FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ...

8
SAID. DONE! FIRE PROTECTION WATER MIST SYSTEM SHIPBUILDING

Transcript of FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ...

Page 1: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

SAID. DONE!

FIRE PROTECTION WATER MIST SYSTEM

SHIPBUILDING

Page 2: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

The KJ FireOff® Water Mist System

The special conditions at sea mean that safety is an incredibly important issue for ships. Ships are subject to a whole range of fire risks, which means fire protection on board has to be very effective . Suppression in an early phase in case of a fire, is absolutely imperative.

Since more than 100 years sprinkler-systems are in use to detect fires in an early stage and to effectively suppress fires as soon as possible. Over many years the detection and release was initiated through a soldered strut. Today a glass-bulb, filled with a fluid, which expands at calculable temperatures and bursts, the bulb releases the suppression-process.

Classical fire sprinklers with so called deflectors for water distribution, produce large water drops. So the water consumption is relatively large. Also water damage is an issue in case of a fire. A very valuable solution is water mist, which reduces the water consumption heavily. The drop-size is just a small part compared to sprinklers. There are several methods to generate water mist.

KJ FireOff Water Mist is produced just over the normal pump pressure based on the patented unique design of the nozzles.

KJ FireOff Water Mist Systems has an excellent performance in the field of fire protection.

KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM

SAID. DONE!

Power Consumption (kW)

System Pressure (bar)

Water Consumption l/min/m2

KJ FireOff Water Mist System Regular Sprinkler High Pressure Sprinkler

Comparison of water mist and standard sprinkler

Page 3: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

Suppression of Water Mist is always based on three elements

Cooling of surroundings and of combustion gas. The little water droplets have just a small mass compared to the droplets outer surface . This makes it easy for the fire to heat up and evaporate water. This process needs a lot of energy. The activation of KJ FireOff Water Mist, does this way provide high local cooling, which will reduce radiant heat of a fire and the intensity of hot combustion gasses. The activation of KJ FireOff Water Mist, does this way reduce the risks of a “flashover”. A dominant effect is being achieved while water evaporates around the flame zone, providing large cooling and an inert atmosphere smothering the combustion process. 1 liter of water is equivalent to 1700 liter of water vapor.

The heat of fire causes small water droplets to evaporate into steam. Water vapors behavior is similar to an inert gas, and does locally reduce the oxygen concentration.

The KJ FireOff Water Mist System is very effective in small enclosures like cabins.

The suppression process in case of KJ FireOff Water Mist is based on three elements and their interaction:

• Cooling

• Radiant heat reduction

• Local oxygen inerting

Spacing Application InstallationHeight Product

Acc

om

od

atio

n/P

ublic

Sp

aces

16 m2 Cabins, pendent Nozzle

2,50 m(2,0 m to wall)

KJ FireOff® OHM-L1(Picture 1 f.l.)

16 m2 Shops/Restaurants other Public Spaces

2,00 m – 5,00 m KJ FireOff® OHM-L2(Picture 1 f.l.)

18 m2 Cabins, Sidewall Nozzle

2,50 m (0,10 – 0,20 m beneath Ceiling Surface)

KJ FireOff® OHM-SWC(Picture 2 f.l.)

4,5 m2 Corridors & Stairways

2,50 m (0,75 to wall)

KJ FireOff® OHM-CO(Picture 1 f.l.)

16 m2 RoRo, Shopping, Storage

2,50 m KJ FireOff® OHM-PX1(Picture 1 f.l.)

Engine room TF

9 m2 Full Protection TF

< 10 m KJ FireOff® MK-6_FP_E(Picture 3 f.l.)

Engine room LA

2,35 m2 Local Application < 11 m KJ FireOff® MK-6_LP_E(Picture 3 f.l.)

RoRo 12,25 m2 RoRo Truckdeck 5,00 m(1,75 m to wall)

KJ FireOff® OHM-OPX1(Picture 4 f.l.)

Bilges Spacing 0,5 m Bilgesmax. Height 0,75 m

0,75 m KJ FireOff® MK-1(Picture 6 f.l.)

Galley Ducts Galley Ducts Square L= 0,6m H=0,3m max. Round d= 0,57 max.

KJ FireOff® MK-1(Picture 6 f.l.)

Bilges 1,31 m2 Max. Bilge Height 1,1 m

0,35 m–0,37m KJ FireOff® MF-1(Picture 6 f.l.)

Deep Fat Fryer

Deep Fat Fryer Over Fryer: 1–1,5 m

KJ FireOff® MBM-1(Picture 5 f.l.)

KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM

SAID. DONE!

Page 4: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

1

5

2

3

4

7

6

8

Page 5: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

9

KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM

SAID. DONE!

For all applications in marine fire protection business

1 Bridge Special supervision and control functions. All information are available with our alarm panel

2 Public Spaces Restaurants, Shops, Bars, Entertainment areas are protected with automatic FireOff OHM nozzles

3 Corridors Corridors and staircases are important as escape routes. And have to be protected with the KJ FireOff OHM CO program

4 Accomodation Automatic detection and mist suppression with KJ FireOff OHM-L1. With our KJ FireOff OHM-SWC also a horizontal sidewall version is available

5 Galley Here several different nozzles might be part of the design. KJ FireOff OHM-L2 will be used for the galley in total. For deep fat fryers KJ FireOff MBM-1. In galley ducts we use KJ FireOff MK-1

6 Storage Rooms Usualy will be protected by KJ FireOff OHM-PX1

7 Engine and Pumprooms Sections with highest fire risk. For Total Flooding KJ FireOff MK-6 FP. Local Application of hotspots with KJ FireOff MK-6 LA

8 Bilge Protected by KJ FireOff MK-1. Alternatively KJ FireOff N-Pipes pre assembled with nozzles

9 Offshore In the field of offshore platforms more or less the same rules and approvals are valid. Additionaly the risk of carbon hydrite fires has to be considered in the design

Picture: Original © Rockwool with friendly acceptance from Rockwool Technical Insulation

Page 6: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

One for all

KJ FireOff Water Mist System is excellent for all shipbuilding applications:

• Cruising Ships

• Ferrys, RoRo Vessels

• Cargo Ships

• Yachts

• Naval Vessels

• Offshore

KJ FireOff Water Mist is available for all typical fields of application:

• Accommodation and Public Spaces

• Engine Rooms TF and LA (Local Application)

• RoRo and Truck Decks

• Deep Fat Fryers

• Galley Ducts

• Bilges

• Balcony solutions (drenchers)

Every field of application has different requirements to the system. Open nozzles or automatic nozzles with glass bulb. Cabins and public spaces will be equipped with automatic nozzles. The KJ FireOff OHM nozzles with super fast response glass bulb will detect a fire and release to suppress the fire immediately. KJ FireOff automatic nozzles also fulfill highest requirements in terms of esthetical performance. Rosette and cover-plate are available in all common RAL colours.

For Total Flooding and Local Applications of hotspots open KJ FireOff MK-6 nozzles as a part of a dry system are the rule.

The KJ FireOff System is completely approved including all components:

• Nozzles (Sprinklers)

• With/without glass-bulb for wet- and dry pipe systems

• Pipe systems

• Control valves and special valves

• Pumps and water supply

• Alarm panel/control-system

KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM

SAID. DONE!

Page 7: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

energysaver

KJ

FIRE PROTECTIO

N

• EX

CE

S

SIVELY LOW-CUR

RE

NT

Main customer benefits at a glance

Customers have reasons for being completely satisfied:

• Ease of installation compared to competition products

• Ease of maintenance for your crew

• Based on this clear cost advantages compared to competition products

• Clear weight advantages

• 40 % lower energy need

• No water additives

• In accommodation esthetical nice semi concealed design. Rosettes and cover-plates available in all RAL colours

• The KJ FireOff OHM automatic is available in a side wall version

KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM

SAID. DONE!

Page 8: FIRE PROTECTION WATER MIST SYSTEMk-j.de/pdf/schiffbau/KJ_FireOff_WaterMistSystem_8E.pdf9 KJ FIREOFF® HIGHLY EFFECTIVE WATER MIST SYSTEM SAID. DONE! For all applications in marine

© Bruce Thomas

SAID. DONE!

FIRST STEPSARE ALWAYS WELCOME

Knaack & Jahn Schiffbau GmbHUffelnsweg 1020539 Hamburg / Germany

Phone +49 (0)40 / 78 12 93-0Fax +49 (0)40 / 78 12 93-10

[email protected]

AFTER ORDER PLACEMENT, WE ARE AT YOUR COMMAND

Some of our references

Crist S.A. – Jack up Barge Thor – Jack Up Vessel Innovation – Jack Up Vessel Vidar

Norderwerft Repair GmbH – River Allegro*

Den Breejen Shipyard – Avalon Impression* – Avalon Illumination* – Avalon Tapestry II* – Avalon Tranquility II* – Scenic Jade* – Scenic Opal* – Scenic Jasper* – Emerald Sun* – Emerald Dawn*

De Hoop International – Scenic Gem*

Nobiskrug GmbH – Yacht NB 777 – Yacht NB 778 – Yacht NB 779 – Yacht NB 780 – Yacht NB 781 – Yacht NB 782 – Yacht NB 783

Howaldtswerke – HDW – Yacht NB 422

*River Cruise Vessel