Floating Solar
-
Upload
anish-babu -
Category
Documents
-
view
215 -
download
0
Transcript of Floating Solar
-
7/27/2019 Floating Solar
1/2
Any Company
Any Street 21
54321 Any Town
Tel.: +49 123 456-0
Fax: +49 123 456-100
E-Mail: [email protected]
Internet: www.any-company.de
Any Company Any Street 21 54321 Any Town
CIAL Infra
CIAL Golf Course
1
Location: India / Kochi
Grid voltage: 3~240 V
Project name:
Project number:
Project file:
System overview
6251 x BP Solar BP 3160N (PV array 1)Azimuth angle: 0, Inclination: 17, Mounting type: Free installation, PV peak power: 1.00 MWp
133 x STP 8000TL-20
Technical data
Total number of PV modules: 6251
PV peak power: 1.00 MWpNumber of inverters: 133
Nominal AC power: 1.06 MW
AC active power: 1.06 MW
Active power ratio: 106.4 %
Annual energy yield (approx.)*: 1571.04 MWh
Energy usability factor: 100 %
Performance ratio (approx.)*: 84.9 %Spec. energy yield (approx.)*: 1571 kWh/kWp
Line losses (in % of PV energy): 0.61 %
Unbalanced load: 0.00 kVA
Self-consumption: ---
Self-consumption quota: ---
*Important: The yield values displayed are estimates. They are determined mathematically. SMA Solar Technology AG accepts no responsibility for the realyield value which can deviate from the yield values displayed here. Reasons for deviations are various outside conditions, such as soiling of the PV Modules orfluctuations in the efficiency of the PV modules.
Sunny Design 2.30.0.R
Signature
1 / 2
-
7/27/2019 Floating Solar
2/2
Project name: CIAL Golf Course
Project number: 1
Project file:
Location: India / Kochi
Record Low Temperature: 7.00 C
Average High Temperature: 31.00 C
Record High Temperature: 33.00 CPart project 1
Ambient temperature:
Evaluation of design
133 x STP 8000TL-20
PV peak power:
Total number of PV modules:
Number of inverters:
Max. DC power (cos = 1):
Max. AC active power (cos = 1):
Grid voltage:
Nominal power ratio:
Displacement power factor cos :
1.00 MWp
6251
133
8.20 kW
8.00 kW
240 V
109 %
1 STP 8000TL-20
Technical data
Max. PV voltage:
Min. DC voltage (Grid voltage 240 V):
Number of strings:
PV modules per string:
Peak power (input):
Min. PV voltage:
Typical PV voltage:
Max. DC voltage (PV):
Max. current of PV array:
Max. DC current:
Input A: PV array 1
36 x BP Solar BP 3160N, Azimuth angle: 0, Inclination: 17, Mounting type: Free installation
Input B: PV array 1
11 x BP Solar BP 3160N, Azimuth angle: 0, Inclination: 17, Mounting type: Free installation
848 V
Input A:
2
18
5.76 kWp
552 V
569 V
150 V
1000 V
9.1 A
15.0 A
518 V
Input B:
1
11
1.76 kWp
337 V
348 V
150 V
1000 V
4.6 A
10.0 A
PV/Inverter compatible
Sunny Design 2.30.0.R
2 / 2