FLOWJET PUMP FOR WELL TESTING
with DHG with MEFM
Pre
ssu
re a
nd
Te
mp
era
ture
Gro
ss r
ate
, w
ate
r h
old
up
, P
, T
Drill stem test with FlowJet pump
FLOWJET PUMP FOR PVT SAMPLING
Drill stem test with FlowJet pump
Me
mo
ry m
od
e P
VT
sam
ple
r
• PVT at different drawdown – purity
of sample
• Time, pressure programmable
• Inset with PVT tool retrievable by
slickline
• Volume of chamber 500cc
• Tool length 2m
• Tool OD 38mm
Ne
w p
erf
sa
dd
ed
Gh
aza
l, Z
arg
aB
ara
kA
rad
ieb
aWorkover success confirmation after perforation of new interval (green) below watered Ghazal. New zone
performed at 225m3/d and 40% WC. However, during welltest there was no backflow, all produced fluid went
to Ghazal-Zarga zone (depleted heavily). North Side tested all intervals commingled , i.e. New zone + Ghazal-
Zarga, (results shown at second test after red arrow). Gross was 240m3/d, WC 98%. No oil flow. Old interval
dominated during production test. It was recommended to the Client to shut-off Ghazal-Zarga formation,
cement squeeze was done. After cement squeeze well running by properly selected based on 1st test results ESP
at 250m3/d with 44% WC.
Drill stem test with FlowJet pump
FLOWJET PUMP CASE STUDY
Pressure build up
Bottom hole flowing pressure
FJP regimes change
Drill stem test with FlowJet pump
FLOWJET PUMP CASE STUDY
Pressure build up
Pressure build up
Bottom hole flowing pressure
Drill stem test with FlowJet pump
Well-X. FJP&MMFT. Packer setting depth 1200m. Testing intervals: 1469.5-1473.5, 1545-1548
mKB
P inj=120bar P inj=100barP inj=90bar P inj=80bar
Drill stem test with FlowJet pump
Regimes of FJP over time and average parameters at every
regime
Time laps dataTime Rate, m3/hr WC, % BHFP, bar T,deg C
17:00 9,6 90 43,2 63,3
18:00 12,5 97,4 58,5 66,7
19:00 12,4 97,6 73,9 68,6
20:00 12,8 98,3 75,2 68,9
21:00 13 98,7 79 69,1
22:00 13,1 97,8 80,4 69,2
23:00 12,4 98,6 84,8 69,2
0:00 12,4 97,8 85,4 69,2
0:30 12,4 97,6 85,7 69,3
Regime #1 . Power fluid pressure 120 bar.Parameters Min: Max: Average:
WC at the regime, %: 71,1 100 95,5
Flow rate, m3/hr 6,3 13,4 10,4
Pressure, bar 28 62,5 48
Temp, deg C 58,6 67,8 64,4
Regime #2 . Power fluid pressure 100 bar.Parameters Min: Max: Average:
WC at the regime, %: 94,1 99 97,3
Flow rate, m3/hr 10,97 13,4 12,6
Pressure, bar 71,4 75,7 74,35
Temp, deg C 67,96 69,05 68,7
Regime #3 . Power fluid pressure 90 bar.Parameters Min: Max: Average:
WC at the regime, %: 93,5 99,3 97,3
Flow rate, m3/hr 12,1 13,4 12,9
Pressure, bar 78,4 80,8 79,7
Temp, deg C 69 69,3 69
Regime #4 . Power fluid pressure 80 bar.Parameters Min: Max: Average:
WC at the regime, %: 92,8 98,6 96,9
Flow rate, m3/hr 11,8 12,8 12,4
Pressure, bar 83,7 85,8 85,1
Temp, deg C 69,2 69,3 69,23
Drill stem test with FlowJet pump
Well-X. FJP&MMFT. Packer setting depth 1200m. Testing intervals: 1460-1465 mKB
P inj=1740, 1885, 2000 psi
Wait for p stabilization
Drill stem test with FlowJet pump
Regimes of FJP over time and average parameters at every regime
Time laps dataTime Rate, m3/hr WC, % BHFP, bar T,deg C
10:40 0 60 0 56,6
11:40 0,2 60 0 59,3
12:40 0,2 50 0 59,4
13:40 0,1 50 0 59,4
14:40 0,1 50 0 59,4
15:35 0,1 50 0 59,5
Regime #1, 2, 3 . Power fluid pressure 1740, 1885, 2000 PSI.Parameters Min: Max: Average:
WC at the regime, %: 30,8 71,1 49,2
Flow rate, m3/hr 0 0,2 0,06
BHFP, bar 0 0 0
Temp, deg C 56,1 59,5 59,2
During a test where was almost no inflow from reservoir.
Drill stem test with FlowJet pump