Natural Gas Dryers for NGV Fueling Statio
NG SOLUTIONS
www.xebecinc.co
-
7/23/2019 Filtering e Ngx Brochure
2/8
NG SOLUTIONS
Dying ntul gs o todys NGV uling sttions
What you need to know...
ISO 15403:2000 Th singl most imotnt sty quimnt
ISO 15403:2000 (E) standard states (paragraph 5.1): The single most important saety requirement o compressed naturalgas (CNG) uel is a very low water dew point temperature to preclude the ormation o liquid water at any time. Liquid water is
the precursor to the ormation o corrosive compounds through combination with components in natural gas, namely carbondioxide and hydrogen sulphide. The combination o corrosive agents, and the pressure cycling, caused by uel consumption andsubsequent relling o the uel storage container, can result in crack growth in metals and ultimately damage and ailure. Also,liquid water itsel can be detrimental as it may cause blockages, both liquid and solid, in the uel system.
Thus, the water dew point o the uel gas at the ueling station outlet shall be suciently below the lowest ambient temperaturein which the ueling station and vehicles will operate.
I you think you gs is dy, you nd to d this
As the eects o moisture in natural gas systems are not always immediately evident, some NGV station builders are reluctantto address the importance o installing desiccant dryer systems in CNG uelling stations. This is despite the act that there areindustry standards and recommended practices or the required dew point o compressed natural gas used or uelling stations,
such as ISO 15403:2000(E).
The most common reason or not installing dryers in NGV stations is the belie that the gas is already dry. However, it should betaken into consideration that although the gas dew point may be as low as -40C in the pipeline at pipe pressure, the eects ocompression will aect the dew point o the gas.
Physical laws dictate that the dew point o a gas increases as its pressure increases. Thereore, although the dew point o thegas in a given pipeline may be very low when it reaches the compressor, it will be signicantly higher when the gas leaves thecompressor. This is why natural gas desiccant dryers are required in the majority o NGV stations in order to conorm to theISO 15403:2000(E) standard, specically in areas where lower temperatures are encountered during the colder winter months.
Sution sid vsus high ssu dishg dying thnology
Higher concentration o water vapor per volume o gas, caused by high compressor discharge temperatures, aects the
adsorption eciency o desiccant dryers which are installed on the pressure discharge side. Oil vapor ound at the outlet o theoil-lubricated compressor can contaminate the desiccant and cause dew point collapse. Lower temperatures and oil vapor reegas on the suction side result in better dryer perormance and lower maintenance cost.
Allowing wet gas to enter the compressor is undesirable, as most reciprocating compressors are extremely sensitive to liquidwater entering the compression cylinders, which can have catastrophic results on the entire compressor.
Pressure swing dryers use 10 15% o the dry gas rom their outlet to regenerate the o-line tower. This used gas must then berecovered on the suction side o the compressor, increasing its size and decreasing the output to the storage vessels and dispensers.This is not an economical solution as compared to the suction side dryer which does not utilize any purge gas.
2
-
7/23/2019 Filtering e Ngx Brochure
3/8
-
7/23/2019 Filtering e Ngx Brochure
4/8
Xebec aDSOrpTION INc. | 730 Boul. Industriel, Blainville (Quebec) CANADA J7C 3V4Toll F: 1-877-GO-XEBEC | phon: (450) 979-8700 | Fx: (450) 979-7869 | emil: [email protected]
STVNGX bsi Singl Tow Ntul Gs Dys
Ftus:
Low cost, low capacity basic package
External regeneration or desiccant replacement required
AutoDew is a highly recommended option
alitions:
Low to medium fows
Low to high pressure designs
Recommended or low throughput (water content) ueling needs
Maximum operating pressure = 135 psig (5 psig minimum). Higher operating pressures available upon request.CF = Consult Factory1 Flow conditions given or reerence only. Please consult actory or accurate sizing.
Modl No conntioncity (ox)
MMScF @ 7#H2O/MMScF(e3Nm3@ 112 mg H2O/m3) 1
Inlt Gs Flow(ox)
sm (Nm3/h)@ 100 sig (7 g) 1
aoximt Wight & Dimnsions
Widthinhs (mm)
Lngthinhs (mm)
Hightinhs (mm)
Wightls (kg)
STV6NGX-0.5 1/2" NPT 0.5 (13) 58 (93) 15 (381) 23 (584) 66 (1676) 250 (114)
STV8NGX-1 1" NPT 0.7 (19) 105 (169) 18 (457) 23 (584) 66 (1676) 350 (160)
STV10NGX-1 1" NPT 1.5 (40) 164 (264) 18 (457) 28 (711) 90 (2286) 600 (273)
STV14NGX-1.5 1-1/2" NPT 3.0 (80) 386 (620) 33 (838) 38 (965) 89 (2261) 900 (409)
STV14NGX-2 2" NPT 3.0 (80) 472 (759) 33 (838) 38 (965) 89 (2261) 900 (409)
STV18NGX-1.5 1-1/2" NPT 5.0 (134) 386 (620) 38 (965) 39 (991) 90 (2286) 1500 (682)
STV18NGX-2 2" NPT 5.0 (134) 636 (1022) 38 (965) 39 (991) 90 (2286) 1500 (682)
STV24NGX-2 2" NPT 10.0 (268) 636 (1022) 44 (1118) 44 (1118) 91 (2311) 2000 (910)
STV24NGX-3 3" FLG 10.0 (268) 1235 (1985) 53 (1346) 63 (1600) 92 (2337) 2200 (1000)
STV30NGX-2 2" FLG 15.1 (405) 636 (1022) 45 (1143) 46 (1168) 99 (2515) 2500 (1136)
STV30NGX-3 3" FLG 15.1 (405) 1402 (2253) 56 (1422) 63 (1600) 103 (2616) 2700 (1227)
STV36NGX-3 3" FLG 22.5 (603) 1402 (2253) CF CF CF CF
STV36NGX-4 4" FLG 22.5 (603) 2415 (3882) CF CF CF CF
autoDw otion:AutoDew is a precision dew point monitor with digital dew point indication (in C or F) installed at the dryercontrol panel. The AutoDew hygrometer displays the dew point data on a monitor on a NEMA 4 enclosure. The moisture sensor isinstalled at the dryer outlet to continuously veriy the dew point. Two AutoDew hygrometer set points are actory adjusted: the rst tosignal deteriorating dew point perormance and the second when regeneration is required. A set o orm C dry contacts are providedor remote signal monitoring. Alarm settings typically conorm to SAE J1616 or each installation.
4
-
7/23/2019 Filtering e Ngx Brochure
5/8
Ftus:
Comprehensive range o rugged, skid mounted single anddual tower regenerable natural gas dryers
Closed loop, operator initiated heat reactivated regeneratedcycles or reliable dryer regeneration control and shutdown
AutoDew is a standard eature and will signal whenregeneration is required
alitions:
Medium to high fows
Low to high pressure designs
Recommended or medium throughput ueling needs
Minimum downtime (no downtime required or duplex model)
Xebec aDSOrpTION INc. | 730 Boul. Industriel, Blainville (Quebec) CANADA J7C 3V4Toll F: 1-877-GO-XEBEC | phon: (450) 979-8700 | Fx: (450) 979-7869 | emil: [email protected]
STRNGX rgnl Singl Tow Ntul Gs Dys
also vill: A duplex version has an additional drying tower to eliminate downtime when regeneration is necessary.Switching between towers is perormed manually.
Modl No conntioncity (ox)
MMScF @ 7#H2O/MMScF(e3Nm3@ 112 mg H2O/m3) 1
Inlt Gs Flow(ox)
sm (Nm3/h)@ 100 sig (7 g) 1
aoximt Wight & Dimnsions
Widthinhs (mm)
Lngthinhs (mm)
Hightinhs (mm)
Wightls (kg)
STr14NGX-1.5 1-1/2" FLG 3.0 (80) 386 (620) 68 (1727) 83 (2108) 95 (2413) 2800 (1273)
STr14NGX-2 2" FLG 3.0 (80) 472 (759) 68 (1727) 83 (2108) 95 (2413) 2800 (1273)
STr18NGX-1.5 1-1/2" FLG 5.0 (134) 386 (620) 68 (1727) 83 (2108) 95 (2413) 3100 (1409)
STr18NGX-2 2" FLG 5.0 (134) 636 (1022) 68 (1727) 83 (2108) 95 (2413) 3100 (1409)
STr24NGX-2 2" FLG 10.0 (268) 636 (1022) 68 (1727) 83 (2108) 97 (2464) 4000 (1818)
STr24NGX-3 3" FLG 10.0 (268) 1235 (1985) 68 (1727) 83 (2108) 96 (2438) 4000 (1818)
STr30NGX-2 2" FLG 15.1 (405) 636 (1022) 71 (1803) 84 (2134) 104 (2642) 3570 (1623)
STr30NGX-3 3" FLG 15.1 (405) 1402 (2253) 71 (1803) 84 (2134) 104 (2642) 3570 (1623)
STr36NGX-3 3" FLG 22.5 (603) 1402 (2253) 96 (2438) 108 (2743) 126 (3200) 6600 (3000)
STr36NGX-4 4" FLG 22.5 (603) 2415 (3882) 99 (2515) 108 (2743) 126 (3200) 6600 (3000)
Maximum operating pressure = 135 psig (5 psig minimum). Higher operating pressures available upon request.1 Flow conditions given or reerence only. Please consult actory or accurate sizing.
-
7/23/2019 Filtering e Ngx Brochure
6/8
Xebec aDSOrpTION INc. | 730 Boul. Industriel, Blainville (Quebec) CANADA J7C 3V4Toll F: 1-877-GO-XEBEC | phon: (450) 979-8700 | Fx: (450) 979-7869 | emil: [email protected]
DTRNGX rgnl Twin Tow Ntul Gs Dys
Ftus:
Twin tower
Simplied design ully automatic regeneration
Compact design
All models complete with regeneration package
Limited in pressure and fow capacity
AutoDew is standard
alitions:
Low to medium fows
Low to medium pressure designs
Recommended or medium throughput ueling needs
No downtime
Maximum operating pressure = 135 psig (5 psig minimum). Higher operating pressures available upon request.1 Flow conditions given or reerence only. Please consult actory or accurate sizing.
Modl No conntioncity (ox)
MMScF @ 7#H2O/MMScF(e3Nm3@ 112 mg H2O/m3) 1
Inlt Gs Flow(ox)
sm (Nm3/h)@ 100 sig (7 g) 1
aoximt Wight & Dimnsions
Widthinhs (mm)
Lngthinhs (mm)
Hightinhs (mm)
Wightls (kg)
DTra14NGX-1.5 1-1/2" FLG 3.0 (80) 386 (620) 81 (2057) 88 (2235) 96 (2438) 4090 (1860)
DTra14NGX-2 2" FLG 3.0 (80) 472 (759) 81 (2057) 88 (2235) 96 (2438) 4090 (1860)
DTra18NGX-1.5 1-1/2" FLG 5.0 (134) 386 (620) 86 (2184) 88 (2235) 96 (2438) 4818 (2190)
DTra18NGX-2 2" FLG 5.0 (134) 636 (1022) 86 (2184) 88 (2235) 96 (2438) 4818 (2190)
DTra24NGX-2 2" FLG 10.0 (268) 636 (1022) 90 (2286) 130 (3302) 113 (2870) 5610 (2550)
DTra24NGX-3 3" FLG 10.0 (268) 1235 (1985) 90 (2286) 130 (3302) 113 (2870) 5610 (2550)
DTra30NGX-2 2" FLG 15.1 (405) 636 (1022) 90 (2286) 150 (3810) 113 (2870) 7040 (3200)
DTra30NGX-3 3" FLG 15.1 (405) 1402 (2253) 90 (2286) 150 (3810) 113 (2870) 7040 (3200)
6
-
7/23/2019 Filtering e Ngx Brochure
7/8
Xebec aDSOrpTION INc. | 730 Boul. Industriel, Blainville (Quebec) CANADA J7C 3V4Toll F: 1-877-GO-XEBEC | phon: (450) 979-8700 | Fx: (450) 979-7869 | emil: [email protected]
Ftus:
Designed and engineered or large fowsand continuous duty cycles
Fully automatic and maximized desiccant regeneration,dew point perormance and energy eciency
Large LCD text display shows dryer statusand alarms at all times
Custom designed to meet all levels o specications
AutoDew is standard
alitions:
Medium to high fows
Low to high pressure designs
Recommended or mediumto high throughput ueling needs
No downtime
HRBNGX Fully automti Ht rtivtdTwin Tow Ntul Gs Dys
Maximum operating pressure = 135 psig (5 psig minimum). Higher operating pressures available upon request.1 Flow conditions given or reerence only. Please consult actory or accurate sizing.
Modl No conntioncity (ox)
MMScF @ 7#H2O/MMScF(e3Nm3@ 112 mg H2O/m3) 1
Inlt Gs Flow(ox)
sm (Nm3/h)@ 100 sig (7 g) 1
aoximt Wight & Dimnsions
80HrbNGX 2" FLG 10.0 (268) 636 (1022) Consult actory or dimensions
200HrbNGX 3" FLG 15.1 (405) 1402 (2253) Consult actory or dimensions
300HrbNGX 4" FLG 22.5 (603) 2415 (3882) Consult actory or dimensions
400HrbNGX 4" FLG 33.8 (905) 2415 (3882) Consult actory or dimensions
500HrbNGX 6" FLG 33.8 (905) 4480 (7201) Consult actory or dimensions
600HrbNGX 6" FLG 45.0 (1205) 5480 (8808) Consult actory or dimensions
750HrbNGX 8" FLG 56.3 (1508) 7550 (12135) Consult actory or dimensions
1000HrbNGX 8" FLG 71.3 (1910) 8900 (14305) Consult actory or dimensions
-
7/23/2019 Filtering e Ngx Brochure
8/8
X flttion solutions inlud: Wid ng o ssois vill:
Gas lters
Engineered anged lters
Water separators
High pressure lters
Stainless steel process lters
Landll and biogas lters
Filter elements
Dew point sensors
Desiccant
Drains
Valves
Differential pressure switches
Pressure gauges
www.xebecinc.com
committd to fst lss ustom svi.
cll Toll-F: 1-877-GO-XEBECemil: [email protected]
Xebec stands behind the service, spare parts
and technical support needed to ensure
the most complete and eective solution
or every installation throughout the world.
SaLeS OFFIceSblinvill, Qu, caNaDa
730 Boul. Industriel, J7C 3V4
Phone: (450) 979-8700
Email: [email protected]
buny, bitish columi, caNaDa
6961 Russell Avenue, V5J 4R8
Phone: (604) 454-1134
Email: [email protected]
Nwstl, UNITeD KINGDOM
Quorum 16, Balliol Business Park East
Benton Lane, NE12 8BX
Phone: +44 (0) 191 215 5070
Email: [email protected]
Shnghi, cHINa
No. 92 Jiang Tian Dong Road
Songjiang Industrial Zone
Phone: +86 21 3352 8700
Email: [email protected]
SINGapOre
No. 63 Ubi Ave 1, #06-05
Boustead House, 408937
Phone: +65 6748 7988
Email: [email protected]
XEBEC ADSORPTION INC. WORLDWIDE CORPORATE HEADQUARTERS
730 Boul. Industriel, Blainville, Quebec J7C 3V4 Canada
Toll Free: 1-877-GO-XEBEC
Phone: (450) 979-8700
Fax: (450) 979-7869
Email: [email protected]: www.xebecinc.com