FINA F24 - Pinnacle Architectural Lighting 2013 Website/Spec... · FINA F24 24” Direct and...

5
F24 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ HOUSING SHIELDING CRI, CCT & OUTPUT MOUNTING 1 F24 - 24” Fina Direct F24U - 24” Fina Uplight (7% Uplight) Shielding pg. 2 A - Flat Satine Lens AR - Regress Satine Lens AL - Lowered Satine Lens C - Flat Convex Lens CR - Regress Convex Lens CL - Lowered Convex Lens V - Flat Concave Lens VL -Lowered Concave Lens Shielding pg. 2 _27_ _ - 2700K _30_ _ - 3000K _35_ _ - 3500K _40_ _ - 4000K CL_ _ _ _ _ _ - Custom Lumens CW_ _ _ _ _ _ - Custom Watts Lumen Output pg. 2 AC3_ _ _ _ _ - 3 AC to JB or ST AH4_ _ _ _ _ - 4 AC w/hub to JB or ST PP_ _ _ _ - Pendant Pipe to JB or ST PS_ _ _ _ - Pendant Swivel to JB or ST S - Surface Mount WA - Wall Mount G - Grid Ceiling FL - Flanged NF - Non-Flanged SF - Spackle Flange Mounting pg. 3 _ _ _ _ _ _ FINISH FIXTURE OPTIONS CONTROLS W - White S - Metallic Silver BL - Textured Black BR - Bronze GR - Graphite CC - Custom Color Finish pg. 4 CP - Chicago Plenum AM - Antimicrobial Paint FW6 - 6’ Flex Whip FW12 - 12’ Flex Whip GLR - Fast Blow Fusing GMF - Slow Blow Fusing CC-C - Custom Color Canopy CC-P - Custom Color Pendant Fixture Options pg. 4 Pinnacle is able to accommodate different control solutions from different manufacturers. Consult Factory for more information. _ _ _ _ _ _ _ _ VOLTAGE DRIVER CIRCUITING BATTERY & EMERGENCY U - Universal (120 thru 277V) 1 - 120V 2 - 277V Voltage pg. 4 OL1 - Osram Optronics (10%, 0-10v) OL2 - Osram Optronics (1%, 0-10v) OL3 - Osram Optronics 347v (10%, 0-10v) LH1 - Lutron Hi-lume (1%, EcoSystem) L51 - Lutron 5-Series (5%, EcoSystem) ND - Non-Dimming Driver pg. 4 1 - Single Circuit E - Emergency (entire fixture) N - Night Light (entire fixture) Circuiting pg. 4 0 - None 1PB - Philips Bodine 10W Battery and Emergency pg. 4 1 Example: AC348JB. AC3 = 3 Aircraft Cables, 48 = 48” long cables, JB = connects to junction box. Standard AC cable lengths are 48” and 120”, field adjustable. Standard pendant lengths are 12”, 18”, or 48” 21-15/16” (557.2mm) 4-1/2” (114.3mm) 4-7/8” (123.8mm) Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. Project Name Date Type F24_LED_SPEC_JAN2019 Designed and Fabricated in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 Example Part #: F24-A-830HO-G-U-OL1-1-0-W F24_ - - - - - - - - - HOUSING SHIELDING CRI, CCT & OUTPUT MOUNTING VOLTAGE DRIVER CIRCUITING BATTERY & EMERGENCY FINISH FIXTURE OPTIONS FINA F24 24” Direct and Uplight Architectural Round Extruded aluminum housing is rolled and welded for seamless finish with 1/4” trim Aluminum top cover conceals all electrical components. Highly reflective die- formed white painted steel reflector FINA offered with a 5-year limited warranty. Covers LED, driver and fixture IC Rated (recessed only), UL and cUL Listed, approved for dry/damp location Maximum fixture weight is 20 lbs. Lift and shift lens allowing room-side maintenance for LED system Buy American Act compliant Key Features Example: 830HO is 8 = 80 CRI; 30 = 3000K; HO = High Output; Blank = Standard Output

Transcript of FINA F24 - Pinnacle Architectural Lighting 2013 Website/Spec... · FINA F24 24” Direct and...

Page 1: FINA F24 - Pinnacle Architectural Lighting 2013 Website/Spec... · FINA F24 24” Direct and Uplight Architectural Round • Extruded aluminum housing is rolled and welded for seamless

F24 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

HOUSING SHIELDING CRI, CCT & OUTPUT MOUNTING1

F24 - 24” Fina Direct F24U - 24” Fina Uplight (7% Uplight)Shielding pg. 2

A - Flat Satine LensAR - Regress Satine LensAL - Lowered Satine Lens C - Flat Convex LensCR - Regress Convex LensCL - Lowered Convex LensV - Flat Concave LensVL -Lowered Concave Lens Shielding pg. 2

_27_ _ - 2700K _30_ _ - 3000K _35_ _ - 3500K _40_ _ - 4000K CL_ _ _ _ _ _ - Custom Lumens CW_ _ _ _ _ _ - Custom Watts Lumen Output pg. 2

AC3_ _ _ _ _ - 3 AC to JB or STAH4_ _ _ _ _ - 4 AC w/hub to JB or STPP_ _ _ _ - Pendant Pipe to JB or STPS_ _ _ _ - Pendant Swivel to JB or STS - Surface MountWA - Wall MountG - Grid CeilingFL - Flanged NF - Non-FlangedSF - Spackle FlangeMounting pg. 3

_ _ _ _ _ _

FINISH FIXTURE OPTIONS CONTROLS

W - WhiteS - Metallic SilverBL - Textured Black BR - BronzeGR - GraphiteCC - Custom ColorFinish pg. 4

CP - Chicago PlenumAM - Antimicrobial Paint FW6 - 6’ Flex WhipFW12 - 12’ Flex WhipGLR - Fast Blow FusingGMF - Slow Blow FusingCC-C - Custom Color CanopyCC-P - Custom Color PendantFixture Options pg. 4

Pinnacle is able to accommodate different control solutions from different manufacturers. Consult Factory for more information.

_ _ _ _ _ _ _ _

VOLTAGE DRIVER CIRCUITING BATTERY & EMERGENCY

U - Universal (120 thru 277V)1 - 120V 2 - 277VVoltage pg. 4

OL1 - Osram Optronics (10%, 0-10v)OL2 - Osram Optronics (1%, 0-10v)OL3 - Osram Optronics 347v (10%, 0-10v)LH1 - Lutron Hi-lume (1%, EcoSystem)L51 - Lutron 5-Series (5%, EcoSystem)ND - Non-DimmingDriver pg. 4

1 - Single Circuit E - Emergency (entire fixture)N - Night Light (entire fixture)Circuiting pg. 4

0 - None1PB - Philips Bodine 10WBattery and Emergency pg. 4

1Example: AC348JB. AC3 = 3 Aircraft Cables, 48 = 48” long cables, JB = connects to junction box. Standard AC cable lengths are 48” and 120”, field adjustable. Standard pendant lengths are 12”, 18”, or 48”

FINA 24 (F24)

21-15/16” (557.2mm)

4-1/2”(114.3mm)

4-7/8”(123.8mm)

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

Project Name

Date Type

F24_LED_SPEC_JAN2019Designed and Fabricated in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570

Example Part #: F24-A-830HO-G-U-OL1-1-0-W

F24_ - - - - - - - - -HOUSING SHIELDING CRI, CCT &

OUTPUTMOUNTING VOLTAGE DRIVER CIRCUITING BATTERY &

EMERGENCYFINISH FIXTURE

OPTIONS

FINA F2424” Direct and Uplight Architectural Round

• Extruded aluminum housing is rolled and welded for seamless finish with 1/4” trim• Aluminum top cover conceals all electrical components. Highly reflective die-

formed white painted steel reflector• FINA offered with a 5-year limited warranty. Covers LED, driver and fixture• IC Rated (recessed only), UL and cUL Listed, approved for dry/damp location• Maximum fixture weight is 20 lbs.• Lift and shift lens allowing room-side maintenance for LED system • Buy American Act compliant

Key Features

Example: 830HO is 8 = 80 CRI; 30 = 3000K; HO = High Output; Blank = Standard Output

Page 2: FINA F24 - Pinnacle Architectural Lighting 2013 Website/Spec... · FINA F24 24” Direct and Uplight Architectural Round • Extruded aluminum housing is rolled and welded for seamless

• White virgin acrylic lens with matte finish, removable for LED access• Select from flat, concave, or convex formed satine lens

• Lens available in 3 positions - Flush - Regressed - Lowered

A C VFlat Lens Convex Lens Concave Lens

AR CR VLRegress Satine Lens Regress Convex Lens Lowered Concave Lens

AL CLLowered Satine Lens Lowered Convex Lens

FINA F24

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

F24_LED_SPEC_JAN2019

• Specify either 80 or 90 CRI • Longer lead-time may apply for 90 CRI. Consult factory.

• 80 CRI = R9≥19 and 90 CRI = R9≥61

Designed and Fabricated in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 F: 303-322-5568

Architectural Round

Output

Shielding

HousingF24 - DIRECT F24U - UPLIGHT

Standard Fina is 100% direct Fina with uplight has slots in top of housing to allow for about 7% of indirect light to create glow above fixture

pg. 2

Custom Output- Lumens OR WattageCL_ _ _ _ _ Specify CRI, CCT and desired lumens (i.e. CL8354500) Specify lumens between standard offering listed below. Lumens are specified per color temp

CW_ _ _ _ _ Specify CRI, CCT and desired wattage (i.e. CW94045) Specify watts between standard offering listed below

80 CRIColor Output Housing

DIRECT UPLIGHTWatts Lumens LPW Watts Lumens LPW

830 3000K Standard 39.4 3187 80.9 36.1 3166 87.7830HO 3000K High 68 5066 74.5 62 5033 81.2835 3500K Standard 39.4 3277 83.2 36.1 3255 90.2835HO 3500K High 68 5210 76.6 62 5175 83.5840 4000K Standard 39.4 3340 84.8 36.1 3318 91.9840HO 4000K High 68 5310 78.1 62 5275 85.1

90 CRI927 2700K Standard 39.4 2519 63.9 36.1 2502 69.3927HO 2700K High 68 4004 58.9 62 3978 64.2930 3000K Standard 39.4 2936 74.5 36.1 2916 80.8930HO 3000K High 68 4666 68.6 62 4636 74.8935 3500K Standard 39.4 2947 74.8 36.1 2927 81.1935HO 3500K High 68 4684 68.9 62 4653 75.0940 4000K Standard 39.4 2980 75.6 36.1 2960 82.0940HO 4000K High 68 4737 69.7 62 4706 75.9

Page 3: FINA F24 - Pinnacle Architectural Lighting 2013 Website/Spec... · FINA F24 24” Direct and Uplight Architectural Round • Extruded aluminum housing is rolled and welded for seamless

FINA F24

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

F24_LED_SPEC_JAN2019Designed and Fabricated in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 F: 303-322-5568

Architectural Round

Mounting - Suspended - Recessed• Aircraft cables and pendants mount directly to a standard junction

box or structure• Canopies, pendant, and power cords are white. Specify canopy and pendant

color in Fixture Options• AC canopies can be installed below the ceiling plane or semi-recessed into

the ceiling for a flush mount installation, no specification required (see below)

• Must specify overall pendant length of 12”, 18” or 24”• Must specify cable length, either 48” or 120” standard, field adjustable• Designed to install into acoustical grid and inaccessible ceilings• Tie off fixture to structure with retention wires• Maximum fixture weight is 20 lbs

AC3___JB AH4___JB PP__JB S3 AC cables to fixture to J-Box 4 AC cables with hub to fixture to

J-BoxPendant Pipe to J-Box Surface Mount CeilingPS__JBPendant Swivel to J-Box

AC3___ST AH4___ST PP__ST WA3 AC cables to fixture to Structure 4 AC cables with hub to fixture to

StructurePendant Pipe to Structure Surface Mount WallPS__STPendant Swivel to Structure

GGrid Ceiling with 3/4” (19.1mm) Trim15/16” T-Bar 9/16” T-Bar Screw Slot T-Bar Recessed box allows for 1/2” of

adjustability to accommodate a variety of grid ceilings

FL NF SFStandard 3/4” (19.1mm) FlangeExposed Flange

Non-Flange with 1/4” (6.4mm) TrimMetal Pan or Millwork

Spackle FlangeDrywall, Flangeless

• The canopy can be installed either below the ceiling plane or semi-recessed into the ceiling for a flush mount installation

• Standard kit can be installed either way• Flush canopy installation is not available for fixtures installed below a grid rail

Canopies

pg. 3

Page 4: FINA F24 - Pinnacle Architectural Lighting 2013 Website/Spec... · FINA F24 24” Direct and Uplight Architectural Round • Extruded aluminum housing is rolled and welded for seamless

FINA F24

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

F24_LED_SPEC_JAN2019

0 No Battery1PB Philips Bodine 10w

1 Single CircuitE Emergency Circuit onlyN Night Light Circuit only

Battery & Emergency

For Approximate Battery Lumen Output• Multiply battery wattage X fixture LPW shown on Lumen Table• 10 (watts) x 92.3 (LPW) = 923 battery lumen output

Battery & Emergency Ordering Examples• Single circuit, 10w integral battery Ordering Code: 1-1PB • Emergency circuit only, 10w integral battery Ordering Code: E-1PB

• Select battery or emergency options if required• Battery duration is 90 minutes

• Test button is integral to fixture• For more Battery options, see Pinnacle Resource Guide

Circuiting• Select fixture circuiting from options below• Some FINA configurations will not accommodate all circuiting options; consult with factory

U Universal1 120 volt2 277 volt

Voltage

Driver

• Some FINA configurations will not accommodate all voltage options; consult with factory

Finish• Powder-coat white painted finish on exposed trim

W WhiteS Metallic SilverBL Textured SilverBR BronzeGR GraphiteCC Custom Color

Designed and Fabricated in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 F: 303-322-5568

Architectural Round

OL1 Osram Optotronic 10%, 0-10vOL2 Osram Optotronic 1%, 0-10vOL3 Osram Optotronic 347v 10%, 0-10v, requires 347vLH1 Lutron Hi-lume Soft-on, Fade-to-black 1%, EcoSystem, LDE1L51 Lutron 5-Series 5%, EcoSystem LDE5ND Non Dimming

pg. 4

• Standard Driver Option = OL1 • Driver Lifetime: 50,000 hours at 25°C ambient operating conditions• For more Driver options, see Pinnacle Resource Guide

• Some FINA configurations will not accommodate all driver options; consult with factory

Fixture Options• Additional options to enhance the fixture and finish of the product

CP Chicago PlenumAM Antimicrobial PaintFW6 Flex Whip 6’FW12 Flex Whip 12’GLR Internal Fast Blow FuseGMF Internal Slow Blow FuseCC-C Custom Color CanopyCC-P Custom Color Pendant

Page 5: FINA F24 - Pinnacle Architectural Lighting 2013 Website/Spec... · FINA F24 24” Direct and Uplight Architectural Round • Extruded aluminum housing is rolled and welded for seamless

FINA F24

Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.

F24_LED_SPEC_JAN2019

Approvals & Certifications

Controls• Pinnacle is able to accommodate different control solutions from different manufacturers. Consult Factory for more information.

Designed and Fabricated in Denver, CO • USA | pinnacle-ltg.com | O: 303-322-5570 F: 303-322-5568

Architectural Round

pg. 5

PhotometricsFina Direct Fina Uplight

Satine LensTest # ITL81253Catalog # F24U-A-840Lumens 3320 lmWatts 36.1 WEfficacy 92 LPW

1169

877

586

292

Satine LensTest # ITL80342Catalog # F24A-840Lumens 3340 lmWatts 39.4 WEfficacy 85 LPW

1060

795

530

265

Candela Distribution Luminance Data (cd/sq.m)Vert Angle

Horizontal Angle Angle In Degrees

Average 0-Deg

Average 45-Deg

Average 90-Deg

0 22.5 45 67.5 90 45 4309 4305 43020 1060 1060 1060 1060 1060 55 4163 4154 41455 1057 1057 1057 1057 1057 65 3892 3892 388710 1044 1044 1044 1045 1044 75 3410 3438 344815 1021 1021 1022 1022 1022 85 2729 2782 286220 990 989 990 990 99025 950 948 949 949 94930 901 901 901 900 90035 846 845 845 844 84440 784 784 783 782 78345 715 715 715 714 71450 641 641 641 641 64155 562 562 561 561 56060 478 478 478 478 47765 390 390 390 390 38970 301 301 302 301 30075 211 213 213 213 21480 130 130 131 131 13385 60 61 61 62 6390 6 6 6 6 795 4 4 2 2 2100 6 4 4 4 5105 11 8 7 8 9110 16 13 12 13 15115 23 20 19 20 21120 30 27 27 27 29125 41 34 39 34 40130 53 44 47 45 53135 62 53 49 53 62140 67 58 51 58 67145 70 63 56 63 70150 77 72 68 71 76155 88 85 84 85 87160 102 99 99 99 102165 114 113 113 113 114170 124 123 123 123 124175 130 130 130 130 130180 133 133 133 133 133

Candela Distribution Luminance Data (cd/sq.m)Vert Angle

Horizontal Angle Angle In Degrees

Average 0-Deg

Average 45-Deg

Average 90-Deg

0 22.5 45 67.5 90 45 4818 4818 48120 1169 1169 1169 1169 1169 55 4664 4641 46415 1162 1162 1162 1161 1161 65 4376 4365 434410 1145 1145 1145 1145 1144 75 3816 3833 383315 1116 1117 1117 1117 1117 85 2987 3039 309020 1080 1080 1080 1080 107925 1034 1034 1035 1033 103430 980 981 981 980 98035 919 920 919 918 91940 850 851 850 850 85045 776 775 776 775 77550 696 693 694 693 69355 609 606 606 606 60660 516 514 516 514 51465 421 420 420 419 41870 323 322 323 322 32275 225 225 226 226 22680 135 136 137 137 13785 59 59 60 60 6190 0 0 0 0 0

Construction: Extruded aluminum housing is rolled and welded for seamless finish with minimal trim detail. Aluminum top cover conceals all electrical components. Highly reflective die-formed white painted steel reflector. Wiring access on both sides and top of housing.

Shielding: Single piece lift and shift diffuse lens creating a fully luminous housing. Available with standard satine lens.

Mounting: Designed to install into acoustical grid and inaccessible ceilings. Recessed, aircraft cable, pendant and surface mount available. For recessed, specify G for acous-tical grid ceiling. Specify FL, NF, or SF for inaccessible ceilings and specify S or WA for surface or wall mount. Specify AC or PP for suspended mounting. Tie off fixture to structure with retention wires. Maximum fixture weight is 20 lbs.

LED: 25ºC test environment. Lumen output/wattage has a margin of +/- 5%. All lumi-naire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. Lifetime calculated using IES TM-21. Minimum lifetime greater than 60,000 hours. MacAdam 3-Step Ellipses. Not all products are Lighting Facts listed. For all available IES files, please visit our website at pinnacle-ltg.com.

CRI, CCT & Output: Two lumen packages available. Standard and High (HO). Custom outputs are available. Specify custom lumens or watts between standard offering listed on CRI, CCT & Output page. 80 CRI is available for 3000K, 3500K, and 4000K. 90 CRI is available for 2700K, 3000K, 3500K, and 4000K. 80 CRI = R9≥19 and 90 CRI = R9≥61.

Voltage: Universal (U), 120 volt (1), 277 volt (2) options available. Some FINA configu-rations will not accommodate all voltage options; consult with factory.

Driver: Standard Driver Option is Osram 0-10V, 10% = OL1. Electronic driver, Power factor is >0.9 with a THD <20%. Driver Lifetime: 50,000 hours at 25°C ambient oper-ating conditions. For more driver options, see Pinnacle Resource Guide. Some FINA configurations will not accommodate all driver options.

Circuiting: Select from single circuit (1), Emergency circuit (E) or Night Light circuit (N). Some FINA configurations will not accommodate all circuiting options; consult with factory.

Battery & Emergency: Select battery or emergency options if required. If battery or emergency option is not required, enter 0. Battery duration is 90 minutes as standard. Test button is integral to fixture. For more Battery options, see Pinnacle Resource Guide.

Finish: Standard powder-coat textured white, metallic silver, textured black, graphite, or bronze painted finish, consult factory for chip of standard paint finishes. Contact factory for additional custom color and finish options.

Controls: Consult factory.

Labels: UL and cUL Listed. Standard and HO lumen packages are IC Rated, approved for dry/damp location unless otherwise noted.

Fixture Weight: 20 lbs maximum

Buy American Act Compliant

Warranty: FINA LED offered with a 5-year limited warranty. Covers LED, driver and fixture.