Transcript of Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas...
![Page 1: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/1.jpg)
Finger PlethysmographFinger PlethysmographFor MeasuringFor Measuring
Blood ResistivityBlood ResistivityClient: John G. Webster, Ph.D
Advisor: Thomas Yen, Ph.D.
TeamTeamTim Balgemann- Team LeaderTim Balgemann- Team LeaderLucas Vitzthum- CommunicationsLucas Vitzthum- CommunicationsNick Harrison- BSACNick Harrison- BSACTyler Lark- BWIGTyler Lark- BWIG
![Page 2: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/2.jpg)
OutlineBackgroundProblem StatementTheory
Electrical Biological
ConceptsDesign Components
Circuit DesignMechanical
Future Work
![Page 3: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/3.jpg)
DiabetesBody’s inability to
manage glucose levelsPrevalence is on the rise
26.3 million in U.S.$116 billion excess medical
expenditures annually
No reliable non-invasive monitoring
Hypothesized that blood sugar levels may be correlated with blood resistivity
![Page 4: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/4.jpg)
Problem StatementDesign a finger
plethysmograph to measure blood resistivity
Goals:Build a mechanical
device to secure finger
Design a circuit that allows data acquisition of blood impedance
![Page 5: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/5.jpg)
Electrical TheoryFour electrode impedance plethysmography
2 electrodes pass current through finger2 electrodes measure voltageSignal processingCalculate impedance and resistivity from
voltage output
![Page 6: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/6.jpg)
Biological TheoryHigh blood flow
RBCs align, current meets little resistanceLow blood flow
RBCs misalign, greater resistanceImpedance (ΔZ) results from this
Change in volume of artery Saline solution cancels signal
High Flow Low Flow
![Page 7: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/7.jpg)
Design SpecificationsCircuit
SensitivityAdaptable measurement range (i.e. autoreset)Digital filtering and signal processing
Mechanical DeviceMotion artifactsMinimal electrical signature
![Page 8: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/8.jpg)
CircuitryMeasuring change
in blood resistivitySample and HoldFiltering Current amplitude
and frequencyData interpretation
Webster J. G., 1998
![Page 9: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/9.jpg)
Mechanical Design• Restrain Finger• Circulation• Conductive
Current Source
Voltmeter
![Page 10: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/10.jpg)
Restrain Designs
Air in
Side
Inflatable Cuff Mesh CageBar Cage
Top
![Page 11: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/11.jpg)
Future WorkBuild prototype
Optimize saline solutionCurrent amplitude and frequencyCircuit component values
TestingClinical Trials
![Page 12: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/12.jpg)
References Webster J. G., 1998. Measurement of flow and volume of
blood Medical Instrumentation: Application and Design, 3rd Edition ed J G Webster (New York: John Wiley & Sons).
Rosenthal, J. H., An inductive plethysmograph for ambulatory ventilation measurement.
American Diabetes Association: http://www.diabetes.org/diabetes-statistics.jsp
World Health Organization: http://www.who.int/dietphysicalactivity/publications/facts/diabetes/en/
![Page 13: Finger Plethysmograph For Measuring Blood Resistivity Client: John G. Webster, Ph.D Advisor: Thomas Yen, Ph.D. Team Tim Balgemann- Team Leader Lucas Vitzthum-](https://reader031.fdocuments.in/reader031/viewer/2022032517/56649cc05503460f949862a8/html5/thumbnails/13.jpg)
Questions??