Fire-Lite BB-R Data Sheet

3
DF-51636 — Page 1 of 2 GENERAL KMS Series bells are low-current, audible signaling devices for use in fire alarm systems or other signaling applications. FEATURES Under-d ome desi gn. Avail able in th ree gong sizes (6", 8", and 10" diameter). Low operati ng current. Low “ki ck” cur rent. • Indoor/outdoor installation. Mount to standar d 4" s quare electri cal bo x. • Compli es w ith UL 864. OPERATION The KMS Series bells use a low-current, high efficiency DC motor to drive the striker. All DC models are polar- ized for use with supervision circuitry. The operating mechanism is completely enclosed in a cast aluminum base.  APPLICATIONS KMS Series bells are ideally suited for almost any kind of alarm signal ing application. They can be used in schools, factories, office buildings, or private residences. Their low current consumption means additional savings on standby power. CONSTRUCTION Each bell gong is made of steel finished in red enamel. The striker is also made of steel, and the mechanism housing is made of cast aluminum. Optional backboxes are of steel finished with red enamel to match the gong. INSTALLATION Bells may be installed on a wall surface or semi-flush. A weatherproof backbox (WBB) also permits installation on an exterior wall surface. S748 BSA CS47021 7135-0028:117 0M6A4.AY 1070-80-SA KMS Series  Alarm Bells March 1, 1999 G-700 Section: Audio/Visual Devices California State Fire Marshal This document is not intended to be used for installat ion purposes. We try to keep our product information up-to-dat e and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more informatio n, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627- 3473, Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299 WEB: www.firelite.com

description

Buy the Fire-Lite BB-R at JMAC Supply.https://www.jmac.com/Fire_Lite_BB_R_p/fire-lite-bb-r.htm?=scribd

Transcript of Fire-Lite BB-R Data Sheet

Page 1: Fire-Lite BB-R Data Sheet

7/17/2019 Fire-Lite BB-R Data Sheet

http://slidepdf.com/reader/full/fire-lite-bb-r-data-sheet 1/2

DF-51636 — Page 1 of 2

GENERALKMS Series  bells are low-current, audible signaling

devices for use in fire alarm systems or other signaling

applications.

FEATURES

• Under-dome design.

• Available in three gong sizes (6", 8", and 10" diameter).

• Low operating current.

• Low “kick” current.

• Indoor/outdoor installation.

• Mount to standard 4" square electrical box.

• Complies with UL 864.

OPERATION

The KMS Series bells use a low-current, high efficiency

DC motor to drive the striker. All DC models are polar-

ized for use with supervision circuitry. The operating

mechanism is completely enclosed in a cast aluminum

base.

 APPLICATIONS

KMS Series bells are ideally suited for almost any kind

of alarm signaling application. They can be used in

schools, factories, office buildings, or private residences.

Their low current consumption means additional savings

on standby power.

CONSTRUCTION

Each bell gong is made of steel finished in red enamel.

The striker is also made of steel, and the mechanism

housing is made of cast aluminum. Optional backboxes

are of steel finished with red enamel to match the gong.

INSTALLATION

Bells may be installed on a wall surface or semi-flush. Aweatherproof backbox (WBB) also permits installation

on an exterior wall surface.

S748

BSA 

CS47021

7135-0028:117

0M6A4.AY1070-80-SA

KMS Series Alarm Bells

March 1, 1999 G-700

Section: Audio/Visual Devices

California

State FireMarshal

This document is not intended to be used for installat ion purposes. We try to keep our product

information up-to-date and accurate. We cannot cover all specific applications or anticipate all

requirements. All specifications are subject to change without notice. For more information,

contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-

3473, Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299

WEB: www.firelite.com

Page 2: Fire-Lite BB-R Data Sheet

7/17/2019 Fire-Lite BB-R Data Sheet

http://slidepdf.com/reader/full/fire-lite-bb-r-data-sheet 2/2

Page 2 of 2 — DF-51636

Notes: 

* Sound Pressure Level (SPL) measured in accordance

with UL Standard 464. UL Standard 464 requires that:

• The units be measured in a reverberant room

qualified for pure tones under the methods for

Determination of Sound Power Levels of SmallSources in Reverberation Rooms, ANSI S1.21-

1972.

• The units be capable of providing a sound out-

put of not less than the sound level provided by

an omnidirectional source having an A-weightedsound pressure level equal to the level speci-

fied on the unit marking and not less than 75

decibels in any case.

PRODUCT LINE INFORMATION

51636t1.tbl

     2     2     5     2     d     i    m     1 .     t     i     f

Model Number Gong SizeSPL Measurementat 10 ft. (3.048 m)*

Rated InputVoltage

Rated Current(mA)

MinimumStarting Voltage

 KMS-6-24 6" (15.24 cm) 85 dB 24 VDC 30 12 VDC

 KMS-8-24 8" (20.32 cm) 85 dB 24 VDC 30 12 VDC

 KMS-10-24 10" (25.40 cm) 85 dB 24 VDC 30 12 VDC

 WBB  Surface-mount weatherproof backbox, metal, red.

 BB-R  Standard 4" square electrical backbox - red enamel finish.

 SFP-R  Semiflush plate, mounting trim, metal, red.

 MP-SF/R  Semiflush plate, mounting trim, plastic, red.