[File Name or Event] Emerson Confidential 27-Jun-01, Slide 1 Slide 1 Travel Sensor Is Factory Adjusted Travel Sensor Is Factory Adjusted The placement of the feedback arm on the travel sensor is factory adjusted and sealed with anti-tamper paint. This setting has been tested for functionality successfully several times before the DVC6000 ships from the factory. Do not assume this setting is wrong. Check everything else first before disturbing the anti- tamper paint. Anti-Tamper Paint

Transcript of [File Name or Event] Emerson Confidential 27-Jun-01, Slide 1 Slide 1 Travel Sensor Is Factory...

[File Name or Event]Emerson Confidential27-Jun-01, Slide 1

Slide 1

Travel Sensor Is Factory AdjustedTravel Sensor Is Factory AdjustedTravel Sensor Is Factory AdjustedTravel Sensor Is Factory Adjusted The placement of the feedback

arm on the travel sensor is factory adjusted and sealed with anti-tamper paint.

This setting has been tested for functionality successfully several times before the DVC6000 ships from the factory.

Do not assume this setting is wrong.

Check everything else first before disturbing the anti-tamper paint.

Anti-TamperPaint

[File Name or Event]Emerson Confidential27-Jun-01, Slide 2

Slide 2

DVC6000 – Potentiometer IssuesDVC6000 – Potentiometer IssuesDVC6000 – Potentiometer IssuesDVC6000 – Potentiometer Issues

Potentiometer Components

[File Name or Event]Emerson Confidential27-Jun-01, Slide 3

Slide 3

Vibration Induced Potentiometer WearVibration Induced Potentiometer WearVibration Induced Potentiometer WearVibration Induced Potentiometer Wear Some control systems are not grounded Valve Travels in Higher Resistance Area (80 –

90% travel) Amplification of travel noise by velocity gain in

the DVC tuning ( Reduce affect by changing to velocity gain of 0)

[File Name or Event]Emerson Confidential27-Jun-01, Slide 4

Slide 4

No Potentiometer Wear No Potentiometer Wear No Potentiometer Wear No Potentiometer Wear

[File Name or Event]Emerson Confidential27-Jun-01, Slide 5

Slide 5

ValveLink Graph with Potentiometer Wear-ValveLink Graph with Potentiometer Wear-Thru Thru ValveLink Graph with Potentiometer Wear-ValveLink Graph with Potentiometer Wear-Thru Thru

[File Name or Event]Emerson Confidential27-Jun-01, Slide 6

Slide 6

Profile TestProfile TestProfile TestProfile Test Requires PD Tier

[File Name or Event]Emerson Confidential27-Jun-01, Slide 7

Slide 7

PD Profile No problems PD Profile No problems PD Profile No problems PD Profile No problems

[File Name or Event]Emerson Confidential27-Jun-01, Slide 8

Slide 8

PD Profile Test Showing Early WearPD Profile Test Showing Early WearPD Profile Test Showing Early WearPD Profile Test Showing Early Wear

[File Name or Event]Emerson Confidential27-Jun-01, Slide 9

Slide 9

Increase Reliability with Linkage-less feedbackIncrease Reliability with Linkage-less feedbackIncrease Reliability with Linkage-less feedbackIncrease Reliability with Linkage-less feedback

Best to remove potential wear points all together

Unique linkage-less non-contact design– Feedback components

never touch the instrument

– DVC2000• Released in 2004

– DVC6200 HART

– DVC6200f FOUNDATION Fieldbus

No Linkages

Feedback Arrays

[File Name or Event]Emerson Confidential27-Jun-01, Slide 10

Slide 10

DVC6200 - Product DetailsDVC6200 - Product DetailsDVC6200 - Product DetailsDVC6200 - Product Details Differences between the DVC6200 & the

DVC6000– Hall sensor in place of the feedback potentiometer– Terminal box moves to the left side of the housing– New mounting kits (same design as DVC2000 kits)– HART: Firmware 10 required– FOUNDATION fieldbus: new PWB and terminal box

required

[File Name or Event]Emerson Confidential27-Jun-01, Slide 11

Slide 11

DVC6200 - Mounting KitsDVC6200 - Mounting KitsDVC6200 - Mounting KitsDVC6200 - Mounting Kits Bolt patterns for DVC2000 and DVC6200 are

identical Existing DVC2000 mounting kits are being

updated– 1 standard kit for both DVC6200 and DVC2000– Stronger brackets will replace the existing brackets

to accommodate additional weight New curved array

– For use with the existing long stroke cams– For Fisher rotary actuator window

1”, 2” & 4” array

Rotary Magnet

Curved array

[File Name or Event]Emerson Confidential27-Jun-01, Slide 12

Slide 12

Long Stroke Mounting Long Stroke Mounting Long Stroke Mounting Long Stroke Mounting

Anti-rotation

[File Name or Event]Emerson Confidential27-Jun-01, Slide 13

Slide 13

Dual Mounting BracketDual Mounting BracketDual Mounting BracketDual Mounting Bracket

[File Name or Event]Emerson Confidential27-Jun-01, Slide 14

Slide 14

DVC6205/6215 Remote MountDVC6205/6215 Remote MountDVC6205/6215 Remote MountDVC6205/6215 Remote Mount

[File Name or Event]Emerson Confidential27-Jun-01, Slide 15

Slide 15

Terminal BoxesTerminal BoxesTerminal BoxesTerminal Boxes

1. Power 4V to 30V

2. Feedback 0-.5 V normal

3. DVC6215 Ground

4. Status Line

[File Name or Event]Emerson Confidential27-Jun-01, Slide 16

Slide 16

Design EngineeringDesign EngineeringDesign EngineeringDesign Engineering

Used for Temperature Calibration -52 to 125 Deg C

[File Name or Event]Emerson Confidential27-Jun-01, Slide 17

Slide 17

Remote Mount ComponentsRemote Mount ComponentsRemote Mount ComponentsRemote Mount Components

ValveLink Mobile

[File Name or Event]Emerson Confidential27-Jun-01, Slide 19

Slide 19

ValveLink MobileValveLink MobileValveLink MobileValveLink Mobile

Bluetooth Communications to a HART modem

Developed for Windows Mobile platform

Very compact, portable platform for local configuration, calibration, and diagnostics.

Integration into Emerson 375 / 475 platform

[File Name or Event]Emerson Confidential27-Jun-01, Slide 20

Slide 20

ValveLink Mobile 2.0ValveLink Mobile 2.0ValveLink Mobile 2.0ValveLink Mobile 2.0

Icon Driven User Interface

Common Tasks Located on Home Screen.

High Contrast for Outdoor Viewing.

Thumb Driven Interface - No Stylus Required.

Preprogrammed diagnostics. Tests can be run, saved, and uploaded later to ValveLink or AMS.

[File Name or Event]Emerson Confidential27-Jun-01, Slide 21

Slide 21

ValveLink Mobile on 375 / 475ValveLink Mobile on 375 / 475ValveLink Mobile on 375 / 475ValveLink Mobile on 375 / 475

Same interface as on PDA and Smartphone platforms.

FAST configuration, calibration, and diagnostics.

[File Name or Event]Emerson Confidential27-Jun-01, Slide 22

Slide 22

Diagnostics on the 375 / 475Diagnostics on the 375 / 475Diagnostics on the 375 / 475Diagnostics on the 375 / 475

Total Scan Step Response PD Diagnostics Valve Signature Step Study 1 Button Sweep Dynamic Error Band Stroking Speed PD Traces

[File Name or Event]Emerson Confidential27-Jun-01, Slide 23

Slide 23

Valve Diagnostic ChangesValve Diagnostic ChangesValve Diagnostic ChangesValve Diagnostic Changes

[File Name or Event]Emerson Confidential27-Jun-01, Slide 24

Slide 24

PD DiagnosticsPD DiagnosticsPD DiagnosticsPD Diagnostics

[File Name or Event]Emerson Confidential27-Jun-01, Slide 25

Slide 25

Import Field Data into ValveLinkImport Field Data into ValveLink(Upload to the mother ship)(Upload to the mother ship)Import Field Data into ValveLinkImport Field Data into ValveLink(Upload to the mother ship)(Upload to the mother ship)

ValveLink Support

[File Name or Event]Emerson Confidential27-Jun-01, Slide 27

Slide 27

ValveLink 12 License ChangesValveLink 12 License ChangesValveLink 12 License ChangesValveLink 12 License Changes Planning on free Version with 12.0 targeted for Oct.

– Install on Multiple PC’s

– No additional license key required

– Connect to 1 device at a time

– Database is limited to one tag

– Supports HART & Ff

[File Name or Event]Emerson Confidential27-Jun-01, Slide 28

Slide 28

ValveLink SupportValveLink SupportValveLink SupportValveLink Support $405 per year Includes License Support, New Software CD,

and Web Based FTP Access ftp://ftp2.emersonprocess.com/