15
48 LAN Cabling Systems www.dintek.com.tw Fiber Optic Cabling System DINTEK 4C 23kg/ km 4.8mm 1000N/ 225lbs 48mm 6C 37kg/ km 6.5mm 1000N/ 225lbs 65mm 8C 41kg/ km 6.8mm 1400N/ 315lbs 68mm 12C 47kg/ km 7.0mm 1800N/ 405lbs 70mm In-Door Fiber Optic Cable: Standard 04, 06, 08, 12C Extremely flexible, tight buffer cable design ATM, FDDI, Fiber channel cable performance guarantee LSOH jacket Mechanical Specification: Storage Temperature: -40°C to 70°C Operating Temperature: -40°C to 70°C Max. attenuation(dB/km) Min. bandwidth(MHz/km) Item Fiber Count Weight O.D(mm) Tensile Load Bending Radius In-Door Fiber Optic Cable 2101-02001 2101-02002 2101-02003 2101-02004 2101-03002 2101-03003 2101-03004 2101-03005 Flame rating:OFNR Application: LAN Drop ceiling Internal- building Backbone premise pathways Transmission Performace: 2km/reel 2km/reel 2km/reel 2km/reel 2km/reel 2km/reel 2km/reel 2km/reel Single-mode 9/125um cables are available upon request. Single-mode 9/125um(1310/1550nm) Multi-mode 50/125um(850/1300nm) Multi-mode 62.5/125um(850/1300nm) 0.7/0.7 - / - 3.5/2.0 500/500 3.5/1.0 200/500 P/N Description Std Pkg Qty 4C, Multi-Mode, 50/ 125um 6C, Multi-Mode, 50/ 125um 8C, Multi-Mode, 50/ 125um 12C, Multi-Mode, 50/ 125um 4C, Multi-Mode, 62.5/ 125um 6C, Multi-Mode, 62.5/ 125um 8C, Multi-Mode, 62.5/ 125um 12C, Multi-Mode, 62.5/ 125um

Transcript of Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling...

Page 1: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

48

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEK

4C 23kg/ km 4.8mm 1000N/ 225lbs 48mm

6C 37kg/ km 6.5mm 1000N/ 225lbs 65mm

8C 41kg/ km 6.8mm 1400N/ 315lbs 68mm

12C 47kg/ km 7.0mm 1800N/ 405lbs 70mm

In-Door Fiber Optic Cable: Standard 04, 06, 08, 12C

Extremely flexible, tight buffer cable design

ATM, FDDI, Fiber channel cable performance guarantee

LSOH jacket

Mechanical Specification: Storage Temperature: -40°C to 70°C

Operating Temperature: -40°C to 70°C

Max. attenuation(dB/km)

Min. bandwidth(MHz/km)

Item

Fiber Count Weight O.D(mm) Tensile Load Bending Radius

In-Door Fiber Optic Cable

2101-02001

2101-02002

2101-02003

2101-02004

2101-03002

2101-03003

2101-03004

2101-03005

Flame rating:OFNR

Application: LAN

Drop ceiling

Internal- building

Backbone premise pathways

Transmission Performace:

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

Single-mode 9/125um cables are available upon request.

Single-mode9/125um(1310/1550nm)

Multi-mode50/125um(850/1300nm)

Multi-mode62.5/125um(850/1300nm)

0.7/0.7

- / -

3.5/2.0

500/500

3.5/1.0

200/500

P/N Description Std Pkg Qty

4C, Multi-Mode, 50/ 125um

6C, Multi-Mode, 50/ 125um

8C, Multi-Mode, 50/ 125um

12C, Multi-Mode, 50/ 125um

4C, Multi-Mode, 62.5/ 125um

6C, Multi-Mode, 62.5/ 125um

8C, Multi-Mode, 62.5/ 125um

12C, Multi-Mode, 62.5/ 125um

Page 2: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

49www.dintek.com.tw

LAN Cabling Systems

Fiber Optic Cabling System DINTEKIndoor/Outdoor Fiber Optic Cable

Feature: Standard 04, 06, 08, 12C

Central code tube design

Color-coded fiber for easy identification

LSOH for outside jacket material

Application: Drop ceiling

Internal- building

Outdoor back bone for Duct applications

2102-02002

2102-02003

2102-02001

2102-02004

2102-03001

2102-03002

2102-03004

2102-03003

Mechanical Specification: Storage Temperature: -40°C to +70°C

Operating Temperature: -30°C to +70°C

P/N

Single Mode 9/ 125um cables are available upon request

Fiber Count

Transmission Performace:

Max. attenuation(dB/km)

Min. bandwidth(MHz/km)

Item Single-mode

9/125um(1310/1550nm) Multi-mode

50/125um(850/1300nm) Multi-mode

62.5/125um(850/1300nm)

0.5/0.4

- / -

3.5/2.0

500/500

3.5/1.0

200/500

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

Weight O.D(mm) Tensile Load Bending Radius

04-12 65kg/km 8.7±0.4 2700N/603lbs 20 x O.D during installation

Description Std Pkg Qty

4C, Multi-Mode, 50/ 125um,LSOH

6C, Multi-Mode, 50/ 125um,LSOH

8C, Multi-Mode, 50/ 125um,LSOH

12C, Multi-Mode, 50/ 125um,LSOH

4C, Multi-Mode, 62.5/ 125um,LSOH

6C, Multi-Mode, 62.5/ 125um,LSOH

8C, Multi-Mode, 62.5/ 125um,LSOH

12C, Multi-Mode, 62.5/ 125um,LSOH

Fiber Count Weight O.D(mm) Tensile Load Bending Radius

Page 3: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

50

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEK

Feature: Central code tube design

Color-coded fiber for easy identification

during installation

4 to 12 fiber available

MDPE outer jacket

Conform with IEC 793, EIA/TIA-492

Mechanical Specification: Storage Temperature: -40°C to +70°C

Operating Temperature: -40°C to +70°C

Out-Door Dielectric Fiber Cable

Single Mode 9/ 125um cables are available upon request

Transmission Performace:

Application: Outdoor back bone for aerial and duct applications

Indoor back bone for open tray and conduit applications

Max. attenuation(dB/km)

Min. bandwidth(MHz/km)

Item Single-mode

9/125um(1310/1550nm) Multi-mode

50/125um(850/1300nm) Multi-mode

62.5/125um(850/1300nm)

0.5/0.4

- / -

3.5/2.0

400/400

Fiber Count Weight O.D(mm) Tensile Load Bending Radius

04-12 60kg/km 8.7±0.4 2700N/603lbs 20 x O.D during installation

P/N Description Std Pkg Qty

2103-02001

2103-02002

2103-02003

2103-02004

2103-03007

2103-03004

2103-03009

2103-03010

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

4C, Multi-Mode, 50/ 125um

6C, Multi-Mode, 50/ 125um

8C, Multi-Mode, 50/ 125um

12C, Multi-Mode, 50/ 125um

4C, Multi-Mode, 62.5/ 125um

6C, Multi-Mode, 62.5/ 125um

8C, Multi-Mode, 62.5/ 125um

12C, Multi-Mode, 62.5/ 125um

3.5/1.0

200/500

Aramid yarns

Water blocking type

MDPE jacket

Core tube

3.5/1.0

200/500

Page 4: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

51www.dintek.com.tw

LAN Cabling Systems

Fiber Optic Cabling System DINTEK

Feature: Central code tube design

Color-coded fiber for easy identification

during installation

4 to 12 fiber available

MDPE outer jacket

Conform with IEC 793, EIA/TIA-492

Mechanical Specification: Storage Temperature: -40°C to +75°C

Operating Temperature: -40°C to +70°C

Installation Temperature: -30°C to +60°C

Out-Door Armor Fiber Optic Cable

Single Mode 9/ 125um cables are available upon request

Transmission Performace:

Application: Outdoor back bone for aerial and duct applications

Indoor back bone for open tray and conduit applications

Max. attenuation(dB/km)

Min. bandwidth(MHz/km)

Item Single-mode

9/125um(1310/1550nm) Multi-mode

50/125um(850/1300nm) Multi-mode

62.5/125um(850/1300nm)

0.5/0.4

- / -

3.5/2.0

500/500

Fiber Count Weight O.D(mm) Tensile Load Bending Radius

04-12 155kg/km 11.6±0.4 2700N/603lbs 20 x O.D during installation

P/N Description Std Pkg Qty

2103-02005

2103-02006

2103-02007

2103-02008

2103-03012

2103-03001

2103-03002

2103-03013

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

2km/reel

4C, Multi-Mode, 50/ 125um

6C, Multi-Mode, 50/ 125um

8C, Multi-Mode, 50/ 125um

12C, Multi-Mode, 50/ 125um

4C, Multi-Mode, 62.5/ 125um

6C, Multi-Mode, 62.5/ 125um

8C, Multi-Mode, 62.5/ 125um

12C, Multi-Mode, 62.5/ 125um

3.5/1.0

200/500

3.5/1.0

200/500

Page 5: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

52

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEK

Standard ST/ST, ST/SC and SC/SC fiber optic patch cables

Simplex and Duplex type

Fiber Optic Patch Cord

Fully tested prior to shipment

Customized length also available.

LC. MT-RJ and FC is also available

Please contact us for any customized requirements.

P/N

300

240

200

1000

300

240

200

1000

300

240

200

Description Std Ctn Qty

2104-01006

2104-01008

2104-01009

ST/ST, duplex,,2M, 62.5/125um

ST/ST, duplex,,3M, 62.5/125um

ST/ST, duplex,,5M, 62.5/125um

2105-01003 STpigtail,1M, 62.5/125um

2104-03006

2104-03008

2104-03009

SC/SC, duplex,,2M, 62.5/125um

SC/SC, duplex,,3M, 62.5/125um

SC/SC, duplex,,5M, 62.5/125um

2105-02001 SCpigtail,1M, 62.5/125um

2104-02003

2104-02004

2104-02005

SC/ST, duplex,,2M, 62.5/125um

SC/ST, duplex,,3M, 62.5/125um

SC/ST, duplex,,5M, 62.5/125um

2104-06001 MTRJ/MTRJ, duplex, 5M, 62.5/125um

2104-07003 LC/LC, duplex, 3M, 9/125um

2104-05002 FC/FC, simplex, 5M, 62.5/125um

2104-04011

2104-04010

2104-04002

SC/FC,duplex, 2M, 62.5/125um

SC/FC,duplex, 3M, 62.5/125um

SC/FC,duplex, 5M, 62.5/125um

300

240

200

200

240

200

Page 6: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

53www.dintek.com.tw

LAN Cabling Systems

Fiber Optic Cabling System DINTEK

Accepts up to 12 ports in either ST or SC configuration

ST and SC connectors are available separately to load into the enclosure

Wall Mount Fiber Optic Enclosure

Termination panel that slides out for easy access

Splice tray, sleeves and ST/SC connectors are available separately to load into panel

Can be mounted on 19” EIA racks

19” Fiber Optic Rack Mount Enclosure

P/N Description

2201-24014

2201-24015

2202-1200112 ports ST coupler wall enclosure

include 2 pieces of 6 port ST panel

19” 1U space, 24 ports ST coupler rack mount enclosure with sliding tray, includes 2 pieces of 12 port ST panel

19” 1U space, 12 ports duplex SC rack mount enclosure with sliding tray, includes 2 pieces of 6 port duplex SC panel

2202-12007

2202-12006

Wall mount fiber enclosure .6 port dual SC type. Equipped with splice tray, holder and snap-in panel accordingly

Wall mount fiber enclosure. 12 port ST type. Equipped with splice tray, holder and snap-in panel accordingly

10

10

19” 1U. space, 12 port duplex SC rack mount enclosure,includes 2 pieces of 6 ports duplex SC panel

19” 1U. space, 24 port ST coupler rack mount enclosure,includes 2 pieces of 12 ports ST panel

2201-24013

2201-24012

12 ports of splice tray

12 ports of splicing holder

Fusion splice protector sleeve

2204-02001

2205-02002

2206-00001

6

6

19” 2U space, 48 ports ST coupler rack mount enclosure with sliding tray, includes 8 pieces of 6 port ST panel

2201-48001 4

10

10

25

10

10

P/N Description Std Pkg Qty

10

P/N Description Std Pkg Qty

Page 7: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

54

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEKFiber Optic Connectors

2107-01003

P/N Description Std Pkg Qty Std Ctn Qty

ST coupling receptacle 50 500

2107-03001

2107-03002

SC duplex type coupling receptacle

SC simplex type coupling receptacle

50

50

500

500

2107-05001

2107-05004

FC coupling receptacle,square flange type.

FC coupling receptacle MM,round flange (D-type) type.

50

50

500

500

2106-01002

2106-01003

2106-01004

ST connector, multi-mode,for cable O.D:3.0mm

ST connector, multi-mode,for cable O.D:0.9mm

ST connector, single-mode,for cable O.D:3.0mm

50

50

50

500

500

500

2106-02001

2106-02002

SC connector, single-mode, for cable O.D.:3.0mm

SC connector, multi-mode, for cable O.D.:3.0mm

50

50

500

500

2106-03001

2106-03002

2106-03003

FC connector, single-mode,for cable O.D:3.0mm

FC connector, multi-mode,for cable O.D:3.0mm

FC connector, multi-mode,for cable O.D:0.9mm

50

50

50

500

500

500

Performace specifications: Insertion Loss (dB): <=0.20 (single-mode), <=0.20 (multi-mode)

Return Loss (dB): >=55 (single-mode), >=40 (multi-mode)

For connecting fiber links, choose from simplex or duplex, multi-mode or single-mode and so on.

Customized length also available.

Page 8: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

55www.dintek.com.tw

LAN Cabling Systems

Fiber Optic Cabling System DINTEK

2609-02005

19” Rack-Mount Media Converter Chassis

Key Features: 19-inch standard chassis with 2U height

Supports up to 19 line card converters

2 power supplies, AC or DC interchangeable

1 cooling fan

1 display card indicating the status of powers and fan

FCC Class A, CE Mark

Technical Specification: Mechanical

Standards: 19-inch chassis

Height :2U

18 standard slots for media converter

line cards and 1 dual-function slot for

a media converter line card or an LED

diagnostic card

19” rack mount chassis for media conversion

modules with redundant power

P/N Description Std Pkg Qty

1

Overview:The 19-inch rack mount chassis is designed to accommodate 18 or 19 line cards of various types of media converters for easy operation and management. The compact 2U height saves the space of central offices. The redundant power system can be DC or AC to meet your different needs.

Physical Characteristics

Applicable line cards: CS-110 line card series

Operating Temperature: 0°C to 70°C

Operating Humidity: 10% to 90% (Non-condensing)

AC Power Supply Input: 100~250VAC 50~60Hz,

Output: 12VDC 8.5A

DC Power Supply Input: 18~56VDC,

Output: 12VDC 8.5A

1000Base-SX/LX Fiber

100Base-Fx Fiber100Base-Fx Fiber

L2 Switch Hub

19” Rack Chassis

Fiber Optic Cable

Page 9: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

56

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEK10/100M TP to 100Base-FX Converter

Key Features:Complies with IEEE 802.3 10Base-T, IEEE802.3u 100Base-TX and 100Base-FX standards

Fiber connectivity up to 2km for multimode fiber, 60km for single-mode fiber

Optional SC, FC, ST, LC or Bi-directional SC(single mode only) fiber connectors

Full-Duplex, Half-Duplex, or Auto-Negotiation

Supports packet length up to 1600 bytes

The other simplex single-mode types and US power plug are available upon request.

Technical Specifications: Standards IEEE 802.3 10Base-T, 802.3u 100Base-TX and 100Base-FX

Protocol CSMA/CD

Cable:

Cat.5 UTP Cable: support distance up to 100M Fiber: 850/1300nm multi-mode support distance up to 2km

1310/1550nm single-mode support distance up to 60km

Connector: RJ-45: 10/100 Mbps auto-negotiation ST/SC/LC: 100 Mbps

External Power Supply for Stand-alone unit:

Input rating: 100 ~ 240 VAC, 50-60 Hz Output rating: 5 VDC, 1A

Operating temperature: 0 to 70°C

Humidity: 10% to 90%

Dimensions: Stand-alone unit:21.4(H) x 63.6(W) x102(D)mm Slide-in card:22.2(H) x 87(W) x 113.5(D)mm

10/100Base-TX/FX. RJ-45/SC. Duplex multi-mode. 2km. Slide-in card

P/N Description Std Pkg Qty

10/100Base-TX/FX media converter provides you with various optional connectors for your fiber optic cable and RJ-45 ports (straight through and crossover) for your 10/100Base-TX cable connection. Eight LED indicators signal the detailed operating status of the converter for easier fault identification. 10/100Base-TX/FX is provided in two package forms.The stand-alone unit is powered by external adaptor, while the slide-in card is used in 19-inch rack mount chassis.

Overview:

10/100Base-TX/FX. RJ-45/SC. Duplex multi-mode. 2km. Stand-alone unit

10/100Base-TX/FX. RJ-45/ST. Duplex multi-mode. 2km. Stand-alone unit

10/100Base-TX/FX. RJ-45/ST. Duplex multi-mode. 2km. Slide-in card

10/100Base-TX/FX. RJ-45/SC. Duplex single-mode. 30km. Stand-alone unit

10/100Base-TX/FX. RJ-45/SC. Duplex single-mode. 30km. Slide-in card

10/100Base-TX/FX. RJ-45/LC. Duplex single-mode. 30km. Stand-alone unit

10/100Base-TX/FX. RJ-45/LC. Duplex single-mode. 30km. Slide-in card

10/100Base-TX/FX. RJ-45/SC. Duplex single-mode. 60km. Slide-in card

10/100Base-TX/FX. RJ-45/SC. Duplex single-mode. 60km. Stand-alone unit

10/100Base-TX/FX. RJ-45/LC. Duplex single-mode. 60km. Stand-alone unit

10/100Base-TX/FX. RJ-45/LC. Duplex single-mode. 60km. Slide-in card

2610-01005

2610-01005C

2610-02011

2610-02011C

2610-05002

2610-05002C

2610-02010

2610-02010C

2610-05003

2610-05003C

2610-02012

2610-02012C

1

1

1

1

1

1

1

1

1

1

1

1

Page 10: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

57www.dintek.com.tw

LAN Cabling Systems

Fiber Optic Cabling System DINTEK10/100/1000Base-T to 1000Base-SX/LX ConverterOverview:10/100/1000Base-TX/FX media converter provides you with optional connectors for your fiber optic cable and RJ-45 ports (straight through and crossover) for your 1000Base-T cable connection. The media conversion is accomplished without any complex setting. LED indicators signal the detailed operating status of the converter for easier fault identification. 10/100/1000Base-TX/FX is provided in two package forms. The stand-alone unit is powered by external adaptor, while the slide-in card is used in 19-inch rack mount chassis.

Complies with IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX/FX, IEEE 802.3ab 1000Base-T and IEEE 802.3z 1000Base-SX/LX Fiber connectivity up to 550m for multi-mode fiber, 60km for single-mode fiber One auto-MDIX RJ-45 connector interface Full-Duplex, Half-Duplex, or Auto-Negotiation 8 diagnostic LEDs (power, duplex/collision, TP 1000 Mbps, TP 100 Mbps, TP 10 Mbps, fiber link, transmitting, receiving) Provides fault propagation function for easy cable fault detection

Key Features:

Technical Specifications: Standards IEEE 802.3 10Base-T, 802.3u 100Base-TX/FX, 802.3ab 1000Base-T and 802.3z 1000Base-SX/LX

Protocol CSMA/CD

Cable: Cat.5 UTP Cable: support distance up to 100M Fiber: Up to 550 m with 50/125 or 62.5/125 μm multimode fiber Up to 60 km with 9/125 μm single-mode fiber

Connector: RJ-45: 10/100/1000 Mbps auto-negotiation SC, FC, ST, LC or Bi-directional SC (single mode only): 1000 Mbps

External Power Supply for Stand-alone unit:

Input rating: 100 ~ 240 VAC, 50-60 Hz Output rating: 5 VDC, 1A

Operating temperature: 0 to 70°C

Humidity: 10% to 90%

Dimensions: Stand-alone unit:21.4(H) x 63.6(W) x102(D)mm Slide-in card:22.2(H) x 87(W) x 113.5(D)mm

P/N Description Std Pkg Qty

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 10km. Slide-in card

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 10km. Stand-alone unit

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex MM. 550m. Stand-alone unit

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex MM. 550m. Slide-in card

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 40km. Stand-alone unit

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 40km. Slide-in card

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 20km. Stand-alone unit

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 20km. Slide-in card

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 60km. Stand-alone unit

10/100/1000Base-TX/1000Base-FX. RJ-45/SC. Duplex SM. 60km. Slide-in card

2615-02001

2615-02001C

2615-02004

2615-02004C

2615-02005

2615-02005C

2615-02006

2615-02006C

2615-02007

2615-02007C

1

1

1

1

1

1

1

1

1

1

The other simplex single-mode types and US power plug are available upon request.

Page 11: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

58

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEK1000Base-T to 1000Base-SX/LX Media Converter

1000Base-TX/FX media converter provides you with optional connectors for your fiber optic cable and

RJ-45 ports (straight through and crossover) for your 1000Base-T cable connection. LED indicators signal the detailed operating status of the converter for easier fault identification. 1000Base-TX/FX is provided in two package forms. The stand-alone unit is powered by external adaptor,

while the slide-in card is used in 19-inch rack mount chassis.

Overview:

Technical Specifications: IEEE Compliance 802.3z 1000Base-SX/LX, 802.3ab 1000Base-T

Cable:

Cat.5 UTP Cable: support distance up to 100M Fiber: Up to 550 m with 50/125 or 62.5/125 μm multimode fiber Up to 60 km with 9/125 μm single-mode fiber

Connector: RJ-45: 1000Base-T supported SC: 1000Base-SX/LX supported

External Power Supply for Stand-alone unit:

Input rating: 100 ~ 240 VAC, 50-60 Hz Output rating: 5 VDC, 1A

Operating temperature: 0 to 70°C

Humidity: 10% to 90%

Dimensions: Stand-alone unit:21.4(H) x 63.6(W) x102(D)mm Slide-in card:22.2(H) x 87(W) x 113.5(D)mm

Electromagnetic Compliance: FCC Class A, CE Class A

Key Features:Easy installation without adjustment and configuration setting

Support of full duplex transmission

Cut-through operation mode for very low latency

6 diagnostic LEDs (Power, Full Duplex /Collision, Fiber Link, Fiber Receiving, TPLink and Fiber Transmitting)

Optional stand-alone unit and slide-in card

The other simplex single-mode types and US power plug are available upon request.

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 10km. Slide-in card

P/N Description Std Pkg Qty

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 10km. Stand-alone unit

1000Base-TX/FX. RJ-45/SC. Duplex multi-mode. 550m. Stand-alone unit

1000Base-TX/FX. RJ-45/SC. Duplex multi-mode. 550m. Slide-in card

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 40km. Stand-alone unit

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 40km. Slide-in card

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 20km. Stand-alone unit

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 20km. Slide-in card

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 60km. Stand-alone unit

1000Base-TX/FX. RJ-45/SC. Duplex single-mode. 60km. Slide-in card

2611-02004

2611-02004C

2611-02005

2611-02005C

2611-02006

2611-02006C

2611-02007

2611-02007C

2611-02008

2611-02008C

1

1

1

1

1

1

1

1

1

1

Page 12: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

59www.dintek.com.tw

LAN Cabling Systems

Fiber Optic Cabling System DINTEKGigabit Ethernet Multi-mode to Single-mode ConverterKey Features: Supports 1000Base-SX/LX multi-mode to single-mode conversion

Good for application to extend network distances up to 10Km

Standalone or compositioh applications

Technical Specifications: Multi-mode 1000SX----Single-mode 1000LX

SC:220m 850nm ----SC: 10Km 1310nm

Fiber cable:

50/125, 62.5/125, or 100/140um multi-mode

8.3/125, 8.7/125, or 9/125um single-mode

Data Transfer Rate: 2,000Mbps at full-duplex mode

LED Indicators:

power, SD (signal detect ) for multi/single mode fiber port

Power requirement: 1A@5VDC

Ambient temperature: 0 to 50°C

Humidity: 5% to 90%

Dimensions: 26.2(H) x 70.3(W) x 94(D)mm

FCC Part 15 Class A, CE Mark & UL

2612-01001

2612-01002

Gigabit SX multi-mode to LX single-

mode. SC/SC. US power plug.

10KM, 100~240VAC

Gigabit SX multi-mode to LX single-

mode. SC/SC. UK power plug.

10KM, 100~240VAC

P/N Description Std Pkg Qty

1

1

Page 13: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

60

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEK6-Port 10/100Base-TX + 2 10/100Base SFT ports Switch

Auto MDI-MDIX for all Copper ports Supports auto-polarity for 10 Mbps Supports 802.3x Flow Control for Full-Duplex mode and Back Pressure for Half-Duplex mode Supports 1k MAC addresses 512k bits packet buffer memory Supports Smart Cable Analysis (SCA) for easy cable fault diagnosis Supports Aging Timer of queuing packets Supports the options of filtering or forwarding special addresses Supports port base VLAN groups Supports power saving mode for 10 Mbps operation Supports Link Down Power Saving (LDPS) mode Supports MLT3 detection for switching from 10 Mbps to 100 Mbps Supports Broadcast Storm protection Supports Aggressive Back-off mode to get higher priority in a collision event Supports higher priority for Fiber (SFP) ports Supports two-level Class of Service (CoS) Supports optional maximum packet size of 1536 or 1552 bytes 3 diagnostic LED’s for each port (Link, Speed and Duplex)

Overview:

IEEE Compliance: 802.3 Ethernet, 802.3u Fast Ethernet, 802.3x Flow Control

Switch Fabric:1.6 Gbps

Forwarding Rate:14880 pps at 10 Mbps, 148800 pps at 100 Mbps

MAC Address Table Size:1k

Packet Buffer Memory:512k bits

Copper Interface:6 10Base-T/100Base-TX supported RJ-45 ports

SFP Interface:2 100Base-FX supported ports

LED Indicators:Power, Link (per port), Speed (per port), Duplex (per port)

Control Interface:10 DIP switches, 1 RESET button switch

Power Supply:Input: 100 ~ 240 VAC 50 ~ 60Hz, Output: 5VDC, 2A

Dimensions:107.4 mm x 173.2 mm x 27.1 mm

Weight:500g

Operating Temperature:0 ~ 50ºC

Operating Humidity:10% ~ 90% RH

Electromagnetic Compliance:FCC Class B, CE Class B 2/4

Key Features:

Technical Specifications:

The fast Ethernet switch equipped with 6 Copper and 2 SFP ports, which can be promptly set by DIP switches.2 Fiber (SFP) ports are for the connection with distant Intranet or FTTH service provider. It also can be deployed as a media converter with Copper to Fiber or Single-mode to Multimode applications. It is fully compliant with IEEE802.3, IEEE802.3u, and IEEE802.3x standards.

Page 14: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

61www.dintek.com.tw

LAN Cabling Systems

Fiber Optic Cabling System DINTEKApplications:

FTTH

LAN-to-LAN Fiber Link

Add/Drop Converter

Fiber Extender / Single-mode to Multimode Converter

100Base-Fx Fiber

Singlemode or Multimode Singlemode or Multimode

100Base-Fx Fiber

SNMP MANAGER

1000Base-SX/LX Fiber

Intelligent Switch

100Base-Fx Fiber

10/100Base-TX Auto Sensing 100Base-Fx Fiber

FTTH10/100Base-TX Auto Sensing 100Base-Fx Fiber

Daisy Chain

100Base-Fx Fiber 100Base-Fx Fiber 100Base-Fx Fiber

Daisy Chain

Page 15: Fiber Optic Cabling System DINTEK - systechonline.com · 52 LAN Cabling Systems Fiber Optic Cabling System DINTEK Standard ST/ST, ST/SC and SC/SC fiber optic patch cables Simplex

62

LAN Cabling Systems

www.dintek.com.tw

Fiber Optic Cabling System DINTEKFUNCTIONAL DESCRIPTION

Flow ControlThe fast Ethernet switch Supports 802.3x Flow Control for Full-Duplex mode and Back Pressure for Half-Duplex mode. Furthermore, it provides an additional protection function. When it issues continuous 16 Pause ON frames (network abnormal), no more Pause ON frame will be sent.

SCA (Smart Cable Analysis)This function is valid only under point-to-point Ethernet connection with SCA implemented on both end apparatuses. The cable status will be shown by LED indicators.

Aging TimerThe longest time for packets queuing in the buffer can be set to 300 seconds. This can prevent the buffer from being occupied by outdated packets.

Reserved Address Forward FilterThe fast Ethernet switch supports the ability to drop 802.1d specified reserved group MAC address (01-80-C2-00-00-04 to 01-80-C2-00-00-0F). Frames with group MAC address 01-80-C2-00-00-01 (802.3x Pause) and 01-80-C2-00-00-02 (802.3ad LACP) will always be filtered.

Port Base VLANPort 7 (one of the SFP ports) can be set to be VLAN-grouped with each of other ports. This feature is convenient for the FTTH application as Port 7 is set to be the uplink port.Power Saving ModeThe 10M transmit amplitude is depressed in this mode.

LDPS (Link Down Power Saving) ModeWhen the system link down, it will automatically switch to this mode once this function is enabled. In this mode, the system will save power by decreasing the frequency of FLP (fast link pulse).

MLT3 DetectionWhen this function in enabled, it supports the ability to detect MLT3 (for 10 Mbps switch to 100 Mbps).

Broadcast Storm ProtectionA port begins to drop packets if it receives broadcast packets more than the defined threshold.

Aggressive Back-off ModeThe fast Ethernet switch adopts modified (aggressive) back off algorithm if this function is enabled. The maximum back off period is limited to 8-slot time. It makes the fast Ethernet switch have higher transmission priority in a collision event.

High Priority Fiber PortsPackets received from Fiber ports (SFP ports, port 6 and 7) are handled as high priority packets if the function is enabled.

CoS (Class of Service)Packets with high priority tag are handled as high priority packets to share more bandwidth if the function is enabled.

Maximum Packet Size OptionsThe fast Ethernet switch will drop packets with length longer than 1536 bytes if enable the function. On the contrary, it will drop packets with length longer than 1552 bytes

P/N Description Std Pkg Qty

2903-07001 6-Port 10/100Base-TX + 2 100Base SFP ports Switch

2903-07002 Multimode 100Base-FX SFP Transceiver, 2 km

2903-07003 Single-mode 100Base-FX SFP Transceiver, 30 km

2903-07004 Single-mode 100Base-FX SFP Transceiver, 60 km

2903-07005 Single-mode 100Base-FX SFP Transceiver, 80 km

1

1

1

1

1