Introducing Agilent N9343C/N9344C
Page 1
Agilent HSA series handheld spectrum analyzer
Field testing just got easier
N9344C1 MHz to 20 GHz
N9343C1 MHz to 13.6 GHz
N9342C100 kHz to 7 GHz
N9340B100 kHz to 3 GHz
Page 2
Field ready
Complies with MIL-PRF-28800F Class 2
Maximum 4 hours operation time
Rugged and fanless design for tough field environment
Industry first! Clear viewing both day and night with automatic LCD brightness control and keypad backlight
The only handheld with GPS receiver and GPS antenna both built-in
Flexible remote control via USB/LAN
Introducing Agilent N9343C/N9344C
Leveraging Agilent Cutting-edge Technology
Page 3
Algorithms / Components / sub-systems
Handheld Portability Ease of use General purpose
Bench Performance Broad applications
Agilent Lab Breakthrough Technology
Introducing Agilent N9343C/N9344C
Page 4
Benchtop performance in a handheld
Best-in-class DANL: -151 dBm/Hz at 18 GHz
High accuracy peak and average power measurement with Agilent U2020 and U2000 series USB power sensor
Fastest sweep: < 0.9 s for 20 GHz span
Introducing Agilent N9343C/N9344C
Autotune in a Handheld!
Find, tune, and zoom on the signal with a single button push:
Time-gating
Page 6
Introducing Agilent N9343C/N9344C
Time-gated spectrum analysis (option TMG)
• Measure pulsed-RF• Gate source: external, periodic
timer, RF burst
AM/FM modulation analysis
Page 7
Introducing Agilent N9343C/N9344C
ASK/FSK Modulation AnalysisOption DMA: provides the modulation metrics of ASK/FSK modulated signals – Industry exclusive
ASK/FSK Modulation Analysis (cont’d)
Eye diagram
Option DMA: provides the modulation metrics of ASK/FSK modulated signals – Industry exclusive
Symbol
Error rate
Waveform
Four types of display
Chart mode Meter mode
Two channel power display modes:
Channel Power Meter
Page 11
High accuracy power measurement with Agilent U2000 series USB power sensor (Option PWM)
Support Agilent U2000 series power sensors
Frequency range: 9 kHz to 24 GHz (sensor dependent)
Dynamic range: -60 dBm to +20 dBm
The user can set up, calibrate and control the power sensor via the N9340B.
2 display modes: Meter or Chart.
Limit function
Introducing Agilent N9343C/N9344C
Page 12
IMT_300 Easier Introducing the N9342C HSA Agilent Restricted
Option PWP – U2020 X-series USB peak and average power sensor support
World’s fastest USB power sensor now works with the HSA! U2021XA: 50 MHz – 18 GHzU2022XA: 50 MHz – 40 GHzDynamic range: -35 to + 20 dBmMeasurement speed: 3500 readings/s
Trace mode Meter mode Chart mode
Page 13
Power suite (standard feature)
Standard featureChannel standard available
Extra LARGE Font presents a METER style
Introducing Agilent N9343C/N9344C
Page 14
Two-port insertion loss measurements(Opt TG7)
Measure two-port transmission of filter and amplifiers, e.g. insertion loss, amplifier gain, and filter passband.
Frequency range: 5 MHz – 7 GHz (tunable to 100 kHz)
The tracking generator output level is adjustable (–20 dBm to 0 dBm)
Introducing Agilent N9343C/N9344C
Cable & Antenna Test*
Reflection measurement – return loss, VSWR, and reflection coefficient
One-port cable loss
*Exclusive to N9342C - 5 MHz to 7 GHz
Option CA7:The essential tool for cable & antenna installation and maintenance
Distance-to-fault Dual view of distance-to-fault and reflection measurement
*Exclusive to N9342C - 5 MHz to 7 GHz
Cable & Antenna Test*
Page 17
Task Planner
Introducing Agilent N9343C/N9344C
Create the task plan file with the free
HSA PC software
Load the task plan file and
HSA will execute tests automatically
Report will be generated
with test results
captured
Reduces test setup time by 95%
Delivers test automation and consistency
Continuous execution of up to 20 different tests
Automatically capture test results and generate report
Share the task plan file easily via email or USB memory stick
For more info, go to www.agilent.com/find/taskplanner
First in industry!
RF Site Survey Measurementsusing the N934xC Series HSA
What is a Site Survey?
Channel Scan/ Drive TestInterference Analysis
Page 20
Spectrum monitoring and Interference analyzing with (Option SIM)
Spectrogram/trace view• Spectrogram displays 3-dimensions of the spectrum:
frequency, amplitude, and time• Three display modes: spectrogram only, spectrum trace
only, and dual-view
Spectrogram record and playback• Records spectrogram data to both internal memory and
external USB memory stick, and playback on instrument
• Record time depends on sweep interval
See more details• Two markers available to display frequency, amplitude
and time information• Provides limit lines with pass/fail functionality• Audio alert to indicate signal strength in a specified
frequency range• GPS information can be tagged to spectrogram data.
Spectrogram record (20 GHz full span)
Update interval Recording time by one .trc file (1500 frames Max, 4 MB)
1 second Approximately 50 minutes
10 seconds Approximately 4.5 hours
30 seconds Approximately 12.8 hours
300 seconds (5 minutes)
Approximately 5 days
Introducing Agilent N9343C/N9344C
Site Surveys and Spectrum Clearing• Identify and locate sources of undesired/unlicensed transmissions
• Signals can be continuous or transient
Agilent Application Note:Interference Testing with Handheld Spectrum Analyzers
Desired Signal
Interference
Key Requirements for Site Surveys
Frequency Range
Displayed Average Noise Level (DANL)
Third Order Intercept (TOI) +13 dBm
Spurious
Internal low-noise preamplifier
Wideband digitally modulated signal
Spurious
10dBRBW =100kHz
RBW =10kHz
RBW =100 kHz for both
Pre-amp OFF; 10dB attenuation Pre-amp ON; 0dB attenuation
HSA Detector Types
Normal Average (RMS) Peak
Average (RMS)
Normal and Power Average (RMS) Peak and Power Average (RMS)
Antenna Characteristics
• Site Survey - antenna similar to the actual system
• Weak Signals - high gain antenna
• Interferers - high gain antenna for direction finding
Amplitude Correction and Field Strength Units
Amplitude Correction = loss + gain
Data Sampling
Length and rate of data logging are related to type of transmissions: continuous, periodic, randomLog measurements as image files (jpg, bmp) or text files (CSV)
GPS Location Stamping• Agilent N934xC HSA optional built-in GPS receiver and antenna
• Data is date/time and GPS stamped
• Internal GPS antenna; optional external mag-mount GPS antennaN934xC Display
CSV Formatted File
Channel Scanner
Option SCN – a great tool for site survey / drive test, band clearance, and spectrum monitoring
Measures channel power of up to 20 different channels!
Toggles between horizontal and vertical displays according to the number of channels
Scan modes – Top/Bottom N and List
Top/Bottom NList
Channel Scanner (cont’d)
Two display modes
Bar chart Time chart
Channel Scanner (cont’d)
Data Mapping with Google Earth and MapInfo
- Captures data with Channel Scanner & Marker logging
- Generates data files to use with Google Earth and MapInfo
Recorded Channel Data
Signal Strength Mapping
Signal Strength Mapping