http://northsidetools.com Drill stem test with FlowJet pump

Transcript of FlowJet pump North Side FZCnorthsidetools.com/wp-content/uploads/2017/10/Drill-stem-test-with... ·...

http://northsidetools.com

Drill stem test with FlowJet pump

FLOWJET PUMP FOR WELL TESTING

with DHG with MEFM

Pre

ssu

re a

nd

Te

mp

era

ture

Gro

ss r

ate

, w

ate

r h

old

up

, P

, T

Drill stem test with FlowJet pump

FLOWJET PUMP FOR PVT SAMPLING

Drill stem test with FlowJet pump

Me

mo

ry m

od

e P

VT

sam

ple

r

• PVT at different drawdown – purity

of sample

• Time, pressure programmable

• Inset with PVT tool retrievable by

slickline

• Volume of chamber 500cc

• Tool length 2m

• Tool OD 38mm

Ne

w p

erf

sa

dd

ed

Gh

aza

l, Z

arg

aB

ara

kA

rad

ieb

aWorkover success confirmation after perforation of new interval (green) below watered Ghazal. New zone

performed at 225m3/d and 40% WC. However, during welltest there was no backflow, all produced fluid went

to Ghazal-Zarga zone (depleted heavily). North Side tested all intervals commingled , i.e. New zone + Ghazal-

Zarga, (results shown at second test after red arrow). Gross was 240m3/d, WC 98%. No oil flow. Old interval

dominated during production test. It was recommended to the Client to shut-off Ghazal-Zarga formation,

cement squeeze was done. After cement squeeze well running by properly selected based on 1st test results ESP

at 250m3/d with 44% WC.

Drill stem test with FlowJet pump

FLOWJET PUMP CASE STUDY

Pressure build up

Bottom hole flowing pressure

FJP regimes change

Drill stem test with FlowJet pump

FLOWJET PUMP CASE STUDY

Pressure build up

Pressure build up

Bottom hole flowing pressure

Drill stem test with FlowJet pump

Well-X. FJP&MMFT. Packer setting depth 1200m. Testing intervals: 1469.5-1473.5, 1545-1548

mKB

P inj=120bar P inj=100barP inj=90bar P inj=80bar

Drill stem test with FlowJet pump

Regimes of FJP over time and average parameters at every

regime

Time laps dataTime Rate, m3/hr WC, % BHFP, bar T,deg C

17:00 9,6 90 43,2 63,3

18:00 12,5 97,4 58,5 66,7

19:00 12,4 97,6 73,9 68,6

20:00 12,8 98,3 75,2 68,9

21:00 13 98,7 79 69,1

22:00 13,1 97,8 80,4 69,2

23:00 12,4 98,6 84,8 69,2

0:00 12,4 97,8 85,4 69,2

0:30 12,4 97,6 85,7 69,3

Regime #1 . Power fluid pressure 120 bar.Parameters Min: Max: Average:

WC at the regime, %: 71,1 100 95,5

Flow rate, m3/hr 6,3 13,4 10,4

Pressure, bar 28 62,5 48

Temp, deg C 58,6 67,8 64,4

Regime #2 . Power fluid pressure 100 bar.Parameters Min: Max: Average:

WC at the regime, %: 94,1 99 97,3

Flow rate, m3/hr 10,97 13,4 12,6

Pressure, bar 71,4 75,7 74,35

Temp, deg C 67,96 69,05 68,7

Regime #3 . Power fluid pressure 90 bar.Parameters Min: Max: Average:

WC at the regime, %: 93,5 99,3 97,3

Flow rate, m3/hr 12,1 13,4 12,9

Pressure, bar 78,4 80,8 79,7

Temp, deg C 69 69,3 69

Regime #4 . Power fluid pressure 80 bar.Parameters Min: Max: Average:

WC at the regime, %: 92,8 98,6 96,9

Flow rate, m3/hr 11,8 12,8 12,4

Pressure, bar 83,7 85,8 85,1

Temp, deg C 69,2 69,3 69,23

Drill stem test with FlowJet pump

Well-X. FJP&MMFT. Packer setting depth 1200m. Testing intervals: 1460-1465 mKB

P inj=1740, 1885, 2000 psi

Wait for p stabilization

Drill stem test with FlowJet pump

Regimes of FJP over time and average parameters at every regime

Time laps dataTime Rate, m3/hr WC, % BHFP, bar T,deg C

10:40 0 60 0 56,6

11:40 0,2 60 0 59,3

12:40 0,2 50 0 59,4

13:40 0,1 50 0 59,4

14:40 0,1 50 0 59,4

15:35 0,1 50 0 59,5

Regime #1, 2, 3 . Power fluid pressure 1740, 1885, 2000 PSI.Parameters Min: Max: Average:

WC at the regime, %: 30,8 71,1 49,2

Flow rate, m3/hr 0 0,2 0,06

BHFP, bar 0 0 0

Temp, deg C 56,1 59,5 59,2

During a test where was almost no inflow from reservoir.

Drill stem test with FlowJet pump

LAS FORMAT OF THE DATA

Drill stem test with FlowJet pump