FD960 Density Meter

download FD960 Density Meter

of 2

Transcript of FD960 Density Meter

  • 7/27/2019 FD960 Density Meter

    1/2ISSUE: FD960/MAY2001/UK

    continuous on-line density measurement

    accuracy to 0.0001g/cm3 reading

    straight through flow

    hazardous area applications

    insensitive to plant / pipeline vibration

    wide operating temperature span

    low pressure drop

    intrinsically safe and compact design

    high flow rate capability

    no on-site calibration required

    secondary containment

    Sarasota

    Fiscal Density Meter

    FD960

    Features

    The Sarasota FD960 density meter is designed for highaccuracy measurement of high value process liquids andslurries.

    Dimensional drawing

    Applications batch control multi-product pipeline metering

    product interface detection custody transfer

    Detailed specification and ordering information: see overleafThermo Measurement reserves the right to alter specifications without notice.

    89mm

    206.5mm

    530mm

    198mm

    128mm

    271mm

  • 7/27/2019 FD960 Density Meter

    2/2

    Specification

    Thermo Electron CorporationKings Worthy

    Winchester, HampshireSO23 7QA, United Kingdom

    Tel: +44 (0) 1962 625000Fax: +44 (0) 1962 885530email: [email protected]

    Thermo Electron Corporation9303 W. Sam Houston Parkway South

    HoustonTexas77099 5298 USA

    Tel: +1 (713) 272 0404Fax: +1 (713) 272 2273

    Ordering Information

    Transducer:

    Operating range: 0 to 2.1g/cm3

    Factory calibration range: 0.65 to 1.6g/cm3

    Accuracy: 0.0001g/cm3

    Repeatability: 0.00002g/cm3

    Temperature effect:

    (corrected) see Note 1 0.000005g/cm3/C

    Process temperature: -50 to +110C

    Pressure effect:

    (corrected) see Note 1 0.000003g/cm3/bar

    Operating pressure: As flange rating

    Materials of construction: Sensor Ni-Span-C

    Other wetted materials 316L

    stainless steel

    Case 316L stainless steel

    Electronics housing copper free

    aluminium grey epoxy finish

    Temperature measurement: High accuracy 13 DIN

    Integral 4 wire PT100General:

    Environmental protection: IP65Hazardous area certification: FD960F EEx ia IIC T6

    EEx d IIC T4/T3

    Weight: Nett 11kg max

    Shipping 20kg max

    Installation: Vertical as standard

    Optionally horizontal

    Flow range: 0-300 l/min

    5-300 l/min when installed horizontally

    Electrical:

    Output: Frequency related to density on 2 wire

    current modulated loop 6mA to 18mA

    4 wire PT100

    Power supply: 16-28 VDC 10mA average (peak 18mA)

    Connections: Screw terminals

    Cable entry: 2 x 34 NPT

    Operating temperature

    (ambient): -20 to +70C

    Note: Where an X option is chosenthe option must be described fully,in writing. Please contact salesoffice for pricing.

    Example: FD960-F-1-F-A0-S

    FD960 fiscal density meter with frequency output, 0.0001g/cm3, standardtemperature range, 1 ANSI Class 600 RF flanges for use in non-hazardous areas.

    Density meter model code format

    FD960 Sarasota Fiscal Density Meter

    Signal output

    F Frequency output

    Transducer accuracy1 0.0001g/cm3

    Temperature range

    F -50 to +110C

    Process connections

    B0 1 ANSI B16.5 Class 150 RF flanges

    B1 1 ANSI B16.5 Class 150 DUPLEX flanges

    F0 1 ANSI B16.5 Class 300 RF flanges

    F1 1 ANSI B16.5 Class 300 DUPLEX flanges

    A0 1 ANSI B16.5 Class 600 RF flanges

    A1 1 ANSI B16.5 Class 600 DUPLEX flanges

    D BS4504 PN40 DN25 RF flanges (form D)

    X Other flange type (see note)

    Certification

    S Non-hazardous / safe area application

    I Intrinsically safe EEx ia IIC T6

    D Flameproof EEx d IIC T4/T3

    Options

    M Wetted parts material certificates (DIN 50049 BS EN 10204 3.1b)

    T Traceable calibration certificate

    Note 1 - Corrected temperature and pressure effects after applying

    correction coefficients

    HART is a registered trademark of the Hart Foundation