Flood Light FL2C Series Features - Maser Australia · Flood Light FL2C Series Features ... Light...
Transcript of Flood Light FL2C Series Features - Maser Australia · Flood Light FL2C Series Features ... Light...
Specifications Flood Light FL2C Series
Features ¾ Flip-chip technology, single unit’s damage won't affect other units’ normal
work; ¾ IP68 LED optical engine, highest waterproof rating, screw-free design; ¾ Multiple light distributions available; ¾ Intelligent constant current driver, long life span; ¾ Quick waterproof connectors; ¾ Easy installation and maintenance; ¾ Die-cast aluminum housing; ¾ Adjustable range ±360 Degree
Applications ¾ Facade and building lighting ¾ Factory lighting ¾ Area & Storage lighting
¾ Parking Lot
Advantages
Air Convection Effect Whole-structure Heat Dissipation
Double-coupling IP68 Protection Tool-less Maintenance
High-efficacy LED Light Source Flexible Combinations of Modules
Specifications Flood Light FL2C Series
Electrical & Photometric
Model
Input
Voltage
(v)
Drive
Current
(mA)
Power
(w)
Luminous
Efficacy
(lm/w)
Lumens
(lm)
Power
Factor
Power
Efficiency
Light Distributions LED
Brand
CCT
(k) CRI
M1A & M2A M8B
FL2C-1
AC100-277
700 40 110 ± 5 4400±200
0.95 91%
Beam Angle
(50%)
12°
25°
40°
60°
110°
Beam Angle
(50%)
25°
40°
60°
110°
Lumileds
3000
③
4000
5000
5700
>70
860 50 105 ± 5 5250±250
1050 60 100 ± 5 6000±300
FL2C-2
700 80 110 ± 5 8800±400
860 100 105 ± 5 10500±500
1050 120 100 ± 5 12000±600
FL2C-3
700 120 110 ± 5 13200±600
860 150 105 ± 5 15750±750
1050 180 100 ± 5 18000±900
FL2C-4
700 160 110 ± 5 17600±800
860 200 105 ± 5 21000±1000
1050 240 100 ± 5 24000±1200
FL2C-5
700 200 110 ± 5 22000±1000
860 250 105 ± 5 26250±1250
1050 300 100 ± 5 30000±1500
FL2C-6
700 240 110 ± 5 26400±1200
860 300 105 ± 5 31500±1500
1050 360 100 ± 5 36000±1800
FL2C-7 700 280 110 ± 5 30800±1400
860 350 105 ± 5 36750±1750
*Surge Protection: 10KV. *Input voltage 100-277VAC, operating frequency 50-60Hz, THD<20%.
Mechanical & Environmental Model
Working
Environment
Storage
Temperature
Lumen
Maintenance
Housing
Material
Protection
for Break
Product
Dimensions
(mm)
Outer Carton Size
(mm)
N.W
(kg)
G.W
(kg)
FL2C-1
-40℃~+50℃,
10%~90%RH. -40℃~+50℃ >50,000
Aluminum
Alloy 10KV
360*200*95 430*265*150 3.2 4.1
FL2C-2 360*200*175 430*265*230 4.7 5.7
FL2C-3 360*260*255 430*335*330 5.6 6.6
FL2C-4 360*260*335 475*430*210 6.7 8
FL2C-5 360*360*415 615*430*210 8.4 9.9
FL2C-6 360*360*495 660*430*210 9.4 11.1
FL2C-7 360*360*575 695*430*210 10.1 11.6
*IP68 LED Optical Module.
Warranty 5-year limited warranty is standard on luminaire and components.
Specifications Flood Light FL2C Series
Light Distributions M1A Module
25D1725 40D1540 60D1560 Beam Angle (50%) 25DEG Beam Angle(50%) 40DEG Beam Angle (50%)60DEG
00D1010 T5S3040
Beam Angle(50%) 110DEG Beam Angle(50%) 100x30DEG
Specifications Flood Light FL2C Series
M2A Module
12D1908 25D3725 40D3540 Beam Angle (50%) 12DEG Beam Angle(50%) 25DEG Beam Angle(50%) 40DEG
60D3560 11D3030
Beam Angle (50%)60DEG Beam Angle(50%)110x40DEG
Specifications Flood Light FL2C Series
M8B Module
25D1325 40D5340 60D2360 Beam Angle (50%) 25DEG Beam Angle (50%) 40DEG Beam Angle(50%) 60DEG
120D1390 LBN1310
Beam Angle(50%) 120x100DEG Beam Angle (50%)110DEG
Specifications Flood Light FL2C Series
External Design Features
Optical LED Engine IP68 rating
Optical Lens Multiple light distributions
Adjustable Bolt ±360 degree
Mounting Bracket ±360°adjustable
Driver Cover
Side Beam Aluminum alloy
Specifications Flood Light FL2C Series
Internal Design Features
Waterproof Connectors IP68 rating
LED Driver IP67 rating
Specifications Flood Light FL2C Series
Dimensions
FL2C -1 -2 -3 -4 -5 -6 -7
L 95mm (3.74”)
175mm (6.89”)
255mm (10.04”)
335mm (13.19”)
415mm (16.34”)
495mm (19.49”)
575mm (22.64”)
W 360 mm(14.17”)
H 200 mm (7.87”)
200 mm (7.87”)
260 mm (10.24”)
260 mm (10.24”)
360 mm (14.17”)
360 mm (14.17”)
360 mm (14.17”)
Specifications Flood Light FL2C Series
Installation
1. Fix the luminary onto the mounting surface with two M10 screws at the bracket.
2. Connect the ground wire, neutral wire and live wire to the AC input (make sure it
sufficiently grounded).
3. Loosen the M8x20 screws at bracket joint, adjust the
mounting angle. Then tighten up the screws at
bracket joint
4. Installation finished.
Maintenance Driver & Electrical Parts
1. Disconnect the luminary
from AC power. Unscrew the screws to remove the driver
cover.
2. Unscrew the screws to open the back cover.
3. Disconnect the connectors for the driver.
4. Unscrew the screws at the ends of the driver set, and
replace with a new set.
5. Fixate the new driver set with the screws and tighten
up.
6. Connect the new driver to modules and tighten up the
connectors.
7. Tighten up the mounting screws for the new driver, surge protector and the
cable clip.
8. Fix the driver cover back and tighten up the screws.
Specifications Flood Light FL2C Series
Module
1.Unscrew the screws on the
main beam covers at both sides and remove the two
main beam covers.
2. Unscrew the screws at both ends of the failed
module.
3. Plug out the module.
4. Disconnect the failed module from female
connector and replace it with a new one.
5. Connect and tighten up the waterproof connectors.
6. Install and fixate the module with the screws.
7. Close the main beam covers on both sides and tighten up the screws on
them.
Specifications Flood Light FL2C Series
Connectors Operation Guide
Spin the male terminal clockwise. When the male indicatrix points between indicatrix female #2 and #3, and the gap between male and female terminals is extremely small, the connectors are well connected; otherwise, there will be risks in its waterproof performance. When the gap between male and female terminals is extremely small, if any looseness can be sensed, please spin the male terminal clockwise until male indicatrix points between female #3 and #4.
Specifications Flood Light FL2C Series
Ordering Information Example: FL2CS-2-120-BK-M1L-1725-7-40-PH
Ordering
Information
FL 2C S - 2 - 120 BK - M1 L 1725 - 7 40 - PH
1 2 3 4 5 6 7 8 9 10 11 12
1. Luminary Type T: Street light TS: Tunnel light TF: High bay light FL: Flood light GL: Garden light
2. Luminary Series 1A 1B 1D 1F 2A 2C 3A 3B ……
3. Driving Current Blank/N: ≤700mA S: >700mA
4. Module Qty N: Non-modular luminary 1: 1 module 2: 2 modules 3: 3 modules 4: 4 modules ……
5. System Power 10: 10W 20: 20W 30: 30W 40: 40W 50: 50W ……
6. Housing Color BK: Black WH: White GY: Grey SR: Silver BU: Blue
BUWH: Blue top & White base BUGY: Blue top & Grey base OTH: Other
7. Module Series Blank: Non-modular luminary M1: M1 module M2: M2 module M5: M5 module ……
8. LED Brand L: LUMILEDS C: CREE O: OSRAM N: NICHIA S: SAMSUNG OTH: Other
9. Lens Code 1513 3100 3702 3910 2701 5703 3040 5703 3040 ……
10. CRI 6: ≥60 7: ≥70 8: ≥80 9: ≥90 OTH: Other
11. CCT 30: 3000K 40: 4000K 50: 5000K 57: 5700K
12. Driver Brand M0: MOSO MW: MEAN WELL PH: PHILIPS IN: INVENTRONICS AD: ADAYO OTH: Other
*Ordering information is for reference only. Some product configurations are not available. Please consult Specifications for specific product availability and for further
details.