FL400 FLUORESCENCE IMAGING FL400... · 2019. 10. 8. · FL400 fluorescence in combination with the...

4
Invisible becomes visible FL400 FLUORESCENCE IMAGING Blue light fluorescence for ARveo and M530 microscopes

Transcript of FL400 FLUORESCENCE IMAGING FL400... · 2019. 10. 8. · FL400 fluorescence in combination with the...

Page 1: FL400 FLUORESCENCE IMAGING FL400... · 2019. 10. 8. · FL400 fluorescence in combination with the active substance 5-ALA helps you distinguish both the bulk and margins of the tumor

Invisible becomes visible

FL400FLUORESCENCE IMAGING

Blue light fluorescence for ARveo and M530 microscopes

Page 2: FL400 FLUORESCENCE IMAGING FL400... · 2019. 10. 8. · FL400 fluorescence in combination with the active substance 5-ALA helps you distinguish both the bulk and margins of the tumor

FL400 fluorescence with 5-ALA allows demarcation of tumor tissue from healthy brain tissue to support precise resection.

INVISIBLE BECOMES VISIBLE

Flexible fluorescence observation The OpenArchitecture design of ARveo and M530 microscopes ensures seamless integra-tion of the FL400 module at any time. TriFluoro technology enables integration of three types of fluorescence in one microscope. Easily upgrade whenever your needs change or new technologies are introduced.

Crisp, real-time delineationThe technology of the FL400 module delivers intense, homogenous excitation light and a well-adjusted observation spectrum. This is combined with the premium light and optics of the ARveo or M530 microscope in real time for bright, high-contrast delineation of tumor margins to support confident resectioning.

When resecting a malignant glioma, maximum removal of tumor cells with minimal impact to brain tissue is key to an optimal patient outcome. FL400 fluorescence in combination with the active substance 5-ALA helps you distinguish both the bulk and margins of the tumor more easily. With more visual information you can work more confidently.

If it glows red it's tumorBefore surgery, the patient drinks a 5aminolevulinic acid (5-ALA) solution. The 5-ALA is taken up by glioma cells and converted into the fluorescent PPIX. This is not normally visible to the human eye, but when illuminated under FL400 blue light, the PPIX in the tumor glows an intense red or pink, while healthy tissue appears blue.

Page 3: FL400 FLUORESCENCE IMAGING FL400... · 2019. 10. 8. · FL400 fluorescence in combination with the active substance 5-ALA helps you distinguish both the bulk and margins of the tumor

Easy handling for interruption-free surgeryChanging observation modes is easy. Switching from white light mode to blue light fluorescence mode and back requires just a click of a button on the handgrip or footswitch. View directly in the eyepieces and continue working without interruption.

In blue light mode, glioma tissue that has accumulated 5-ALA glows bright red or pink, while tissue that hasn't appears blue aiding resection.

FL400 blue light modeWhite light mode

Recording and display made simpleShare the view with your team in the OR via HD or 3D monitor and record in HD or 3D for later presentation and teaching. Start record-ing with the touch of a button. Mode Control technology automatically activates the cor-rect video display and recording settings that have been optimized for fluorescence and white light modes.

Page 4: FL400 FLUORESCENCE IMAGING FL400... · 2019. 10. 8. · FL400 fluorescence in combination with the active substance 5-ALA helps you distinguish both the bulk and margins of the tumor

Leica Microsystems (Schweiz) AG · Max Schmidheiny Strasse 201 · CH-9435 HeerbruggT +41 71 726 3333 · F +41 71 726 3399

www.leica-microsystems.com

Leica Microsystems (Schweiz) AG · Max Schmidheiny Strasse 201 · CH-9435 HeerbruggT +41 71 726 3333 · F +41 71 726 3399

www.leica-microsystems.com

Leica Microsystems (Schweiz) AG · Max Schmidheiny Strasse 201 · CH-9435 HeerbruggT +41 71 726 3333 · F +41 71 726 3399

www.leica-microsystems.com

TECHNICAL DATA: FL400 FILTER SET CHARACTERISTICS

Fluorescence excitation Peak of ~380 – ~430 nm +/- 5% (blue)

Fluorescence signal ≥ 444 nm

MICROSCOPE COMPATIBILITY

New and existing ARveo, M530 OH6, M530 OHX*

*Not all configurations are available in all regions. Contact your local Leica representative for availability information.

CONNECT WITH US!

Leica Microsystems (Schweiz) AGMax Schmidheiny-Strasse 2019435 Heerbrugg, Switzerland

Not all products or services are approved or offered in every market and approved labeling and instructions may vary between countries. Please contact your local Leica representative for details.

FL400

MC-

0000

393

· 08

.10.

2019

· EN

· Co

pyrig

ht ©

201

9 Le

ica

Mic

rosy

stem

s (S

chw

eiz)

AG. A

ll rig

hts

rese

rved

. Sub

ject

to m

odifi

catio

ns. O

ther

trad

emar

ks s

how

n he

rein

are

the

prop

erty

of t

heir

resp

ectiv

e ow

ners

. LEI

CA a

nd th

e Le

ica

Logo

are

regi

ster

ed tr

adem

arks

of L

eica

Mic

rosy

stem

s IR

Gm

bH. F

L400

is a

regi

ster

ed tr

adem

ark

of L

eica

Mic

rosy

stem

s Gm

bH.