First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting...
description
Transcript of First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting...
![Page 1: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/1.jpg)
First results of fast IR camera diagnosticFirst results of fast IR camera diagnostic
J-W. Ahn and R. Maingi
ORNLNSTX Monday Physics Meeting
LSB-318, PPPLJune 22, 2009
NSTXNSTX Supported by
College W&MColorado Sch MinesColumbia UCompXGeneral AtomicsINELJohns Hopkins ULANLLLNLLodestarMITNova PhotonicsNew York UOld Dominion UORNLPPPLPSIPrinceton UPurdue USNLThink Tank, Inc.UC DavisUC IrvineUCLAUCSDU ColoradoU IllinoisU MarylandU RochesterU WashingtonU Wisconsin
Culham Sci CtrU St. Andrews
York UChubu UFukui U
Hiroshima UHyogo UKyoto U
Kyushu UKyushu Tokai U
NIFSNiigata UU Tokyo
JAEAHebrew UIoffe Inst
RRC Kurchatov InstTRINITI
KBSIKAIST
POSTECHASIPP
ENEA, FrascatiCEA, Cadarache
IPP, JülichIPP, Garching
ASCR, Czech RepU Quebec
![Page 2: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/2.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 2June 22, 2009
Summary
• The new fast IR camera is working reliably to measure divertor heat flux with temporal resolution of 1.6 - 6.3kHz and spatial resolution of 6.4mm
• Temporal resolution is fast enough to resolve transient
events
• Time averaged temperature and heat flux profiles agree well with slow IR data
• Data analysis for various plasma conditions in progress
![Page 3: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/3.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 3June 22, 2009
IR images of lower divertor for an ELMy H-mode
View from the top, 128x128 pixels, 1.6kHz
Radial cut for data analysis
![Page 4: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/4.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 4June 22, 2009
Measured surface temperature
Temperature profiles from measured surface emissivity
1.6kHz
![Page 5: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/5.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 5June 22, 2009
Calculated heat flux
Heat flux profiles from surface temperature by solving heat conduction equation
1.6kHz
![Page 6: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/6.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 6June 22, 2009
ELM resolved surface temperature
1.6kHz
Short ELM rise time gives only one frame for a rising ELM even at 1.6kHz
![Page 7: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/7.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 7June 22, 2009
ELM resolved heat flux
1.6kHz
ELMs push strike point out by 2-3cm
![Page 8: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/8.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 8June 22, 2009
Comparison with slow IR measurement
30Hz 1.6kHz
Temp. profiles from slow IR Time averaged temperature profiles from fast IR
![Page 9: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/9.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 9June 22, 2009
Comparison with slow IR measurement
30Hz 1.6kHz
Heat flux profiles from slow IR Time averaged heat flux profiles from fast IR
![Page 10: First results of fast IR camera diagnostic J-W. Ahn and R. Maingi ORNL NSTX Monday Physics Meeting LSB-318, PPPL June 22, 2009 NSTX Supported by College.](https://reader030.fdocuments.in/reader030/viewer/2022020213/5a4d1b5d7f8b9ab0599abd87/html5/thumbnails/10.jpg)
NSTXNSTX NSTX Monday Physics Meeting – First results of fast IR camera (Ahn) 10June 22, 2009
We appreciate excellent technical supports from PPPL staff members!!!