FIRE BEHAVIOR

94
3S Fire LLC. FIRE BEHAVIOR 1

description

FIRE BEHAVIOR. TACTICAL TRIANGLE. FIRE BEHAVIOR. BUILDING CONSTRUCTION. TACTICAL DECISION. CAPABILITIES AND LIMITATIONS. Science. A branch of knowledge or study dealing with a body of facts or truths systematically arranged and showing the operation of general laws. - PowerPoint PPT Presentation

Transcript of FIRE BEHAVIOR

Page 1: FIRE BEHAVIOR

3S Fire LLC.

FIRE BEHAVIOR

1

Page 2: FIRE BEHAVIOR

3S Fire LLC.

2

Page 3: FIRE BEHAVIOR

3S Fire LLC.

TACTICAL TRIANGLE

3

TACTICAL DECISIONFIR

E B

EH

AVIO

RBU

ILDIN

G

CO

NSTR

UC

TION

CAPABILITIES AND LIMITATIONS

Page 4: FIRE BEHAVIOR

3S Fire LLC.

Science A branch of knowledge or study

dealing with a body of facts or truths systematically arranged and showing the operation of general laws.

4

Page 5: FIRE BEHAVIOR

3S Fire LLC.

5

Page 6: FIRE BEHAVIOR

3S Fire LLC.

Fire Fighters that use scientific factsEarn CredibilityCan Defend their Actions LegallyTeach to Referenced/Documented

Standards and PracticesCan Protect Themselves Are Fire Fighter’s that Think for

Themselves

6

Page 7: FIRE BEHAVIOR

3S Fire LLC.

Scientific Testing ProvidesCommon standards used by manufacturers

for designMeasurable limits and capabilitiesPoints of reference to base tactical and

strategic decisionsFire Fighting Facts that are referenced and

documentedFacts for lawyers

7

Page 8: FIRE BEHAVIOR

3S Fire LLC.

Science = Life Measurable

Documented

Justifiable

8

Page 9: FIRE BEHAVIOR

3S Fire LLC.

FIRE BEHAVIOR

9

A FOUNDATION BUILT ON SCIENCE

Page 10: FIRE BEHAVIOR

3S Fire LLC.

UNDERSTANDING OUR ENEMY

10

GETS RID OF THE BOOGIE MAN

Page 11: FIRE BEHAVIOR

3S Fire LLC.

A BASE LINE PERSPECTIVE11

GETS US ALL ON THE SAME PAGE

Page 12: FIRE BEHAVIOR

3S Fire LLC.

FIRE BEHAVIOR SCIENTIFIC FACTSFire Triangle – Fuel, Air, HeatASTM E-119 TestStandard Time Temperature Curve (1916)Ordinary fuel load – Btu’s - configurationBtu’s in a cubic ft. of air – rate?Flame spreadSmoke expansion – Charles LawFlammable Range of smoke (CO)Temperature at the floorReading the heat in the smokeThermal BalanceRate of Change

12

Page 13: FIRE BEHAVIOR

3S Fire LLC.

FIRE TRIANGLE/TETRAHEDRON

13

Understanding the science within the fire triangle/tetrahedron builds your tactical & strategic

perspective on a scientific foundation, that verifies your experience and the experience of others.

Page 14: FIRE BEHAVIOR

3S Fire LLC.

FUELThree States of

Matter:1. Solid2. Liquid3. Gas

14

Page 15: FIRE BEHAVIOR

3S Fire LLC.

FUELTwo Categories:Hydrocarbon Based: Gasoline Diesel Fuel Oil Plastics, etc

15

Page 16: FIRE BEHAVIOR

3S Fire LLC.

FUEL

Cellulose Based: Wood Paper Cotton Natural Fiber

16

Page 17: FIRE BEHAVIOR

3S Fire LLC.

COMMON FUELSMost Common Fuels

Contain:1. Carbon2. Hydrogen3. Oxygen

17

Page 18: FIRE BEHAVIOR

3S Fire LLC.

SOLID FUELSThe Initiation of Combustion Requires Phase

Conversion to a Gaseous State by HeatingFuel Gases are Evolved from Solid Fuels by

PyrolysisThe Speed of Pyrolysis is Affected by it’s

Arrangement and Surface Mass Ratio

18

Page 19: FIRE BEHAVIOR

3S Fire LLC.

SOLID FUELS

Ignition Temp. 451 Deg. FOrdinary Combustibles- 8,000 btu’s per lb.Hydrocarbon (Plastics)- 16,000 btu’s per lb.

19

Page 20: FIRE BEHAVIOR

3S Fire LLC.

20

Page 21: FIRE BEHAVIOR

3S Fire LLC.

21

Page 22: FIRE BEHAVIOR

3S Fire LLC.

Air - Ventilation

Fuel controlled fire, the growth is determined by the amount of available fuel with an abundant supply of air

When burning in the open or early stage of compartment fire, where there is excess air available

22

Page 23: FIRE BEHAVIOR

3S Fire LLC.

Air - Ventilation

Ventilation controlled fire, the growth is determined by the amount of available air

A ventilation controlled fire occurs when there is not enough air to burn the materials being pyrolyzed

23

Page 24: FIRE BEHAVIOR

3S Fire LLC.

Air – Ventilation - Profile

Based on ASTM- E119 testsRatio of ventilation opening to floor area

involvedOrdinary Development =10% to 15%

ventilation to floor area ratio Accelerated Development = More than 15%

ventilation to floor area ratioVentilation Controlled = Less than 10%

ventilation to floor area ratio

24

Page 25: FIRE BEHAVIOR

3S Fire LLC.

THORTON’S RULEThe Heat of Combustion per kg of O2

Consumed is Nearly Constant for Most Organic Fuels, 13.1 kg per Gram of O2 Consumed

Most fires We Go to Are Ventilation ControlledThis Means that Hydrocarbon based Fuels

and Cellulose based Fuels have About the Same (hrr) Heat Release Rate

Once the Fire is No Longer Ventilation Controlled, the Hydrocarbon Based Fuels can Release Almost 3 Times the (hrr) Energy as Cellulose based

25

Page 26: FIRE BEHAVIOR

3S Fire LLC.

THORTON’S RULE

26

Page 27: FIRE BEHAVIOR

3S Fire LLC.

27

Page 28: FIRE BEHAVIOR

3S Fire LLC.

28

Page 29: FIRE BEHAVIOR

3S Fire LLC.

29

Page 30: FIRE BEHAVIOR

3S Fire LLC.

LIQUID FUELSFlammable Liquids Like Gasoline, Ignition

Temp. Under 100 Deg. FCombustible Liquids Like Diesel, Ignition

Temp. Above 100 Deg. F125,000 to 140,000 btu’s per GallonMost Flammable and Combustible Liquids

Will Float on Water as They Have a Lower Specific Gravity than Water

Polar Solvents and Alcohol Will Mix With Water

30

Page 31: FIRE BEHAVIOR

3S Fire LLC.

31

Page 32: FIRE BEHAVIOR

3S Fire LLC.

GAS FUELSCompressed Gas Fuels like Propane and

Natural Gas, or Carbon Monoxide and Hydrogen

Propane -2,500 btu’s per cu/ftNatural Gas -1,100 btu’s per cu/ftCarbon Monoxide – 323 btu’s per cu/ftHydrogen – 325 btu’s per cu/ftRequires No Pre Heating to Ignite

32

Page 33: FIRE BEHAVIOR

3S Fire LLC.

33

Page 34: FIRE BEHAVIOR

3S Fire LLC.

British Thermal UnitsBTU’s WE LOVE EM!

Quantifies heat release rate for building construction strength.

Quantifies heat release rate for fire development

Quantifies water1 BTU is the amount of heat required to raise a pound of water 1 degree fahrenheit from 60 degrees fahrenheit.

Page 35: FIRE BEHAVIOR

3S Fire LLC.

ASTM E-119

POINT “A”A Place to START!

35

Page 36: FIRE BEHAVIOR

3S Fire LLC.

ASTM - E119Methods of Fire Tests of Building Construction and MaterialsHelps to build a SCIENTIFIC perspective for

fuel loading and configuration Still used today -Standard Time Temperature

Test (since 1918)Helps to build a SCIENTIFIC perspective for

HEAT IN YOUR WORK PLACE!Our battlefield the fire structure is built on

this testing

Page 37: FIRE BEHAVIOR

3S Fire LLC.

37

Ordinary fuel load is 8,000 btu’s per pound,10 pounds per square foot. 80,000 btu’s per square foot

1 Hour FireWood, paper, textiles

l

Page 38: FIRE BEHAVIOR

3S Fire LLC.

38

Minimum size for test specimensFloors and Roofs 160 squ. Ft.Partition and Walls are 380 squ. Ft.

Length x Width x Height = Cubic Feet

8 x 10 x 8 = 640 cu. ft.

The Box

Page 39: FIRE BEHAVIOR

3S Fire LLC.

39

Furnace test replicates the wood crib test fuel load’s heat release rate of 8,000 btu’s per pound at 10 pounds per square foot. 80,000 btu’s per square foot for a 1 Hour Fire.

Page 40: FIRE BEHAVIOR

3S Fire LLC.

STANDARD TIME TEMPERATURE CURVE (1917-1918)

Temperatures at Ceiling5 minutes 1000 deg. F. TP - ignition source10 minutes 1300 deg. F. 15 minutes 1400 deg. F. 20 minutes 1460 deg. F. 25 minutes 1510 deg. F. 30 minutes 1550 deg. F.45 minutes 1638 deg. F.TP- wired glass60 minutes 1700 deg. F.

40

1 hour 1700 deg. F. 80,000 btu’s/square foot2 hour 1850 deg. F3 hour 1920 deg. F. 4 hour 2000 deg. F. 8 hour 2300 deg. F.

Page 41: FIRE BEHAVIOR

3S Fire LLC.

ASTM E-119Pass/fail criteria are based upon the peak

temperature attained at the back of the test article and/or whether or not the test article collapses or distorts in a fashion that allows hot gases to escape (and in the case of E119, whether the wall can withstand the pressure of a hose stream).Wall & Floor Assemblies: 325 deg. F. at any one point or 250 deg. F. overall•FF Practical Tactical – non burning side touch.Structural Elements Supporting the Load: 1200 deg. F. at any one point and 1000 deg. F. overall•FF Practical Tactical – water sheen.

Page 42: FIRE BEHAVIOR

3S Fire LLC.

NFPA Surveyed Fuel LoadsType of Room Contents

lbs. per square footBtu’s

per square foot

Bedroom 4.3 34,400

Living Room 3.9 31,200

Dining room 3.6 28,800

Kitchen 3.2 25,600

Family room 2.7 21,600

Nursing home Pt. room 2.6 20,800

Hospital Pt. room 1.2 9,600

ASTM-TEST (STTC) 10 80,000

Page 43: FIRE BEHAVIOR

3S Fire LLC.

Peak Development for Ordinary Fire is 4,8oo (Vito)

BD

FO

Fully Developed4,800 - 5,000 btu’s /squ.

ft./min.129 – 135 cfm

DecayGrowth

Page 44: FIRE BEHAVIOR

3S Fire LLC.

ASTM E-119 Test load vs. N.F.P.A. surveyed load

44

Real World Half the Load!

5 lbs/sq.ft.

10 lbs/sq.ft.

Page 45: FIRE BEHAVIOR

3S Fire LLC.

What about plastics? 16,000 btu’s per pound!

Remember half the load compared to the test loadLess Mass: plastic is stronger per pound than

woodVentilation effect in structures

Incomplete combustionWhat is the air flow rate?

How much water do you really need?

How much air does the fire need?

Page 46: FIRE BEHAVIOR

3S Fire LLC.

Factors that affect Fire Development

Surface to Mass Ratio Location of the fuel (center , wall, corner) Size, number, and arrangement of the vent

openingsVolume of the boxCeiling Height of the box 8’Target Fuels

46

Page 47: FIRE BEHAVIOR

3S Fire LLC.

Surface to Mass RatioThe more air that reaches the surface of the

fuel the higher the HRR. The lighter the fuel the faster the HRR.

Page 48: FIRE BEHAVIOR

3S Fire LLC.

Location of the Fire in the BoxFires in the middle of the room entrains air

and are cooler.Fire against the wall is 50% higher HRRFire in the corner is 70% higher HRRThe walls reflect heat back to the fire

Page 49: FIRE BEHAVIOR

3S Fire LLC.

You & Your EnvironmentVolume of the box 8’x20’x8’=1,280 cu’In a room of a 160 square feet (8x20, 16x10) a

fuel load of 16 square feet (4x4)at 10 lbs per square foot (2) upholstered chairs, That would fill the box with incomplete combustion.Limited space for heat & conversion space

The same fire in Costco would be complete combustion and you would be able to walk right up to the fire.Plenty of room for conversion and convected heat

Page 50: FIRE BEHAVIOR

3S Fire LLC.

Ceiling Height8’ ceilings - Residential StructuresAllow for horizontal spread of 40% of the heat of

the fire by convection. (touch)Heat is radiated to the other target fuels and the

floor from the convected heat layer trapped below the ceiling

When convected gas ignites and can add an additional 40% of the fires heat by radiation (light)

In general, during a growth stage fire, when 500 degrees F. is reached at mid wall, zero visibility opposite wall from fire, and off gassing at the floor, flashover is possible.

Page 51: FIRE BEHAVIOR

3S Fire LLC.

Target FuelsThe fire spreads to other target fuel in the

box hot to cold40% radiation

Light source40% convection

Suspended gas heat20% conduction

Through a solid hot to cold

Page 52: FIRE BEHAVIOR

3S Fire LLC.

Ventilation Profile for Ordinary DevelopmentBased on ASTM - E119 testsRatio of ventilation opening to floor area

involvedOrdinary Development =10% to 15%

ventilation to floor area ratio Accelerated Development = More than 15%

to floor area ratioVentilation Controlled = Less than 10%

ventilation to floor area ratio

52

Page 53: FIRE BEHAVIOR

3S Fire LLC.

Air - VentilationOrdinary fire development needs a

minimum of 10 -15% of the floor area in ventilation openings not to exceed 25-30% related to the exposed fuel surface area.

53

Page 54: FIRE BEHAVIOR

3S Fire LLC.

54

Ignition Temperature of 4510 F

Ordinary fire development needs a minimum of 10 -15% of the floor area in ventilation openings (square foot of fire)

Page 55: FIRE BEHAVIOR

3S Fire LLC.

55

640 cubic feet of air = 23,680 BTU’s available

(for this moment in time)

23,680 BTU’s / 9,330 BTU’s = 2.53gallons

536 btu’s in a cubic ft of pure oxygen

21% Oxygen in Air with 7% of the 21% available for combustion

536 btu’s times 7% = 37 btu’s per cubic foot of air

How many btu’s per cubic foot of air?

Page 56: FIRE BEHAVIOR

3S Fire LLC.

56

Every increase of 459O F, Gas Volume Doubles

Charles’s Law – Volume of a given mass of gas is directly proportional to absolute temperature if pressure is kept constant. Every increase of 459 deg. F., Gas Volume Doubles

Page 57: FIRE BEHAVIOR

3S Fire LLC.

57

Page 58: FIRE BEHAVIOR

3S Fire LLC.

58

910O F Gas Volume Doubled

Page 59: FIRE BEHAVIOR

3S Fire LLC.

59

Page 60: FIRE BEHAVIOR

3S Fire LLC.

60

1000O F at 5 minutes STT

Page 61: FIRE BEHAVIOR

3S Fire LLC.

61

Page 62: FIRE BEHAVIOR

3S Fire LLC.

62

6 to 12” per second – Flame spread

Jet Flame vs. CO burning

1000O F at 5 minutes STT

Page 63: FIRE BEHAVIOR

3S Fire LLC.

63

Page 64: FIRE BEHAVIOR

3S Fire LLC.

64

1000O at 5 minutes

6” to 12” per second – Flame spread

Ref: NFPA 19th ed. Vol.1 chp.2 pg.106

CO Ignition Temp: 1128 deg. F.

Flammable Range: 12.5 – 74%

Btu’s per cubic foot: 323 btu’s

Page 65: FIRE BEHAVIOR

3S Fire LLC.

65

Page 66: FIRE BEHAVIOR

3S Fire LLC.

Flammable Range of Carbon Monoxide

Carbon Monoxide12.5% to 74%Ignition Temperature

1128 deg. F.

66

Page 67: FIRE BEHAVIOR

3S Fire LLC.

67

Page 68: FIRE BEHAVIOR

3S Fire LLC.

68

1000O at 5 minutes

6” to 12” per second – Flame spread

13.2 btu’s / sq. ft.

CO Ignition Temp 1128 deg. F.

Flam. Range 12.5 – 74%

30 ft./second

Flashover progressing in less than ONE minute

1.8 btu’s per sq. ft./ sec. Off gassing off the Floor

1.8 btu’s per sq. ft./sec. Radiating to the Floor

Opposite wall from fire - zero visibility - 500 deg. F. at mid wall

Page 69: FIRE BEHAVIOR

3S Fire LLC.

69

Page 70: FIRE BEHAVIOR

3S Fire LLC.

“ HOSTILE FIRE”Flashover

Backdraft

The box can only absorb a limited amount of heat.

70

Page 71: FIRE BEHAVIOR

3S Fire LLC.

Flashover - Science8 foot ceiling Zero Visibility Opposite Wall of the Fire500 deg. F. mid wall and Fire on the

Ceiling1.8 btu’s / second / sq. ft. of energy off the

ceiling radiating to the floor, bringing common combustibles to their ignition

temperatureThe structure is unable to absorb heat8 – 15 minutes to FLASHOVER

71

Page 72: FIRE BEHAVIOR

3S Fire LLC.

FLASHOVERWARNING SIGNS:Growth Stage FireExtreme Heat -1128 F.

at ceiling or 500 F. mid wall

Heat Stained Cracked Windows – 600 F.

Box can’t Absorb HeatHigh Velocity SmokeTurbulent Dense Smoke Inadequate VentilationVent Point Ignition

72

Page 73: FIRE BEHAVIOR

3S Fire LLC.

Life of the WindowClear WindowLight smoke, non – obscureMedium smoke, obscure, life concerns (12,500ppm

or 1.28% of CO)Medium smoke, obscure, condensation, room below

212 deg. F. life, (150 deg. F. not likely to exit into).Heavy smoke, obscure, heat stained without

moisture, room above 212 deg. F. life, (300 deg. F. can be lethal).

Heavy smoke, obscure, cracked, life?, (600 deg. F. single pane window failure) fire on ceiling

Page 74: FIRE BEHAVIOR

3S Fire LLC.

74

Page 75: FIRE BEHAVIOR

3S Fire LLC.

Life of The Window3 mm single pain float glass cracks at about

600 deg. F.4-6 mm single pain float glass cracks at about

800 deg. F.6 mm double glazed about 1100 F.Vinyl Frame Window failure 8-16 kw m2, the

window glass drops from frame

75

Page 76: FIRE BEHAVIOR

3S Fire LLC.

Life of The WindowTempered Plate Glass fails after flashover

about 1200 F., generally it will just shatterFire Resistive Glass failure 26 kw m2Wired Glass will generally fail and fall from

frame about 1638 deg. F.Correlate cracked or failed windows to fire

behavior, what’s going on in the box

76

Page 77: FIRE BEHAVIOR

3S Fire LLC.

77

Page 78: FIRE BEHAVIOR

3S Fire LLC.

78

Page 79: FIRE BEHAVIOR

3S Fire LLC.

79

Page 80: FIRE BEHAVIOR

3S Fire LLC.

N.F.P.A. Prediction of Flashover Method

Qfo=610(HkAsAv h2)1/2

80

Page 81: FIRE BEHAVIOR

3S Fire LLC.

BACKDRAFTBackdraft is triggered by O2 being

introduced to a pressurized “box” Yellowish-grey smoke Whistling Heat Stained Windows with Extreme

Heat “Sealed” containers Hot and Quiet

81

Page 82: FIRE BEHAVIOR

3S Fire LLC.

82

Page 83: FIRE BEHAVIOR

3S Fire LLC.

83

Page 84: FIRE BEHAVIOR

3S Fire LLC.

84

Page 85: FIRE BEHAVIOR

3S Fire LLC.

85

Page 86: FIRE BEHAVIOR

3S Fire LLC.

86

Page 87: FIRE BEHAVIOR

3S Fire LLC.

Door ProceduresCheck Fire FlowAssess Door as

Shield/ControlCheck for HEATCheck for PressureOpen door for VentilationFeel for HEAT LiftRead the Smoke directionLook & listen for life & fireAssess the “Rate of Change”

87

Page 88: FIRE BEHAVIOR

3S Fire LLC.

Rate of Change

Are conditions getting better, staying the same, or getting worse?

88

Page 89: FIRE BEHAVIOR

3S Fire LLC.

89

Page 90: FIRE BEHAVIOR

3S Fire LLC.

90

Page 91: FIRE BEHAVIOR

3S Fire LLC.

Thermal Balance

91

MAINTAIN THERMAL BALANCE

Page 92: FIRE BEHAVIOR

3S Fire LLC.

92

Page 93: FIRE BEHAVIOR

3S Fire LLC.

93

Page 94: FIRE BEHAVIOR

3S Fire LLC.

BETTER TO BE LUCKEY, OR GOOD?

94