First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing...
-
Upload
oresti-banos -
Category
Science
-
view
19 -
download
0
Transcript of First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing...
![Page 1: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/1.jpg)
First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth VideoUCAmI 2016 (Las Palmas de Gran Canaria, Spain)
Carlos Bailon1, Miguel Damas1, Hector Pomares1 and Oresti Banos2
1Department of Computer Architecture and Computer Technology, CITIC-UGR Research Center, University of Granada, Spain
2Telemedicine Cluster of the Biomedical Signal and Systems Group, University of Twente, Netherlands
![Page 2: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/2.jpg)
![Page 3: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/3.jpg)
Knee alignment• Grade of alignment of the hip, knee and ankle joints.• Commonly used as a risk indicator of many biomechanical
injuries related to knee joint when measured during the performance dynamic tasks.
Anterior Cruciate Ligament (ACL) injuriesPatellofemoral Pain Syndrome (PFPS)
Potential misalignments during dynamic exercises are the most common injury mechanisms.
![Page 4: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/4.jpg)
Quantification of knee alignmentProjection of the angle formed by the hip, knee and ankle joints over the frontal plane of the body.
Frontal Plane Projection Angle
(FPPA)Wilson et al. “Core strength and lower extremity alignment during single leg squats” Medicine & Science in Sports & Exercise (2006)
![Page 5: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/5.jpg)
Key limitations of existing techniques for FPPA measuring
Inertial sensor-based systems
3D motion tracking video systems
2D offline video analysis
Accurate 3D rotationsPossible motion restrictionNon-deliberated sensor displacement
Tridimensional motion tracking
High sampling rateNeed of high number of camerasCostly and space demanding
One camera needed
Portable and easy-to-use equipmentElevated time for analysisProne to human errors2D analysis
![Page 6: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/6.jpg)
Objectives of the project• Automatic estimation of FPPA during the
performance of dynamic tasks (ideally any 2D biomechanics angle)
• Single-camera solution.
• No external light sources.
• Inexpensive and easy-to-use system.
• Real-time visualization of the FPPA.
• Automatic analysis of the data.
![Page 7: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/7.jpg)
Overview of the proposed system
![Page 8: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/8.jpg)
Why do we use markers?Although Kinect is well-known for being a markerless system, we introduce the tracking of three retro-reflective markers.
This method increases the accuracy of the pose estimation algorithm of Kinect and allows for tracking points that are not necessarily joints.The blue line shows the data registered during a single leg landing using markers.
The red line shows the data registered using the Kinect pose estimation algorithm.
RMSE = 8.498º
![Page 9: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/9.jpg)
Reflective markers tracking• Kinect’s depth sensor
captures the infrared intensity value for each pixel of the image (512 x 424 resolution).
• An empirical intensity threshold (high-pass filter) is used to select candidate marker’s pixels.
• Kinect’s pose estimation algorithm is used to classify each marker position.
• Retro-reflective elements not belonging to a marker are ignored.
• Markers coordinates are computed as the midpoints of the selected pixel’s cloud.
![Page 10: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/10.jpg)
Application
![Page 11: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/11.jpg)
Application
![Page 12: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/12.jpg)
Experimental results
High concordance among the measurements Proposed approach saves up to 10 minutes per
assessed subject
Comparison between Kinovea (2D offline analysis tool, expert oriented) and the proposed system. FPPA evaluated for 10 healthy subjects from a professional football team
![Page 13: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/13.jpg)
Conclusions• Proposed a novel system to perform an
automatic estimation of dynamic FPPA, by a single-camera, cost-effective and portable solution.
• The system uses a depth sensor to track the position of three retro-reflective markers attached to the subject’s hip, knee and ankle joints.
• Designed a user interface which simplifies the expert’s routine and expedites the analysis of the results.
• Experimental results show the interrater reliability of the proposed system, as well as the limitations of the 2D analysis (limited joint rotation measurement).
![Page 14: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/14.jpg)
THANKS!
![Page 15: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/15.jpg)
Application description
![Page 16: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/16.jpg)
Application implementation
![Page 17: First Approach to Automatic Measurement of Frontal Plane Projection Angle During Single Leg Landing Based on Depth Video](https://reader035.fdocuments.in/reader035/viewer/2022062503/58cf1fb51a28abc05f8b5d37/html5/thumbnails/17.jpg)
Data storageLocal database engineWhy?
• On-disk database file.• Not very large dataset.• No concurrent writers.• Data easily exported to CSV files for external
analysis.
Data is stored in two tables, differentiating patient personal information and data collected. Both tables are related by a personal ID.