Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1....

8
Flat LED Par Can Light EDD-GL-200 USER MANUAL

Transcript of Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1....

Page 1: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you

Flat LED Par Can LightEDD-GL-200

USER MANUAL

Page 2: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you
Page 3: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you

1. IntroductionThank you for purchasing our Million Color Flat LED light. Please read these instructions carefully before operating to avoid any possible damage and accidents caused by misuse.

The Million Color Flat LED light has a solid steel body. Three colors of high-brightness LED lights (red, blue, green) are used to create a wide spectrum of colors. It draws low power, has a low profile, dual mounting yokes in the handle and is low weight. The DMX controls include dimming, strobe, sound activation and independent control of RGB. The unit is compatible with the standard DMX 512 signal for external DMX control. Practical uses of the product include dance halls, stage backgrounds, hotels, large-scale performances, drapery uplighting and stage lighting.

Packing List

- Million color flat LED light- Power cable- User manual- Warranty card

2. Safety Information

- Please consult skilled service technicians for any repairs required- Always disconnect from the power source before setting up, moving and

servicing- Avoid direct eye contact to the light when in operation- Make sure the power supply voltage is compatible with this light- Before installation, please check the light’s fasteners and mechanical

structure is in good condition and not damaged- The light is designed for indoor use, below 40 degrees celsius- The fixture may be mounted in any position provided there is adequate

room for ventilation. Make sure there are no flammable and explosive items within 0.5 meters.

- Please ensure the ground is always connected

3

www.EddylightCo.com 1-800-914-3538

Page 4: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you

3. Dimensions and Specifications

Beam Angle: 21°, Field Angle: 32°Weight: 4 lbs/1.8 kg

Lamp: 183 UV high-power 10mm LEDsLamp Life: 100,00 hours

Dimensions:

8.0”

8.0”

3.0”

Page 5: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you

4. DMX Channel Assignment

Channel DMX Value Function Notes

1 0-255 Red dimming0—100%

Invalid while CH8 is 51-255

2 0-255 Green dimming0—100%

Invalid while CH8 is 51-255

3 0-255 Blue dimming0—100%

Invalid while CH8 is 51-255

4 0-255 Amber dimming0—100%

Invalid while CH8 is 51-255

5 0-255 RGB dimming0—100%

Invalid while CH8 is 51-255

6 0-255 Strobe speed7 0-255 Speed control

8

0-50 Solid color

851-100 Color cycling

8 101-150 Color fading8151-200 Color chase

8

201-255 Sound activated

5. Rear Panel Display and Operation

5

www.EddylightCo.com 1-800-914-3538

LED Display

Menu Up Down Enter

Selection buttons

DMX OUT DMX IN

DMX input/output Power in/out

120V AC OUT 120V AC IN

Page 6: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you

MENU: Access the menu or return to a previous menu optionUP: Menu selection or parameter incrementsDOWN: Menu selection or parameter incrementsENTER: Select the current menu option

6. Instructions for Manual ProgrammingMENU items:

•  ”d”: DMX mode (001-512) •  “CC”: Color change mode (speed: 0-99)•  “CP”: Color pulse mode (speed: 0-99)•  ”dE”; Built-in (default) program speed change mode (speed: 0-99) •  ”bE”; Sound (beat) activated (sensitivity: 0-99)• “r”; Red color setting (brightness: 0-255)• “g”; Green color setting (brightness: 0-255)• “b”; Blue color setting (brightness: 0-255)• “a”; Amber color setting (brightness: 0-255)

Press MENU to enter the main menu, and use UP/DOWN to cycle through the different modes. Press ENTER to select the desired mode, and UP/DOWN buttons to cycle through the different mode values (ie. 0-99, etc). Press ENTER to select that value and save your selection.

When powering up the unit, you will enter the menu mode previously saved.

For example, to Enter DMX mode, operate as follows:

• Press MENU repeatedly until “d001” • Press UP / DOWN to select your desired address (ie. “d017”)• Press ENTER to choose.

Page 7: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you

7. Color Selection Guide:Set the RGBA values using MENU on the back of the unit, or by using the DMX control board. Experiment with the different values to create different colors (ie. adding more Green to Red will make the red more orangey).

Color Name Red Green Blue Amber

  Red 255 0 0 0

  Green 0 255 0 0

  Blue 0 0 255 0

  Amber 0 0 0 255

  White 255 255 255 255

  Yellow 255 255 0 0

  Magenta 255 0 255 0

  Cyan 0 255 255 0

  Champagne 0 0 0 255

  Cold White 255 255 255 0

  Warm White 255 255 255 255

7

www.EddylightCo.com 1-800-914-3538

Page 8: Flat LED Par Can - EddyLighteddylight.com/wp-content/manuals/Flat LED Par Can 2015.pdf · 2018. 1. 12. · Flat LED Par Can Light EDD-GL-200 USER MANUAL. 1. Introduction Thank you

8. Cable ConnectionA standard XLR connection is used for the DMX 512 protocol:

Note: DMX512 does not include automatic error checking and correction, and so is not an appropriate control for hazardous applications, such as pyrotechnics or movement of theatrical rigging. False triggering may be caused by electromagnetic interference, static electricity discharges, improper cable termination, excessively long cables, or poor quality cables.

Note: In order to avoid failures and signal interference, it is recommended to connect a 120Ω resistor (1/4W) at the end of the DMX connection as shown on right. If using 5-pin DMX, please use a 5-pin to 3-pin cable adapter. Details on configuration below: