R. Wolf ,AT-MEI, CH-1211 Geneva 23 1 FQWG-Fidel meeting 10-07-2008 Fidel Precycles, Database, Model for Field errors R. Wolf

description

Fidel. Precycles, Database, Model for Field errors R. Wolf. Fidel Task List. Precycles Engineering spec. Precycles 2. Precycle data available: CYCLES_ALLOCATION: gives the names of the cycles to be used for each circuit of LHC. - PowerPoint PPT Presentation

Transcript of Fidel

Page 1: Fidel

R.

Wo

lf ,A

T-M

EI,

CH

-12

11

Ge

ne

va 2

3

1FQWG-Fidel meeting 10-07-2008

Fidel

Precycles, Database, Model for Field errors

R. Wolf

Page 2: Fidel

R.

Wo

lf ,A

T-M

EI,

CH

-12

11

Ge

ne

va 2

3

2FQWG-Fidel meeting 10-07-2008

Fidel Task List

Page 3: Fidel

R.

Wo

lf ,A

T-M

EI,

CH

-12

11

Ge

ne

va 2

3

3FQWG-Fidel meeting 10-07-2008

Precycles Engineering spec

Page 4: Fidel

R.

Wo

lf ,A

T-M

EI,

CH

-12

11

Ge

ne

va 2

3

4FQWG-Fidel meeting 10-07-2008

Precycles 2

Precycle data available:

CYCLES_ALLOCATION: gives the names of the cycles to be used for each circuit of LHC.

CYCLES_EXTENDED: gives cycles and precycles (mainly) for magnets with field decay.

CYCLES_SIMPLE: gives cycles for correctors and normal magnets.

Available as Oracle tables on the ‘Fidel’ account on ACCDB (password: Faithful1).

Not complete

Demagnetization cycles (MB, MO?, some warm magnets?)

Synchronization of groups (partly).

General synchronization prescription

Page 5: Fidel

R.

Wo

lf ,A

T-M

EI,

CH

-12

11

Ge

ne

va 2

3

5FQWG-Fidel meeting 10-07-2008

Database issues

Transfer Refparm & Refharm to real database

– Easier access for LSA

– Easy to link field model data to data in other databases, in particular the layout database

– Easier to check formats, uniqueness etc.

First priority. Put copy of Refparm’s in one Oracle table on the Fidel account.

– Add date for the entry

– Add one or more columns for convenience: magnet type

– High priority: To be finished within 2 weeks. (GB/VR).

– Define simple constraints to enforce correct format

– Instruct data responsibles who don’t know Oracle how to read data and how to load data.

Page 6: Fidel

R.

Wo

lf ,A

T-M

EI,

CH

-12

11

Ge

ne

va 2

3

6FQWG-Fidel meeting 10-07-2008

Storage of measurement analysis.

Storage of the analysis to calculate the Fidel model parameters & Other documents

To store on EDMS: AT department/Fidel

– Agreed with E. Delucinge to give her structure (only she or R. Decreuse can change it).

Proposal

– Model_parameter_analysis

• Main dipole

• Main quadrupole

• Insertion magnets

• Separation Dipoles

• Triplets

• MQW

• Warm magnets

• SC_Correctors

– Engineering specifications

Page 7: Fidel

R.

Wo

lf ,A

T-M

EI,

CH

-12

11

Ge

ne

va 2

3

7FQWG-Fidel meeting 10-07-2008

Next Fidel step: Field errors for ‘all’ magnets

We can’t do it perfectly for all magnets.

For next meeting define (RW) what to do.