FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R....
-
Upload
mervin-boone -
Category
Documents
-
view
216 -
download
0
Transcript of FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R....
FLAO Interface Control Document
Presented by A. Riccardi
S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni
FLAO system external review, Florence, 30/31 March 2009
ICD structure
• Described interfaces for W@LBT and LBT672:– Mechanical– Optical– Cooling– Electrical power and signals– Network– Real time communication
• SW interfaces in a different document
FLAO system external review, Florence, 30/31 March 2009 2
Overview of connections
FLAO system external review, Florence, 30/31 March 2009 3
LBT672:M2 unit in Hub
LBT672:Spider-arm cabinet
W@LBT: AGW unit
Overview of physical connections
FLAO system external review, Florence, 30/31 March 2009 4
Power lines (120VAC, UPS assisted, from tel.)Power lines (208VAC, from telescope)Power lines (48VDC, internal)Gbit ethernet (optical fiber)Fast comm link (optical)I/O signals (diagnostic lines)
Cooling lines (from telescope)
W@LBT: structure
FLAO system external review, Florence, 30/31 March 2009 5
W@LBT: 264 kg (total AGW: 684 kg)
W@LBT: Mechanical interface
FLAO system external review, Florence, 30/31 March 2009 6
3x2 connection screws (4 M8, 2 M10)3x2 connection screws (4 M8, 2 M10)
W@LBT: Mechanical interface
FLAO system external review, Florence, 30/31 March 2009 76 connection M10 screws
2 connection M6 screws
W@LBT: Cooling interface
FLAO system external review, Florence, 30/31 March 2009 8
LBT672: interface sectioning
FLAO system external review, Florence, 30/31 March 2009 9
1
2
4
3
Spider-arm cabinet
M2 unit in Hub
Mirror unit:303 kgHexapod: 149 kgHub: 253 kg Tot: 708 kg
LBT672: Mechanical interfaces
FLAO system external review, Florence, 30/31 March 2009 10
Electrical/Communication
FLAO system external review, Florence, 30/31 March 2009 11
Electrical/Communication/Cooling
FLAO system external review, Florence, 30/31 March 2009 12
Fiber connector (18 fibers)
Power and digital flags connector
Fluxmeter connector
Hub temperature
End of presentation
FLAO system external review, Florence, 30/31 March 2009 13