FLOW INVESTIGATION IN A TWO-PASS COOLANT CHANNEL WITH ... · PDF fileFLOW INVESTIGATION IN A...
Transcript of FLOW INVESTIGATION IN A TWO-PASS COOLANT CHANNEL WITH ... · PDF fileFLOW INVESTIGATION IN A...
Sixteenth International Symposium on Air Breathing EnginesAugust 31- September 5, 2003, Cleveland, Ohio, USA
1
FLOW INVESTIGATION IN A TWO-PASS COOLANT CHANNELWITH/WITHOUT RIBBED WALLS
Dr.-Ing. Marc P. JARIUS and Dipl.-Ing. Martin ELFERTGerman Aerospace Center
Institute of Propulsion TechnologyD-51170 Köln, Germany
Fax Number: +49 2203 64395,E-mail address: [email protected], [email protected]
KEY WORDS: MULTI-PASS COOLANT CHANNEL, PARTICLE-IMAGE VELOCIMETRY, CFD
VALIDATION, WALL FLOW VISUALIZATION.
ABSTRACT
The aero-engine industry and the power generation industry operate in a highly competitive market.
Therefore high requirements in terms of high technology development as well as cost and development
times reduction are constant major objectives. On the other hand, environmental and safety constraints are
an increasingly stringent necessity, which enforces the demand for new technologies. Currently, the
industry relies on expensive and time consuming rig test programs, whereas the existing numerical design
tools have a number of deficiencies in accurately describing the complex multi-pass coolant channel flow.
Under these conditions the Institute of Propulsion Technology at DLR is involved in national and European
research programs aimed to provide the industry with high quality experimental data from the flow field for
CFD validation.
In past projects the flow behaviour in rotating passages was analysed at DLR using wall pressure
measurements to obtain the pressure drop. In addition, Laser-2-Focus velocimetry (L2F) was used to obtain
flow velocity components and fluctuations. Although time-consuming, this non-intrusive, single-point
measurement technique worked very well within straight and smooth duct flows, which generally have a
moderate degree of turbulence. However, state of the art, serpentine shaped, multi-pass systems (Figure A)
are equipped with ribbed walls, in order to improve heat exchange which is typical in realistic
configurations. In this case L2F velocimetry was not able to measure accurate flow properties due to the
increased turbulence intensities in the vicinity of the ribs as in the bend region and further downstream. The
dividing wall separating the two passages forces the flow into a sharp turn which generally results in a flow
separation. The flow within the separation bubble itself is very unsteady.
Modern planar measurement techniques such as particle image velocimetry (PIV) are capable of obtaining
complete maps of flows even at high turbulence. As a first step toward applying this technique, a multi-
pass cooling system is investigated in stationary (e.g. non-rotating) mode using two-component PIV. Two
types of models were investigated: model (a) with smooth walls, model (b) with ribbed walls. The PIV
2
results are compared to some visualisation results of wall streamlines and throughflow as secondary flow
development and 3D NS CFD results.
The high quality of the obtained results encourage the application of the two-component PIV to the rotating
system. As a logical consequence, the application of three-component PIV will be necessary to obtain the
complete flow field information within the complex flow passages.
Figure A. Schematic and transparent view of the test model geometry without ribbed walls
25°
20°
35°
8°
30° axis of rotation
1.0d
0.3d
dh = hydraulic diameter of the first pass
3∗
4
2
4∗
2∗
31∗
1
1.3d
Inlet Outlet
7.1
d0.
8 d 0.1 d
8 d
0.3d2 d
3
RESULTS
With regard to PIV processing, standard cross correlation algorithms were used with an interrogation
window size of 32 x 32 pixel and a 50 % overlap. The velocity of the intake flow into the first pass
amounts to v0 = 30.5 m/s, and consequently the REYNOLDS number is about 50.000 for the PIV
measurements. The measured flow field of the secondary flow within the second pass in four cuts for a
REYNOLDS number of 25.000 are shown in Figure B.
Figure B. Secondary flow velocity distribution in four cross cuts of the second pass measured with PIV(Re=25.000)
Figure C shows the streamline patterns and the velocity distribution on the leading wall of the duct,
obtained from oil flow visualization experiments, in comparison with a numerical solution and a PIV
measurement close to the wall.
x in mm
yin
mm
0 5 10 15 20 25 30 350
5
10
15
x in mm
yin
mm
0 5 10 15 20 25 30 350
5
10
15
x in mmy
inm
m0 5 10 15 20 25 30 35
0
5
10
15
x in mm
yin
mm
0 5 10 15 20 25 30 350
5
10
15
4
Figure C. Comparison between PIV, calculated and visualized wall velocities and streamlines on leadingwall, non-rotating
SUMMARY
This paper describes experimental investigations of a typical two-pass cooling channel system of a turbine
blade with and without ribbed walls with respect to fluid flow phenomena affected by geometry effects. A
complex flow situation is present showing several kinds of separation and vortices. In order to give an
accurate value of the turbulence level more than 2000 instantaneous PIV images will to be taken and
evaluated. To collect such a relatively high number of images it requires relatively high storage capacity.
The performed flow visualization and simulation are very helpful in that case to understand the interaction
of all apparent effects. The presented experiments were mainly intended to assess the feasibility of applying
PIV in a multi-pass cooling channel used for applied cooling research. The results will show that it is
possible to apply PIV at a multi-pass cooling channel also with ribs. The application of PIV is approved
and will be adopted to the rotating system in the near future.
x in mm5 10 15 20 25 30 35
50
55
60
65
70
75
80
85
zin
mm
210
215
220
225
230
235
240
245
v in m/s: 2 4 6 8 10 12 14 16 18 20 22 24
170
175
180
185
190
195
200
205
130
135
140
145
150
155
160
165
90
95
100
105
110
115
120
125