Dennis C. Erickson ~ Senior Mentor for Teams 1510 and 2898
1
![Page 2: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/2.jpg)
The Real-‐Time screen on the Driver Station is called the “Dashboard”
It can be modified to include
additional functions and displays
2
![Page 3: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/3.jpg)
• Use to interface local sensors and the joystick to the communications link to the robot process
• Also has capability to handle digital and analog commands
• Also provides for a real-‐time display that can contain status, sensor and video information from the robot
3
![Page 4: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/4.jpg)
A view of the Driver Station first introduced in 2010
4
Instead of using the I/O board it is suggested that the buttons on the joysticks be used as commands to the robot
![Page 5: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/5.jpg)
Allows for the wireless communications between the driver and the robot Also used as a control system from the competition director computers (watchdog, start, Autonomous, TeleOp, etc)
5
![Page 6: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/6.jpg)
• Windows XP • 1.6 GHz Atom processor, 1 GB RAM • 16 GB solid state hard drive • 8.9” screen, 1024x600 resolution • No VGA port
6
![Page 7: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/7.jpg)
• Runs with an executable built with LabVIEW • Does what the Kwikbyte DS did in pre-‐2010 years
7
![Page 8: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/8.jpg)
Diagnostics Tab:
8
Operation Tab:
![Page 9: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/9.jpg)
IO Tab:
9
Setup Tab: Auto IP address setup, Run a simulated match, will remap joysticks
Can simulate analog and digital I/O, shows states of I/O hardware
![Page 10: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/10.jpg)
• Connects via USB • Performs E-‐Stop not disable –Robot must be rebooted after E-‐stop –Same as the E-‐Stop on the field –Space Bar acts as disable • Must be connected for robot to be enabled –This may be bypassed
10
The Stop Button
![Page 11: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/11.jpg)
11
Integrated Dashboard The dashboard data may be re-‐directed to another computer
The top half of this display can easily be customized
![Page 12: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/12.jpg)
12
• Use the User Message Box
• Use the Dashboard.ctr (The Low Dashboard Data VI)
• Use the High Dashboard Data VI
![Page 13: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/13.jpg)
13
• There is a User Message Box where one line messages can be sent from the robot to the DS
Here 2 messages in lines 1 and 2 are written in the “User Messages” box. Error messages can be included
Any Sensor 2.34 Any Sensor 1.23
Use the “User Message.vi
![Page 14: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/14.jpg)
14
• Recommendations that might be included in your message box:
ü The version # of the Robot software perhaps with the most recent modification ü The battery voltage and estimated drive time left
![Page 15: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/15.jpg)
15
Use the Dashboard Datatype.ctl to send simple data to the Dashboard from the Robot using the “Build DashBoard Data.vi”, specifically the “Set Low Priority Dashboard Data.vi”
Open the “Dashboard datatype.ctl from the Project Explorer
![Page 16: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/16.jpg)
16
Adding new controls to the .ctl
Add a new control or controls to the .ctl and save it.
![Page 17: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/17.jpg)
17
The rest of the process is fairly complex and would take up more time than we have, so visit the website for a complete step by step tutorial: http://decibel.ni.com/content/docs/DOC-‐8862
![Page 18: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/18.jpg)
18
• A more flexible and simpler method is to use the “Set High Priority Dashboard Data.vi”
•
![Page 19: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/19.jpg)
19
Step 1 Example Block Diagram of a Robot application.
In 2010 there were two SubVIs available to transfer User data to the DS. We Use the High Priority SubVI for this example. Open the SubVI for Step 2
![Page 20: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/20.jpg)
20
Step 2 Block Diagram of the Build Dashboard Data HI SubVI
All User data elements that are to be transferred to the DS are “Bundled” and the result “Flattened to a String” Then that String is sent to a Special SubVI called the “Set High Priority Dashboard Data” that is basically a memory function Note that the inputs can be local variables, global variables or simply hardwired to the SubVI
![Page 21: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/21.jpg)
21
Step 3
Typical Block Diagram of a Robot application.
Create a Constant of the output of the Bundle. This will provide a “DataType” or “Image” to be used later in the Unflatten from String process in the DS application The DataType for this example looks like this. Note that this constant would be cut from this block diagram and pasted into the DS application.
![Page 22: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/22.jpg)
22
An example Front Panel for a Custom Dashboard – The Sensor Panel Tab
In this particular example 4 ultrasonic sensors are displayed (note that the bar indicators are Log scaled from 4 inches to 120 inches), 5 kicker strength commands, a gyroscope reading, a ball locator (from 2 photoelectric sensors) and a real-‐time image of the target are displayed.
Step 4
![Page 23: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/23.jpg)
23
An example Front Panel for a Custom Dashboard – The Misc Data Tab
This tab displays data from modules in 2 slots, the IP address of the robot, and strip charts showing the Joystick X, Gyro, and Target information
![Page 24: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/24.jpg)
24
Another example Front Panel for a Custom Dashboard – The Drive Panel Tab
![Page 25: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/25.jpg)
25
Another example Front Panel for a Custom Dashboard – The Values Panel Tab
![Page 26: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/26.jpg)
26
Step 5 Example Block Diagram showing the extraction of the User data from the Robot.
This is a portion of the code used to display on the dashboard the User data from the robot Note that the application receives a UDP transmission, and unflattens the string using the datatype (image) that was created in the robot application and unbundled to provide the 5 front panel indicators The video display is not shown here for clarity
![Page 27: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/27.jpg)
27
Step 6 On the DS, Login to the Developer Account or bring the project over from the development laptop to create an exe file. Note that these steps are for a new exe only. Note that in this example the VI we are building the exe file for is “Dashboard Main.vi”
• On the Project Explorer Screen, right click on Build Specifications -‐> New -‐> Application (EXE) this will bring up the Properties screen
![Page 28: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/28.jpg)
28
Note that if one or more custom Dashboards already exist, simply “Build All” and that will complete the process except perhaps for being sure that the ini file is corrected (see a later slide)
![Page 29: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/29.jpg)
29
In the Properties Screen, Information list box “Target Filename" -‐ give it something meaningful, e.g., “Dashboard Team 1510 2010.exe” Also it is advisable to change the “Build specification name” to be the same name Note that for an existing file, right-‐clicking on the Properties selection brings up the same screen
![Page 30: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/30.jpg)
30
Click on "Build" at the bottom to create the exe. After it is built, press Done
In the Category list box click on "Source Files“ and Click on "Dashboard Main.vi“ and Click on the right pointing arrow that will highlight. You should see Dashboard Main.vi appear on the right hand side under • "Startup VIs"
![Page 31: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/31.jpg)
31
When it's done building go to the Destinations list box. With this example it will look like this: C://Documents and Settings\My Documents\LabVIEW Data\builds\2010 Game Dashboard Project\ Dashboard Team 1510 2010
![Page 32: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/32.jpg)
32
Navigate to C:\Program Files\FRC Dashboard and Paste all three files to that directory
Clicking on this button shows that three files have been created: Dashboard Team 1510 2010.aliases, .exe, .ini. Then navigate to C:\Documents and Settings/Developer//My Documents/LabVIEW Data/builds/2010 Game Dashboard Project//Dashboard Team 1510 2010 and Copy all 3 files
![Page 33: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/33.jpg)
You'll see a line: DashboardCmdLine=""C:\\Program Files\\FRC Dashboard\\Dashboard.exe"“ then Change the name of the Dashboard.exe to : Dashboard Team 1510 2010.exe then Save and exit the file. Note do this only if the name has changed Login to the Driver account (Windows Logo+L) to start up the new dashboard and see if it works. 33
Finally, go to: C:\Documents and Settings\All Users\Shared Documents
Make a backup copy of the file: FRC DS Data Storage.ini Open and edit the file: FRC DS Data Storage.ini in Notepad
![Page 34: First fare 2011 creating custom dashboards with labview](https://reader033.fdocuments.in/reader033/viewer/2022052820/54924c05b479597e6a8b58ac/html5/thumbnails/34.jpg)
Dennis C. Erickson - [email protected]