durability.

MP S

FCC series Compact Fluid Carrier

Page 35: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

321-877-GO HYDAC

Model Code:FCC - 5/15 - S - L - N5DM002 - BM / K

ModelFCC = Compact Fluid Carrier

Size and Flow Rate5/4 = 1.3 gpm5/15 = 4.9 gpm

Pump TypeS = vane pump

Motor VoltageL60 = 115 V 60 Hz single phaseO60 = 460 V 60 Hz 3 phase

Element Type and Filtration Rating (micron)N5DM 002 = 2 µmN5DM 005 = 5 µmN5DM 010 = 10 µm Dimicron® high efficiency particle removal

N5DM 020 = 20 µm

N5AM 003 = 3 µmN5AM 020 = 20 µm Aquamicron® water removal w/ Dimicron® high efficiency particle removal

Clogging IndicatorBM = Differential indicator - visual with manual reset (model VM2BM.1)C = Differential indicator - electrical (for option FA1 and E - VM2C.0)

Additional OptionsK = Flow counterFA1 = Cut-out when filter is cloggedFCU* = Equipped for FCU connection including holder, measuring points, and switch-over valveE* = Electrical control unit for automatic control using FCU

* For use with the FCU 2000 Series. FCU must be ordered separately.

45.87"1165mm

28.74"730mm

22.68"576mm

Dimensions:

Page 36: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

33

FCM series Mobile Fluid Cleaner

Technical Data:Vane Pump Model Gear Pump Model

Max. Flow Rate FCM 60 19 gpmFCM 100 32 gpm

Operating Pressure pmax= 87 psi pmax = 145 psi

Viscosity Range 75 to 2000 SUS 75 to 5000 SUS

Permissible Operating Fluid Mineral Oil

Fluid Temperature 14° to 176°F

Ambient Temperature 14° to 104°F

Seals NBR (optional: Viton)

Safety Type IP 55

Electrical Cable Length 20 ft.

Hose Connections/Hose Length M 52x2 / 2.5 mM 36x2 / 4 m

Weight approx. 175 lbs. (FCM 60) approx. 198 lbs. (FCM 100)

Power Consumption Table:Type FCM 60 FCM 100Vane pump 1.5 kW 2.2 kW

Gear pump 2.2 kW 3.0 kW

P A

M

P A

M

without change-over with change-over

Page 37: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Model Code:FCM - 100 - L - O - 3 B03 - C / S5D5-V

ModelFCM = Mobile Fluid Cleaner

Flow Rate060 = 19 gpm100 = 32 gpm

Pump TypeL = vane pump without change-over (standard)

75 to 2000 SUSF = vane pump with change-over

K = gear pump without change-over75 to 5000 SUS

G = gear pump with change-over

Motor VoltageO = 460 V 60 Hz 3 phase

Filter Size2 = filter size 13003 = filter size 2600

Filter Design (all elements are without bypass)B03 = 3 µmB05 = 5 µm Betamicron® Low CollapseB10 = 10 µmB20 = 20 µm

A40 = 40 µm Aquamicron®

BA03 = 3 µm Betamicron®/Aquamicron® Combination (10 µm only available in size 2)BA10 = 10 µm

Clogging IndicatorB = Visual differential indicator (standard)C = Differential indicator with auto motor cut-out when filter is contaminated (model VM2C.0)

Supplementary DetailsS5 = Suction hose, 16 feet with lanceD5 = Pressure hose, 16 feet with lanceV = FPM (Viton) seals

Dimensions:

Fluid Service Catalog

Portable FIlters

341-877-GO HYDAC

29.53"750mm

49.21"1250mm

26.38"670mm

top ofsize 3(2600)

top ofsize 2(1300)

Page 38: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

35

Description: The dewatering and filtration unit FAM is a bypass unitwhich has been specially designed for the conditioning oflubrication and hydraulic fluids. Because of the use of theDimicron® filter element technology with a high contaminationretention capacity the unit works very efficiently.

Advantages: • Separation of 100% free and 90% dissolved water

through vacuum dehydration

• Separation of particles with high contamination retentioncapacity ISO 13/10 attainable

• Removal of 100% free and 100% dissolved gases

• Easy handling and supervision of the process

Applications: • Steel and roll mills

• Pulp and paper plants

• Power generation plants

• Tool machines/Plastic machines

• Oil conditioning

HYDAC FAM vs Other:• Water removal below saturation point

• Static flow through the filter only

• Most efficient particle removal

• Removed water is used to seal the vacuum pump (Vacuum Pump type S, SW only)

• The special vacuum pump concept avoids any dangerouschemical reaction products (Vacuum Pump type S, SW only)

• No corrosion within the vacuum pump

• Serviceable vacuum chamber

• Low operating costs

The contamination of hydraulic fluids with water can eitherbe caused by condensation or by penetration. Variations intemperature of the hydraulic tank lead to condensation.The penetration of water can be caused by defective coolinghoses, defective seals or external leakages into the system.

In lubrication and hydraulic fluids water can occur in twodifferent forms:

• free water (visible)

• dissolved water (not visible)

Aquamicron®, centrifuges and condensation methods normally only separate free water, the FAM separates bothforms of water from the oil. While dewatering the fluid, dissolved gases are also removed. Thereby the lubricatingproperties are improved which extends oil life, reducescomponent wear rates, and eliminates production lossescaused by breakdowns.

FAM series Water & Solid Removal

Page 39: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable FIlters

361-877-GO HYDAC

Model Code:FAM 15 M 1 O / 1900 015 DM 02 S Z 1

Basic ModelFAM = Fluid Aqua Mobile

Flow Rate10 = 3.3 gpm15 = 5 gpm30 = 10 gpm50 = 16 gpm70 = 23 gpm

Operating FluidM = Mineral OilI = Transformer Oil (heater required)B = Biodegradable OilX = Synthetic & Fire Resistant Oil (please specify exact fluid type)

Type1 = Stationary2 = Mobile

Voltage/FrequencyF = 230 V / 60 Hz / 3Ph+PEO = 460 V / 60 Hz / 3Ph+PEX = Other Voltage

Powerwithout heater with heater1500 = 1500 W (size 10) 4400 = 4400 W (size 10)1900 = 1900 W (size 15) 8650 = 8650 W (size 15)2700 = 2700 W (size 30) 19200 = 19200 W (size 30)3200 = 3200 W (size 50) 21200 = 21200 W (size 50)5100 = 5100 W (size 70) 26100 = 26100 W (size 70)

Filter Size & Number of Elements005 = 1 x N15DMxx (FAM 10 only)015 = 1 x N15DMxx (FAM 15 only)030 = 2 x N15DMxx (FAM 15 and 30 only)045 = 3 x N15DMxx (FAM 15, 30 and 50 only)060 = 4 x N15DMxx (FAM 15, 30 and 50 only)075 = 5 x N15DMxx (FAM 70 only)

Filter MaterialDM = Dimicron®

Absolute Filtration Rating (micron) 02 = 2 µm (DM)10 = 10 µm (DM)20 = 20 µm (DM)30 = 30 µm (DM)

Vacuum Pump Type/SizeD = Rotary vane pump (operating fluid I, X)S = Standard watering / vacuum pumpSW = S with automatic cooling water fill

Measuring EquipmentA = AquaSensorZ = without

Modification Number (latest version always supplied)1

FAM 10 FAM 15 FAM 30 FAM 50 FAM 70Filter Size OLF-5 OLF-15 OLF-30 OLF-45 OLF-70Filter Element N15DMxxx(1x) N15DMxxx(1x) N15DMxxx(2x) N15DMxxx(3x) N15DMxxx(5x)Capacity of Pressure Vessel gal(liters) 1.25(4.75) 5.25(20) 10.5(40) 20.5(78) 26.25(100)Solid Contamination to ISO 4572 lbs(g) 0.45(200) 1.1(500) 2.2(1000) 3.3(1500) 5.5(2500)Electric Clogging Indicator VM 2C.x VM 2C.x VM 2C.x VM 2C.x VM 2C.xBypass Cracking Pressure psi(bar) 29 (2) 29 (2) 29 (2) 29 (2) 29 (2)Pump Type Vane pump Gear pump Gear pump Gear pump Gear pumpFlow rate gpm 3.3 5 10 16 23Maximum Operating Pressure psi(bar) 50.75(3.5) 87(4.5) 87(4.5) 87(4.5) 87(4.5)Viscosity Range (without ) SUS(cst) 75-4000(15-800) 75-2500(15-500) 75-2500(15-500) 75-2500(15-500) 75-2500(15-500)Electrical Cable Length ft (m) 32 (10) 32 (10) 32 (10) 32 (10) 32 (10)Hose Length ft (m) 16 (5) 16 (5) 16 (5) 16 (5) 16 (5)Hose Material NBR NBR NBR NBR NBRInlet - Outlet G1 - G1/2 M52x2-M36x2 M52x2-M36x2 M52x2-M36x2 M52x2-M36x2Seal Material (FPM for operating fluid B, X) NBR NBR NBR NBR NBRDry Weight (lbs.) 665 940 970 1100 1145Fluid Temperature 50°F to 175°F 50°F to 175°F 50°F to 175°F 50°F to 175°F 50°F to 175°FAmbient Temperature 5°F to 105°F 5°F to 105°F 5°F to 105°F 5°F to 105°F 5°F to 105°FMax. Free Water Removal Rate* (gallons/hour) 0.5 0.75 1 1.5 2Attainable water content (ppm) <100 ppm <100 ppm <100 ppm <100 ppm <100 ppm

Technical Data:

For special models, please contact our sales/technical department *See next page for factors that affect water removal rate

Page 40: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable Filters

37

Saturation Limit of a Hydraulic Oil for Water

free and emulsified water

dissolvedwater

Negative Effects of Water on Oils:It is almost certain that there is water in a hydraulic system. The most frequent causes are: ambient humidity, splashwater, and new oil. Mineral based oils show a faster aging process, if there is water in the oil. This aging process is accel-erated through contamination particles by a catalytic effect. The additives are quickly used up and the lifetime of theoperating fluid is much shorter than that of "dry" oil.

Water in Mineral Oil causes:• Ageing of the fluid

• Fluid deterioration

- Reduced air separating results in: Cavitation

- Increased foaming results in: Cavitation

- Reduced lubrication results in: Vibration & Wear

- Erratic operation results in: Inaccuracy

• Depletes additives

• Clogged filters

Water in Ester Oils causes:• Hydrolysis

• Seal deterioration

• Leakage

FAM Sizing:Sizing of the FAM is normally donethrough periodic measuring of thewater content which will determinethe hourly ingestion of water. Thetypical dewatering speed of theFAM is listed in the technical datatable on page 2. If there is a con-tinuous ingression of water (i.e.condensation) the recommendedflow rate of the FAM can be deter-mined by the the system size (totalgallons.) It should circulate 3 or 4times through the FAM every day.

*Please note that the fluid temperatureshould be a minimum of 20°F warmer thanthe ambient air temperature to enable effi-cient dewatering. An inline heater is avail-able for reclaim applications. Please contactour sales/technical department.

Factors That Affect Water Removal RateFactor Dewatering

(increasing/decreasing) Speed

Water Content

Fluid Temperature*

Detergent Additives

Absolute Pressure in Vacuum Chamber

Humidity

FAM Flow Rate

Ester Oils

Sizing Chart(continuous water ingression)

Tank Volume FAM(gallons) Model

up to 1000 FAM 10

1000 to 2000 FAM 15

2000 to 4000 FAM 30

4000 to 7000 FAM 50

7000 and up FAM 70

tiny water droplets in hydraulic fluid(1 unit equals 10 micron)

Page 41: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Portable FIlters

381-877-GO HYDAC

Dimensions are for general information only.

64.96"1650mm

70.47"1790mm

27.56"700mm

24.41"620mm

38.58"980mm

21.65"550mm

69.02"1753mm

67.44"1713mm

M

M

HydraulicApplication

System

M

M

Filter

Level Sensors

Inlet

SolenoidValve

Stop

Stop Stop Outlet

Air Breather

VacuumRegulation

VacuumPump

VacuumChamber

PressureGauge

DrainPump

VacuumPump

Reactor

LevelSwitch

OptionalHeater

DrainPump

SolenoidControlValve

InletOutlet

AirInlet

VacuumAdjustment

Drawing and Dimensions:FAM 10 FAM 15 - 70 (without heater)

Water Extraction Process:(for FAM 15 - 70 without heater only)The operating fluid is drawn from the oil reservoir by the vacuum inthe reactor through the suction strainer and the shut-off valve. Theoil trickles down slowly and from there is fed back into the oil reservoirby the gear pump through the filter. When Dimicron filter elementtechnology is used the unit is especially economical.

Water is removed from the fluid in the reactor. The vacuum presenthas the effect of reducing the boiling point of the water.

The water vapor is released into the atmosphere or the water reservoirthrough the vacuum pump.

Hydraulic Symbol:FAM 10 FAM 15 - 70 without heater

M

M

Page 42: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Offline Filtration

39

Technical Data:

Hydraulic Circuit OF5 S:Pumping Out Without Filtration

Off-Line FIltration

Filling With Filtration

Hydraulic Circuit OF5 N:

Dimensions:

Max. Flow Rate 13 gpm

Operating Pressure 65 psi max.

Viscosity Range 75-4000 SUS

Permiss. Operating Fluid Mineral oil (other fluids on request)

Fluid Temperature 14° to 176° F

Ambient Temperature -4° to 104° F

Seals NBR (option FPM)

Safety Type IP 54

Weight approx. 102 lbs empty

7.32"186mm

8.43"214mm

14.65"372mm

15.75"400mm

6.69"170mm

17.52"445mm

35.04"890mm

33014.17"360mm

130024.80"630mm

260042.52"

1080mm

15.75"400mm

M

T A B

M

T A B

M

T A B

M

Filtromat OF5

Page 43: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Offline Filtration

401-877-GO HYDAC

Model Code:OF5 S 10 P 6 N 1 B 05 E

ModelOF5 -

TypeS = stationary with change-overN = stationary without change-over

Type Code10 = standard

SealsP = NBRV = FPM (Viton)

Motor Pump UnitCode flow rate max viscosity Electric motor output3 = 10 gpm 1250 SUS 0.75 kW6 = 13 gpm 4000 SUS 1.5 kW

Electric Motor VoltageM = 1 x 230 V - 50 HzN = 3 x 380-420 V - 50 Hz, 3 x 440-480 V - 60 Hz

Filter Size1 = for element size 3302 = for element size 13003 = for element size 2600

Filter MaterialP = paper (P/HC)B = Betamicron® (BN3HC)A = Aquamicron® (BN/AM), (AM)

Filtration Rating (micron) 03 = 3 µm05 = 5 µm Betamicron® Low Collapse10 = 10 µm20 = 20 µm

40 = 40 µm Auquamicron®

A03 = 3 µmA10 = 10 µm Betamicron®/Aquamicron® Combination (10 µm only available in size 2)

10 = 10 µmPaper

20 = 20 µm

Clogging Indicator

E = pressure gauge (standard)B = differential pressure indicator - visualC = differential pressure indicator - electricalD = differential pressure indicator - visual/electrical

Note: Options B, C, D are not available for type “N”

Page 44: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Offline Filters

41

Features and Benefits:The OLF series of filters is designed to efficiently and costeffectively filter hydraulic oils, lubricating oils, cleaning fluidsand coolants which are highly contaminated. The filters canbe supplied either as individual filters or as ready-to-installoffline units complete with optional motor and pump units.

• Lower Operating Costs

• Extended Element Service Life

• Cleaner, more efficient systems

Dimicron® Technology:Dimicron® technology, which incorporates membrane filtration and multi-disc construction, sets the OLF apartfrom conventional filters by providing it with exceptionaldirt holding capacity and separation efficiency. Each filterelement is able to capture and hold more than 1 pound ofdirt, meaning that the OLF60, which uses four elements,will hold nearly 5 pounds of dirt. Membrane filtration provides the OLF with a separation efficiency over 99.9%for particles 2 micron and larger (ß2 > 1000) even in a single pass.

Applications:Typical applications include:

• Filling and flushing hydraulic units

• Filtration of fluids for hydraulic systems and test stands

• Filtration of cleaning fluids for parts washing machines

• Filtration of coolants

Dimicron® Element:The synthetic membrane (2µm absolute) provides a high filtration rating while the cellulose filter layer collects andholds the bulk of the dirt load. This combination results inexcellent removal efficiency, even in a single pass, andextremely high dirt holding capacity.

Typical Cleanliness Improvement Using the OLF

Time (minutes)

without OLF with OLFIS

O -

Cla

ss

23/21

21/28

19/16

17/14

15/12

13/10

11/8

9/60 2 4 6 8 10 12 14 16 18 20

OLF series Offline Filtration

QQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQQ

CelluloseFilter Layer

SyntheticMembrane

DrainageStructure

SupportTube

Mobile Version Now Available.Consult HYDAC for Details!

Page 45: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Offline Filters

421-877-GO HYDAC

Model Code:OLF - 15 / 15 - S - L60 - N15DM002 - E / 12

SeriesOLF = Stationary offline filter with integrated pressure gauge

Size15 = 1 element30 = 2 elements45 = 3 elements60 = 4 elements

Pump Flow Rate (must be less than or equal to size)15 = 5 gpm30 = 10 gpm45 = 15 gpm60 = 20 gpmZ = without pump

Pump TypeS = vane pumpG = gear pumpW = centrifugal pumpZ = Without motor-pump

Motor VoltageL60 = 115V, Single PhaseO60 = 460V, Three PhaseZ = Without motor-pump

Filter ElementN15DM002 = Dimicron® 2 µm AbsoluteN15DM010 = Dimicron® 10µm AbsoluteN15DM020 = Dimicron® 20 µm AbsoluteN15DM030 = Dimicron® 30 µm Absolute

Clogging IndicatorE = Standard Integrated Pressure GaugeC = Differential Pressure Indicator - Electrical (VM2 C.0)F = Pressure Switch - Electrical (VR2 F.0)

Supplementary Details12 = SAE adapters (BSPP connections are standard)V = Viton® Seals (NBR seals are standard)MP = Integrated TestPoint for connection to FCU via Minimess Line

this code entry (15, 30, 45, 60)must be less than or equal to thesize code entry (15, 30, 45, 60)

Dimensions:

17.5"

27"OLF 15

64"OLF 60

52"OLF 45

40"OLF 30

24"

PressureGauge

InletHousingDrain

Outlet

8"

6"

Page 46: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Offline Filters

43

Technical Details:Connections (All Female)

Housing Inlet & Outlet: 1 5/16 - 12UN (SAE 16) G1*Pump Inlet:Model Vane Gear CentrifugalOLF-15 1 1/16 -12UN (SAE 12) G3/4 1 1/16 -12UN (SAE 12) G3/4 1 5/16 -12UN (SAE 16) G1OLF-30 1 5/8 -12UN (SAE 20) G1 1/4 1 5/16 -12UN (SAE 16) G1 1 5/16 -12UN (SAE 16) G1OLF-45, 60 1 5/8 -12UN (SAE 20) G1 1/4 1 7/8 -12UN (SAE 24) G1 1/2 1 5/8 -12UN (SAE 20) G11/4

Housing drain standard on all unitsBLACK = SAE connections when using adapters which are supplied standardRED = BSPP connections if supplied adapters are not used

OLF-15 OLF-30 OLF-45 OLF-60Filter Element N15DMxxx(1x) N15DMxxx(2x) N15DMxxx(3x) N15DMxxx(4x)

Contamination Retention Capacity 500g 1000g 1500g 2000g(1.1lbs) (2.2lbs) (3.3lbs) (4.4lbs)

Filter Efficiency ßx > 1000 ßx > 1000 ßx > 1000 ßx > 1000Permissible ∆p Across the Element (psi) 72.5 72.5 72.5 72.5Weight Element (lbs) 6.6 13.2 19.8 26.4Material of Filter Housing Stainless Steel Stainless Steel Stainless Steel Stainless SteelCapacity of Pressure Vessel (gallons) 5.25 10.50 15.75 20.5Max. Operating Pressure Filter Housing (psi) 87 87 87 87Material of Seals-Housing (standard) NBR NBR NBR NBRWeight Housing (lbs) 25 33 53 62Fluid Temperature in °F 15-175 15-175 15-175 15-175

Technical Details for Motor-Pumps Units 5gpm 10gpm 15gpm 20gpmOperating Pressure of the Pump (psi) 65 65 65 65Viscosity Range with Vane Pump (SUS) 75-2500 75-2500 75-2500 75-2500Viscosity Range with Gear Pump (SUS) 75-5000 75-5000 75-5000 75-5000Viscosity Range with Centrifugal Pump (SUS) 5-100 5-100 5-100 5-100Motor Capacity (watts)Vane Pump 370 W 570 W 1500 W 1500WGear Pump 370 W 570 W 1500 W 1500WCentrifugal Pump 370 W 570 W 1500 W 1500WWeight Vane Pump (lbs) 17 30 43 43Weight Gear Pump (lbs) 21 33 49 49Weight Centrifugal Pump (lbs) 33 33 55 55Material of Seals in Pumps (standard) NBR NBR NBR NBRAll details in this brochure are subject to technical modifications.

60

45

30

15

040003000200010000 5000

Viscosity (SUS)

Diff

eren

tial

Pre

ssur

e (p

si)

Differential Pressure at 5 gpm (single element)

N15DM020

N15DM02

N15DM030

N15DM010

Page 47: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Sizing Offline Filtration:The following calculations will help to approximate the attainable system cleanliness level when applying offline filtration.

Step 1: Select the approximate contamination ingression rate fromthe chart below. HYDAC quantitative investigations have yielded the following approximate figures.

Step 2: Make the correction required for offline filtration.The contamination input selected above must be multiplied by the factor:

Main System Flow Rate / Desired Offline Flow Rate

Note: Main system flow rate must be corrected for cycle time. For example, if the flow rate is 500 gpm, but only runs for20% of the system cycle, the main system flow rate would be 100 gpm. (500 gpm X 20%)

This yields the expression:

Contamination Factor = Contamination Input (µg/gal) x Main System Flow Rate (gpm)

Desired Offline Flow Rate (gpm)

Calculate the contamination factor using this expression.

Step 3: Determine the attainable cleanliness level. Locate the calculated contamination factor on the y-axis of the attachedgraph. Go to the right to find the intersection point on the curve corresponding to the desired absolute filter micron rating.Read the resulting attainable cleanliness level on the x-axis. (In case of dynamic flow through the offline filter, the attainablecleanliness level will be 2 to 3 times worse than indicated by the graph.)

Offline Filtration Sizing ExampleType of System: Heavy industrial press

Surroundings: Normal

Main System Flow Rate: 150 GPM

Desired Offline Flow Rate: 16 GPM (OLF 60)

Step 1: Using this criterion select the approximate contamination ingression rate from the chart above.

This yields a contamination input of 18 µg/gal based on a heavy industrial press with normal surroundings.

Step 2: Make the correction required for offline filtration.

Contamination Factor = 18 µg/gal x 150 gpm / 20 gpm = 135

Step 3: Determine the approximate attainable cleanliness level for each micron rating using the attached graph. If theattainable cleanliness level is not acceptable, the desired offline flow rate should be increased. The approximate attainablelevels for this example are as follows.

2µm - ISO 17/15/12

20µm - Between ISO 20/18/15 and ISO 21/19/16

Fluid Service Catalog

Offline Filters

441-877-GO HYDAC

CONTAMINATION INGRESSION (µg/gal)

TYPE OF SYSTEM SURROUNDINGS

CLEAN NORMAL POLLUTED

Closed circuit 1 3 5

Injection molding machine 3 6 9

Standard hydraulic system 6 9 12

Lubrication system 8 11 14

Mobile equipment 10 13 16

Heavy industrial press 14 18 22

Flushing test equipment 42 60 7820

20

20

20

20

10

10

10

10

10

3

1000

100

10

1

0.1

0.0112/10/7

13/11/814/12/9

15/13/1016/14/11

17/15/1218/16/13

19/17/1420/18/15

21/19/1622/20/17

3

3

3

5

5

2

2

25

Con

tam

inat

ion

Fact

or (

g/ga

l)

Maximum Attainable Cleanliness Level (ISO)

20

10

3

2 2 micron

5

20 micron

10 micron

3 micron

5 micron

LEGEND

Page 48: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Fluid Service

45

Operating RangeViscosity: (see pressure drop curves) to 700 SUS (OLF-5) / to 3000 SUS (OLF-5/15) / to 10,000 SUS (OLF-5/4)Operating Pressure: 45 PSI (3 bar) maxSuction Pressure: 11” Hg (-0.4 to 6 bar) maxInlet Pressure (Model with flow control valve): 145 PSI (10 bar) min / 725 PSI (50 bar) maxFluid Temperature: 32 to 175° F (0 to 80° C)Ambient Temperature: -4 to 104° F (-20 to 40° C)Seals: NBR (standard)Maximum Flow Rate: OLF-5 = 1.6 GPM / OLF-5/15 = 4.9 GPM / OLF-5/4 = 1.3 GPM

Fluids Standard Mineral Oils / Water/Oil based fluids (Minimum 40% Oil in Fluid)Consult Factory for Other Fluids

ElementsMedia: Dimicron - 2µm, 20µm / Water Removal - 2µm, 20µmNumber required: OLF-5, 5/15, and 5/4 = 1Dirt Holding Capacity (∆P = 36 psi [2.5 bar]): 200g ISO MTD (N5DM...) / 185g ISO MTD (N5AM...)Water Retention (∆P = 36 psi [2.5 bar]): Approximately 0.5 quarts (0.5 liters)Beta Ratio: ßx > 1000 (absolute value)Maximum ∆P: 45 PSI (3 bar)

Connections (All Female)OLF-5 with motor/pump: Inlet & Outlet: 3/4 - 16UNF (SAE 8) (BSPP G1/2)OLF-5/15 & 5/4: Inlet & Outlet: 1 5/16-12UN (SAE 16) (BSPP G1)OLF-5 without motor/pump: Inlet: 9/16-18UNF (SAE 6) (BSPP G3/8)

Outlet: 3/4-16UNF (SAE 8) (BSPP G1/2)Weight OLF-5-S (15.5 lbs. (7.0 kg) / OLF-5-E (5.5 lbs. (2.5 kg) / OLF-5/15 (24.3 lbs. (11 kg)

OLF-5/4 (24.3 lbs. (11 kg)

Technical Data:

OLF series Offline Filtration

Features:The OLF Compact filter is designed to be used offline toefficiently and cost effectively filter standard hydraulic oilswhich are highly contaminated. The OLF Compact isspecifically designed to be used on hydraulic systems witha reservoir volume of up to 1000 gallons. Please see sizingcalculation on back page. The standard filters can be suppliedas ready to install offline units complete with motor andpump units as shown or as individual filters.

Applications:Typical applications include:

• Injection molding machinery• Machine tools• Gear boxes• Mobile equipment• Filtration of fluids for intermittently operated hydraulic

systems and test stands

Benefits:• Lower operating costs• Extended element service life• Extended fluid life• Cleaner, more efficient systems• Incinerable elements• Easy installation

Housing drain standard on all unitsBlack = SAE connections when using adapters which are supplied as standardRed = BSPP connections if supplied adapters are not used

Page 49: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Offline Filters

461-877-GO HYDAC

Typical Cleanliness Improvement Using the OLF

Time (minutes)

without OLF with OLF

ISO

- C

lass

23/21

21/28

19/16

17/14

15/12

13/10

11/8

9/60 2 4 6 8 10 12 14 16 18 20

Model Code:OLF-5 - S - 120 - K - N5DM002 - E / 12

SeriesOLF-5 = Series 5 (1.6 gpm) OLF-5/15 = Series 15 (4.9 gpm)OLF-5/4 = Series 15 (1.3 gpm)

Pump TypeS = Vane Pump* (standard)E = Flow Control Valve (series 5 only)M = Mobile

Power Consumption120 = 120W for all OLF 5200 = 200W for all 12VDC and 24VDC370 = 370W for all Series 5/15 & 5/4Z = Without motor-pump unit (series 5 only)

VoltageT = 12VDCU = 24VDC K = 115V single phaseM = 220V single phase N = 220/440V 3 phaseZ = Without motor-pump unit

ElementN5DM002 = 2 micronN5DM020 = 20 micronN5AM002 = 2 micron with water removalN5AM020 = 20 micron with water removalM180B20 = 20 micron spin-on (series 5/4 only)

Clogging IndicatorE = Standard gauge (series 5 only)F = Static electrical switch VMF2F.0 (series 5 only)BM = Differential visual VM2BM.1 (series 5/15 & 5/4 only)C = Differential electrical VM2C.0 (series 5/15 & 5/4 only)D = Differential electrical/visual VM2D.0/L... (series 5/15 & 5/4 only)

Mechanical Connections12 = SAE Connections (standard)

Supplementary DetailsL24 = Lamp for 24 voltsL48 = Lamp for 48 volts D-Type CloggingL115 = Lamp for 115 volts Indicator OnlyL230 = Lamp for 230 volts

Consult Factory for special optionsNot all combinations available

*Choose “S” for model without motor-pump and without flow control valve.

ReplacementElement Model Codes

Betamicron®

2 µm N5DM002

20 µm N5DM020 or 180MA020BN (OLF-5/4 only)

Water Removal2 µm N5AM002

20 µm N5AM020

Page 50: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

0

2.5

10bar

11.890"(302)

9.961"(253)

.354"(9)

.394"(10)

538

413

2

6

7

5

8

2.913"(74) 1.457"

(37)

min 2.362" (60)

6.614"(168)

3.189"(81)

4.291"(109)

7.362"(187)

6.299"(160)

Fluid Service Catalog

Offline Filters

47

P

S

3.5 bar

M

P

S

M

VA

P

S

po =3.5 bar

Dimensions:

12.598"(320)

605

2

65

Ø 5.67"(Ø 144) 5.35"

(136)4.410"(112) Ø 0.276"

(Ø 7)

2.795"(71)

370-M370-K

8.31"(211)Max.

1

3

8

7

3.543"(90)

4.409"(112)

4.528"(115)

4

N5...

0

2.5

10bar

12.205"(310)

9.961"(253)

.354"(9)

.394"(10)

13.228"(336)

4

132

6

5

2.913"(74)

1.457"(37)

7.362"(187)

ca. 9.843"(250)

6.299"(160)

6.614"(168)

3.189"(81)

7.480"(109)

OLF-5-S-...

OLF-5/4-S-... and OLF-5/15-S...

OLF-5-E-...

12.76"(324)

016019.88"(505)

01606.89"(175)

018023.94"(608)

018011.06"(281)

2

Ø 5.512"(Ø 140) 5"

(127)4.410"(112) Ø 0.276"

(Ø 7)

2.795"(71)

7.283"(185)

4.488"(114)

1

3

8

7

7

3.543"(90)

4.409"(112)

4.528"(115)

(0160)

(0180)

OLF-5/4-SP-...

Key1 = Inlet 5 = Filter Bowl2 = Clogging Indicator 6 = Drain3 = Outlet 7 = Filter Element4 = Clamp 8 = Electric MotorDimensions are in inches (mm)

Page 51: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Offline Filters

481-877-GO HYDAC

Differential Pressure:

OLF-5-TAK:

OLF-5/4-...

OLF-5

Q (

gpm

)

Viscosity (SUS)15 200 7000

4

00 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 47.5 5042.5 45

1.0

2.0

3.0

4.0

5.0

6.0

Bar

l/min

SRV flow control valve curve Application

Tank capacity to approx. 200 gallons

Tank capacity to approx. 525 gallons

N5DM002

Viscosity (SUS)

Diff

eren

tial P

ress

ure

(PS

I)

45.04.9 gpm

1.66 gpm

1.36 gpm

37.5

30.0

22.5

15.0

7.5

0.00 2500 5000 7500 10,000

N5DM020

Viscosity (SUS)

Diff

eren

tial P

ress

ure

(PS

I)

4.9 gpm

1.66 gpm

1.36 gpm

37.5

30.0

22.5

15.0

7.5

0.00 2500 5000 7500 10,000

breather filter

ventalation

S

R

adapter

return hose

suction hose

Description:Use the OLF-5-TAK tank connection kit 2.0 toquickly mount bypass filter units on hydraulicinstallations. This component can be mountedon installations with ventilation filter whoseconnections conform to DIN 24557/T2.

Ordering Information:Model Code: OLF-5-TAK Part No.: 03039235

Page 52: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Replacement Elements

49

Be sure to order the correct number of elements:OLF 15 = 1, OLF 30 = 2, OLF 45 = 3, OLF 60 = 4

*Cartridge element can not be used with OLF 5/4-SP**Spin-on element for OLF 5/4-SP only

Model Code Micron Rating Media Type Part No.N15DM002 2 Dimicron® 01251590N15DM010 10 Dimicron® 03115180N15DM020 20 Dimicron® 00349576N15DM030 30 Dimicron® 03048790

OLF Offline Filters

FCM & Filtromat OF5

Model Code Micron Rating Media Type Part No.N5DM002* 2 Dimicron® 00349494N5DM020* 20 Dimicron® 03023508N5AM002* 2 Aquamicron® 00349677N5AM020* 20 Aquamicron® 03040345

180MA020BN** 20 Betamicron® 02059441

OLF Compact Offline Filters & FCC Filter Cart

1300R BN3HC 003 KB

Size0330R = size 330 return line element (Filtromat OF5 only)1300R = size 1300 return line element2600R = size 2600 return line element

Media TypeBN3HC = Betamicron®

AM = Aquamicron®

BN/AM = Betamicron®/Aquamicron® CombinationP/HC = Paper

Micron Rating003 = 3 µm005 = 5 µm010 = 10 µm020 = 20 µm040 = 40 µm

Bypass Valve(omit) = 43 psidKB = without bypassB6 = 87 psid

NOTE: not all combinations are available.

Page 53: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Replacement Elements

501-877-GO HYDAC

HYDAC offers a complete range of interchange elementsfor all major manufacturers. To quickly and easily searchfor an interchange for any manufacturer, please visit:

BN/AM filter elements are specifically designed to absorb water and achieve absolute filtration ofsolid particles from mineral oils, HFD-R oils, and rapidly biodegradable oils. A super absorberreacts with the water present in the fluid and expands to form a gel from which the water can nolonger be extracted even by increasing the system pressure. These filter elements do not removedissolved water below the saturation level of the hydraulic medium. Solid particle filtration (3 µm,10 µm absolute) is achieved due to the Betamicron® filter construction.For complete details please contact your HYDAC distributor.

Aquamicron® filter elements are specially designed to separate water from mineral oils. They areonly supplied in the dimensions of HYDAC return line filter elements from size 330 and larger.This means that they can be installed in all HYDAC filter housings from size 330 which are fittedwith return line filter elements.The increasing pressure loss in a filter element which is being saturated with water indicates, bymeans of standard clogging indicators, that it is time to change the element. When theAquamicron® technique is employed, particle contaminants are also separated from the hydraulicmedium as a by-product. This means that the Aquamicron® element doubles as a safety filter.The "filtration rating" is 40 µm absolute (ß40 ≥ 100 to ∆p = 3 bar).In order to guarantee the greatest efficiency, it is recommended that these elements be installed inan off-line recirculation loop configuration.For complete details please contact your HYDAC distributor.

Interchange Elements

Aquamicron® (AM)

Betamicron® / Aquamicron® (BN/AM)

0180MA BN 003

Size0160MA = size 160 spin-on element (OF7 only)0180MA = size 180 spin-on element (OF5-10 & 15 only)

Media TypeBN = Betamicron®

A = Aquamicron®

P = Paper

Micron Rating003 = 3 µm005 = 5 µm010 = 10 µm020 = 20 µm025 = 25 µm

NOTE: not all combinations are available.Refer to product model code charts to seewhich combinations are available for each.

Portable Filtration Units

Page 54: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Fluid Service Catalog

Other Products

51

HYDAC’s Hydraulic Division offers a line of air-cooled andwater-cooled conditioning units for both mobile and industrialapplications. Highly engineered heat exchangers providethese units with exceptional efficiency in a compact design.

Air-Cooled industrial units use AC fans, while the mobile unitsuse DC, or hydraulic drive fans. Industrial units are availablewith pump & filter to provide a complete conditioning unit.

Call HYDAC’s Hydraulic Division for more information:

630-545-0800

HYDAC has over 35 years of experience developing filtrationproducts. Extensive field research and an application drivendesign philosophy have lead to a complete line of filters.Our line ranges from small manifold cartridges (circuitprotectors) to huge return-line housings that handle flowsup to 3900 gpm.

Call HYDAC’s HYCON Division for more information:

877-464-9322

Reservior accessories produced by HYDAC’s HYCONDivision include breathers, filler breathers, fluid level indicatorsand suction strainers. Breathers prevent the ingression ofcontamination which is more 10 times more efficient thanhaving to remove it after entry to the system. Filler basketsprevent large contamination from entering the tank duringfilling. Suction strainers protect the pump from contaminationthat does enter the tank. Fluid level indicators which areavailable with electric level switches protect against low oillevels which could result in inefficient system operation andcomponent damage.

Call HYDAC’s HYCON Division for more information:

877-464-9322

Page 55: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

New Online Selector!

This new software is driven by a database that is constantly updated,so you know that you are viewing the most current data available. Itallows users to quickly perform searches by model code OR manu-facturer, and allows for the use of wildcards. This program alsoallows users to easily inquire about elements that are not listed.

Upgrade All Your Elements Today!Let HYDAC be your single source for all of your hydraulic and lube oil filter elements.Simplify purchasing and inventory while experiencing these benefits:

• High Dirt-Holding Capacities• Low Pressure Drops• High Efficiency Absolute Ratings• Great Cost to Value Ratio• Supported Mesh Packs• Global Availability

Fluid Service Catalog1-877-GO HYDAC

Page 56: Fluid Service Products - Airline Hydraulics HYDAC fluid service products as well as HYDAC filters, coolers, accumulators, and other products. As with all industrial hydraulics and

Bladder, Piston, & Diaphragm Types; Pulsation Dampeners & Shock Absorbers;Safety & Shut-off Blocks; Charging & Gauging Units; Mounting Components & Accessories

Hydraulic Oil; Lube Oil; Fuel & Fuel Oil; Water; Process;High Pressure; Return Line; Suction; Strainers; Inline; Manifold-mount; Modular Stacking;In-tank; Inside Tank; Circuit Protectors; Spin-on; Backflush; Selectable Duplex; Clogging Indicators;Wide Variety of Elements Including Interchanges for All Major Brands; Private Labeling for OEM’s

Offline & Portable Filters; Online & Portable Realtime Particle Counters; Water Sensors;Fluid Sampling Kits; Fluid Analysis Kits; Vacuum Dehydration Water Removal Units

High & Low Pressure Ball Valves; Flow, Needle, & Check Valves;Hydraulic/Pneumatic Actuators; Custom Valve Design

Hose, Tube, & Pipe Clamps; Cushion Clamps; Band Straps;U-bolts; Fixed Cylinder Clamps; Custom Clamping Solutions

TestPoints & Flexible Test Hoses; Fluid Level Indicators; Gauge Isolators;Suction Strainers; Breathers; Filler/Breathers; Desiccant Breathers

Pressure & Temperature Transducers & Switches; Flow Rate Meters;Current Probes; Digital Displays; Portable Data Recorders

Air-Cooled & Water-Cooled Models; Cooler, Pump/Filter, & Pump/Filter/Cooler Units;AC Industrial Models; DC & Hydraulic Drive Mobile Models

High Pressure & Compact Power Units;Standard & Custom Integrated Control Units

Pressure Controls — Reducing & Relieving Valves; Proportional Pressure & Flow Control Valves;Check Valves; Flow Controls; Load Controls — Counterbalance & Pilot-Op. Check Valves;Custom Manifold Design & Manufacturing; Solenoid Directional Valves — Poppet & Spool Types;5000 psi, up to 40 GPM; Inline Mounting Bodies

Central Valve Blocks; Suspension Control; Steering Control;Power Attachment Controls; Design & Application Assistance

© Copyright 2003, 2005 HYDAC TECHNOLOGY CORPORATION • HYCON Division2260 City Line Road • Bethlehem, PA 18017Phone: (610) 266-0100 • Fax: (610) 231-0445

Brochure - Fluid Service Products Catalog #02075860 / 06.05