CAUTION: For safety and proper operation, read and follow instructions carefully before installation. IMPORTANT SAFEGUARDS 1.READ AND FOLLOW ALL SAFETY INSTRUCTIONS 2. e or circuit breaker. 3. Do not disconnect the wire harness with AC power present. To reduce the risk of electrical shock, discon- nect AC power and unplug test switch/pilot light connector before servicing. 4. - nel. 5. Consult your local building code for approved wiring and installation. 6. Do not use standard product outdoors. This product is for use with indoo xtures sealed or unsealed, except air handling heated outlets or hazardous location applications. 7. The emergency ballast must be connected to an unswitched AC power source (120 or 277). 8. Do not mount near gas or electric heater. 9. Do not attempt to service the battery. A sealed no- maintenance battery is used that is no eld replaceable. Contact manufacturer for service information. 10.Equipment should be mounted in location and at heights where it will not readily be subjected to tampering by unauthorized personnel. 11.The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 12.Do not use this equipment for other than intended use. SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PSQ500, PS600, PS1400 CAUTION: A potential electrical shock hazard exists even Disconnect polarized Test Switch/Pilot Light connector before servicing Do not remove the wire harness connector when AC power is present. FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS UNIVERSALLY COMPATIBLE WITH THE BALLASTS AND OPERATING LAMP(S) IN THE LAMP COMPATIBILITY TABLE (PAGE 3). APPROXIMATE WORKING VOLTAGE Battery Pack input: 120 OR 277V AC IMPORTANT NOTES: Make sure that branch circuit feeds are derived from a common phase for both normal lighting ballast and Battery Pack prior to installation. Notice: To ensure proper grounding, mount unit only with metal cutting screws (not provided). The Battery Pack can be used with a switched or unswitched (night) circuit. When used with a switched it is important to note that the power to the Battery Pack must be provided by an unswitched circuit. 7 Patent Numbers 5,814,971 6,522,147 6,577,136 D550,154

Transcript of FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

Page 1: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

CAUTION: For safety and proper operation, read and follow instructions carefully before installation.

IMPORTANT SAFEGUARDS

1.READ AND FOLLOW ALLSAFETY INSTRUCTIONS

2. eor circuit breaker.

3. Do not disconnect the wire harness with AC powerpresent. To reduce the risk of electrical shock, discon-nect AC power and unplug test switch/pilot lightconnector before servicing.

4. -nel.

5. Consult your local building code for approved wiringand installation.

6. Do not use standard product outdoors. This product isfor use with indoo xtures sealed or unsealed, exceptair handling heated outlets or hazardous locationapplications.

7. The emergency ballast must be connected to anunswitched AC power source (120 or 277).

8. Do not mount near gas or electric heater. 9. Do not attempt to service the battery. A sealed no-

maintenance battery is used that is no eld replaceable.Contact manufacturer for service information.

10.Equipment should be mounted in location and at heightswhere it will not readily be subjected to tampering byunauthorized personnel.

11.The use of accessory equipment not recommended bythe manufacturer may cause an unsafe condition.

12.Do not use this equipment for other than intended use.

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONSEMERGENCY FLUORESCENT BATTERY PACK

MODEL PS300, PSQ500, PS600, PS1400

CAUTION:A potential electrical shock hazard exists even

Disconnect polarized Test Switch/Pilot Lightconnector before servicing Do notremove the wire harness connector when ACpower is present.

FIELD INSTALLABLE FLUORESCENT BATTERYPACK IS UNIVERSALLY COMPATIBLE WITH THEBALLASTS AND OPERATING LAMP(S) IN THELAMP COMPATIBILITY TABLE (PAGE 3).

APPROXIMATE WORKING VOLTAGEBattery Pack input: 120 OR 277V AC

IMPORTANT NOTES:Make sure that branch circuit feeds are derived froma common phase for both normal lighting ballast andBattery Pack prior to installation.

Notice: To ensure proper grounding, mount unit onlywith metal cutting screws (not provided).

The Battery Pack can be used with a switched orunswitched (night) circuit. When used with a switched

it is important to note that the power to theBattery Pack must be provided by an unswitchedcircuit.

7

Patent Numbers5,814,9716,522,1476,577,136D550,154

Page 2: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

INSTALLATION 1. Turn AC Power. Inspect Battery Pack and make sure

the Test Switch/Pilot Light Connector and wire harnessconnector are both disconnected. If still connected,disconnect them before installation.

2. Position unit in wireway and fasten securelythrough keyed slots or Mounting Holes or Slots . Ifnecessary, drill holes and mount with metal cuttingscrews (not provided).

3. Attach and fully engage the wire harness connector tothe battery pack power connector .

HOUSINGMOUNTING HOLES orSLOTSTEST SWITCH/PILOTLIGHT (TS/PL)MOUNTING CLIPTS/PL CONNECTORCHARGE INDICATORSTICKER

PARTS DESCRIPTIONFIGURE 1

LAMP SELECTORSWITCH (PS1400 ONLY)WIRE HARNESS/PLUG

BATTERY PACK POWERCONNECTORTS/PL LABEL

TEST SWITCH/PILOT LIGHT (TS/PL)INSTALLATION

CAUTION: Do not locate Test Switch/Pilot Light or route cable within1” of lamps.

NOTE: If pilot light is not visible outside the lens, thereis a charge indicator sticker located in pre-pack that shouldbe placed on the side of the lens directly below the testswitch pilot light to identify it as an emergency

1. Drill or punch a 1/2” diameter hole in wall or wireway cover.

2. Insert one side of TS/PL into the hole from the backand snap in the other side. Slide mounting clip yonto mounting post to secure TS/PL assembly. Mark theTS/PL location with the TS/PL label .

Page 2

NOTE: Allow battery to charge 24 hours before initial testingand 72 hours to fully charge battery.

NOTE: Emergency lighting systems should be tested as oftenas local codes require, or at least quarterly to insure that allcomponents are operational. Perform all test required by localcodes.

1. Check equipment rating to be sure that will receiveproper line voltage.

2. Be sure pilot light is on. If pilot light does not operate,check to see that:

A. Test Switch/Pilot Light Connector is connected.

B. AC power is on and wire harness is fully engagedinto battery pack power connector .

C. Voltage on branch circuit to Battery Pack is ratedat line voltage (120V or 277V). If no line voltage can bemeasured, locate problem in branch circuit and correct.

3. Press test switch. The pilot light should be One (allmodels) or two (PS600 and PS1400 only) lamps should be operating at a reduced light output.

INSPECTION AND MAINTENANCE

NOTE: Battery packs are not serviceable units.

CAUTION:Damage to battery will occur if Test Switch/Pilot Lightconnection is made for a prolonged period of timewithout AC power provided.

CAUTION:Connecting the Test Switch/Pilot Light Connector alsoconnects the battery to the inverter circuit which canresult in high voltage being present between the outputleads.

3. Connect and fully engage the Test Switch/Pilot LightConnector to the battery pack.

4. Apply continuous power to Battery Pack.

4. Refer to appropriate wiring diagram. Connect unit toballast and lamp(s) and A.C. power leads as indicated inappropriate wiring diagram.

CAUTION:Connector must be fully engaged and latched before ACpower is applied.

www.powersentrysafety.com1-888-300-7017

Page 3: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

Page 3

Note: Lamp selector switch is located under perforated tab on product label. Battery pack shipped with switchin “DOWN” position.

LAMP SELECTOR TABLE - PS1400 ONLYNOTE: The PS1400 has a lamp selector switch which can be used to optimize performance when placed inthe “down” position. However, please note, based on your lamp the PS1400 can only be placedin the “down” position if so designated in the lamp selector table.WARNING: Lamp Type/Switch Selector Combinations not listed in the lamp table could damage unit and void warranty.

NOITISOP PUNOITISOP NWOD

White button must beremoved before “Up”position can be achieved

7 7

www.powersentrysafety.com1-888-300-7017

Page 4: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

FIGURE A

ONE LAMP RAPID START BALLAST

LAMP COMPATIBILITY TABLE

1 - Indicates one lamp operation in emergency mode2 - Indicates two lamp operation in emergency mode

LAMP TYPE WATTAGE PS300 PSQ500 PS600 PS1400 (300 lumens) (500 lumens) (600 lumens) (1100-1400 lumens)

1182 - 415T ”84 - ”421145 - 425T OH ”84 - ”42

U-LAMP T8 16 - 31 1 1 1,2 1,224"-48" T8 17 - 32 1 1 1,2 1,2

1195 - 048T "69-"0611688T OH "6911104 - 029T ENILCRIC

U-LAMP T12 34 - 40 1 1 1,2 1,224"-48" T12 20 - 40 1 1 1,2 1,2

1157 - 0521T "69-"061106 - 5321TOH "84-"4211011 - 0721T OH "69-"0611511 - 4721T OHV "84-"4211512 - 53121T OHV "69-"06

PL TWIN-TUBE (4-PIN) 9 - 13 1PL QUAD-TUBE (4-PIN) 13 - 26 1,2TRIPLE-TUBE (4-PIN) 18 - 32 1,2TRIPLE-TUBE (4-PIN) 42 1LONG COMPACT (4-PIN) 18 - 40 1 1 1 1

1155 - 05)NIP-4( TCAPMOC GNOL

Page 4

WIRING DIAGRAMSIMPORTANT NOTES: Before connecting TS/PL connector or wiring unit to refer to INSTALLATION PROCEDUREand IMPORTANT SAFEGUARDS for safety information and mounting procedures.

www.powersentrysafety.com1-888-300-7017

Page 5: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

ONE LAMP INSTANT START SLIMLINE BALLAST

FIGURE C

FIGURE D

TWO LAMP LEAD/LAG INSTANT START SLIMLINE BALLAST

TWO LAMP RAPID START BALLAST

FIGURE B

Page 5www.powersentrysafety.com

1-888-300-7017

Page 6: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

TWO LAMP INSTANT START BALLAST

FIGURE F

THREE LAMP RAPID START BALLAST

FIGURE E

TWO LAMP SERIES LEAD BALLAST

Page 6FIGURE G

www.powersentrysafety.com1-888-300-7017

Page 7: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

ONE LAMP WITHOUT AC BALLAST

FIGURE H

THREE LAMP INSTANT START BALLAST

FIGURE JPage 7

FIGURE I

TWO LAMP WITHOUT AC BALLAST

www.powersentrysafety.com1-888-300-7017

Page 8: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

ONE LAMP CIRCLINE BALLAST

FIGURE K

ONE LAMP INSTANT START BALLAST

FIGURE M

FIGURE LTWO LAMP CIRCLINE BALLAST

Page 8www.powersentrysafety.com

1-888-300-7017

Page 9: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

Page 9

FOUR LAMP INSTANT START ELECTRONIC BALLAST

FIGURE N

ONE FOUR-PIN COMPACT LAMP RAPID START BALLAST (PS1400 ONLY)

TWO LAMP SERIES SEQUENCE INSTANT START BALLAST

FIGURE O

FIGURE P

www.powersentrysafety.com1-888-300-7017

Page 10: FIELD INSTALLABLE FLUORESCENT BATTERY PACK IS …

TWO FOUR-PIN COMPACT LAMP RAPID START BALLAST (PS1400 ONLY)

FIGURE Q

Part no. EMCSA00726REV H

Page 10

PS600 AND PS1400 WARRANTYFIVE-YEAR TOTAL CUSTOMER SATISFACTIONComplete Customer Satisfaction.This unit is guaranteed to perform to our customers’ complete satisfaction for a period of years from date ofinvoice. Our guarantee liabilty extends only to the repair or replacement of the defective part, and no labor charges for corr ection of the defect byrepair or replacement will be paid by Lithonia unless prior written authority has been granted by our Post-Sales Department.

PS300 AND PSQ500 WARRANTYTHREE-YEAR TOTAL CUSTOMER SATISFACTIONComplete Customer Satisfaction.This unit is guaranteed to perform to our customers’ complete satisfaction for a period of three years from date ofinvoice. Our guarantee liabilty extends only to the repair or replacement of the defective part, and no labor charges for corr ection of the defect byrepair or replacement will be paid by Lithonia unless prior written authority has been granted by our Post-Sales Department.

FIGURE R

FOUR LAMP RAPID START BALLAST

www.powersentrysafety.com 1-888-300-7017