FIXED DISPLACEMENT VANE PUMPS HS - HQ - VH...

39
Pumps, cartridges and spare parts are interchangeable to Vickers design hydraut.com Single Vane Pumps Double Vane pumps Thru-Drive Vane pumps FIXED DISPLACEMENT VANE PUMPS HS - HQ - VH SERIES

Transcript of FIXED DISPLACEMENT VANE PUMPS HS - HQ - VH...

Based on using petroleum oil at 49°C (120°F), viscosity 32 cSt at 38°C (150 SUS at 100°F), and 0 psi inlet pressure.

Parts and mounting are interchangeable with Vickers

JC T6C SERIES HIGH PERFORMANCESINGLE VANE PUMPS

hydraut.comPumps, cartridges and spare parts are interchangeable to Vickers design

hydraut.com

Single Vane PumpsDouble Vane pumps

Thru-Drive Vane pumps

FIXED DISPLACEMENT VANE PUMPSHS - HQ - VH SERIES

SINGLE VANE PUMP

PUMP DRIVEDirect coaxial drive is recommended via flexible coupling. For indirect drives imposing a radial load on the shaft, consult HYDRAUT or your nearest distributor for advice.

ROTATIONThe direction of rotation can be reversed by turning the ring, rotor and vanes through 180 degrees.Direction of rotation is viewed from the shaft end.

STARTINGHYDRAUT vane pumps are self priming, however, if possible, fill the pump with oil before starting or bleed the outlet port while the pump is running to remove any trapped air.

FILTRATIONFor satisfactory service life, full flow filtration to provide fluid cleanliness conforming to ISO code 18/15 or better is recommended.

HYDRAULIC FLUIDSUse antiwear industrial hydraulic oils with a viscosity of 25-49 cST. Automotive crankcase oils SAE10-SAE20 may also be used depending on the operating temperature. The optimum operating temperature is 50 °C with a maximum of 70 °C. At higher temperatures service life is decreased with degradation of the wearing parts and seals.

For fire resistance fluids, the “F3” version with special seals must be used at reduced pressures and speeds as indicated below.

MAXIMUM SPEED RANGESWith antiwear fluids: 1800 to 2500 rpm (depending on model type. See performance chart).

With synthetic fluids, water glycols and water in oil emulsions, the maximum recommended speed is 1200 rpm.

Speeds shown are given as a guide only based on the correct fluid and correct suction characteristics as recommended by our Technical Services department.

Long or restricted suction lines can cause cavitation, therefore the maximum running speed must be reduced. Avoid using 90 degree elbows in suction lines, use swept bends where possible. Too viscous a fluid will also cause cavitation.

When using lower displacement pumps within a given pump frame size, speeds slightly higher than those shown in the charts are acceptable.

For antiwear hydraulic fluids and water glycols, the inlet pressure must not exceed 0.2 bar vacuum, for synthetic fluids and water in oil emulsions, the inlet pressure must not exceed 0.1 bar vacuum.

MINIMUM SPEED: 600 rpm

MAXIMUM CONSTANT PRESSUREAnti-wear Hydraulic Oil: from 175 to 210 BarSynthetic Oil: from 175 to 210 BarWater-Glycol emulsions: 160 BarWater-in-oil emulsions: 070 BarThis data is for H*20, H*25, H* 35, H* 45, double and triple pumps. For other pumps see chart.

The intermittent pressures shown in the table can be maintained for 10% of the time, with a maximum duration of 6 seconds/minute.

hydraut.comhydraut.com

1

2

SINGLE VANE PUMP

hydraut.comhydraut.com

SINGLE VANE PUMP

VH20(F) - 1P11S - 1C (8) - (H) - (L)

Model Shaft

VH10, VH20 1 - Straight keyed

3 - Threaded with woodruff key

Cover 6 - Woodruff key stub (VH20 only)

Omit - Standard Cover 11 - SplinedF - Flow Control Cover 12 - Splined (VH10 only)

P - Priority Valve Cover 15 - Splined (VH20 only)

38 - Splined (VH20 only)

Mounting 123 - Threaded with woodruff key

1 - 2 - Bolt Flange Outlet Port Position

(Viewed from cover end)

Inlet Port Connection A - Opposite inlet

S - 1.3125"-12 Str.thd. (VH10) B - 90 CCW from inlet

- 1.625"-12 Str.thd. (VH20) C - Inline with inlet

P - 1.00" NPT (VH10) D - 90°

°

CW from inlet

- 1.25" NPT (VH20) Flow rate Setting for Flow control and

B - 1.00" BSP (VH10) Priority Valve Cover L/min (USgpm)

- 1.25" BSP (VH20) 2 - 7.6 (2) 6 - 22.7 (6)

3 - 11.4 (3) 7 - 26.5 (7)

Delivery (USgpm at 1200 rpm) 4 - 15.2 (4) 8 - 30.3 (8)

VH10-1, 2, 3, 4, 5, 6, 7 5 - 19.0 (5)

VH20-5, 6, 7, 8, 9, 10, 11, 12, 13 Pressurer Setting for Flow control and

Priority Valve Cover bar (psi)

A - 17 (250) F - 103 (1500)

Outlet Port Connection B - 34 (500) G - 121 (1750)

VH10 and VH20 C - 52 (750) H - 138 (2000)

S - 0.750"-16 Str.thd. (VH10) D - 69 (1000) J - 155 (2200)

- 1.0625"-12 Str.thd. (VH20) E - 86 (1250) K - 172 (2500)

P - 0.500" NPT (VH10) Shaft Rotation

- 0.750" NPT (VH20) (Viewed from shaft end)

B - 0.500" BSP (VH10) Omit - Turn right

- 0.750" BSP (VH20) L - Turn left

VH10F, VH10P, VH20F and VH20P

S - 0.750"-16 Str.thd. for outlet and 1.0625"-12 Str. thd. For tank port (VH20F)

P - 0.750"-16 Str.thd. for outlet and 0.500" NPT for tank port (VH10F and VH20F)

T - 0.750"-16 Str.thd. for outlet and tank port (VH10F)

- 0.750"-16 Str.thd. for primary outlet and tank port 0.875"-14 Str.thd.for secondary outlet (VH20P)

K - 0.5625"-18 Str.thd. for primary outlet and tank port and 0.750"-16 Str.thd.for secondary outlet (VH10P)T - 0.750"-16 Str.thd. for outlet and 0.750"-16 Str.thd. for tank port (VH20F)

1 2

1

2

3

4

5

6

7

8

9

3 4 5 6 7 8 9 10 11

10

11

3

hydraut.com

CODESINGLE VANE PUMP

4

hydraut.com

SINGLE VANE PUMP

VICKERS DESIGN VANE PUMPSCHARACTERISTICS

hydraut.com

TYPEFLOW SPEED (rpm)

PRESSURE(bar) Nominal

power(3)

CONNECTIONWHEIGHT

(Kgs.)US Gal.at1200 rpm

Min Max. Contin. Intermit. Inlet Outlet

VH10

1

600

4800

155

140

177

0,7

(4) (4) 4,5

2 4500 1,43 4000 2,14 3400 2,75 3200 3,26 3000 3,77 2800 4,2

VH20

6

600

3400

155

140

177

3,9

(4) 7,3

7 3000 4,48 2800 5,19 2800 5,611 2500 6,512 2400 7,513 2400 8,1

HS20 HQ20

2

600 1800

175

210

210

1,9

Ø1½” 3/4” 12

5 48 6,611 7,312 7,414 7,6

HS25HQ25

10

60025001800(HS)

175 210

9,3

Ø1½” Ø1” 15

12 10,414 11,615 12,417 13,819 14,621 16,8

HS35HQ35

21

600

254001800(HS)

1500

175

125

210

150

16,8

Ø2" Ø1¼" 23

25 20,330 24,335 27,438 29,342 31,345 33,3

HS45HQ45

42

60022001800(HS)

155 175

32,3

Ø3" Ø1½" 35,5

45 35,150 37,960 46,167 51,275 57,4

5

hydraut.com

SINGLE VANE PUMP

VH10

hydraut.com

6

hydraut.com

SINGLE VANE PUMP

VH10

hydraut.com

FLOW AND INPUT POWER DIAGRAMS

7

hydraut.com

SINGLE VANE PUMP

VH20

hydraut.com

8

hydraut.com

SINGLE VANE PUMP

VH20

hydraut.com

FLOW AND INPUT POWER DIAGRAMS

9

hydraut.com

SINGLE VANE PUMPS

HS-20 / HQ-20

hydraut.com

10

hydraut.com

SINGLE VANE PUMPS

HS-20 / HQ-20FLOW AND INPUT POWER DIAGRAMSFLOW AND INPUT POWER DIAGRAMS

hydraut.com

11

hydraut.com

SINGLE VANE PUMPS

HS-25 / HQ-25

hydraut.com

12

hydraut.com

FLOW AND INPUT POWER DIAGRAMS

SINGLE VANE PUMPS

HS-25 / HQ-25

hydraut.com

13

hydraut.com

SINGLE VANE PUMPS

HS-35 / HQ-35

hydraut.com

14

hydraut.com

SINGLE VANE PUMPS

HS-35 / HQ-35FLOW AND INPUT POWER DIAGRAMS

hydraut.com

15

hydraut.com

SINGLE VANE PUMPS

HS-45 / HQ-45

hydraut.com

16

hydraut.com

SINGLE VANE PUMPS

HS-45 / HQ-45

hydraut.com

FLOW AND INPUT POWER DIAGRAMS

17

hydraut.com

THRU DRIVE SINGLE VANE PUMPS

hydraut.com

18

hydraut.com

THRU DRIVE SINGLE VANE PUMPSCODE

hydraut.com

19

hydraut.com

THRU DRIVE SINGLE VANE PUMPSCHARACTERISTICS

hydraut.com

20

hydraut.com

DIMENSIONS IN MILLIMETRES 1” = 25.4 MILLIMETRES

REAR FLANGE MOUNTINGS OFTHE HS25T THRU DRIVE PUMPS

hydraut.com

21

hydraut.com

THRU DRIVE PUMPS

HS25TDIMENSIONS IN MILLIMETRES 1” = 25.4 MILLIMETRES

Nº 1 Shaft Nº11 Shaft Nº 86 Shaft

Enquire about other types of shaft

���������������

DIMENSIONS IN MILLIMETRES

DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres

hydraut.com

22

hydraut.com

THRU DRIVE PUMPS

HS35TDIMENSIONS IN MILLIMETRES 1” = 25.4 MILLIMETRES

Enquire about other types of shaft

H*35TA 20H*35TB 30H*35TC 38

AModel

Nº 1 Shaft Nº11 Shaft Nº 86 Shaft

����������������

DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres

hydraut.com

Nº 1 Shaft Nº11 Shaft Nº 86 Shaft

Enquire about other types of shaft

���������������

DIMENSIONS IN MILLIMETRES

DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres

23

hydraut.com

hydraut.com

THRU DRIVE PUMPS

HS45TDIMENSIONS IN MILLIMETRES 1” = 25.4 MILLIMETRES

Nº 1 Shaft Nº11 Shaft Nº 86 Shaft

Enquire about other types of shaft

���������������

DIMENSIONS IN MILLIMETRES

DIMENSIONS IN MILLIMETRES 1" = 25.4 millimetres

24

hydraut.com

DOUBLE VANE PUMP

Model Shaft

VH2010, VH2020 1 - Straight keyed

Cover 11 - Splined

Omit - Standard Cover Shaft End Outlet Port PositionF - Flow Control Cover (Viewed from cover end)

P - Priority Valve Cover A - Opposite inlet

Mounting B - 90° CCW from inlet

1 - 2-Bolt Flang C - Inline with inlet

Inlet Port Connection D - 90° CW from inlet

F - 4-bolt Flange Dia 1.5" (VH2010) Cover End Outlet Port Connection

- 4-bolt Flange Dia 2.0" (VH2020) (Viewed from cover end)

Shaft End Pump Delivery (Usgpm at 1200 rpm) VH2010,VH2010F,VH2010P VH2020,VH2020F,VH2020P

5, 6, 7, 8, 9, 10, 11, 12, 13 A - 135° CCW from inlet A - Opposite inlet

Shaft End Outlet Port Connection B - 45° CCW from inlet B - 90° CCW from inlet

S - 1.0625"-12 Str.thd. C - 45° CW from inlet C - Inline with inlet

P - 0.750" NPT D - 135° CW from inlet D - 90° CW from inlet

B - 0.750" BSP Flow rate Setting for Flow control and Cover End Pump Delivery (Usgpm at 1200 rpm) Priority Valve Cover L/min (Usgpm)

VH2010 - 1, 2, 3, 4, 5, 6, 7 2 - 7.6 (2) 6 - 22.7 (6)

VH2020 - 5, 6, 7, 8, 9, 10, 11, 12, 13 3 - 11.4 (3) 7 - 26.5 (7)

4 - 15.2 (4) 8 - 30.3 (8)

5 - 19.0 (5)

Pressurer Setting for Flow control and

Priority Valve Cover bar (psi)

A - 17 (250) F - 103 (1500)

Cover End Outlet Port Connection

B - 34 (500) G - 121 (1750)

VH2010 and VH2020

C - 52 (750) H - 138 (2000)

S - 0.750"-16 Str.thd. (VH2010)

D - 69 (1000) J - 155 (2200)

- 1.0625"-12 Str.thd. (VH2020)

E - 86 (1250) K - 172 (2500)

P - 0.500" NPT (VH2010)

Shaft Rotation

B - 0.500" BSP (VH2010)

(Viewed from shaft end)

- 0.750" BSP (VH2020)

Omit - Turn right

VH10F, VH10P, VH20F and VH20P

L - Turn left

S - 0.750"-16 Str.thd. for outlet and 1.0625"-12 Str. thd. For tank port (VH2020F)

P - 0.750"-16 Str.thd. for outlet and 0.500" NPT for tank port (VH2010F and VH2020F)

T - 0.750"-16 Str.thd. for outlet and tank port (VH2010F and VH2020F)

- 0.750"-16 Str.thd. for main outlet and tank port 0.875"-14 Str.thd.for secondary outlet (VH2020P)

K - 0.5625"-18 Str.thd. for main outlet and tank port and 0.750"-16 Str.thd.for secondary outlet (VH2010P)rT - 0.750"-16 Str.thd. for outlet and 0.750"-16 Str.thd. for tank port (VH2020F)

1

2

3

4

5

6

7

10

12

13

14

9

8

11

VH2010 (F) - 1 F13S7S 1CC- -- (8) (H) (L)

25

hydraut.com

DOUBLE VANE PUMPCODE

hydraut.com

26

hydraut.com

DOUBLE VANE PUMPSCHARACTERISTICS

DOUBLE VANE PUMPS CHARACTERISTICS

hydraut.com

TYPE

SHAFT END COVER END

WHEIGHT (Kgs.)

FLOWMax.rpm

PRESSURE(bar) Nominal

power(3)

FLOWMax.rpm

PRESSURE(bar) Nominal

power(3)US Gal.at

1200 rpmContin. Intermit.

US Gal.at1200 rpm

Contin. Intermit.

HS2520HQ2520

10

25001800(HS)

175 210

9,3 2

2500 175 210

1,9

21

12 10,4 5 4

14 11,6 8 6,6

15 12,4 11 7,3

17 13,8 12 7,4

19 15,2 14 7,6

21 16,8

HS3520HQ3520

21

24001800(HS)

1500

175

125

210

150

16,8 2

2500 175 210

1,9

31

25 20,3 5 4

30 24,3 8 6,6

35 27,4 11 7,3

38 29,3 12 7,4

42 31,3 14 7,6

45 33,3

HS3525HQ3525

2124001800(HS)

1500

175

125

210

150

16,8 10

25001800(HS)

175 210

9,3

33

25 20,3 12 10,4

30 24,3 14 11,6

35 27,4 15 12,4

38 29,3 17 13,8

42 31,3 19 15,2

HS4520HQ4520

45

22001800(HS)

155 175

33,3 21

2500 175 210

16,8

46

42 32,3 2 1,9

45 35,1 5 4

50 37,9 8 6,6

60 46,1 11 7,3

67 51,2 12 7,4

75 57,4 14 7,6

HS4525HQ4525

42

22001800(HS)

155 175

32,3 10

25001800(HS)

175 210

9,3

45

45 35,1 12 10,4

50 37,9 14 11,6

60 46,1 15 12,4

67 51,2 17 13,8

75 57,4 19 15,2

21 16,8

HS4535HQ4535

42

45

50

60

67

75

22001800(HS)

155 175

32,3

35,1

37,9

46,1

51,2

57,4

21

25

30

35

38

42

45

24001800(HS)

1500

175

125

210

150

16,8

20,3

24,3

27,4

29,3

31,3

33,3

55

27

hydraut.com

HS-2520, HQ-2520

DOUBLE VANE PUMPS

hydraut.com

28

hydraut.com

HS-3520, HQ-3520

DOUBLE VANE PUMPS

hydraut.com

29

hydraut.com

HS-3525, HQ-3525

DOUBLE VANE PUMPS

hydraut.com

30

hydraut.com

HS-4520, HQ-4520

DOUBLE VANE PUMPS

hydraut.com

31

hydraut.com

HS-4525, HQ-4525

DOUBLE VANE PUMPS

hydraut.com

32

hydraut.com

HS-4535, HQ-4535

DOUBLE VANE PUMPS

hydraut.com

33

hydraut.com

DIMENSIONS AND FLOW

IDENTIFICATION

hydraut.com

34

hydraut.com

PUMP ROTATION

hydraut.com

35

hydraut.com

IDENTIFICATION

PUMP ROTATION

hydraut.com

36

hydraut.com

RANGE OF PRODUCTS

hydraut.com

Single • Double • Thru-Drive vane PumPS

HYDRAULIC CYLINDERS

variable DiSPlacemenT PumP h(S)P-10v

DIRECTIONAL CONTROL VALVE

hydraut.com