8
2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality SENKO and R&M components that conform to optical interface standards described in IEC/PN-EN 61754. Connector plugs are terminated on modern assembly line SENKO APC 8000 and verified by means of Data Pixel and EXFO measurement equipment: KONCENTRIK – measurement equipment for ferrule eccentricity verification as well as for eccentricity measurements and tuning of terminated connectors. DAISI / DASI MT – optical interferometer for 1,25 and 2,5 mm connectors and MT / MTRJ endface geometry measurements. IQS 12001 – optical connectors and passive devices insertion loss and return loss computer measurement test set; FOT150 – optical connectors insertion loss and return loss measurement test set kit. All offered connectors are compliant with the requirements for interfaces according to PN-EN 61754 and PN-EN 61755. All cable assemblies are comliant with performance standards series PN-EN 50377 and internal standards of Polish Telecom ZN-05/TPSA-044 for environment of U category according to PN-EN 61753-1 (uncontrolled environment, temperature range from –25 to +70°C, relative humidity 5%-95%). Customised products include connectors for use in environmental category E according to PN-EN 61753-1 (extreme environment, temperature range from –40 to +85°C, relative humidity 0%-98%, humidity condensation, industrial atmosphere). Plugs are offered for three attenuation grades: S-standard, P-premium, M-master. Standard – very high performance plugs providing very good random mate attenuation performance, compliant with IEC and PN-EN standards as well as corporate Polish Telecom standard. Performance of standard grade plugs fulfils requirements of most currently used fiber optic telecommunication systems (SDH, CWDM and CATV). Premium – plugs for most requiring customers, dedicated for use in high-end DWDM systems with high Power levels and in case of tight optical line loss budget. Master – selectioned plugs, dedicated for test and measurement and for extremely high optical Power levels in optical fibers (>30 dBm). Main geometrical parameters of SM PC and APC plugs Parameter Standard Premium Master Radius of curvature PC 2,5/1,25 mm 10–25 mm/ 7–15mm Radius of curvature APC 5 – 12mm Fiber potrusion/undercut (spherical fit) PC and APC +50nm/ -50nm Apex offset for PC and APC plugs < 50um (typical value) 50um 30um APC 8° angle tolerance ± 0,3° ± 0,3° ± 0,2° PC 0° angle tolerance ± 0,2° ± 0,2° ± 0,1° Key positioning tolerance for APC ± 0,5° ± 0,5° ± 0,3° Eccentricity of core of fiber and ferrule Axis for PC and APC plugs 1,5um 1,0um 0,3um Tuning PC and APC YES YES NO

Transcript of FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC...

Page 1: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

2

FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies

Fiber optic patchcords are made of highest quality SENKO and R&M components that conform to optical interface standards described in IEC/PN-EN 61754. Connector plugs are terminated on modern assembly line SENKO APC 8000 and verified by means of Data Pixel and EXFO measurement equipment: KONCENTRIK – measurement equipment for ferrule eccentricity verification as well as for eccentricity measurements and tuning of terminated connectors. DAISI / DASI MT – optical interferometer for 1,25 and 2,5 mm connectors and MT / MTRJ endface geometry measurements. IQS 12001 – optical connectors and passive devices insertion loss and return loss computer measurement test set; FOT150 – optical connectors insertion loss and return loss measurement test set kit. All offered connectors are compliant with the requirements for interfaces according to PN-EN 61754 and PN-EN61755. All cable assemblies are comliant with performance standards series PN-EN 50377 and internal standards ofPolish Telecom ZN-05/TPSA-044 for environment of U category according to PN-EN 61753-1 (uncontrolledenvironment, temperature range from –25 to +70°C, relative humidity 5%-95%). Customised products include connectors for use in environmental category E according to PN-EN 61753-1 (extremeenvironment, temperature range from –40 to +85°C, relative humidity 0%-98%, humidity condensation, industrialatmosphere). Plugs are offered for three attenuation grades: S-standard, P-premium, M-master. Standard – very high performance plugs providing very good random mate attenuation performance, compliant withIEC and PN-EN standards as well as corporate Polish Telecom standard. Performance of standard grade plugs fulfilsrequirements of most currently used fiber optic telecommunication systems (SDH, CWDM and CATV). Premium – plugs for most requiring customers, dedicated for use in high-end DWDM systems with high Power levelsand in case of tight optical line loss budget. Master – selectioned plugs, dedicated for test and measurement and for extremely high optical Power levels inoptical fibers (>30 dBm). Main geometrical parameters of SM PC and APC plugs

Parameter Standard Premium Master Radius of curvature PC 2,5/1,25 mm 10–25 mm/ 7–15mm

Radius of curvature APC 5 – 12mm Fiber potrusion/undercut

(spherical fit) PC and APC +50nm/ -50nm

Apex offset for PC and APC plugs < 50um (typical value) ≤ 50um ≤ 30um

APC 8° angle tolerance ± 0,3° ± 0,3° ± 0,2° PC 0° angle tolerance ± 0,2° ± 0,2° ± 0,1°

Key positioning tolerance for APC ± 0,5° ± 0,5° ± 0,3° Eccentricity of core of fiber and ferrule

Axis for PC and APC plugs ≤ 1,5um ≤ 1,0um ≤ 0,3um

Tuning PC and APC YES YES NO

Page 2: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

3

Main optical parameters Connector type Random mating

Insertion loss (PN-EN 61300-3-34),

average, IL, dB

Insertion loss against reference plug

(PN-EN 61300-3-4), Maximum value,

IL, dB

Return loss of random mating

(PN-EN 61300-3-6), Minimum value,

ORL, dB SM-PC FC/PC

SC/PC E2000/PC

MU/PC ST/PC LC/PC

grade S ≤ 0,20 (99%≤ 0,5)

grade P ≤ 0,12 (97%≤ 0,25)

grade M ≤ 0,10 (97%≤ 0,15)

grade S - 0,4 grade P - 0,25 grade M - 0,15

grade S – 45 grade P - 45 grade M – 50

MTRJ < 0,30 (95%< 0,60) 0,75 35

SM-APC

FC/APC SC/APC

E2000/APC

grade S ≤ 0,20 (99%≤ 0,5)

grade P ≤ 0,12 (97%≤ 0,25)

grade M ≤ 0,10 (97%≤ 0,15)

grade S - 0,4 grade P - 0,25 grade M - 0,15

grade S – 60 grade P – 60 grade M - 65

SM MT ANGLE

MPO MTP

≤ 0,35 max 0,7

No reference plug specification 55

MM ST/PC FC/PC SC/PC LC/PC MU/PC

≤0,35

(95% ≤0,5) max 0,75

No reference plug specification 26

MTRJ

≤0,50 (95% ≤ 0,75)

No reference plug specification 26

MM MT FLAT

MPO MTP

≤ 0,50 max 1,0

No reference plug specification 26

Each plug is labelled with unique serial number together with manufacturing date (mm/yy) and has insertion loss and return loss test report (against REF reference plug). Each test report is unambiguously connected with a plug. Premium and Master grade plugs are accompanied by eccentricity test reports and endface geometry test reports.

0102030405060708090

100

Matingsnumber

IL, dB

Random mating SC/APC StandardPN- EN 61300-3-34

average: 0,159 dBstd. deviation: 0,046 dB

0102030405060708090

100

Matings number

IL, dB

Random mating SC/APC PremiumPN- EN 61300-3-34

average: 0,068 dBstd. deviation: 0,044 dB

Page 3: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

4

Marking

Example of order J – SX – SMB2 – SCP - SCP - U – 24 – 100 Patchcord simplex terminated with plugs SM SC/PC Premium, fiber SM B2 according to PN-EN 60793-2-50, environment cat. U, reinforced cable of diam. 2,4 mm and of length 10 m. P – SX - SMF28 – E2AP –U - 09 – 20 Pigtail simplex terminated with plug SM E2000/APC Premium, fiber SMF28, environment cat. U, buffer fiber 0,9 mm of length 2 m.

Page 4: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

5

FIBER OPTIC CONNECTORS AND ADAPTERS SPECIFICATION SC connectors - PN-EN 61754-4 • SC/PC SM plugs • SC/APC SM plugs • SC/PC MM plugs • SC/PC duplex SM and MM plugs • SC/APC adapters • SC simplex SM and MM adapters • SC „small flange” adapters • SC duplex SM and MM adapters • Plugs terminated on reinforced cables 3/2,4/2 mm

and buffer fibres 0,9 mm

E2000 connectors – PN-EN 61754-15

• E2000/PC SM plugs • E2000/APC SM plugs • E2000/PC SM adapters • E2000/APC SM adapters • E-2000 „small flange” adapters • Plugs terminated on 3/2,4/2 mm cables and buffer fiber 0,9

mm FC connectors - PN-EN 61754-13 • FC/PC SM plugs • FC/APC SM plugs • FC/PC MM plugs • FC DHM adapters • FC/APC tight key adapters • Plugs terminated on reinforced cables 3/2,4/2 mm and

buffer fiber 0,9 mm ST connectors - PN-EN 61754-3 • ST/PC SM plugs • ST/PC MM plugs • ST SM i MM adapters • Plugs terminated on cables 3/2,4 mm and buffer fiber 0,9

mm

Page 5: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

LC connec

• LC• LC• LC• LC• Pl

bu MU conne

• M• M• M• Pl

bu MTRJ con

• M• M• M• M• M• Pl

MPO/MTP

• M• M• M• Pl• In

Hybrid ada

• FC• FC• FC• SC• SC• SC• SC• SC• FD• ES

ctors - PN-EN

C/PC SM plugC/PC MM plugC/PC duplex SC duplex SM ilugs terminateuffer fiber 0,9

ctors - PN-E

U/PC SM plugU/PC SM DupU duplex SM lugs terminateuffer fiber 0,9

nectors – PN

TRJ SM “maTRJ SM „femTRJ MM “maTRJ MM „femTRJ adapterslugs terminate

connectors

TP and MPO TP and MPO TP/MPO adaplugs terminatestallation of fa

apters

C/PC – SC/PCC/PC – ST/PCC/PC – E2000C/PC – ST/PCC/PC – E2000C/APC – FC/AC/APC – E200C/PC – ST/PCDDI – ST/PC SCON – ST/P

N 61754-20

gs gs SM i MM plugs MM adaptersed on cablesmm

EN 61754-6

gs plexks plugs adapters ed on cablesmm

N-EN 61754-1

le” plugs male” plugs ale” plugs male” plugs s, mounting hoed on duplex c

– PN-EN 617

12 fibers SM 12 fibers MMpters ed on reinforcean-out 12 fibre

C C 0/PC C 0/PC APC 00/APC C Duplex Duplex

PC Duplex

s s 3,0/2,4/2,0/1

3,0/2,4/2,0/1

8

ole SC cables 1,6mm

754-7

(angle) plugs (flat) plugs

ed ribbon cables SM and MM

,6 mm and

,6 mm and

les M

6

Page 6: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

7

FIBER OPTIC ATTENUATORS ATC Fix attenuators made of doped fiber, optimized for 1310, 1550, 1310/1550 nm and optical bands C and L.

• Attenuation range: 1 - 10 dB every 1 dB, 12, 15, 20, 25dB;

• Tolerance: 1...5 dB ± 0,5dB, 6...25dB ± 10%; • Operating wavelength 1310 and 1550nm: ±10nm; • ORL: PC >50dB, APC>65dB; • Max optical power >30dBm (1W); • all connector types; • operating temperature range: -40...+75°C •

ATS

Fused attenuators on reinforced cables.

• Attenuation range: 3...20dB; • Tolerance: 3...5dB± 0,5dB, 6...20 dB ± 10%; • Operating wavelength: 1310/1550±20nm; • all connector styles; • any length; • operating temperature range: -25...+70°C

TRM terminators Plug terminators for back-reflection suppression.

• ORL: PC >50dB, APC>65dB; • Max. optical power >30dBm (1W); • all main connector styles; • operating temperature range: -40...+75°C

Example of order ATS-10-SM-SCAP-E2AP-U-24- 5 Fused attenuator 10dB, SM, terminated with SM SC/APC and E2000/APC Premium plugs, environment cat. U, made on reinforced simplex cable of diam. 2,4 mm and length 5 m.

Page 7: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

8

PRE-TERMINATED CABLES AND FIBRES MPO/MTP indoor cables

Indoor cables with MPO and MTP connectors • patchcords SM, female, angle - 12 ribbon fibers; • hybrid patchcordsy „fan out” SM , male, angle –

SC/E2A/LC/ST, 12 fibers; • patchcords MM , female, flat - 12 ribbon fibers; • hybrid patchcords „fan out” MM , male, flat – SC/ST/LC,

12 fibers; • MPO adapters; • fan-outs optimal installation in adapted patch panels

and distribution boxes; • environment cat. C according to PN-EN 61753-1

(controlled environment) Indoor cables (multi-cables) Pre-terminated indoor cables.

• cables of 2-12 buffer fibres 0,9mm SM and MM; • pigtails 0,9mm or in 2mm jacket with simplex

connectors; • environment cat. C according to PN-EN 61753-1

(controlled environment) Outdoor cables – tactical Pre-terminated outoor cables.

• cables with poliuretan coating (PUR) reinforced by aramid, diam. 6 mm;

• 2-4 fibers SM i MM, buffer 0,9mm; • pigtaile in 2mm jacket with simplex connectors; • SM and MM LC duplex cables; • environment cat. E according to PN-EN 61753-1

(extreme environment) Outdoor trumpet cables, gelled Pre-terminated outdoor cables

• cables of 2-12 fibres SM and MM, coating 0,25mm • terminated with threaded head for CATV equipment

(5/8”thread); • pigtails buffer 0,9mm or reinforced cable of 2mm; • environment cat. U according to PN-EN 61753-1

(uncontrolled environment)

Page 8: FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies · 2009-07-03 · 2 FIBER OPTIC INTERCONNECTING COMPONENTS Cable assemblies Fiber optic patchcords are made of highest quality

9

SWR – box optical network simulators

F

Boxes with optical fiber for measurement with OTDR reflectometer (dead-zone suppression), dedicated to laboaratory tests B&R and education.

• SM and MM optical fibers; • Total fibers length up to 4 km; • pigtaile of length up to 5m; • terminated with any connectors; • durable and aesthetic housing made of polycarbonate

Optical network simulators

• OPD/6U – patch panel up to 40km of fiber • OPD/3U – patch panel up to 10 km of fiber • reels with z optical fiber SMF28e of length up to 20km,

terminated with pigtails with any connectors.

Example of order J-12-SM–MPOAF-MPOAF-C-RC-50 Indoor reinforced ribbon cable of 12 fibers SM with connectors MPO angle, female, environment cat. C according to PN-EN 61753-1, length 5,0m. F-12-SM-MPOAM-SCP-C-09-20 Fan-out, 12 fibers SM, with connectors MPO angle, male and connecotrs SC/PC grade premium, pigtails on buffer fiber 0,9mm of length 2 m, environment cat. C according to PN-EN 61753-1 SWR - SMF28e - 1000- FC – SCA - C - 20 - 50 Box with fiber SMF28e of length 1000m, environment cat. C according to PN-EN 61753-1, pigtailes FC/PC and SC/APC, cable 2mm of length 5m