FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R....

13
FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence, 30/31 March 2009

Transcript of FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R....

Page 1: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

FLAO Interface Control Document

Presented by A. Riccardi

S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni

FLAO system external review, Florence, 30/31 March 2009

Page 2: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

ICD structure

• Described interfaces for W@LBT and LBT672:– Mechanical– Optical– Cooling– Electrical power and signals– Network– Real time communication

• SW interfaces in a different document

FLAO system external review, Florence, 30/31 March 2009 2

Page 3: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

Overview of connections

FLAO system external review, Florence, 30/31 March 2009 3

LBT672:M2 unit in Hub

LBT672:Spider-arm cabinet

W@LBT: AGW unit

Page 4: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

Overview of physical connections

FLAO system external review, Florence, 30/31 March 2009 4

Power lines (120VAC, UPS assisted, from tel.)Power lines (208VAC, from telescope)Power lines (48VDC, internal)Gbit ethernet (optical fiber)Fast comm link (optical)I/O signals (diagnostic lines)

Cooling lines (from telescope)

Page 5: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

W@LBT: structure

FLAO system external review, Florence, 30/31 March 2009 5

W@LBT: 264 kg (total AGW: 684 kg)

Page 6: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

W@LBT: Mechanical interface

FLAO system external review, Florence, 30/31 March 2009 6

3x2 connection screws (4 M8, 2 M10)3x2 connection screws (4 M8, 2 M10)

Page 7: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

W@LBT: Mechanical interface

FLAO system external review, Florence, 30/31 March 2009 76 connection M10 screws

2 connection M6 screws

Page 8: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

W@LBT: Cooling interface

FLAO system external review, Florence, 30/31 March 2009 8

Page 9: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

LBT672: interface sectioning

FLAO system external review, Florence, 30/31 March 2009 9

1

2

4

3

Spider-arm cabinet

M2 unit in Hub

Mirror unit:303 kgHexapod: 149 kgHub: 253 kg Tot: 708 kg

Page 10: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

LBT672: Mechanical interfaces

FLAO system external review, Florence, 30/31 March 2009 10

Page 11: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

Electrical/Communication

FLAO system external review, Florence, 30/31 March 2009 11

Page 12: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

Electrical/Communication/Cooling

FLAO system external review, Florence, 30/31 March 2009 12

Fiber connector (18 fibers)

Power and digital flags connector

Fluxmeter connector

Hub temperature

Page 13: FLAO Interface Control Document Presented by A. Riccardi S. Esposito, A. Tozzi, A. Riccardi, R. Biasi, D. Gallieni FLAO system external review, Florence,

End of presentation