Finite T-Series Top Loading Compressed Air Filters Finite/Top Loading... · up to 99.995%. This new...
Transcript of Finite T-Series Top Loading Compressed Air Filters Finite/Top Loading... · up to 99.995%. This new...
Parker Hannifin CorporationFiltration and Separation Division500 S. Glaspie St. Oxford, MI 48371
phone: 248 628 6400fax: 248 628 1850
www.cleancompressedair.com
Bulletin T SeriesPrinted in U.S.A. July 2010Copyright© Parker Hannifin Corporation 2010
Finite T-Series Top Loading Compressed Air Filters
Product Features and Benefits:Contact Information:
• Robust aluminum construction
• Removes up to 99.995% of oil, water, and solids from compressed air and other gases
• Lower maintenance costs
• Proprietary top threading element design for faster change-outs
• Continuously traps and drains liquids
• Increased production
New low-profile filter designed with OEM machine builders in mindThe Finite new patented top loading compressed air filter will remove solid and liquid contaminants at efficiencies up to 99.995%. This new design allows for easy element replacement due to the fact that the element threads into the top of the housing. These new filter housings have been designed to make element replacement faster, even in the most space challenged environments, thus reducing down time and increasing production volumes.
For space constrained installations
Applications:
• Refrigerated dryer protection
• Cold coalescing
•Usage in limited space
•Mounts easily inside cabinets
• General industrial
•OEM requirements
• Any application low to floor
Keeps refrigerated air dryers operating at full capacity.The top loading filters will protect the complex internal components of a re-frigerated dryer by removing compres-sor oil carryover, which accumulates over time, eventually compromising dryer operation. These filters are ideal for cold coalescing applications.
Since the element changes out through the top of the filter housing, there is no longer any need to disconnect the drain connections before removing the bowl to access the spent element. Once the assembly is installed, the inlet and outlet connections, along with the drain connections, need never be touched again.
Bulletin 1300-950/USA Decembrer 2010© 2010 Parker Hannifin Corporation
Parker Hannifin CorporationFiltration and Separation Division500 S. Glaspie StreetOxford, MI 48371phone 248 628 6400fax 248 628 1850www.cleancompressedair.comwww.parker.com/finitefilter
Flow Rates
Ordering InformationFor assistance call toll free at 1-800-521-4357, 8AM to 5PM EST
T-Series Description Optional Accessories** P/N Suffix N Manual drain only
A Auto-drain only
J High temperature option (use with “D” element type): includes fluorocarbon seals and manual drain
Finite T-SeriesSpecifications, Ordering, Flow Rates
Principal Specifications How to Order
* Depends on element and sealing options.
Product Line T-Series
Materials of Construction Body: Aluminum End Caps: Aluminum Seals: Buna-N or Fluorocarbon Manual Drain Fitting: Brass Auto Drain: Plastic
Min/Max Temp 35°F / 175°F or 450°F*
Max Pressure 250 PSIG
Inlet/Outlet Port Size 3/4” NPT or 1” NPT
Dimensions 5.50”w x 12.22”h
Clearance Height for Element Removal 9”
Shipping Weight 4.0 lbs.
** Optional Accessories specified by adding “N”, “A”, or “J” to the end of the Assembly part number, as shown above. See Ordering Information table at left for description of each accessory.
Part No. Example Assembly:T N 3 S - 6 C A
Part No. Example Replacement Element:6 C T 1 5 - 0 6 0
Build your own custom filter assembly using the guideline matrix below and specify your model number. Shaded boxes may not be required, depending on selections.
Element Type
Series Grade Accessory**(optional)
Element Type
SeriesGrade Size
CompleteAssemblies:
ThreadConnection
SizeBody
Replacement Elements:
T N S
0 6 0T 1 5
N=NPT 3=3/4”4=1”
Max. Oil Flow Rating Pressure Drop Element Max. % Carryover Micron @100 PSIG (PSID)@Rated Flow2 Grade Type Application Temp. Efficiency (PPM, w/w)1 Rating 3/4” port 1” port Dry dP Wet dP
4 C Coalescer of Liquid 175°F 99.995 0.003 0.01 61 76 1.25 3-4 6 Contaminants 99.97 0.008 0.01 80 100 1.0 2-3 8 98.5 0.2 0.5 109 136 0.5 1-1.5 10 95.0 0.85 1.0 133 166 0.5 0.5
4 D High Temperature 450°F 99.995 0.003 0.01 61 76 1.25 3-4 6 Coalescer 99.97 0.008 0.01 80 100 1.0 2-3 8 98.5 0.2 0.5 109 136 0.5 1-1.5 10 95.0 0.85 1.0 133 166 0.5 0.5
N/A WS Bulk Water Removal 175°F 99+ N/A 100.0 133 166 <0.25 <0.25 bulk water removal
3 P Particulate Removal 175°F N/A N/A 3.0 133 166 0.25 N/A
N/A A Oil Vapor (Odor) 99+ N/A 3.0 80 100 1 N/A Removal 175°F vapor removal1 Tested per ISO12500-1 at 40ppm inlet.2 Add dry and wet for total pressure drop.