Figured dimensions are to be used in all case. Dimensions ...

1
112.6 m² 06:0/001 6th Form Study Room 48.8 m² 06:0/002 6th Form Common Room 51.4 m² 06:0/003 6th Form Common Room 44.2 m² 01:0/053 6th Form Common Room 8.0 m² 01:0/051 Office 68.6 m² 01:0/045 ICT Classroom 22.5 m² 01:0/046 Yr 7,8,9 Learning Coach Provision 14.1 m² 01:0/048 Circ. 28.7 m² 03:0/001 Circ. 12.4 m² 03:0/004 Bar Store 7.6 m² 03:0/038 Office 4.1 m² 03:0/006 Snack Bar 3.8 m² 03:0/007 Store 40.5 m² 01:0/044 Circ. New Fire Escape access to proposed carpark Additional 2 no. accessible parking bays provided within existing carpark adjacent to the main entrance of the school Outer red brick work skin added to match existing adjacent building New insulated roller shutter door Existing Vehicle Access from Stryt Isa 35 no. parking spaces- refer to Landscape drawings 35.2 m² 03:0/005A Nurture Classroom 18.4 m² 03:0/035 Boys W.C. 55.0 m² 03:0/003 Circ. Gender Neutral WCs_01 Gender Neutral WCs_02 Area shown within dotted blue boundary will need to be fire rated- including existing door into 6th Form Study Room- fire officer to confirm Caretaker Store Zone 01 Demolition & Proposed Carpark Zone 02 proposed new build Zone 03 Refurbishment Rev. Drawn Title Project Drawing number Rev. Revision description Checked Date VISUAL SCALE 1:100 @ A1 2m 8m 6m 4m 0m Lovelock Mitchell Architects 3 Stanley Street, Chester, CH1 2LS Tel +44 (0) 1244 404321 e-mail: [email protected] web: www.lovelockmitchell.com Notes Figured dimensions are to be used in all case. Dimensions should not be scaled from drawing All existing dimensions should be checked on site before commencement of the work. Any discrepancies in dimensions should be clarified with the Architect prior to commencement of the work. No deviation from this drawing will be permitted without the prior written consent of the Architect. This drawing is to be read in conjunction with all the relevant Mechanical and Electrical drawings. This drawing is to be read in conjunction with the relevant Structural Engineer's drawings, structural calculations and recommendations. This drawing is to be read in conjunction with the relevant Fire Safety Strategy drawings This drawing is copyright and to be returned to the architect on completion of the contract. LMA Project A1 P3 C:\Revit_Local\CAS-LMA-02-XX-M3-A-0001_Model_Building_Existing_Evie.greenallKL9T3.rvt Castell Alun School Fagl Ln, Hope, Wrexham, LL12 9PY GA_Plan_00Ground_Zone01_Proposed 1590 CAS-LMA-02-00-DR-A-2011 P1 Planning Issue EG TR 19-12-06 P2 General Updates Inline with Stage04 Pricing Info Issue EG TR 19-12-23 P3 Amended Planning Issue EG TR 20-05-01 Scale: 1 : 100 GA_Plan_00Ground_Zone01_Proposed 1 Key Plan_Zoning NOTE For landscaping proposals refer to drawings: Zone 01 CAH-LST-XX-XX-M3-L-2000 Zone 02 CAH-LST-XX-XX-M3-L-2001 N

Transcript of Figured dimensions are to be used in all case. Dimensions ...

112.6 m²

06:0/0016th Form Study Room

48.8 m²

06:0/0026th Form Common Room

51.4 m²

06:0/0036th Form Common Room

44.2 m²

01:0/0536th Form Common Room

8.0 m²

01:0/051Office

68.6 m²

01:0/045ICT Classroom

22.5 m²

01:0/046Yr 7,8,9 Learning Coach

Provision

14.1 m²

01:0/048Circ.

28.7 m²

03:0/001Circ.

12.4 m²

03:0/004Bar Store

7.6 m²

03:0/038Office

4.1 m²

03:0/006Snack Bar

3.8 m²

03:0/007Store

40.5 m²

01:0/044Circ.

New Fire Escape access to proposed

carpark

Additional 2 no. accessible parking bays provided within existing carpark adjacent to the main entrance of the school

Outer red brick work skin added to match

existing adjacent building

New insulated roller shutter door

Existing Vehicle Access from Stryt Isa

35 no. parking spaces- refer to Landscape drawings

35.2 m²

03:0/005ANurture Classroom

18.4 m²

03:0/035Boys W.C.

55.0 m²

03:0/003Circ.

Gender Neutral WCs_01 Gender Neutral WCs_02

Area shown within dotted blue boundary will need to be fire rated- including existing door into 6th Form Study Room- fire officer to confirm

Caretaker Store

Zone 01Demolition &

Proposed Carpark

Zone 02 proposed new build

Zone 03Refurbishment

Rev.

Drawn

Title

Project

Drawing number

Rev. Revision description Checked Date

VISUAL SCALE 1:100 @ A1

2m 8m6m4m0m

Lovelock Mitchell Architects3 Stanley Street, Chester, CH1 2LS

Tel +44 (0) 1244 404321

e-mail: [email protected]: www.lovelockmitchell.com

Notes

Figured dimensions are to be used in all case.Dimensions should not be scaled from drawing All existing dimensions should be checked on site before commencement of the work. Any discrepancies in dimensions should be clarified with the Architect prior to commencement of the work.No deviation from this drawing will be permitted without the prior written consent of the Architect.This drawing is to be read in conjunction with all the relevant Mechanical and Electrical drawings.This drawing is to be read in conjunction with the relevant Structural Engineer's drawings, structural calculations and recommendations.This drawing is to be read in conjunction with the relevant Fire Safety Strategy drawings

This drawing is copyright and to be returned to the architect on completion of the contract.

LMA Project

A1

P3

C:\Revit_Local\CAS-LMA-02-XX-M3-A-0001_Model_Building_Existing_Evie.greenallKL9T3.rvt

Castell Alun SchoolFagl Ln, Hope, Wrexham, LL12 9PY

GA_Plan_00Ground_Zone01_Proposed

1590 CAS-LMA-02-00-DR-A-2011

P1 Planning Issue EG TR 19-12-06

P2 General Updates Inline with Stage04 Pricing InfoIssue

EG TR 19-12-23

P3 Amended Planning Issue EG TR 20-05-01

Scale: 1 : 100

GA_Plan_00Ground_Zone01_Proposed1

Key Plan_Zoning

NOTEFor landscaping proposals refer to drawings:

Zone 01CAH-LST-XX-XX-M3-L-2000

Zone 02CAH-LST-XX-XX-M3-L-2001

N