Manually and mechanically actuated directional control valves Sturdy and reliable! Info 233 For a broad range with the most diverse actuation and installation variants

description

pneumatic

Transcript of Festo

Page 1: Festo

Manually and mechanically actuated directional control valves

Sturdy and reliable!

Info 233

For a broad range with

the most diverse

actuation and

installation variants

Page 2: Festo

Info 233 – Subject to change – 2006/012

Manually and mechanically actuated directional control valves

Impressive and powerful

Mechanically and manually actuated directional control valves for pneumatic

drives – when reliable and accurate metering is called for.

Festo offers a broad range of manually and mechanically actuated directional

control valves with the most diverse actuation and installation variants: front

panel valves; direct actuation; stem, roller, roller lever, button switch, finger

lever, hand lever, foot or whisker actuator – with or without detent.

Connect, lock, detect!

Hand lever valves

The new sensor-enabled hand lever

valves VHER in plastic or metal

design. Ideal for manual actuation of

pneumatic drives. These modern hand

lever valves are characterised by

robustness and additional functions

such as lockability, position detection,

selectable outlet directions as well as

the practical inscription system.

Front panel valves and actuator

attachments

For manual control of pneumatic

power valves in plastic or metal.

Various actuator attachments such as

toggle and selector switches, key and

pushbutton actuators as well as

mushroom pushbuttons are available.

Safety as standard: the mushroom

pushbutton with detent also available

lockable.

Valves with barbed fittings

The valves with push-on PK-3

connectors are mechanically or

manually actuated valves in plastic

design for actuation of pneumatic

power valves. The comprehensive

actuation options in the form of stem

actuated, pushbutton, toggle lever,

finger lever, whisker, roller or roller

lever valves make this valve system

really versatile.

Valves with threaded connections

The valves with threaded connection

are metal valves that can be directly

or indirectly actuated. The wide range

of actuation types means that the

valves can be universally used. Stem

actuated, pushbutton, toggle lever,

finger lever, whisker, roller or roller

lever valves are available. Available in

the connection sizes M5, Gx or G¼.

Page 3: Festo

2006/01 – Subject to change – Info 233 3

New: Lockable and sensor-enabled –

the 4/3-way hand lever valve VHER

Ideal for manual and direct actuation

of pneumatic drives. This modern

hand lever valve is characterised by

robustness, additional options such

as lockability, position detection,

various outlet directions and the

practical inscription system.

1 Large inscription area

directly on the hand lever.

2 Sturdy plastic lever

Ergonomic hand lever guarantees

secure operation.

3 Lockable hand lever

for greater safety during servicing

and maintenance even during

operation. Lockable in three positions

or switching positions.

4 Position sensing of the hand

lever position

Sensor-assisted option for monitoring

by a higher-level control system.

Sensor slot suitable for SME-10

sensors from Festo, for example

(sensing of three switching positions).

5 Sturdy metal or plastic housing

permits operation in harsh environ-

ments. A further series with metal

housing and lever permits use in

welding shops or foundries.

6 Variable attachment

for simple control panel, wall or base-

plate assembly.

7 Various connection direction and

mounting options

Outlet direction downward or to the

side.

Use as a main pneumatic switch

or as a 3/3-way valve.

Page 4: Festo

Info 233 – Subject to change – 2006/014

Hand lever valves VHERKey features

Powerful Versatile Practical

-M- Flow rate

130 ... 4,300 l/min

� 4/3-way valve

mid-position closed

mid-position exhausted

� Connections: M5, Gx, G¼, G½

� 3/3-way valve

The hand lever valves VHER and HS

can be used as 3/3-way valves by

sealing port 2

With these valves it is possible to stop

single-acting cylinders (3/3-way valve)

or double-acting cylinders (4/3-way

valve) within the stroke range.

In mid-position closed, the drive

piston moves until the forces are

balanced.

In mid-position exhausted the piston

can be moved manually; only the

frictional forces have to be overcome.

Page 5: Festo

2006/01 – Subject to change – Info 233 5

Hand lever valves VHERProduct range overview

Function Version Type Nominal Lever Connection � Pageyp

flow rate Plastic Metal

g

[l/min] small large small large M5 Gx G¼ G½

Ports underneath

VHER-AH-M04C-G18-UD 800 – – � – – � – – 9

VHER-AH-M04C-G14-UD 1,500 – – – � – – � –

9

VHER-AH-M04C-G12-UD 4,300 – – – � – – – �

VHER-BH-M04C-M05-UD 260 � – – – � – – – 16

VHER-BH-M04C-G18-UD 800 � – – – – � – –

VHER-BH-M04C-G14-UD 1,500 – � – – – – � –

VHER-BH-M04C-G12-UD 4,300 – � – – – – �

Ports at side

VHER-AH-M04C-G18-LD 600 – – � – – � – – 9

VHER-AH-M04C-G14-LD 1,150 – – – � – – � –

9

VHER-AH-M04C-G12-LD 3,500 – – – � – – �

VHER-BH-M04C-M05-LD 170 � – – – � – – – 16

VHER-BH-M04C-G18-LD 600 � – – – – � – –

VHER-BH-M04C-G14-LD 1,150 – � – – – – � –

VHER-BH-M04C-G12-LD 3,500 – � – – – – – �

Ports underneath

VHER-AH-M04E-G18-UD 800 – – � – – � – – 9

VHER-AH-M04E-G14-UD 1,500 – – – � – – �

9

VHER-AH-M04E-G12-UD 4,300 – – – � – – – �

VHER-BH-M04E-M05-UD 260 � – – – � – – 16

VHER-BH-M04E-G18-UD 800 � – – – – � – –

VHER-BH-M04E-G14-UD 1,500 – � – – – – � –

VHER-BH-M04E-G12-UD 4,300 – � – – – – – �

Ports at side

VHER-AH-M04E-G18-LD 600 – – � – – � – – 9

VHER-AH-M04E-G14-LD 1,150 – – – � – – � –

9

VHER-AH-M04E-G12-LD 3,500 – – – � – – – �

VHER-BH-M04E-M05-LD 170 � – – – � – – – 16

VHER-BH-M04E-G18-LD 600 � – – – – � – –

VHER-BH-M04E-G14-LD 1,150 – � – – – – � –

VHER-BH-M04E-G12-LD 3,500 – � – – – – – �

Page 6: Festo

Info 233 – Subject to change – 2006/016

Hand lever valves VHERType codes

VHER – BH – M04C – M05 – LD

Type

VHER Hand lever valve with detent

Construction

AH Lever in metal version

BH Lever in polymer version

Valve function

M04C 4/3-way valve, mid-position closed

M04E 4/3-way valve, mid-position exhausted

Connection

M05 M5 (polymer version only)

G18 Gx

G14 G¼

G12 G½

Connection type

LD To the side

UD Underneath

Page 7: Festo

2006/01 – Subject to change – Info 233 7

Hand lever valves VHERPeripherals overview

Control panel installation

8

9

4

5

aJ

7

7

1

7

7

3

6aA

2

5

4

aBaC

Component parts and accessories Brief description � Page

1 Hand lever valves VHER Connection size GÁ and G½ 9

2 Actuating lever Large, polymer –

3 Lever securing clip Large –

4 Inscription label –

5 Control panel Not included in scope of delivery –

6 Mounting screws Not included in scope of delivery –

7 Proximity sensor

SME-10-L, SME-10-Q

Not included in scope of delivery 24

� www.festo.com

8 Hand lever valves VHER Connection size M5 and Gx 9

9 Knurled nut Control panel mounting –

aJ Actuating lever Small, polymer –

aA Lever securing clip Small –

aB Actuating lever Small, metal –

aC Actuating lever Large, metal –

Page 8: Festo

Info 233 – Subject to change – 2006/018

Hand lever valves VHERPeripherals overview

Assembled valves with accessories

2

3

4

1

2

4

56

Component parts and accessories Brief description � Page

1 Hand lever valves VHER Connection size G¼ and G½ with polymer lever 16

2 Padlock Not included in scope of delivery –

3 Hand lever valves VHER Connection size M5 and Gx with polymer lever 16

4 Proximity sensor

SME-10F-… L-… , SME-10F-… Q-…

Not included in scope of delivery 24

� www.festo.com

5 Hand lever valves VHER Connection size Gx with metal lever 9

6 Hand lever valves VHER Connection size G¼ and G½ with metal lever 9

Page 9: Festo

2006/01 – Subject to change – Info 233 9

Hand lever valves VHER-AHTechnical data VHER with metal lever

-M- Flow rate

600 … 4,300 l/min

-L- Pressure

–0.95 … +10 bar

-Q- Temperature range

–20 … +80 °C

General technical data

Pneumatic connection Gx G¼ G½

Valve function 4/3-way, closed or exhausted

Design Rotary slide valve

Sealing principle Hard

Type of mounting Option of front panel mounting or through-holes

Pilot control mode Direct

Actuation type Manual

Actuating lever Metal

Switching position display Via accessories

Assembly position Any

Direction of flow Reversible

Non-overlapping Yes

Exhaust function Flow control

Standard nominal flow rate Ports at side [l/min] 600 1,150 3,500

Ports underneath [l/min] 800 1,500 4,300

Nominal size [mm] 6 8 12

Pneumatic connection 1,2,3,4 Gx G¼ G½

Actuating torque at 10 bar [Nm] 1.1 2.8 5

Operating and environmental conditions

Operating medium Filtered compressed air, lubricated or unlubricated, grade of filtration 40µm

Operating pressure [bar] –0.95 … 10

Ambient temperature [°C] –20 … +80

Corrosion resistance class [CRC] 21)

*

1) Corrosion resistance class 2 according to Festo standard 940 070

Components requiring moderate corrosion resistance. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants

or lubricating agents.

Proximity sensors for switching position display

Pneumatic connection Connection direction Type

SME-10F-… L-… SME-10F-… Q-…

Gx Underneath (UD) � �x

Side (LD) – �

G¼ Underneath � �¼

Side – �

G½ Underneath � �½

Side – �

Page 10: Festo

Info 233 – Subject to change – 2006/0110

Hand lever valves VHER-AHTechnical data VHER with metal lever

Sectional view

Hand lever valves VHER-AH-…

1

1

Materials

1 Housing Die-cast aluminium

– Seals Nitrile rubber

– Contains PWIS (paint wetting impairment substances)

– Free of copper and PTFE

Page 11: Festo

2006/01 – Subject to change – Info 233 11

Hand lever valves VHER-AHTechnical data VHER with metal lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports Gx, side

1 Sensor slot for SME-10-… 2 Material thickness for control

panel installation

3 Knurled nut

Type B1 B2 B3 D1 D2

H1 H2 H3 H4 L1 L2 L3 L4 T1

VHER-AH-…-G18-LD 51 45 28.5 Gx 3 94 45 15 7.5 85 60.5 54.5 3 2 … 4

Page 12: Festo

Info 233 – Subject to change – 2006/0112

Hand lever valves VHER-AHTechnical data VHER with metal lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports Gx, underneath

1 Sensor slot for SME-10-… 2 Material thickness for control

panel installation

3 Knurled nut

Type B1 B3 B4 D1 D3

D4 H1 H2 H5 L1 L2 L5 L6 T1

VHER-AH-…-G18-UD 42 24 32 Gx 5.5 M30 87 37 32.5 79 45 24 9 2 … 4

Page 13: Festo

2006/01 – Subject to change – Info 233 13

Hand lever valves VHER-AHTechnical data VHER with metal lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports G¼ and G½, side

1 Sensor slot for SME-10-…

Type B1 B2 B3 D1 D2

H1 H2 H3 H4 L1 L2 L3 L4

VHER-AH-…-G14-LD 66 57.5 37.5 G¼ 4.5 136 56 20.5 10.3 165 77 69.2 4

VHER-AH-…-G12-LD 95 85 57 G½ 5.5 149 68 29 14.5 180 108.5 97.3 5.5

Page 14: Festo

Info 233 – Subject to change – 2006/0114

Hand lever valves VHER-AHTechnical data VHER with metal lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports G¼ and G½, underneath

1 Sensor slot for SME-10-…

Type B1 B2 B3 B4 D1 D2 D3

D4

H1 H2 H5 L1 L2 L3 L4 L5 L6 T1

VHER-AH-…-G14-UD 56 42 33 42 G¼ M5 5.5 40 130 49 43.5 157 60 42 7.2 33 11.4 12

VHER-AH-…-G12-UD 80 60 50 60 G½ M6 6.4 50 137 55.8 49.8 169 85 60 10 50 15 13

Page 15: Festo

2006/01 – Subject to change – Info 233 15

Hand lever valves VHER-AHTechnical data VHER with metal lever

Ordering data

Circuit symbol Description Weight

[g]

Connection

direction

Pneumatic

connection

Part No. Type

4/3-way valve1)

Mid-position 260 Side GÁ 538 178 VHER-AH-M04C-G18-LDp

closed 560 G¼ 538 180 VHER-AH-M04C-G14-LD

1,010 G½ 538 182 VHER-AH-M04C-G12-LD

220 Underneath GÁ 538 179 VHER-AH-M04C-G18-UD

510 G¼ 538 181 VHER-AH-M04C-G14-UD

860 G½ 538 183 VHER-AH-M04C-G12-UD

Mid-position 260 Side Gx 538 184 VHER-AH-M04E-G18-LDp

exhausted 560 G¼ 538 186 VHER-AH-M04E-G14-LD

1,010 G½ 538 188 VHER-AH-M04E-G12-LD

220 Underneath Gx 538 185 VHER-AH-M04E-G18-UD

510 G¼ 538 187 VHER-AH-M04E-G14-UD

860 G½ 538 189 VHER-AH-M04E-G12-UD

1) The hand lever valve can be used as a 3/3-way valve by sealing port 2.

Page 16: Festo

Info 233 – Subject to change – 2006/0116

Hand lever valves VHER-BHTechnical data VHER with plastic lever

-M- Flow rate

170 … 4,300 l/min

-L- Pressure

–0.95 … +10 bar

-Q- Temperature range

–20 … +80 °C

General technical data

Pneumatic connection M5 Gx G¼ G½

Valve function 4/3-way, closed or exhausted

Design Rotary slide valve

Sealing principle Hard

Type of mounting Front panel

mounting

Option of front panel mounting or through-holes

Pilot control mode Direct

Actuation type Manual

Actuating lever Polymer

Actuator lock Lockable with accessories

Switching position display Via accessories

Assembly position Any

Direction of flow Reversible

Standard nominal flow rate Ports at side [l/min] 170 600 1,150 3,500

Ports underneath [l/min] 260 800 1,500 4,300

Nominal size [mm] 4 6 8 12

Pneumatic connection 1,2,3,4 M5 Gx G¼ G½

Actuating force at 6 bar [N]

Actuating torque at 10 bar [Nm] 0.6 1.1 2.8 –

Operating and environmental conditions

Operating medium Filtered compressed air, lubricated or unlubricated, grade of filtration 40µm

Operating pressure [bar] –0.95 … 10

Ambient temperature [°C] –20 … +80

Corrosion resistance class [CRC] 21)

*

1) Corrosion resistance class 2 according to Festo standard 940 070

Components requiring moderate corrosion resistance. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants

or lubricating agents.

Proximity sensors for switching position display

Pneumatic connection Connection direction Type

SME-10F-… L-… SME-10F-… Q-…

M5 Underneath (UD) � �5

Side (LD) – �

Gx Underneath � �x

Side – �

G¼ Underneath � �¼

Side – �

G½ Underneath � �½

Side – �

Page 17: Festo

2006/01 – Subject to change – Info 233 17

Hand lever valves VHER-BHTechnical data VHER with plastic lever

Sectional view

Hand lever valves VHER-BH-…

1

1

Materials

1 Housing Reinforced PA or die-cast aluminium

– Seals Nitrile rubber

– Contains PWIS (paint wetting impairment substances)

– Free of copper and PTFE (paint wetting impairment substances)

Page 18: Festo

Info 233 – Subject to change – 2006/0118

Hand lever valves VHER-BHTechnical data VHER with plastic lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports M5 and Gx, side

1 Sensor slot for SME-10-… 2 Hole for padlock, dia. 7.2 3 Locking button, lockable 6 Lever securing clip, detachable

Type B1 B2 B3 D1 D2

H1 H2 H3 H4 L1 L2 L3 L4

VHER-BH-…-M05-LD 37 32 17.4 M5 2.5 82 32 10 5 78 45 40 2.5

VHER-BH-…-G18-LD 51 45 28.5 Gx 3 94 45 15 7.5 85 60.5 54.5 3

Page 19: Festo

2006/01 – Subject to change – Info 233 19

Hand lever valves VHER-BHTechnical data VHER with plastic lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports M5 and Gx, underneath

1 Sensor slot for SME-10-…

2 Hole for padlock, dia. 7.2

3 Locking button, lockable 4 Material thickness for control

panel installation

5 Knurled nut

6 Lever securing clip, detachable

Type B1 B3 B4 D1 D3

D4 H1 H2 H5 L1 L2 L5 L6 T1

VHER-BH-…-M05-UD 30 17 - M5 - M22 79 28.6 - 73 33.8 17 6.5 2 … 4

VHER-BH-…-G18-UD 42 24 32 Gx 5.5 M30 86 37 32.5 79 45 24 9 1.5 … 4.5

Page 20: Festo

Info 233 – Subject to change – 2006/0120

Hand lever valves VHER-BHTechnical data VHER with plastic lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports G¼ and G½, side

2 Hole for padlock, dia. 7.2 3 Locking button, lockable 6 Lever securing clip, detachable

Type B1 B2 B3 D1 D2

H1 H2 H3 H4 L1 L2 L3 L4

VHER-BH-…-G14-LD 66 57.5 37.5 G¼ 4.3 136 55.5 20.5 10.25 166 77 69.2 4

VHER-BH-…-G12-LD 96 85 57 G½ 5.3 148 67.8 29 14.5 180 108.5 97.3 5.5

Page 21: Festo

2006/01 – Subject to change – Info 233 21

Hand lever valves VHER-BHTechnical data VHER with plastic lever

Dimensions Download CAD data� www.festo.com/en/engineering

Ports G¼ and G½, underneath

2 Hole for padlock, dia. 7.2 3 Locking button, lockable 6 Lever securing clip, detachable

Type B1 B2 B3 B4 D1 D2 D3

D4 H1 H2 H5 L1 L2 L3 L4 L5 L6 T1

VHER-BH-…-G14-UD 56.3 42 33 42 G¼ M5 5.4 40.5 129 49 43.5 157 60.2 42 7.2 33 11.7 13

VHER-BH-…-G12-UD 80 60 50 60 G½ M6 6.5 51 137 55.8 49.8 169 84.8 60 10 50 15 16

Page 22: Festo

Info 233 – Subject to change – 2006/0122

Hand lever valves VHER-BHTechnical data VHER with plastic lever

Ordering data

Circuit symbol Description Weight

[g]

Connection

direction

Pneumatic

connection

Part No. Type

4/3-way valve1)

Mid-position 95 Side M5 538 190 VHER-BH-M04C-M05-LDp

closed 165 Gx 538 192 VHER-BH-M04C-G18-LD

435 G¼ 538 194 VHER-BH-M04C-G14-LD

900 G½ 538 196 VHER-BH-M04C-G12-LD

80 Underneath M5 538 191 VHER-BH-M04C-M05-UD

125 Gx 538 193 VHER-BH-M04C-G18-UD

375 G¼ 538 195 VHER-BH-M04C-G14-UD

740 G½ 538 197 VHER-BH-M04C-G12-UD

Mid-position 95 Side M5 538 198 VHER-BH-M04E-M05-LDp

exhausted 165 Gx 538 200 VHER-BH-M04E-G18-LD

435 G¼ 538 202 VHER-BH-M04E-G14-LD

900 G½ 538 204 VHER-BH-M04E-G12-LD

80 Underneath M5 538 199 VHER-BH-M04E-M05-UD

125 Gx 538 201 VHER-BH-M04E-G18-UD

375 G¼ 538 203 VHER-BH-M04E-G14-UD

740 G½ 538 205 VHER-BH-M04E-G12-UD

1) The hand lever valve can be used as a 3/3-way valve by sealing port 2.

Page 23: Festo

2006/01 – Subject to change – Info 233 23

Hand lever valves HS/HSO/VHERAccessories

Ordering data

Description Pneumatic connection Part No. Type

Blanking plugs

For sealing ports M5 3 843 B-M51)g p

Gx 3 568 B-x1)

G¼ 3 569 B-¼1)

G½ 3 571 B-½1)

Silencers

For fitting in exhaust ports – � www.festo.com

Push-in fittings QS

For connecting compressed air tubing with

standard O.D. to CETOP RP 54 P

– � www.festo.com

Permissible QS fittings1) for VHER

Part No. Type Part No. Type Part No. Type Part No. Type

VHER-…-M05-UD VHER-…-M05-LD VHER-…-G18-UD VHER-…-G18-LD

153 302 QSM-M5-3 153 313 QSM-M5-3-I 186 264 QSM-Gx-4 186 266 QSM-Gx-4-I

153 304 QSM-M5-4 153 315 QSM-M5-4-I 186 265 QSM-Gx-6 186 267 QSM-Gx-6-I

153 306 QSM-M5-6 186 266 QSM-Gx-4-I 186 106 QS-Gx-4-I

153 313 QSM-M5-3-I 186 267 QSM-Gx-6-I 186 107 QS-Gx-6-I

153 315 QSM-M5-4-I 186 095 QS-Gx-4 186 109 QS-Gx-8-I

153 317 QSM-M5-6-I 186 096 QS-Gx-6

186 098 QS-Gx-8

186 106 QS-Gx-4-I

186 107 QS-Gx-6-I

186 109 QS-Gx-8-I

VHER-…-G14-UD VHER-…-G14-LD VHER-…-G12-UD VHER-…-G12-LD

186 097 QS-G¼-6 186 108 QS-G¼-6-I 186 104 QS-G½-12 186 115 QS-G½-12-I

186 099 QS-G¼-8 186 110 QS-G¼-8-I 186 105 QS-G½-16

186 101 QS-G¼-10 186 112 QS-G¼-10-I 186 115 QS-G½-12-I

186 108 QS-G¼-6-I

186 110 QS-G¼-8-I

186 112 QS-G¼-10-I

1) Scope of delivery 10 pieces

Permissible silencers for VHER

Part No. Type Part No. Type Part No. Type Part No. Type

VHER-…-M05-UD VHER-…-M05-LD VHER-…-G18-UD VHER-…-G18-LD

4 645 U-M5 4 645 U-M5 6 841 U-x-B 161 419 UC-x

165 003 UC-M5 165 003 UC-M5 161 419 UC-x

2 307 U-x

VHER-…-G14-UD VHER-…-G14-LD VHER-…-G12-UD VHER-…-G12-LD

6 842 U-¼-B 165 004 UC-¼ 6 844 U-½-B 6 844 U-½-B

165 004 UC-¼

2 316 U-¼

Core Range

Page 24: Festo

Info 233 – Subject to change – 2006/0124

Hand lever valves VHERAccessories

Ordering data – Proximity sensors for VHER

Electrical connection Cable length Connection Part No. Type

Cable Plug M8x1 [m] direction

yp

N/O contact

3-wire – 2.5 In-line 173 210 SME-10-KL-LED-243 5

Lateral 173 211 SME-10-KQ-LED-24

– 3-pin 0.3 In-line 173 212 SME-10-SL-LED-243 p 3

Lateral 173 213 SME-10-SQ-LED-24

Page 25: Festo

2006/01 – Subject to change – Info 233 25

Panel-mounting valves and actuating attachmentsKey features

SV-3-M5

T-22

SV-5-M5-B

Q-22PRS-22H-22N-22PR-22P-22

Mushroom pushbutton with detent

PR

Key actuator Q

With key

Basic valve SV-3-M5 Basic valve SV-5-M5-B

The actuator is unlocked by turning

the detent ring at the mushroom

button.

The key actuator can only be activated

with the key. The key can be removed

in either switch position.

Mushroom pushbutton with detent

PRS

Lockable

After pressing, the button remains

locked and can only be unlatched with

the key. The key can be removed in

either switch position.

Page 26: Festo

Info 233 – Subject to change – 2006/0126

Panel-mounting valves and actuating attachmentsTechnical data

-M- Flow rate

65 … 95 l/min

-L- Pressure

–0.9 … +8 bar

0 … 8 bar

-Q- Temperature range

–10 … +60 °C

General technical data – Basic valves

Function 3/2-way valve 5/2-way valve

Operating medium Filtered compressed air, lubricated or unlubricated

Vacuum1)

Constructional design Poppet valve, directly actuated in one direction, with spring return

Type of mounting Front panel mounting, mounting diameters 22.5 and 30.5 mm, also 2 through-holes

Pneumatic connection M5

Nominal size [mm] 2 2.3

Standard nominal flow rate 1 > 2 [l/min] 65 95

Operating pressure range [bar] –0.95 ... +8 0 ... +8

Actuating force at 6 bar [N] 12 17

Temperature range [°C] –10 ... +60

Materials Housing Plastic

Valve stem Brass

Seals Nitrile rubber

Weight [g] 40 53

1) SV-3-M5: Vacuum connection at port 1

General technical data – Actuator attachments

Pushbutton

actuator

Mushroom

pushbutton

Mushroom pushbutton with

detent

Selector

switch

Toggle switch Key actuator

with key

Red Red

Lockable

y

Actuating force / actuating torque at

6 bar

[Nm] 14 14 25 23 0.4 0.14 23

Weights Installation

diameter 22.5

[g] 14 20 26 82 21 19 80

Installation

diameter 30.5

[g] 22 28 37 91 30 27 88

Page 27: Festo

2006/01 – Subject to change – Info 233 27

Panel-mounting valves and actuating attachmentsTechnical data

Dimensions – Basic valves Download CAD data� www.festo.com/en/engineering

SV-3-M5 SV-5-M5-B

1 Quick latching coupler for

actuator attachments

2 Installation dimensions

for∅ 22.5

3 Installation dimensions

for∅ 30.5

4 Max. stroke

5 Start of opening

6 Max. opening

s Front panel thickness

1 Supply port

2, 4 Working line

3, 5 Exhaust

Mounting aperture

Installation diameter 22.5 Installation diameter 30.5

Dimensions – Actuator attachments Download CAD data� www.festo.com/en/engineering

Installation diameter 22.5

Pushbutton actuator T-22 Mushroom pushbutton P-22 Mushroom pushbutton with detent,

lockable PR-22

Mushroom pushbutton with detent,

lockable PRS-22

Page 28: Festo

Info 233 – Subject to change – 2006/0128

Panel-mounting valves and actuating attachmentsTechnical data

Dimensions – Actuator attachments for front panel mounting Download CAD data� www.festo.com/en/engineering

Installation diameter 22.5

Selector switch N-22 Toggle switch H-22 Key actuator Q-22

Installation diameter 30.5

Pushbutton actuator T-30 Mushroom pushbutton P-30 Mushroom pushbutton with detent,

lockable PR-30

Mushroom pushbutton with detent,

lockable PRS-30

Selector switch N-30 Toggle switch H-30 Key actuator Q-30

Type N

4 = Off

5 = On

Type PR

The actuator is unlocked by turning

the detent ring at the mushroom

button.

Type PRS

After pressing, the button remains

locked and can only be unlatched

with the key. The key can be

removed in either switch position.

Type Q

The key actuator can only be

activated with the key.

The key can be removed in either

switch position.

Page 29: Festo

2006/01 – Subject to change – Info 233 29

Panel-mounting valves and actuating attachmentsTechnical data

Ordering data – Basic valves

Circuit symbol Description Part No. Type

3/2-way valve 6817 SV-3-M5

5/2-way valve 11 914 SV-5-M5-B

Ordering data – Actuator attachments

Circuit symbol Description Installation diameter 22.5 Installation diameter 30.5

Part No. Type Part No. Type

Pushbutton actuator Pushbutton actuator

Black 9 289 T-22-SW 9 291 T-30-SW

Yellow 9 290 T-22-GE 9 292 T-30-GE

Red 9 997 T-22-RT 10 014 T-30-RT

Mushroom pushbutton

Black 9 293 P-22-SW 9 295 P-30-SW

Mushroom pushbutton with detent

Red 9 297 PR-22-RT 9 298 PR-30-RT

Red, lockable 9 299 PRS-22-RT 9 300 PRS-30-RT

Selector switch

Black 9 301 N-22-SW 9 302 N-30-SW

Toggle switch

Black 9 305 H-22-SW 9 306 H-30-SW

Key actuator with key

– 9 303 Q-22 9 304 Q-30

Page 30: Festo

Info 233 – Subject to change – 2006/0130

Valves with push-on fittingsKey features

V/O-3-PK-3 R/O-3-PK-3 L/O-3-PK-3

K/O-3-PK-3 TH/O-3-PK-3 KH/O-3-PK-3

Push-on fitting connection V/O-3-PK-3

� Directly actuated valves

� Polymer design

� Ducted exhaust air

The push-on fitting is suitable for

plastic tubing with a standard internal

diameter� www.festo.com

Page 31: Festo

2006/01 – Subject to change – Info 233 31

Valves with push-on fittingsTechnical data

-M- Flow rate

80 l/min

-L- Pressure

0 … 8 bar

-Q- Temperature range

–10 … +60 °C

General technical data

Actuation type Stem actuated

valve

Roller lever

valve

Roller lever

valve with idle

return

Push-button

valve

Finger lever

valve

Toggle lever

valve

Constructional design Poppet valve, directly actuated

Type of mounting Through-holes in housing

Pneumatic connection Barbed fitting for 3 mm plastic tubing

Nominal size [mm] 2.5

Standard nominal flow rate 1 > 2 [l/min] 80

Operating pressure range [bar] 0 … 8

Actuating force at 6 bar

Normally closed [N] 17 10 10 17 6 6.5

Normally open [N] 24 15 13 24 8 7.5

Temperature range [°C] –10 … +60

Materials Housing Plastic

Seals Nitrile rubber

Weight [g] 20 18 19 20 18 20

Dimensions Download CAD data� www.festo.com/en/engineering

Stem actuated valve V/O Roller lever valve R/O

1 Barbed fitting for tubing with

an internal∅ of 3 mm

2 Max. stroke

3 Max. opening

4 Start of opening

Page 32: Festo

Info 233 – Subject to change – 2006/0132

Valves with push-on fittingsTechnical data

Dimensions Download CAD data� www.festo.com/en/engineering

Roller lever valve with idle return L/O Push-button valve K/O

2 Max. stroke

3 Max. opening

4 Start of opening

5 Switching travel

Finger lever valve TH/O Toggle lever valve KH/O

Ordering data

Circuit symbol Actuation type Part No. Type

Stem actuated valve 10 747 V/O-3-PK-3

Roller lever valve 10 748 R/O-3-PK-3

Roller lever valve with idle return 10 749 L/O-3-PK-3

Push-button valve 13 793 K/O-3-PK-3

Finger lever valve 13 794 TH/O-3-PK-3

Toggle lever valve 33 003 KH/O-3-PK-3

Page 33: Festo

2006/01 – Subject to change – Info 233 33

Valves with push-on fittingsAccessories

Mounting bracket HV-M5

Material:

Galvanised steel

Ordering data

Weight Part No. Type

[g]

Mounting bracket 11 9 634 HV-M5

Page 34: Festo

Info 233 – Subject to change – 2006/0134

Valves with threaded connections M5Key features

V-3-M5 R-3-M5 L-3-M5

K-3-M5 TH-3-M5

V-3-M5

-M- Flow rate

80 l/min

� 3/2-way valve

normally closed

� Connection M5

� Compact design

Page 35: Festo

2006/01 – Subject to change – Info 233 35

Valves with threaded connections M5Technical data

-M- Flow rate

80 l/min

-L- Pressure

–0.95 … +8 bar

-Q- Temperature range

–10 … +60 °C

General technical data

Actuation type Stem actuated

valve

Roller lever valve Roller lever valve

with idle return

Push-button valve Finger lever valve

Operating medium Filtered compressed air, lubricated or unlubricated

Vacuum1)

Constructional design Poppet valve, directly actuated

Type of mounting 2 through-holes in housing

Pneumatic connection M5

Nominal size [mm] 2

Standard nominal flow rate 1 > 2 [l/min] 80

Operating pressure range [bar] –0.95 ... 8

Actuating force at 6 bar [N] 23 12.5 12.5 23 8

Temperature range [°C] –10 ... +60

Materials Housing Die-cast zinc

Seals Nitrile rubber

Weight [g] 25 40 43 28 37

1) Vacuum connection at port 1

Dimensions Download CAD data� www.festo.com/en/engineering

Stem actuated valve V Roller lever valve R

1 Switching travel

Page 36: Festo

Info 233 – Subject to change – 2006/0136

Valves with threaded connections M5Technical data

Dimensions Download CAD data� www.festo.com/en/engineering

Roller lever valve L Push-button valve K

Finger lever valve TH

1 Switching travel

Ordering data – Basic valves

Circuit symbol Actuation type Part No. Type

Stem actuated valve 3 626 V-3-M5

Roller lever valve 3 629 R-3-M5

Roller lever valve with idle return 3 628 L-3-M5

Push-button valve 3 660 K-3-M5

Finger lever valve 6 758 TH-3-M5

Ordering data – Actuator attachments

Circuit symbol Actuation type Part No. Type

Roller lever

with mounting screws

6 512 AR-05

Idle return roller lever

with mounting screws

6 513 AL-05

Page 37: Festo

2006/01 – Subject to change – Info 233 37

Valves with threaded connections M5Accessories

Mounting bracket HV-M5

Material:

Galvanised steel

Ordering data

Weight Part No. Type

[g]

Mounting bracket 11 9 634 HV-M5

Page 38: Festo

Info 233 – Subject to change – 2006/0138

Valves with threaded connections Gx, directly actuatedKey features

V/O-3-x

AR-01

AL-01 ASS-02

ASL-02

ASK-02

RW/O-3-x

Normally closed

-M- Flow rate

140 l/min

� 3/2-way valve

Normally closed Normally open

depending upon selected

connections

� Connection Gx

� Actuator attachments

as desired

The swivel lever valve is mechanically

actuated with an eccentric rod.

Various actuating ranges can be

selected by repositioning

2 components in the control actuator.

Page 39: Festo

2006/01 – Subject to change – Info 233 39

Valves with threaded connections Gx, directly actuatedTechnical data

-M- Flow rate

140 l/min

-L- Pressure

–0.95 … +8 bar

-Q- Temperature range

–10 … +60 °C

General technical data – Basic valves

Actuation type Stem actuated valve Swivel lever valve

Operating medium Filtered compressed air, lubricated or unlubricated

Vacuum1)

Constructional design Poppet valve, directly actuated

Type of mounting 2 through-holes in housing

Pneumatic connection Gx

Nominal size [mm] 3.5

Standard nominal flow rate 1 > 2 [l/min] 140

Operating pressure range [bar] –0.95 ... +8

Actuating force at 6 bar [N] 28

Temperature range [°C] –10 ... +60

Materials Housing Blue anodised aluminium

Seals Nitrile rubber

Weight [g] 90 150

1) Vacuum connection at port 1 or 11

General technical data – Actuator attachments

Roller lever Idle return roller

lever

Swivel lever, short Swivel lever, long Swivel lever rod

Actuating force [N] min. – – – – –g [ ]

max. 10 12 7 1) 1)

Material Galvanised steel Aluminium, steel Aluminium, steel

Weight [g] 42 52 30 35 30

1) Dependent upon starting height

Page 40: Festo

Info 233 – Subject to change – 2006/0140

Valves with threaded connections Gx, directly actuatedTechnical data

Dimensions Download CAD data� www.festo.com/en/engineering

Stem actuated valve V/O Roller lever AR-01

Idle return roller lever AL-01

1 Max. stroke

2 Max. opening

3 Start of opening

4 Min. actuation stroke

5 Actuation direction

Page 41: Festo

2006/01 – Subject to change – Info 233 41

Valves with threaded connections Gx, directly actuatedTechnical data

Dimensions Download CAD data� www.festo.com/en/engineering

Swivel lever valve RW/O

1, 11 = Supply port

2 = Working line

3, 33 = Exhaust

Swivel lever, short ASK-02 Swivel lever, long ASL-02 Swivel lever rod ASS-02

Actuating ranges are set by converting the switching head

Default settings (upon delivery)

Start of opening

Max. openingIdling

Overtravel

Valve actuating head and body turned 90° around the longitudinal axis Valve actuating head and body turned 180° around the longitudinal axis

Start of opening Start of opening

Max. openingMax. opening

OvertravelOvertravel

Start of opening

Max. opening Idling

Overtravel

Page 42: Festo

Info 233 – Subject to change – 2006/0142

Valves with threaded connections Gx, directly actuatedTechnical data

Ordering data

Circuit symbol Actuation type Part No. Type

Stem actuated valve

Basic valve 4 938 V/O-3-x

Actuator attachments

Roller lever 4 936 AR-01

Idle return roller lever 4 941 AL-01

Swivel lever valve

Basic valve 4 937 RW/O-3-x

Actuator attachments

Swivel lever, short 5 835 ASK-02

Swivel lever, long 5 836 ASL-02

Swivel lever rod 4 789 ASS-02

Page 43: Festo

2006/01 – Subject to change – Info 233 43

Valves with threaded connections Gx, indirectly actuatedKey features

VS-3-x RS-3-x LS-3-x

VS-4-x RS-4-x LS-4-x FVS-3-x

Normally closed Normally open

-M- Flow rate

120 l/min

� 3/2-way valves

normally closed

normally open,

changed by repositioning the

housing top

� 4/2-way valves

�Minimal actuating force with pilot

control

� Can also be used as 2/2-way valve

by plugging the exhaust

Page 44: Festo

Info 233 – Subject to change – 2006/0144

Valves with threaded connections Gx, indirectly actuatedTechnical data – 3/2-way valves

-M- Flow rate

120 l/min

-L- Pressure

3.5 … 8 bar

-Q- Temperature range

–10 … +60 °C

Wearing parts kits

� 46

Technical data

Actuation type Stem actuated valve Roller lever valve Toggle lever valve Whisker valve

Constructional design Poppet valve, indirectly actuated

Type of mounting 2 through-holes in housing

Pneumatic connection Gx

Nominal size [mm] 3.5

Standard nominal flow rate 1 > 2 [l/min] 120

Operating pressure range [bar] 3.5 ... 8

Actuating force at 6 bar [N] 3.1 1.8 1.8 � Diagram

Repetition accuracy (+/-) [mm] ±0.1

Temperature range [°C] –10 ... +60

Materials Housing Blue anodised aluminium

Seals Nitrile rubber

Weight [g] 110 120 110 130

Switching forces F and switching travel l at 6 bar in relation to approach distance L

Whisker valve

This piloted valve with extremely low

actuating forces is particularly suited

for units where dissimilar parts or

actuating elements without precision

positioning are to be sensed, or

where the actuating levels are

different. The whisker can be

approached from any direction

perpendicular to the whisker axis, or

can be passed.

1 Switching force

2 Passing force

3 Switching travel

4 Overtravel

5 Permissible approach range

L[mm]

F [N]

l [mm]

Example:

A distance of 30 mm from the end of

the spring results in:

Switching travel of 54 mm

A switching force of 0.57 N

Overtravel of 88 mm

A passing force of 0.75 N

Page 45: Festo

2006/01 – Subject to change – Info 233 45

Valves with threaded connections Gx, indirectly actuatedTechnical data – 3/2-way valves

Sectional view

Normally closed Normally open

Actuator attachment at left

(number 1 on attachment above

number 1 on housing)

Actuator attachment at right

(number 1 on attachment above

number 2 on housing)

Dimensions Download CAD data� www.festo.com/en/engineering

Stem actuated valve VS, VOS Roller lever valve RS, ROS

Toggle lever valve LS, LOS Whisker valve FVS, FVSO

1 Initial position

2 ON position

3 Actuation direction

4 Smallest distance between

cams

5 Bottom edge of control rail or

cam

6 Idle return

7 Min. switching travel

Page 46: Festo

Info 233 – Subject to change – 2006/0146

Valves with threaded connections Gx, indirectly actuatedTechnical data – 3/2-way valves

Ordering data

Circuit symbol Actuation type Part No. Type

3/2-way valves, normally closed

Stem actuated valve 2 334 VS-3-x

Roller lever valve 2 272 RS-3-x

Toggle lever valve 2 186 LS-3-x

Whisker valve 3 876 FVS-3-x

3/2-way valves, normally open

Stem actuated valve 2 952 VOS-3-x

Roller lever valve 2 270 ROS-3-x

Toggle lever valve 2 950 LOS-3-x

Whisker valve 3 877 FVSO-3-x

Ordering data – Wearing parts kits

Part No. Type

For 3/2-way valves 104 222 VS-3-x

Page 47: Festo

2006/01 – Subject to change – Info 233 47

Valves with threaded connections Gx, indirectly actuatedTechnical data – 4/2-way valves

-M- Flow rate

120 l/min

-L- Pressure

3.5 … 8 bar

-Q- Temperature range

–10 … +60 °C

Wearing parts kits

� 48

Technical data

Actuation type Stem actuated valve Roller lever valve Toggle lever valve

Constructional design Poppet valve, indirectly actuated

Type of mounting 2 through-holes in housing

Pneumatic connection Gx

Nominal size [mm] 3.5

Standard nominal flow rate 1 > 2 [l/min] 120

Operating pressure range [bar] 3.5 ... 8

Actuating force at 6 bar [N] 3.1 1.8 2.2

Repetition accuracy (+/-) [mm] ±0.1

Temperature range [°C] –10 ... +60

Materials Housing Blue anodised aluminium

Seals Nitrile rubber

Weight [g] 220 230 230

Sectional view

Stem actuated valve VS-4-x

13

2 41 Supply port

2,4 Working line

3 Exhaust

Page 48: Festo

Info 233 – Subject to change – 2006/0148

Valves with threaded connections Gx, indirectly actuatedTechnical data – 4/2-way valves

Dimensions Download CAD data� www.festo.com/en/engineering

Stem actuated valve VS Roller lever valve RS

Toggle lever valve LS

1 Initial position

2 ON position

3 Actuation direction

4 Smallest distance between

cams

5 Bottom edge of control rail or

cam

6 Idle return

7 Min. switching travel

Ordering data

Circuit symbol Actuation type Part No. Type

Stem actuated valve 3 394 VS-4-x

Roller lever valve 2 949 RS-4-x

Toggle lever valve 3 416 LS-4-x

Ordering data – Wearing parts kits

Part No. Type

For 4/2-way valves 104 201 VS-4-x

Page 49: Festo

2006/01 – Subject to change – Info 233 49

Valves with threaded connections Gx, indirectly actuatedAccessories

Mounting bracket HV-x

Material:

Galvanised steel

Ordering data

Weight Part No. Type

[g]

Mounting bracket 32 9 635 HV-x

Page 50: Festo

Info 233 – Subject to change – 2006/0150

Valves with threaded connections G¼Key features

V-3-¼-B R-3-¼-B TH-3-¼-B H-3-¼-B

V-5-¼-B L-3-¼-B F-3-¼-B FP-3-¼-B

V-3-¼-B,

normally closed

VO-3-¼-B,

normally open

-M- Flow rate

600 l/min

� 3/2-way valves

normally closed

normally open

� 5/2-way valves

� 7 actuator types

Page 51: Festo

2006/01 – Subject to change – Info 233 51

Valves with threaded connections G¼Technical data –3/2-way valves

-M- Flow rate

600 l/min

-L- Pressure

–0.95 … +10 bar

-Q- Temperature range

–10 … +60 °C

Wearing parts kits

� 55

General technical data

Actuation type Stem

actuated

valve

Roller lever

valve

Roller lever

valve with

idle return

Finger lever

valve

Hand lever

valve

Foot valve Foot valve

with

mechanical

detent

Operating medium Filtered compressed air, lubricated or unlubricated

Vacuum1)

Constructional design Poppet valve, directly actuated

Type of mounting 2 through-holes in housing2)

Connection G¼

Nominal size [mm] 7

Standard nominal flow rate 1 > 2 [l/min] 600

Operating pressure range [bar] –0.95 ... +10

Actuating force at 6 bar [N]

Normally closed 37 10 15 6.7 5.5 26 45

Normally open 93 26 38 17 – 37 –

Temperature range [°C] –10 ... +60

Materials Housing Die-cast aluminium

Foot valves: die-cast zinc

Seals Nitrile rubber

Weight Valve [g] 130 230 250 210 320 595 1,760g

Safety guard [g] – – – – – 1,200 660

1) Vacuum connection at port 1

2) Hand lever valve suitable for panel mounting

Foot valves with flange eye on housing

Page 52: Festo

Info 233 – Subject to change – 2006/0152

Valves with threaded connections G¼Technical data – 3/2-way valves

Dimensions Download CAD data� www.festo.com/en/engineering

Stem actuated valve V Roller lever valve R

1 For hex nut M5 DIN 934 2 For hex nut M4 DIN 934 3 Start of opening

4 Max. opening

5 Max. stroke

Roller lever valve with idle return L Finger lever valve TH

3 Start of opening

4 Max. opening

5 Max. stroke

6 Cam operating path

7 Actuation direction

Page 53: Festo

2006/01 – Subject to change – Info 233 53

Valves with threaded connections G¼Technical data – 3/2-way valves

Dimensions Download CAD data� www.festo.com/en/engineering

Hand lever valve H

1 For hex nut M5 DIN 934 2 Locking screw

Page 54: Festo

Info 233 – Subject to change – 2006/0154

Valves with threaded connections G¼Technical data – 3/2-way valves

Dimensions Download CAD data� www.festo.com/en/engineering

Foot valve F

Foot valve FPB with mechanical detent

Foot valve FP with mechanical detent

1 = Supply port

2 = Working line

-H- Note

Foot valves with detent are actuated

by means of a foot lever with

mechanical detent.

The valve engages when it is first

actuated, and when the foot lever is

actuated again, the valve returns to

its initial position.

Page 55: Festo

2006/01 – Subject to change – Info 233 55

Valves with threaded connections G¼Technical data – 3/2-way valves

Ordering data

Circuit symbol Actuation type Part No. Type

Normally closed

Stem actuated valve 6 808 V-3-¼-B

Roller lever valve 8 985 R-3-¼-B

Roller lever valve with idle return 8 982 L-3-¼-B

Finger lever valve 8 983 TH-3-¼-B

Hand lever valve 8 987 H-3-¼-B

Foot valve 8 984 F-3-¼-B

Foot valve with mechanical detent 8 986 FP-3-¼-B

526 985 FPB-3-¼

Normally open

Stem actuated valve 9 157 VO-3-¼-B

Roller lever valve 8 991 RO-3-¼-B

Roller lever valve with idle return 8 989 LO-3-¼-B

Finger lever valve 8 990 THO-3-¼-B

Foot valve 8 988 FO-3-¼-B

Ordering data – Wearing parts kits

Part No. Type

For 3/2-way valves1) 104 503 V-,VO-3-¼-B

1) not for foot valves F, FO, FP, FPB

Page 56: Festo

Info 233 – Subject to change – 2006/0156

Valves with threaded connections G¼Technical data – 5/2-way valves

-M- Flow rate

550 l/min

-L- Pressure

–0.95 … +10 bar

-Q- Temperature range

–10 … +60 °C

Wearing parts kits

� 60

General technical data

Actuation type Stem

actuated

valve

Roller lever

valve

Roller lever

valve with

idle return

Finger lever

valve

Hand lever

valve

Foot valve Foot valve

with

mechanical

detent

Operating medium Filtered compressed air, lubricated or unlubricated

Vacuum1)

Constructional design Poppet valve, directly actuated

Type of mounting 2 through-holes in housing2)

Connection G¼

Nominal size [mm] 7

Standard nominal flow rate 1 > 2 [l/min] 550

Pressure range [bar] –0.95 ... +10

Actuating force at 6 bar [N] 132 35 53 24 22 52 69

Temperature range [°C] –10 ... +60

Materials Housing Die-cast aluminium, types F and FP: die-cast zinc

Seals Nitrile rubber

Weight Valve [g] 240 340 360 320 510 705 1,845g

Safety guard [g] – – – – – 1,200 660

1) Vacuum connection at port 1

2) Hand lever valve suitable for panel mounting

Foot valves with flange eye on housing

Page 57: Festo

2006/01 – Subject to change – Info 233 57

Valves with threaded connections G¼Technical data – 5/2-way valves

Dimensions Download CAD data� www.festo.com/en/engineering

Stem actuated valve V Roller lever valve R

1 For hex nut M5 DIN 934 2 For hex nut M4 DIN 934 3 Start of opening

4 Max. opening

5 Max. stroke

Roller lever valve L Finger lever valve TH

3 Start of opening

4 Max. opening

5 Max. stroke

6 Cam operating path

7 Actuation direction

Page 58: Festo

Info 233 – Subject to change – 2006/0158

Valves with threaded connections G¼Technical data – 5/2-way valves

Dimensions Download CAD data� www.festo.com/en/engineering

Hand lever valve H

1 For hex nut M5 DIN 934 2 Locking screw

Page 59: Festo

2006/01 – Subject to change – Info 233 59

Valves with threaded connections G¼Technical data – 5/2-way valves

Dimensions Download CAD data� www.festo.com/en/engineering

Foot valve F

Foot valve FPB with mechanical detent

Foot valve FP with mechanical detent

-H- Note

Foot valves with detent are actuated

by means of a foot lever with

mechanical detent.

The valve engages when it is first

actuated, and when the foot lever is

actuated again, the valve returns to

its initial position.

Page 60: Festo

Info 233 – Subject to change – 2006/0160

Valves with threaded connections G¼Technical data – 5/2-way valves

Ordering data

Circuit symbol Actuation type Part No. Type

Stem actuated valve 6 809 V-5-¼-B

Roller lever valve 8 996 R-5-¼-B

Roller lever valve with idle return 8 993 L-5-¼-B

Finger lever valve 8 994 TH-5-¼-B

Hand lever valve 8 995 H-5-¼-B

Foot valve 8 992 F-5-¼-B

Foot valve with mechanical detent 8 997 FP-5-¼-B

526 985 FPB-5-¼

Ordering data – Wearing parts kits

Part No. Type

For 5/2-way valves1) 104 502 V-5-¼-B

1) not for foot valves F, FP, FPB

Page 61: Festo

2006/01 – Subject to change – Info 233 61

Valves with threaded connections G¼Accessories

Safety guard FH

Ordering data

Weight Part No. Type

[g]

Safety guard for foot valve F 1,240 4 500 FH

Safety guard FPH-121

Ordering data

Weight Part No. Type

[g]

Safety guard for foot valve FP

with mechanical detent

670 2 071 FPH-121

Page 62: Festo

Info 233 – Subject to change – 2006/0162

Products and services – everything from a single source

Products incorporating new ideas are

created when enthusiasm for techno-

logy and efficiency come together.

Tailor-made service goes without

saying when the customer is the focus

of attention.

Pneumatic and electrical drives Valves and valve terminals Compressed air preparation

� Pneumatic cylinders

� Semi-rotary drives

�Handling modules

� Servopneumatic positioning

systems

� Electromechanical drives

� Positioning controllers and

controllers

� Standard valves

�Universal and application-

optimised valves

�Manually and mechanically

actuated valves

� Shut-off, pressure control and flow

control valves

� Proportional valves

� Safety valves

Fieldbus systems/

electrical peripherals

� Fieldbus Direct

� Installation system CP/CPI

�Modular electrical terminal CPX

� Service unit combinations

� Filter regulators

� Filters

� Pressure regulators

� Lubricators

�On-off and soft-start valves

� Dryers

� Pressure amplifiers

� Accessories for compressed air

preparation

Components

Modules

Systems

Customer-specific solutions

Industry-specific solutions

Services from Festo to increase your productivity – across the entire value creation sequence

< Engineering – for greater speed in

the development process

< Supply chain – for greater speed in

the procurement process

� CAD models

� 14 engineering tools

� Digital catalogue

� FluidDRAW®

�More than 1,000 technical

consultants and project engineers

worldwide

� Technical hotlines

� E-commerce and online shop

�Online order tracking

� Euro special manufacturing service

� Logistics optimisation

Page 63: Festo

2006/01 – Subject to change – Info 233 63

Gripping and vacuum technology Sensors and monitoring units Controllers/bus systems Accessories

� Vacuum generators

� Vacuum grippers

� Vacuum security valves

� Vacuum accessories

� Standard grippers

�Micro grippers

� Precision grippers

�Heavy-duty grippers

� Proximity sensors

� Pressure and flow sensors

� Display and operating units

� Inductive and optical proximity

sensors

� Displacement encoders for

positioning cylinders

�Optical orientation detection and

quality inspection

� Pneumatic and electropneumatic

controllers

� Programmable logic controllers

� Fieldbus systems and accessories

� Timers/counters

� Software for visualisation and data

acquisition

� Display and operating units

� Pipes

� Tubing

� Pipe connectors and fittings

� Electrical connection technology

� Silencers

� Reservoirs

� Air guns

All in all, 100% product and service quality

A customer-oriented range with unlimited flexibility:

Components combine to produce ready-to-install modules and

systems. Included in this are special designs – since at Festo, most

industry-specific products and customer-specific solutions are based

on the 23,000 plus catalogue products. Combined with the services

for the entire value creation sequence, the end result is unbeatable

economy.

< Assembly – for greater speed in the

assembly/commissioning process

< Operation – for greater speed in the

operational process

� Prepack

� Preassembly

� Turnkey pneumatics

�Handling solutions

� Spare parts service

� Energy saving service

� Compressed air consumption

analysis

� Compressed air quality analysis

� Customer service

Page 64: Festo

Info 233 – Subject to change – 2006/0164

Aspects of quality

Quality can be viewed from a number of aspects. A short virtual tour of the Research and Development

department, the Production department or the Customer Service Centre speaks more than a thou-

sand words.

3D engineering and simulation >

Innovation quality Production quality

Let’s look at some of the figures:

� 6.5% of turnover

� 2,800 patents with 100 new

applications every year

� 3D engineering and simulation

� 10,600 employees worldwide

� Each and every one of them a

lateral thinker

Your interest is quality and economy –

therefore we place considerable value

on:

�Minimum production tolerances

�Ultra-modern, proprietary pro-

duction methods

� Core competencies in production

� Defined quality standards across

the entire production chain

� Strict quality assurance systems: on

that you can depend.

Page 65: Festo

2006/01 – Subject to change – Info 233 65

Price quality Range quality Didactic quality

More service for less money.Many of

the new and further developments in

the Festo product range have one

thing in common: they are technically

superior and more attractively priced

than their predecessor product.

Examples are to be found in all prod-

uct segments: among the drives,

valves, valve terminals; among the

service units, and among the range of

accessories.

For individual solutions. Festo offers

components as industry-specific cata-

logue products as well as standards-

based and highly individual special

designs. Ready-to-install combina-

tions of these components play an

integral part in the Festo product port-

folio as modules or systems. Inciden-

tally, an increasing number of compo-

nents can be individually configured

as modular products.

To complement the products and ser-

vices for automation, Festo Didactic

offers exceptionally efficient training

hardware, learning software and sem-

inars of the highest quality. Optimally

tailored to your value creation

sequence.

In short – training in practical ap-

plications for practical application.

Page 66: Festo

Info 233 – Subject to change – 2006/0166

What must be observed when using Festo components?

Specified limit values for technical

data and any specific instructions

must be adhered to by the user in

order to ensure recommended operat-

ing conditions.

When pneumatic components are

used, the user shall ensure that they

are operated using correctly prepared

compressed air without aggressive

media.

When Festo components are used in

safety-oriented applications, the user

shall ensure that all applicable

national and local safety laws and

regulations, for example the machine

directive, together with the relevant

references to standards are observed.

Unauthorised conversions or modifi-

cations to products and systems from

Festo involve a safety risk and are

thus not permissible.

Festo does not accept any liability for

resulting damages.

You should contact Festo’s advisors if

one of the following apply to your

application:

� The ambient conditions and condi-

tions of use or the operating me-

dium differ from the specified

technical data.

� The product is to perform a safety

function.

� A risk or safety analysis is required.

� You are unsure about the product’s

suitability for use in the planned

application.

� You are unsure about the product’s

suitability for use in safety-oriented

applications.

All technical data applies at the time

of going to print.

All texts, representations, illustrations

and drawings included in this cata-

logue are the intellectual property of

Festo AG & Co. KG, and are protected

by copyright law.

All rights reserved, including transla-

tion rights. No part of this publication

may be reproduced or transmitted in

any form or by any means, electronic,

mechanical, photocopying or other-

wise, without the prior written per-

mission of Festo AG & Co. KG. All

technical data subject to change

according to technical update.