Floating Solar

download Floating Solar

of 2

Transcript of Floating Solar

  • 7/27/2019 Floating Solar

    1/2

    Any Company

    Any Street 21

    54321 Any Town

    Tel.: +49 123 456-0

    Fax: +49 123 456-100

    E-Mail: [email protected]

    Internet: www.any-company.de

    Any Company Any Street 21 54321 Any Town

    CIAL Infra

    CIAL Golf Course

    1

    Location: India / Kochi

    Grid voltage: 3~240 V

    Project name:

    Project number:

    Project file:

    System overview

    6251 x BP Solar BP 3160N (PV array 1)Azimuth angle: 0, Inclination: 17, Mounting type: Free installation, PV peak power: 1.00 MWp

    133 x STP 8000TL-20

    Technical data

    Total number of PV modules: 6251

    PV peak power: 1.00 MWpNumber of inverters: 133

    Nominal AC power: 1.06 MW

    AC active power: 1.06 MW

    Active power ratio: 106.4 %

    Annual energy yield (approx.)*: 1571.04 MWh

    Energy usability factor: 100 %

    Performance ratio (approx.)*: 84.9 %Spec. energy yield (approx.)*: 1571 kWh/kWp

    Line losses (in % of PV energy): 0.61 %

    Unbalanced load: 0.00 kVA

    Self-consumption: ---

    Self-consumption quota: ---

    *Important: The yield values displayed are estimates. They are determined mathematically. SMA Solar Technology AG accepts no responsibility for the realyield value which can deviate from the yield values displayed here. Reasons for deviations are various outside conditions, such as soiling of the PV Modules orfluctuations in the efficiency of the PV modules.

    Sunny Design 2.30.0.R

    Signature

    1 / 2

  • 7/27/2019 Floating Solar

    2/2

    Project name: CIAL Golf Course

    Project number: 1

    Project file:

    Location: India / Kochi

    Record Low Temperature: 7.00 C

    Average High Temperature: 31.00 C

    Record High Temperature: 33.00 CPart project 1

    Ambient temperature:

    Evaluation of design

    133 x STP 8000TL-20

    PV peak power:

    Total number of PV modules:

    Number of inverters:

    Max. DC power (cos = 1):

    Max. AC active power (cos = 1):

    Grid voltage:

    Nominal power ratio:

    Displacement power factor cos :

    1.00 MWp

    6251

    133

    8.20 kW

    8.00 kW

    240 V

    109 %

    1 STP 8000TL-20

    Technical data

    Max. PV voltage:

    Min. DC voltage (Grid voltage 240 V):

    Number of strings:

    PV modules per string:

    Peak power (input):

    Min. PV voltage:

    Typical PV voltage:

    Max. DC voltage (PV):

    Max. current of PV array:

    Max. DC current:

    Input A: PV array 1

    36 x BP Solar BP 3160N, Azimuth angle: 0, Inclination: 17, Mounting type: Free installation

    Input B: PV array 1

    11 x BP Solar BP 3160N, Azimuth angle: 0, Inclination: 17, Mounting type: Free installation

    848 V

    Input A:

    2

    18

    5.76 kWp

    552 V

    569 V

    150 V

    1000 V

    9.1 A

    15.0 A

    518 V

    Input B:

    1

    11

    1.76 kWp

    337 V

    348 V

    150 V

    1000 V

    4.6 A

    10.0 A

    PV/Inverter compatible

    Sunny Design 2.30.0.R

    2 / 2