Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the...

17
Filtration MPSG-CSG Series MST-CT Series MSH-CH Series STR Series TMS Series Suction Strainers Spin-On S e c t i o n 1

Transcript of Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the...

Page 1: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Filtration

MPSG-CSG Series

MST-CT Series

MSH-CH Series

STR Series

TMS Series

Suction Strainers

Spin-On

Se

ct

io

n

1

Page 2: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Description

Suction Strainers - STR SeriesSuction Strainers - STR Series

Technical Data

STR filter elements are suitable for use on the

suction line, submerged in the reservoir. They are available in 16 sizes for nominal

flows up to 158 GPM with 150 SUS (oil), with

or without bypass.

Materials: Connection: Nylon. Bypass valve: Nylon.

Filter Element Materials: Series M: Square wire mesh

M60 - Stainless Steel.

M90 - Nickel plated polyester.

M250 - Zinc plated steel.

Support Tube, Upper and Base Plates: Galvanized steel

Dirt Holding Capacity: as per ISO 4572

(filtration degree is defined in microns

By the maximum diameter of a sphere fitting in the mesh of the grid).

Compatibility With Fluids: As per ISO 2943; suitable for mineral oils (types HH-HL-HM-HR-HV-

HG as per ISO 6743/4).

Synthetic fluids (types HS-HFDR or HFDS-HFDU as per ISO 6743/4)

For water-based emulsions (types HFAE-HFAS as per ISO 6743/4)

Bypass Valve Calibration: Bypass valve, differential opening pressure:

Series "B": 4.5 PSID ± 10%,

Series "S": without

Operating Temperature: from - 25ºC to + 100ºC

This product is suited for temperatures below -25ºC where proper

start-up procedure is used. Please contact your MP Filtri representative.

1-1

M60

M90

M250

45

45

45

111

111

111

310

310

310

561

561

561

73

73

73

162

162

162

550

550

550

645

645

645

287

287

287

Type STRType STR 050-1-2050-1-2 070-3-4070-3-4 140-1-2140-1-2 140-5140-5070-1-2070-1-2 100-1-5100-1-5 140-3-4140-3-4 140-6140-6100-2-3-4100-2-3-4Filtering Area

2Elements: (in )

Page 3: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Installation Data STR Series

3

4

4

12

12

22

35

35

55

80

55

55

80

80

120

155

155

050-1 G2

050-2 G2

070-1 G2

070-2 G2

070-3 G2

070-4 G2

100-1 G2

100-2 G2

100-3 G2

100-4 G2

100-5 G2

140-1 G2

140-2 G2

140-3 G2

140-4 G2

140-5 G2

140-6 G2

3/8" NPT

1/2" NPT

1/2" NPT

3/4" NPT

3/4" NPT

1" NPT

1-1/4" NPT

1-1/4" NPT

1-1/2" NPT

2" NPT

1-1/2" NPT

1-1/2" NPT

2" NPT

2" NPT

2-1/2" NPT

3" NPT

3" NPT

2.04

2.04

2.75

2.75

2.75

2.75

3.90

3.90

3.90

3.90

3.90

5.12

5.12

5.12

5.12

5.12

5.12

3.07

3.07

3.74

3.74

5.51

5.51

5.31

8.86

8.86

8.86

5.31

6.30

6.30

10.30

10.63

10.63

13.00

.39

.39

.39

.39

.39

.39

.59

.59

.59

.59

.59

.59

.59

.59

.78

.78

.78

1.18

1.18

1.65

1.65

1.65

1.65

2.71

2.71

2.71

2.71

2.71

2.75

2.75

2.75

3.97

3.97

3.97

.35

.35

.49

.49

.66

.66

1.03

1.50

1.50

1.50

1.85

1.85

2.75

1.03

2.75

2.75

2.86

Nominal

Flow (GPM)

Nominal

Flow (GPM)Type STRType STR AA BB H1H1 H2H2 CHCH Wt. lbWt. lb

Pressure drop is localized in the

connection and does not depend on

filtration level chosen (M60-M90-M250)

MP Filtri recommends the pressure drop

does not exceed 0.4 psi.

Element Pressure Drop

The following curves were obtained using

a mineral oil with a kinematic viscosity of

150 SUS.

1-2

Page 4: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Ordering Information STR Series

STRSTR 050-1050-1 SS G2G2 M90M90

STR M60

M90

M250

S

B

G1

G2

050-1

050-2

070-1

070-2

070-3

070-4

100-1

100-2

100-3

100-4

100-5

140-1

140-2

140-3

140-4

140-5

140-6

Complete Filter Fine 240 mesh

Standard 164 mesh

Coarse 60 mesh

Without

With

Optional Metricthreads on request

NPT thread(Standard)

3/8"

1/2"

1/2"

3/4"

3/4"

1"

1-1/4"

1-1/4"

1-1/2"

2"

1-1/2"

1-1/2"

2"

2"

2-1/2"

3"

3"

SERIES MICRON RATING

BYPASS VALVE

CONNECTIONS

SIZES

1-3

Page 5: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Tank Mounted Strainers - TMS SeriesTank Mounted Strainers - TMS Series

No by-pass

Perforated steel support tubes

Temperatures to +250ºF (+120ºC)

100 Mesh stainless steel plated elements

5 PSI by-pass special order.

Designed for ease of servicing. Access to tank

interior is not necessary.

Mount through sidewall or through tank top

and into a standpipe

Specifications

TMS-3

TMS-5

TMS-10

TMS-15

TMS-25

TMS-50

TMS-100

Part #Part #

3

5

10

15

25

50

100

3/8" NPT

1/2" NPT

3/4" NPT

1" NPT

1 1/4" NPT

2" NPT

3" NPT

4.00

5.34

8.17

8.20

9.04

9.70

11.30

28.70

35.00

64.00

86.00

125.00

260.00

315.00

0.97

1.06

1.10

1.30

1.30

1.70

1.80

0.87

1.03

1.36

1.62

2.12

3.00

4.00

GPMRatingGPM

RatingCC Screen Area

2(in )Screen Area

(in )2DD EEBBAA

3/4" NPT

1" NPT

1 1/4" NPT

1 1/2" NPT

2" NPT

3" NPT

4" NPT

Ordering Information

1-4

Page 6: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Spin-On - MPS/MPSG SeriesSpin-On - MPS/MPSG Series

Maximum Working Pressure: 175 PSI

75 PSI max. if non-bypass.

Temperature: -25ºC to +107ºC

Materials: Head: aluminum

Seals: Series "A" nitrile (Buna-N)

Series "V" viton

Bypass valves: nylon glass filled poppet.

Indicators: brass, steel

Filter Element Materials: Series "A": Inorganic Microfibre with acrylic support.

Series "P": Resin-impregnated paper

Series "M": Square wire mesh (filtration degree is defined in microns

by the maximum diameter of a sphere fitting in the mesh grid)

Support Tube, Upper and Base Plates: Galvanized steel

Support Frames: Galvanized steel with an epoxy coating.

Dirt Holding Capacity: As per ISO 4572: multi-pass test

Water Holding Capacity CSGW O5O - 240 ml,

for CSGW elements:

Operating

CSGW-100 - 468 ml, CSGW-150 - 600 ml.

The MPS/MPSG Filter series is suitable for use

on suction and return lines.

With Spin-On canisters MPS/MPSG filters are

easy to maintain.

Fits both European and North American series

elements.

Description

Technical Data

1-5

Water removal is an option with CSGW series

elements.

Page 7: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

1-6Fluid Compatibility

Filter Heads: • Mineral oils (types HH-HL-HM-HR-HG-as per ISO 6743/4)

• Water-based emulsions (types HFFAE-HFAS as per ISO 6743/4)

• Synthetic fluids (types HS-HFDR-HFDU-HFDS as per ISO 6743/4)

• Water glycol (type HFC as per ISO 6743/4)

ask for anodized version

Seals: Series "A":

• Nitrile (Buna-N) compatible with all mineral oils (types

HH-HL-HM-HR-HV-HG-as per ISO 6743/4).

• Water-based emulsions (type HFAE-HFAS as per ISO 6743/4).

• Water glycol (type HFC as per ISO 6743/4)

Series "V":

• Viton, compatible with synthetic fluids (types HS-HFDR-HFDS-

HFDU as per ISO 6743/4)

Filter Elements: Suitable for mineral oils as per ISO 2943 (types HH-HM-HR-HV-

HG as per ISO 6743/4).

Viton seals for use with water glycol are available.

For other fluids please contact customer service.

Element Collapse: 58 PSID

Bypass Calibration: Differential opening pressure:

Series "R" = 25 PSID

Series "T" = 15 PSID

Series "S" = 4.5 PSID

A03

A06

A10

A25

P10

P25

FilterElement

FilterElement

-

-

3

13

10

25

3

6

8

23

>30

>30

>10.000

>10.000

>10.000

35

4.5

1.3

2

3

6

19

>30

>30

20

8

1.5

-

1

1

100

100

100

100

100

100

>10.000

>2.000

150

1.5

2

1

B>2(50%)B>2

(50%)B>20(95%)B>20(95%)

B>75(98.7%)

B>75(98.7%)

Dimensions for ß (µm) valuesDimensions for ß (µm) values

ß2ß2 ß10ß10 ß20ß20

Filtration RatiosFiltration Ratios sPsP

(PSI)(PSI)

N.B. Other materials giving different filtration degrees are available on request

Page 8: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Types of Indicators for Visual Indicator:

Electrical IndicatorFor Suction :

Electrical Indicator

MPS/MPSG series "0" (MPS 050-070-100...)

Suction filter: (MPS series only): VS vacuum switch scale 0-30 in HgReturn filter: VR colour coded pressure gauge scale 0-87 psi"EO" vacuum switch with change over contact switching at 3 psi ± 10%

(MPS series only) Max voltage: 250V 50/60 Hz. Max current: 5A resistive, 2A inductiveProtection Degree IP65ER pressure switch - N.O. contacts; EC pressure switch - N.C. contacts

For Return: Switching at 18 psi ± 10%Max voltage: 48V 50/60 Hz. Max current: 0,5A resistive, 0,2A inductive

MPS/MPSG series "1" Are fitted with differential style indicators(MPS 051-071-101...) Visual Indicator: 1V-Z1 Series for filter with bypass set to 25 psi switching at 18 psi ± 10%

V6-Z6 Series for filter without bypass switching at 30 psi ± 10% Electrical Indicator: N1 Series for filter with bypass set to 25 psi switching at 18 psi ± 10%

N6 Series for filter without bypass switching at 30 psi ± 10%Visual-Electrical Indicator: 1E Series for filter with bypass set to 25 psi switching at 18 psi ± 10%

E6 Series for filter without bypass switching at 30 psi ± 10%

1-7 Indicators MPS/MPSG Series

Vca 125

Vca 250

Vcc 30

Vcc 125

Vcc 250

5

5

5

0.5

0.25

2

2

3

0.03

0.03

Supply Voltage (V)Supply Voltage (V) Resistive Load (A)Resistive Load (A) Inductive Load (A)Inductive Load (A)Pressure DifferentialIndicator Option E-N Series:

Page 9: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

s(

)p

PS

Is

SERIES R

SERIES T

SERIES S

60

45

30

15

0.00.0 5 10 15 20 25 30

Flow Rate (GPM)

MPSG 050-070

General: The curves shown were obtained experimentally in accordance with

standard ISO 3968, using new filter elements.

All curves were obtained using a mineral oil with a density of 0.86

and a kinematic viscosity of 150 SUS.

When choosing an MPSG filter, the following guidelines should be used

1) The maximum P of the filter assembly should fall between 6 &

9 PSI when the system is at maximum flow and operating at

minimum temperature.

2) At normal operating conditions the P of the filter assembly

should fall between 3 and 6 PSI.

s

s

s

ss

()

p P

SI

s

12.0

9.0

6.0

3.0

0.0

Flow Rate (GPM)

0.0 13.5 27.0 40.5 54.0 67.5 81.0 94.5 108 121.5 135.0

s(

)p

PS

Is

SERIES R

SERIES T

SERIES S

60

45

30

15

0.00.0 6.5 13.0 19.5 26.0 32.5 39.0

Flow Rate (GPM)

MPSG 100-150, 200-250, 300-350

MP

SG

05

0-0

70

MPSG

100-1

50

MPSG 200-250

MPSG 300-350

Pressure Drops - MPS/MPSG Filters

Housing Pressure Drop

MPS/MPSG Bypass Valve Pressure Drop

1-8

Page 10: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

s(

)p

PS

Is

P10

P25

M60

M90

0.0 5 10 15 20 25 30Flow Rate (GPM)

CS-CT-CSG 050- ...P/Ms

()

p P

SI

s

A03

A06

A10

A25

12.0

9.0

6.0

3.0

0.00.0 5 10 15 20 25 30

Flow Rate (GPM)

CS-CT-CSG 050-A...

s(

)p

PS

Is

P10

P25

M60

M90

6.0

4.5

3.0

1.5

0.00.0 5 10 15 20 25 30

Flow Rate (GPM)

CS-CT-CSG 070-P/M...

s(

)p

PS

Is

A10

A03

A06

A25

12.0

9.0

6.0

3.0

0.00.0 5 10 15 20 25 30

Flow Rate (GPM)

CS-CT-CSG 070-A...

s(

)p

PS

Is

A10

A03

A06

A25

30.0

22.5

13.0

7.5

0.00.0 15 30 45 60 75 90

Flow Rate (GPM)

CS-CT-CSG 100-A...

s(

)p

PS

Is

M60

P10

P25

M90

6.0

4.5

3.0

1.5

0.00.0 15 30 45 60 75 90

Flow Rate (GPM)

CS-CT-CSG 100-P/M...

Note: Values expressed in the charts are based

on mineral oils with a density of 0.86 and a

kinematic viscosity of 150 SUS. P is directly

proportional to change in viscosity for laminar

ss

s(

)p

PS

Is

A10

A03

A06

A25

18.0

13.5

9.0

4.5

0.00.0 15 30 45 60 75 90

Flow Rate (GPM)

CS-CT-CSG 150-A...

s(

)p

PS

Is

M60

P10

P25

M90

6.0

4.5

3.0

1.5

0.00.0 15 30 45 60 75 90

Flow Rate (GPM)

CS-CT-CSG 150-P/M...

flows and directly proportional to density for

turbulent flows. For specific values on your

application, please contact your MP Filtri

representative.

Filter Elements - Pressure Drops MPS/MPSG1-9

6.0

4.5

3.0

1.5

0.0

Page 11: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Ind

icator p

ort fo

r suctio

n lin

e filter

Indicator port for return line filter

H2

H1

MPS/MPSG 050-051, 070-071MPS/MPSG 050-051, 070-071

Technical Data

CS-CSG 050

CS-CSG 070

Type Type

318

520

159

197

434

706

141

199

A03/A25A03/A25 M60M60P10/P25P10/P25 M90M90

2Filtering Area (in ):

G0

U2

G3

G4

TypeType

TypeType

7.08

9.76

1/2” NPT

3/4" NPT

SAE 12-1 1/16"-12 UN

1” NPT

7.87

10.55

1/8" NPT

1/8" NPT

1/8" NPT

1/8" NPT

2.2

2.9

1/4" UNC

1/4" UNC

1/4" UNC

1/4" UNC

H1H1

AA

H2H2

BB

Weights*LbsWeights*Lbs

CC

Dimensions (inches):

Thread Connection:

CS-CSG 050

CS-CSG 070

The above filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter (housing and filter element) pressure drop of 30% of the filter condition indicator (6 psi) for line and return filter and 1.15 psi for suction filter.

Please refer to individual pressure drop curves to obtain filter assembly pressure drop information

A03

A06

A10

A25

P10

M60-M90

2.3

2.9

3.7

4.7

4.2

6.3

10.5

11.6

12.7

15.3

14.5

-

see

table

below

Filter AssemblyMPS 050-MPS 051

Filter AssemblyMPS 050-MPS 051

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

A03

A06

A10

A25

P10

M60-M90

2.9

3.4

4.0

5.3

4.7

6.9

12.0

13.0

14.0

16.7

15.3

-

see

table

below

Filter AssemblyMPS 070-MPS 071

Filter AssemblyMPS 070-MPS 071

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

* Flow rates with 150 SUS fluid viscosity

MPS 051-071 SERIES

H2

H1

.75" Element Removal

Indicator port

MPS 050-070 SERIES

*Weight complete with element.

1-10

Page 12: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

A

MPS/MPSG 100-101, 150-151MPS/MPSG 100-101, 150-1511-11

Technical Data

2Filtering Area (in ):

Dimensions (inches):

Thread Connection:

G2

G3

TypeType

TypeType

9.48

11.25

1-1/4" NPT

SAE20 1-5/8"-12 UN

10.47

12.24

1/8" NPT

1/8" NPT

4.8

5.0

5/16" UNC

5/16" UNC

H1H1

AA

H2H2

BB

Weights*LbsWeights*Lbs

CC

CS-CSG 100

CS-CSG 150

CS-CSG 100

CS-CSG 150

Type Type

620

930

309

410

874

1172

266

357

A03/A25A03/A25 M60M60P10/P25P10/P25 M90M90

* Weight complete with element.

The above filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter (housing and filter element) pressure drop of 30% of the filter condition indicator (6 psi) for line and return filter and 1.15 psi for suction filter.

Please refer to individual pressure drop curves to obtain filter assembly pressure drop information

A03

A06

A10

A25

P10

M60-M90

4.2

5.0

6.6

10.5

9.2

17.0

19.8

22.5

29.0

37.0

34.0

-

Filter AssemblyMPS 100-MPS 101

Filter AssemblyMPS 100-MPS 101

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

A03

A06

A10

A25

P10

M60-M90

4.7

5.8

7.9

11.9

10.5

18.0

22.5

26.4

30.4

42.3

37

-

Filter AssemblyMPS 150-MPS 151

Filter AssemblyMPS 150-MPS 151

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

* Flow rates with 150 SUS fluid viscosity

1 1/4"

1 1/4"

MPS 101-151 SERIES

H2

H1

MPS 100-150 SERIES

H2

H1

1/8" NPT( )SUCTION

1/8" NPT(RETURN)

1.207 1.207

.750

5.501.500

6X 5/16-18UNC 2B

.56 THREADDEPTH

Page 13: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

MPS/MPSG 200-250MPS/MPSG 200-250

G2

G3

TypeType

TypeType

8.5

10.27

1-1/2" NPT

SAE20 1-7/8"-12 UN

9.48

11.26

1/8" NPT

1/8" NPT

8.8

9.2

3/8" UNC

3/8" UNC

H1H1

AA

H2H2

BB

Weights*LbsWeights*Lbs

CC

* Weight complete with element.

Technical Data

Thread c

on

nectio

n f

or in

dic

ator(return

)

Dimensions (inches):

Thread Connection:

2Filtering Area (in )

Per element:

Note: 2 elements required

per filterCS-CSG 100

CS-CSG 150

CS-CSG 100

CS-CSG 150

Type Type

620

930

309

410

874

1172

266

357

A03/A25A03/A25 M60M60P10/P25P10/P25 M90M90

A03

A06

A10

A25

P10

M90

7.9

11.9

17.0

29.0

26.4

31.7

34.3

45.0

58.0

76.7

71.4

-

1 1/2"

Filter AssemblyMPS 200

Filter AssemblyMPS 200

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

A03

A06

A10

A25

P10

M90

13.2

15.8

21.0

33.0

31.2

34.3

47.6

55.5

66.0

82.0

74.0

-

1 1/2"

Filter AssemblyMPS 250

Filter AssemblyMPS 250

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

* Flow rates with 150 SUS fluid viscosityThe above filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter (housing and filter element) pressure drop of 30% of the filter condition indicator (6 psi) for line and return filter and 1.15 psi for suction filter.

Please refer to individual pressure drop curves to obtain filter assembly pressure drop information

1-12

Page 14: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

MPS/MPSG 300-301, 350-351MPS/MPSG 300-301, 350-351

F1

F2

TypeType

1-1/2" SAE 3000 PSI/M

1-1/2" SAE 3000 PSI/UNC

1/8" BSP

1/8" NPT

M10

3/8" UNC

M12

1/2" UNC

2.75

2.75

1.406

1.406

AA BB CC FFDD EEFlange

Connections

1-13

Technical Data

Thread

connection

for indicator

(suction)

5.1

2

TypeType

10.45

12.20

11.42

13.20

11.88

12.32

H1H1 H2H2 Weights*LbsWeights*LbsDimensions (inches):

* Weight complete with element.

G2

G3

TypeType

1-1/2" NPT

SAE20 1-7/8"-12 UN

1/8" NPT

1/8" NPT

3/8" UNC

3/8" UNC

AA BB CCThread Connection

2Filtering Area (in )

Per element:

Note: 2 elements required

per filterCS-CSG 100

CS-CSG 150

CS-CSG 100

CS-CSG 150

Type Type

620

930

309

410

874

1172

266

357

A03/A25A03/A25 M60M60P10/P25P10/P25 M90M90

The above filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter (housing and filter element) pressure drop of 30% of the filter condition indicator (6 psi) for line and return filter and 1.15 psi for suction filter.

Please refer to individual pressure drop curves to obtain filter assembly pressure drop information

A03

A06

A10

A25

P10

M90

7.9

11.9

17.0

29.0

26.4

31.7

34.3

45.0

58.2

76.7

71.4

-

Filter AssemblyMPS 300MPS 301

Filter AssemblyMPS 300MPS 301

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

A03

A06

A10

A25

P10

M90

13.2

15.8

21.0

33.0

31.2

34.3

47.6

55.5

66.0

82.0

74.0

-

Line Flowrate

gpm *

Line Flowrate

gpm *

Suction Flowrate

gpm *

Suction Flowrate

gpm *

PortsizeNPT/SAE

PortsizeNPT/SAE

* Flow rates with 150 SUS fluid viscosity

Filter AssemblyMPS 350MPS 351

Filter AssemblyMPS 350MPS 351

1 1/2"

1 1/2"

Page 15: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

CS 050-070

CS 100-150

CSG 050-070

CSG 100-150

CSG-W 050-070

CSG-W 100-150

TypeType

TypeType

TypeType

3/4" BSP

1-1/4" BSP

1"-12 UN

1-1/2" - 16 UN

1"-12 UN

1-1/2" - 16 UN

AA

AA

AA

Spin-On Elements

Water Removal

A

CS

EUROPEAN:

STANDARD - CANADA/USA:

STANDARD - CANADA/USA:

CSG

A

CSG-W

A

Thread Connection

Thread Connection

Thread Connection

1-14

Page 16: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Cross Sectional View1-15

1

1 HEAD

2 BYPASS VALVE

3 NO BYPASS PLUG

4 VISUAL INDICATOR (VACUUM-VS)

5 VISUAL INDICATOR (PRESSURE-VR)

6 ELECTRICAL INDICATOR

7 ELEMENT SEAL

8 ELEMENT

7

8

2

3

4

5

6

Page 17: Filtration - MP Filtri Canada · filtration level chosen (M60-M90-M250) MP Filtri recommends the pressure drop does not exceed 0.4 psi. Element Pressure Drop The following curves

Ordering Information MPSG Series

Replacement Element

MPSGMPSG 050050 RR G2G2

1-16

050070100150200250300350

A

V

MPSG

MPS

Nitrile (Buna-N)

Viton

North American

European

Type

G0

G2*

G3G4F2

U2

MPSG050/070

1/2" NPT3/4"NPT

SAE 121" NPT

1-1/4"NPT

MPSG100/150

1” NPT

SAE 20

MPSG200/250

1-1/2"NPT

SAE 24

MPSG300/350

1-1/2"NPT

SAE 24

1-1/2" SAE3000psi/UNC

U

RTS

Bypass 25 PSIDBypass 15 PSIDBypass 4.5 PSID

No bypass with 2 indicator ports

SERIES

NOMINAL SIZES

SEALS

A03

A06

A10

A25

P10

P25

M90

FILTER ELEMENTS

050070100

150

1 element for MPSG 0501 element for MPSG 0701 element for MPSG 1002 elements for MPSG 2002 elements for MPSG 3001 element for MPSG 1502 elements for MPSG 2502 elements for MPSG 350

NOMINAL SIZES

CSGCSG 050050 A03A03 AA

CSCSG

CSG-W

European Std. filter elementUSA Std. filter element

USA Std. filter element (050:100:150)water removal (paper only)

SERIES

PORT OPTIONS*

ELEMENT CONDITION INDICATOR

INTEGRAL BYPASS VALVE

A03A03 AA TT

3 micron absolute Inorganic microfibre ßx>75

6 micron absolute Inorganic microfibre ßx>75

10 micron absoluteInorganic microfibre ßx>75

25 micron absoluteInorganic microfibre ßx>75

10 micronResin-treated paper ßx>2

25 micronResin-treated paper ßx>2

Square wire mesh (164 mesh)

051071101151

--

301351

T

VR

VS

ER

EC

EO

With plug

Visual (pressure gauge)

Visual (vacuum gauge)

Electrical N.O. contacts

Electrical N.C. contacts

Electrical (vacuum

switch dual contacts.)

Indicators for Standard Filters (0)

T2

1V

V6

Z1

Z6

N1

N6

1E

E6

With plug

Visual 15 psi

Visual 30 psi

Visual 18 psi

Visual 30 psi

Electrical 18 psi

Electrical 30 psi

Visual-Electrical 18 psi

Visual-Electrical 30 psi

*For Differential Filter "G2" ports only available

Indicators for Differential Filters (1)

Standard Differential