Transcript of FEA and Deepwater Project Summary 2007-2015
![Page 1: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/1.jpg)
FEA and Deepwater Project Summary (2007 - 2014)
APS/AWE TUI Expansion Conceptual Project for Magnum Subsea System, New Zealand. 2 water injection manifolds and 2 Gas Lift manifolds
conceptual design project.
Riser stalk on lifting with 13 degrees tilt, Riser upending analysis - Horizontal position 0º, 15º position, 30º position, 45º position, 60º position, 75º position and 90º position
1
![Page 2: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/2.jpg)
Apache Van Gogh Project, Gas Injection Manifold Systems For Exxonmobil, Australia
Light Weight Substructure research and development for OPE Company.
2
![Page 3: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/3.jpg)
9th Well Manifold, Tahiti Development Subsea Project For Chevron North America Exploration & Production Company.
)
Figure 5.0b: Isometric View of 9th well manifold Structure (SACS Model)
Kizomba Manifold Development FEED Project For Exxonmobil, Angola, West Africa.
Isometric View of SDU Structure (SACS Model)
3
![Page 4: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/4.jpg)
Isometric View of UTA Structure (SACS Model)
Isometric View of SDU UTA Structure (SACS Model)
Puffin Development Subsea Manifolds Design for AED.
4
![Page 5: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/5.jpg)
Tahiti North (2 slot) Water Injection Pipeline End Manifold (PLEM) Systems For Chevron North America Exploration & Production Company
5
![Page 6: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/6.jpg)
Tahiti South (4 slot) Water Injection Pipeline End Manifold (PLEM) Systems For Chevron North America Exploration & Production Company
Hub GHO 6"-6" capacity check analysis
6
![Page 7: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/7.jpg)
Hub HCS 28"-23" capacity check analysis
Blind Flange 12" capacity check analysis
7
![Page 8: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/8.jpg)
Blind Flange 24" capacity check analysis
Blind Flange 6" capacity check analysis
8
![Page 9: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/9.jpg)
Test Hub 12" capacity check analysis
GHO strength capacity of guide funnel and guide rods
9
![Page 10: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/10.jpg)
Guide funnel and guide rods welding Capacity
Normal operation Inboard support structure with reaction plate strength capacity analysis - 1st End (6" GHO System)
10
![Page 11: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/11.jpg)
Normal operation Inboard support structure with reaction plate strength capacity analysis - 2nd End (6" GHO System)
Normal operation Inboard support structure with reaction plate strength capacity analysis - 1st End (12" GHO System)
11
![Page 12: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/12.jpg)
Normal operation Inboard support structure with reaction plate strength capacity analysis - 2nd End (12" GHO System)
Wellhead protection structures
12
![Page 13: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/13.jpg)
Pig launcher
Lifting Clamp Analysis
13
![Page 14: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/14.jpg)
10’ Pulp Piece + Blind Flange
Xmas Hydrotest Hub + Blind Hub
14
![Page 15: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/15.jpg)
Water Injection Hub Analysis
Lifting analysis
15
![Page 16: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/16.jpg)
Hydrotest pressure - 8’ Pulp Piece + Blind Flange
Stinger – Trunnion Capacity Check
16
![Page 17: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/17.jpg)
Gangway’s Support Capacity Check
Stern padeye Capacity Check
17
![Page 18: FEA and Deepwater Project Summary 2007-2015](https://reader034.fdocuments.in/reader034/viewer/2022042906/58a396601a28abb1348b4fdd/html5/thumbnails/18.jpg)
18