FIRST FLOOR PLAN - NT Consulting Engineers

6
- - - A3 2 FIRST FLOOR PLAN SHANE RICHARDSON LOT 2881 (75) HILLIER Rd., HOWARD SPRINGS LEGEND Note: Mobile: 0427 411 633 Email: [email protected] Engineers Consulting Northern Territory, Australia P.O. Box 900 COOLALINGA 0839 ABN 73 102 631 186 N.T. Consulting Engineers S4 4 S5 3 S5 1 S4 2 wc r lt wm s 1st FLOOR WINDOW & DOOR SCHEDULE U394625-S2 FIRST FLOOR PLAN 10170 18210 5790 600 1200 80 1015 1800 1095 380 4000 15000 2400 2400 2920 80 2000 80 7640 80 2000 4000 1800 1800 2469 600 870 3000 1670 1800 915 80 4000 995 1800 995 2000 sh 2 4m 1 0 SCALE: 1:125 BUILDER TO PROVIDE FLASHING/TRIMS & ENSURE WATERPROOFING IN ACCORDANCE WITH THE BCA FITTINGS & FIXTURES wc toilet sh shower b bath s sink r wardrobe wm washing machine hb hand basin db double hand basin lt laundry tub p pantry f fridge fw floor waste www.ntconsultingengineers.com.au 500 500 500 15 3450 1100 320 PROPOSED SHED & HOME BASED CONTRACTING

Transcript of FIRST FLOOR PLAN - NT Consulting Engineers

- - - A32

FIRST FLOOR PLAN

SHANE RICHARDSONLOT 2881 (75) HILLIER Rd., HOWARD SPRINGS

LEGEND

Note:

Mobile: 0427 411 633 Email: [email protected]

Engineers

Consulting

Northern Territory, Australia

P.O. Box 900

COOLALINGA 0839

ABN 73 102 631 186

N.T. Consulting Engineers

S4

4 S5

3S5

1

S42

wc

r

ltwm

s

1st FLOOR WINDOW & DOOR SCHEDULE

U394625-S2

FIRST FLOOR PLAN

10170 18210 5790

6001200

80

101518001095

380

4000

15

00

02

40

02

40

0

29

20

80

20

00

80

76

40

80

20

00

40

00

18

00

18

00

24

69

60

0

87

03

00

01

67

01

80

09

15

80

40

00

995 1800 995 2000

sh

2 4m10

SCALE: 1:125

BUILDER TO PROVIDE FLASHING/TRIMS &

ENSURE WATERPROOFING IN ACCORDANCE

WITH THE BCA

FITTINGS & FIXTURES

wc toilet

sh shower

b bath

s sink

r wardrobe

wm washing machine

hb hand basin

db double hand basin

lt laundry tub

p pantry

f fridge

fw floor waste

www.ntconsultingengineers.com.au

50

05

00

500

15

34

50

1100

32

0

PROPOSED SHED & HOME BASED CONTRACTING

- - - A3

SHANE RICHARDSONLOT 2881 (75) HILLIER Rd., HOWARD SPRINGS

U394625-S4Mobile: 0427 411 633 Email: [email protected]

Engineers

Consulting

Northern Territory, Australia

P.O. Box 900

COOLALINGA 0839

ABN 73 102 631 186

N.T. Consulting Engineers

4

ELEVATIONS 1 & 2www.ntconsultingengineers.com.au

15

ELEVATION 1

±0.00 GFL

+3350 FFL

+5680 Eave

+8250 Ridge

-250 NGL

+2100 Lintel

+5510 Lintel

ELEVATION 2

±0.00 GFL

+3350 FFL

+5680 Eave

+8250 Ridge

-250 NGL

+2100 Lintel

+5510 Lintel

PROPOSED SHED & HOME BASED CONTRACTING

- - - A3

SHANE RICHARDSONLOT 2881 (75) HILLIER Rd., HOWARD SPRINGS

U394625-S5Mobile: 0427 411 633 Email: [email protected]

Engineers

Consulting

Northern Territory, Australia

P.O. Box 900

COOLALINGA 0839

ABN 73 102 631 186

N.T. Consulting Engineers

5

ELEVATIONS 3 & 4www.ntconsultingengineers.com.au

15

NGL

ELEVATION 4

15°15°

2°2°

-150 Verandah

±0.00 GFL

-250 NGL

+2100 Lintel

+3350 FFL

+5820 Top of Beam

+5450 Lintel

+8250 Ridge

NGL

15°15°

ELEVATION 3

±0.00 GFL

+3350 FFL

+5580 Eave

+4000 RD Head

+8250 Ridge

-250 NGL

PROVIDE STAINLESS STEEL WIRE

BALCONY BALUSTRADE IN

ACCORDANCE WITH THE BCA

10

00

PROPOSED SHED & HOME BASED CONTRACTING

- - - A3

SHANE RICHARDSONLOT 2881 (75) HILLIER Rd., HOWARD SPRINGS

U394625-S9Mobile: 0427 411 633 Email: [email protected]

Engineers

Consulting

Northern Territory, Australia

P.O. Box 900

COOLALINGA 0839

ABN 73 102 631 186

N.T. Consulting Engineers

9

SECTION A

F1

20 BASEPLATE

4 - 20Ø 8.8/S x 750 TAGS:

50 SQ x 10 PL DIST

WASHER @ ENDS

Note:

INTERNAL FOOTING OMITTED

FOR CLARITY

NGL

F6

F6

0.2 WPM. 50 SAND

BED ON 150 LAYERS

MAX OF SELECT

FILL COMPACTED

TO 95% MMDD

SL8TM3:

60 BOT COVER

F1

0.42 BMT VERTICAL

SPANDEK WALL CLADDING

VALLEY FASTENED AS PER

DTC M/307/1

0.42 BMT SPANDEK ROOF CLADDING

CREST FIX w/ CYCLONE WASHERS

AS PER DTC M/311/1. UNDERLAP

BALCONY SHEETING 150, TURN

UP PAN ENDS

C20024 GIRTS @ 1200 CRS MAX

8 PL CL: 2-M12 4.6/S BOLTS. PROVIDE

1 ROW OF BRIDGING @ MIDSPAN

50 thk 80 MPa

non shrink grout

SECTION

SCALE: 1:75

TYPICAL

A

S6/S7/S8

PORTAL SHED

R

1

C1

S1

FULL PENETRATION

BUTT WELD @ FLANGES

6CFW ELSEWHERE

12 GUSSET PL

FPBW @ ENDS

6CFW TO WEB

(EA SIDE)

FLY BRACING

AS SCHEDULED

FLY BRACING

AS SCHEDULED

C1

F1

PROVIDE CAGE:

4 N12 VERT w/ N12

LIGS @ 400 CRS

100

F6

www.ntconsultingengineers.com.au

Note:

PROVIDE C10015 RAKING GIRT

M12 BOLT TO PURLINS @ EA

CROSSING

C1C1

R

1

R

1

M2M2

F2

PROVIDE CAGE:

4 N12 VERT w/ N12

LIGS @ 400 CRS

10 BASEPLATE

2-20Ø 8.8/S x 600 TAGS

F2

6 PL CL. PROVIDE 50 VERTICALLY

SLOTTED HOLE & M20 4.6/S BOLT

(SNUG TIGHT & NIP) POSITION BOLT AT

TOP OF VERTICAL SLOT AS SHOWN

R

2R

2

12 GUSSET PL

6CFW TO WEB

& FLANGES

(EA SIDE)

S1

M2

M2

6 B/P. FIX TO SLAB

w/ 2 No. M12 HILTI

HIT RE 500 C/A

60 EMBED

C20019 FRAMING

GPB @ JUNCTIONS

2-M12 BOLTS EA WAY

girt

10 BASEPLATE

2-16Ø 8.8/S x 150 TAGS:

FIX TO SLAB w/ HILTI

HIT RE 500 C/A: 150 EMBED

FULL PENETRATION

BUTT WELD @ FLANGES

6CFW ELSEWHERE

15

LAPPED Z20024 PURLINS (900 LAP) @ 1270 CRS MAX

8 PL CL: 6-M12 8.8/S PURLIN BOLTS

PROVIDE BRIDGING @ MIDSPAN

PROPOSED SHED & HOME BASED CONTRACTING

FLY BRACING

AS SCHEDULED

FLY BRACING

AS SCHEDULED

FLY BRACING

AS SCHEDULED

Note:

C20019 GABLE END GIRTS

@ 1200 CRS MAX. 8 PL CL: 2-M12 4.6/S

1 ROW OF BRIDGING @ MIDSPAN

NORTHERN TERRITORY OF AUSTRALIA BUILDING ACT

SECTION 40 – CERTIFICATE OF COMPLIANCE – STRUCTURAL DESIGN

Revised 31/7/14 No changes to the declaration are permitted Page 1 of 2

.91*6963*63*.0006

All sections must be completed – mark N/A to any question that does not apply

PROPERTY / PROJECT DETAILS

Owner (if known):

Lot/Portion Number: 2881 Address: 75 Hillier Rd

Location: Howard Springs Town / Hundred : Bagot

Description of works : Proposed Shed & Home Based Contracting

DOCUMENTS ATTACHED

Drawing Nos: NTCE Dwg No.’s U394625-S1:U394625-S15

Other:

DESIGN BASIS (please list relevant Standards used in the design) AS1170, AS4100, AS3600, AS3700, AS4600, AS AS2870, AS1554, AS1312, AS3850

Class of Building (BCA): 1a & 10a Type of Construction (BCA volume 1 §C1.1): (eg. Type A fire-resisting construction) n/a

Building Importance Level (BCA Table B1.2a): II Annual Probability of Exceedance for Wind (BCA Table 1.2b): 1 in 500

Region: C Regional ultimate wind speed VR(m/s): 69 Terrain Category: 2.5 Reference height (m): 7.5

Mz,cat : 0.90 Ms : 1.0 Mt : 1.0 Vdesθ Design Wind Speed at reference height (m/s): 62

Internal Pressure Coefficients (Cp,i): To AS 1170.2 Section 5.3 & Table 5.1

External Pressure Coefficients (Cp,e) Walls To AS 1170.2 Section 5.4 & Appendix C

Roof To AS 1170.2 Section 5.4 & Appendix C

Net Pressure Coefficients: (Cp,n) Roof / Walls To AS 1170.2 Appendix D

Imposed Loads, kPa Floor / Roof To AS 1170.1

Earthquake Design Category, EDC (Table 2.1 of AS 1170.4): n/a Annual Probability of Exceedance for Earthquake Actions (BCA Table 1.2b): 1 in n/a Importance Level (BCA): n/a Hazard Factor, Z (Section 3): n/a Class of Sub-Soil (Section 4): n/a

Safe Foundation Bearing Capacity, kPa: 150 Site classification (AS2870): S to be confirmed on site

COMMENTS / EXCLUSIONS (Exclusions to this Certificate must be clearly identified).

The following items are excluded and shall be certified separately:

• Glazed Doors & Windows inc glazing, framing & fixing & Proprietary Roller Doors

Comments:

• These Dwg’s are to be read in conjunction with Glenn Everett Workshop Dwgs & any anomalies or discrepancies referred to The certifying structural engineer before proceeding with the work

CERTIFICATION BY STRUCTURAL ENGINEER

Company Name if certification issued on behalf of a corporation Company NT Registration Number

I certify that reasonable care has been taken to ensure that the structural engineering aspects of the works as described above have been designed in accordance with the requirements of the Building Code of Australia and the Northern Territory Building Regulations.

Name (see *below) Michael Cooper

Nominee/Individual NT Registration Number 21133ES

Signature

Date 3 October, 2017

* Name and registration number of nominee signing on behalf of the company or if no company, name of individual issuing certification.

Page 2 of 2

SCHEDULE OF STRUCTURAL INSPECTIONS REQUIRED

Inspection of construction is required at the stages indicated below.

[ X ] 1. Completion of site preparation/site filling/excavations for footings prior to placement of any reinforcement or

concrete.

[ ] 2. Completion of preparations for placing of concrete strip footings including placement of reinforcement.

[ X ] 3. Completion of preparations for placing concrete slabs including compaction of fill and sand blinding, placement

of formwork, reinforcement, starter bars and cast in items.

[ X ] 4. Completion of preparations for placing of concrete pier footings including reinforcement (if any).

[ X ] 5. Starter bars and cast in items after placing of concrete and prior to any covering up work.

[ ] 6 Reinforcement to walls completed prior to core filling (inspection holes and cleanout cores to be completed).

[ X ] 7. Structural steelwork and cold formed steelwork completed and prior to any covering up work. Floor framing

system completed before floors are laid or underside is lined.

[ ] 8. Suspended concrete floor slabs with formwork, reinforcement and cast in items completed, prior to placing of

concrete.

[ X ] 9. Wall framing or blockwork wall core filling completed (with windows fixed in place) and roof framing with

connections completed and prior to sheeting or lining.

Note: [ ] Prior lodgement of truss manufacturer’s drawings, details and certification required.

[ X ] Prior lodgement of windows manufacturer’s drawings including fixings and certification required.

[ X ] 10. Structural wall linings completed and prior to any covering up work.

[ X ] 11. Final inspection upon completion of all structural work including fixings of external roof and wall claddings,

flashings, barges & vents.

[ X ] 12. Other Inspections as required by the building permit

Important Information:

1) The above inspections are required to be carried out by either the certifying engineer or the building certifier

who issued the Building Permit for the work. (If no inspections are indicated refer to the certifying engineer for

advice).

2) Where works are prescribed building works under the NT Building Act, the building certifier must be provided

with a copy of the inspection record and no further works must be carried out by the builder until the building

certifier issues a release to proceed with further works.

3) Additional non structural inspections may be required during the course of construction before the issue of an

Occupancy Permit (refer to building certifier for requirements).

4) Failure to obtain inspections may prevent the issue of an Occupancy Permit upon completion of the building

works.