FD ELECMAN 2016 CATALOG - fd-japan. · PDF fileOn Delay Time : From 0.2 second to 6 second...
Transcript of FD ELECMAN 2016 CATALOG - fd-japan. · PDF fileOn Delay Time : From 0.2 second to 6 second...
Max. 30A
W/FUSE, RED COVER 2 Coils Normal Open Contact Type
Terminal :
B → BatteryS1, S2 → Dimmer SW or Toggle SWL1, L2 → Head Lamp or Fog & Driving LampS3 → Positive Car : Ground, or Negative Car : Terminal B Wiring Diagram
Max. 20A
W/FUSE, RED COVER 2 Coils Normal Open Contact Type
Terminal :B → BatteryS1, S2 → Dimmer SW or Toggle SWL1, L2 → Head Lamp or Fog & Driving LampS3 → Positive Car : Ground, or Negative Car : Terminal B
Max. 30A
W/O FUSE, BLUE COVER 2 Coils Normal Open Contact Type
12V
SLR-12B 12V
SLR-24B 24V
RELAY SWITCH
HEAD LIGHT RELAY
Terminal Arrangement
Terminal Arrangement
SPECIFICATIONF.D NO.
SLR-12D
W/O FUSE, BLUE COVER 2 Coils Normal Open Contact Type
Terminal :B → BatteryS1, S2 → Dimmer SW or Toggle SWL1, L2 → Head Lamp or Fog & Driving LampS3 → Positive Car : Ground, or Negative Car : Terminal B Wiring Diagram
Max. 20A
W/O FUSE, BLUE COVER 2 Coils Normal Open Contact Type
Terminal :
B → BatteryS1, S2 → Dimmer SW or Toggle SWL1, L2 → Head Lamp or Fog & Driving LampS3 → Positive Car : Ground, or Negative Car : Terminal B
SLR-24D 24V
144
Break Max. 20A / Make Max. 40A1 Coil Change Over Contact for Universal
Terminal :B → Battery through SwitchL1 → Load 1 L2 → Load 2C1 (Round Male Plug Connection) → SwitchC2 (Round Female Plug Connection) → Ground
Wiring Diagram
Break Max. 15A / Make Max. 30A1 Coil Change Over Contact for Universal
Terminal :B → Battery through SwitchL1 → Load 1 L2 → Load 2C1 (Round Male Plug Connection) → SwitchC2 (Round Female Plug Connection) → Ground
Break Max. 30A / Make Max. 60A
With Diode 1 Coil Change Over Contact for Universal
F.D NO.
Screw
connection
Terminal ArrangementSR04A-12C 12V
RELAY SWITCH
HEAVY DUTY RELAY
SR05A-24
SPECIFICATION
Screw
connection
Terminal ArrangementSR05A-12 12V
24V
With Diode 1 Coil Change Over Contact for Universal
W/Water proof skirt
Terminal :B → BatteryC1 → GroundC2 → SwitchL1 → Load of Break SideL2 → Load of Make SideAll Snap-on Connection Wiring Diagram
Break Max. 25A / Make Max. 50A
With Diode 1 Coil Change Over Contact for Universal
W/Water proof skirt
Terminal :B → BatteryC1 → GroundC2 → SwitchL1 → Load of Break SideL2 → Load of Make SideAll Snap-on Connection
Connector Ass'y for SR04A-12C, SR04A-24C RelayAttachment Female Termainal (7116-3250 x 3pcs.) (7116-2090 x 2pcs.)
SR04A-24C 24V
SR04A-601
145
Break Max. 20A / Make Max. 40A
LIGHT YELLOW COVER 1 Coil Change Over Contact for Universal
Terminal :
B → Battery
C1 → GroundC2 → Switch
L1 → Load of Break SideL2 → Load of Make Side
All Snap-on Connection Wiring Diagram
Break Max. 15A / Make Max. 30A
LIGHT YELLOW COVER 1 Coil Change Over Contact for Universal
Terminal :
B → Battery
C1 → Ground
C2 → Switch
L1 → Load of Break Side
L2 → Load of Make Side
All Snap-on Connection
Max. 40A
LIGHT YELLOW COVER 1 Coil Normal Open Contact for Universal
Terminal :
B → Battery
C1 → Ground
C2 → Switch
L2 → Load
All Snap-on Connection
Wiring Diagram
Max. 30A
LIGHT YELLOW COVER 1 Coil Normal Open Contact for Universal
Terminal :B → Battery
C1 → Ground
C2 → Switch
L2 → Load
All Snap-on Connection
5 Female Terminals
Connector Ass'y for SRM, SRN Relay
F.D NO.
RELAY SWITCH
SUPER SMALL RELAY
SRN-24
24V
Terminal Arrangement
Terminal Arrangement
SPECIFICATION
146
SRM-60-4500
SRM-12 12V
24V
SRM-24
SRN-12 12V
Break Max. 20A / Make Max. 40A1 Coil Change Over Contact for Universal
ISO TYPE W/Water proof skirt
Terminal :30 → Battery85 → Ground86 → Switch87 → Load of Make Side87a → Load of Break Side Wiring DiagramAll Snap-on Connection
Break Max. 15A / Make Max. 30A
1 Coil Change Over Contact for Universal
ISO TYPE W/Water proof skirt
Terminal :30 → Battery85 → Ground86 → Switch87 → Load of Make Side87a → Load of Break SideAll Snap-on Connection
Break Max. 20A / Make Max. 40A
With Diode 1 Coil Change Over Contact for Universal
F.D NO.
SR01A-12C 12V
24VSR01A-24B
SR01A-12B 12V
RELAY SWITCH
SUPER SMALL RELAY
Terminal Arrangement
Terminal Arrangement
SPECIFICATION
With Diode 1 Coil Change Over Contact for UniversalISO TYPE W/Water proof skirt
Terminal :30 → Battery85 → Ground86 → Switch87 → Load of Make Side87a → Load of Break Side Wiring DiagramAll Snap-on Connection
Break Max. 15A / Make Max. 30A
With Diode 1 Coil Change Over Contact for UniversalISO TYPE W/Water proof skirt
Terminal :30 → Battery85 → Ground86 → Switch87 → Load of Make Side87a → Load of Break SideAll Snap-on Connection
5 Female TerminalsConnector Ass'y for SR01A-12/24 Relay
SR01A-24C 24V
SR01-5001
147
Max. 20A
1 Coil Normal Open Contact for Universal
Terminal :3 → Battery1 → Switch2 → Ground5 → Load All Snap-on Connection
Wiring Diagram
Max. 15A
1 Coil Normal Open Contact for Universal Terminal :3 → Battery1 → Switch2 → Ground5 → Load All Snap-on Connection
12VTerminal Arrangement
SR02B-24 24V
RELAY SWITCH
SUPER SMALL RELAY
F.D NO. SPECIFICATION
MICRO RELAY
SR02B-12
SR07A-12SR07A-12C W/DIODE Rated Current (Resistance Load)
Break 10A Make 20AW/Water proof skirt
Terminal :3 → Battery1 → Switch2 → Ground4 → Load of Breake Side5 → Load of Make Side
SR07A-24SR07A-24C W/DIODE Rated Current (Resistance Load)
Break 5A Make 10AW/Water proof skirt
Terminal :3 → Battery1 → Switch2 → Ground4 → Load of Breake Side5 → Load of Make Side
SR07A-601Attachment Connector
Connector 1ea.,Female Terminal big size 2pcs.,
small size 3pcs.
F.D NO. SPECIFICATION
24V
General Wiring Diagram W/O Diode
General Wiring Diagram W/Diode
12VTerminal Arrangement
MICRO RELAY
148
On Delay Time : From 0.2 second to 6 second adjustable
ON DELAY TIMER Terminal :B → Battery (Blue Lead Wire)S → Switch (Red Lead Wire)L1 → Load of Break Side (White Lead Wire)L2 → Load of Make Side (Yellow Lead Wire)E → Ground (Black Lead Wire)
Wiring Diagram
On Delay Time : From 0.2 second to 6 second adjustable
ON DELAY TIMER Terminal :B → Battery (Blue Lead Wire)S → Switch (Red Lead Wire)L1 → Load of Break Side (White Lead Wire)L2 → Load of Make Side (Yellow Lead Wire)E → Ground (Black Lead Wire)
Off Delay Time : From 0.1 second to 6 second adjustable
OFF DELAY TIMER
TR01-12
TR04-12 12V
TR01-24 24V
RELAY SWITCH
ON / OFF DELAY TIMER RELAY
F.D NO.
Terminal Arrangement
SPECIFICATION
Terminal Arrangement
12V
B
ES L2
L1
B L1OFF DELAY TIMER
Terminal :
B → Battery (Red Lead Wire)
S → Switch (Blue Lead Wire)L1 → Load of Break Side (White Lead Wire)L2 → Load of Make Side (Yellow Lead Wire)E → Ground (Black Lead Wire)
(Note) Outside view will be changeable.
Wiring Diagram
Off Delay Time : From 0.1 second to 6 second adjustable
OFF DELAY TIMER
Terminal :
B → Battery (Red Lead Wire)
S → Switch (Blue Lead Wire)L1 → Load of Break Side (White Lead Wire)L2 → Load of Make Side (Yellow Lead Wire)E → Ground (Black Lead Wire)
(Note) Outside view will be changeable.
WATERPROOF COVER For TR01-12TR01-24TR03-12TR03-24
SR02-601
TR04-24 24V
B
ES
L1
L2
149
RELAY SWITCHRELAY SWITCHRELAY SWITCH
HAZARD WARNING AND HEAVY DUTY FLASHER RELAYHAZARD WARNING AND HEAVY DUTY FLASHER RELAYHAZARD WARNING AND HEAVY DUTY FLASHER RELAY
SPECIFICATIONF.D NO. SPECIFICATION
FR-24 24V
F.D NO.
Wiring DiagramFR-24 24V
Heavy Duty Transistor type 24V Flasher Relay
25W × 2 + 12W × 13 +3W25W × 2 + 12W × 13 +3W
Hazard Warning Max. 430W (24V 18A)Hazard Warning Max. 430W (24V 18A)
■FR-24 Connection of Terminal■FR-24 Connection of TerminalL (Blue Wire : Male Terminal) ・・・To Lamp through Flasher SwitchL (Blue Wire : Male Terminal) ・・・To Lamp through Flasher SwitchB (Red Wire : Male Terminal) ・・・To Main Switch through FuseB (Red Wire : Male Terminal) ・・・To Main Switch through FuseE (Black Wire : Spade type Terminal) ・・・To GroundE (Black Wire : Spade type Terminal) ・・・To Ground
■Note on Use■Note on Use1. This relay is only for 24V Minus Ground car and is used both as Hazard Warning and Flasher relay.1. This relay is only for 24V Minus Ground car and is used both as Hazard Warning and Flasher relay.2. Make sure not to install this relay at outside of car.2. Make sure not to install this relay at outside of car.3. Installation and removal of this relay should be done after turnoff of main switch.3. Installation and removal of this relay should be done after turnoff of main switch.4. When flashing unstableness and noise occur , change B (Red) wire for4. When flashing unstableness and noise occur , change B (Red) wire for AV or AVS wire more than 2m㎡ from place close to the battery. AV or AVS wire more than 2m㎡ from place close to the battery.
MINI BLADE FUSE HOLDERMINI BLADE FUSE HOLDERMINI BLADE FUSE HOLDER
SPECIFICATIONF.D NO. SPECIFICATIONF.D NO.
MFH-1Double Connection Use is possible.
MFH-1Double Connection Use is possible.
①Two AVS 2m㎡ Red Wires are attached.①Two AVS 2m㎡ Red Wires are attached.
②Fuse(Max. 20A) is not installed.②Fuse(Max. 20A) is not installed.
③This holder is of waterproof.③This holder is of waterproof.
④In case of double connection use, fix the ④In case of double connection use, fix the
Single Use holders to the real machine by vinyl band. Double Connection Use Single Use holders to the real machine by vinyl band. Double Connection Use
150150
Max. 120A (Within 30 seconds)2 Holes Stay Type1 Coil Normal Open Contact
Terminal :B (Screw Connection) → BatteryM (Screw Connection) → Starter Wiring DiagramS (Red Wire Male Terminal) → Starter Switch
Max. 120A (Within 30 seconds)1 Hole Stay Type1 Coil Normal Open Contact
Terminal :B (Screw Connection) → BatteryM (Screw Connection) → Starter Wiring DiagramS (Red Wire Male Terminal) → Starter Switch
Max. 60A (Within 30 seconds)2 Holes Stay Type
RELAY SWITCH
STARTER RELAY
SPECIFICATION
12V
SS090 24V
SS080DB 12V
F.D NO.
SS080DTerminal Arrangement
Terminal Arrangement
Terminal Arrangement
2 Holes Stay Type1 Coil Normal Open Contact
Terminal :B (Screw Connection) → BatteryM (Screw Connection) → Starter Wiring DiagramS1 (White Stripe on Black Wire Male Terminal)→ SwitchS2 (Black Wire Female Terminal) → Ground
Max. 60A (Within 30 seconds)1 Hole Stay Type1 Coil Normal Open ContactTerminal :B (Screw Connection) → BatteryM (Screw Connection) → StarterS1 (White Stripe on Black Wire Male Terminal)→ Switch Wiring DiagramS2 (Black Wire Female Terminal) → Ground
SS090B 24VTerminal Arrangement
151
Rated Current 80A (Continuous)2 Holes Stay Type1 Coil Normal Open Contact
Terminal :B (Screw Connection) → BatteryM (Screw Connection) → Starter Wiring DiagramS (Red Wire Male Terminal) → Starter Switch
JIDECO NO. M2S-1041-2
Rated Current 80A (Continuous)1 Hole Stay Type1 Coil Normal Open Contact
Terminal :B (Screw Connection) → BatteryM (Screw Connection) → Starter Wiring DiagramS (Red Wire Male Terminal) → Starter Switch
Rated Current 50A (Continuous)2 Holes Stay Type
SPECIFICATION
12V
12V
SS160 24V
F.D NO.
SS150D
RELAY SWITCH
STARTER RELAY
SS150DB
Terminal Arrangement
Terminal Arrangement
Terminal Arrangement
2 Holes Stay Type1 Coil Normal Open Contact
Terminal :B (Screw Connection) → BatteryM (Screw Connection) → Starter Wiring DiagramS1 (White Stripe on Black Wire Male Terminal)→ SwitchS2 (Black Wire Female Terminal) → Ground
JIDECO NO. MS2-1002-2
Rated Current 50A (Continuous)1 Hole Stay Type1 Coil Normal Open Contact
Terminal :B (Screw Connection) → BatteryM (Screw Connection) → Starter Wiring DiagramS1 (White Stripe on Black Wire Male Terminal)→ SwitchS2 (Black Wire Female Terminal) → Ground
SS160B 24VTerminal Arrangement
152
Max. 200A (Within 15 minutes)1 Coil Normal Open Double Silver Contact Continuousworking Heavy Duty Type for Battery Forklift, Golf Cart,Industrial Machine Etc.
Terminal :B (8m/mφScrew Connection) → BatteryL (8m/mφScrew Connection) → LoadS1 (5m/mφScrew Connection) → SwitchS2 (5m/mφScrew Connection) → Ground
Wiring Diagram
Max. 100A (Within 15 minutes)1 Coil Normal Open Double Silver Contact Continuousworking Heavy Duty Type for Battery Forklift, Golf Cart,Industrial Machine Etc.
Terminal :B (8m/mφScrew Connection) → BatteryL (8m/mφScrew Connection) → LoadS1 (5m/mφScrew Connection) → SwitchS2 (5m/mφScrew Connection) → Ground
Max. 50A (Within 15 minutes)1 Coil Normal Open Double Silver Contact Continuous
SS2143-48 48V
24VSS2139-24
12V
SPECIFICATION
RELAY SWITCH
SOLENOID RELAY
Terminal Arrangement
F.D NO.
SS2138-12
1 Coil Normal Open Double Silver Contact Continuousworking Heavy Duty Type for Battery Forklift, Golf Cart,Industrial Machine Etc.
Terminal :B (8m/mφScrew Connection) → BatteryL (8m/mφScrew Connection) → LoadS1 (5m/mφScrew Connection) → SwitchS2 (5m/mφScrew Connection) → Ground
SS2140-12 12V
Max. 100A (Within 15 minutes)
1 Coil Normal Open Single Silver Contact Short Timeworking Heavy Duty Type for Battery Forklift,Golf Cart, Industrial Machine Etc.
Terminal :B (8m/mφScrew Connection) → BatteryL (8m/mφScrew Connection) → LoadS1 (5m/mφScrew Connection) → SwitchS2 (5m/mφScrew Connection) → Ground
153
Continuous Rated Current : 120A
NEGATIVE CUT Voltage Drop : Less than 0.3V
Ref. No. (BS-1)
To Suit Industrial MachineWiring Diagram
Continuous Rated Current : 120A
POSITIVE CUT Voltage Drop : Less than 0.3V
Ref. No. 182550-1110 (BS-431, -581)
To Suit Industrial MachineWiring Diagram
Continuous Rated Current : 120A
NEGATIVE CUT Voltage Drop : Less than 0.3V
Ref. No. 8279-0008 / 0018 / 0021 /
0033 / 004325670-C0500 Wiring Diagram(BSE-1), (MSI-24), (BS412)
To Suit Isuzu Bus, Truck,Nissan UD Diesel Truck
Continuous Rated Current : 120A
POSITIVE CUT Voltage Drop : Less than 0.3V
Ref. No. 8279-0052 / 0055 / 0065(BS-H / Q / L)60713-50450 / 50451
Wiring DiagramTo Suit Isuzu Bus, Truck
Hino Truck
Continuous Rated Current : 120A
POSITIVE CUT Voltage Drop : Less than 0.3V
Ref. No 25613-Z0001, (BS-462)
To Suit Nissan UD Diesel Truck Wiring Diagram
RELAY SWITCH
BATTERY RELAY
BS24-1A (4T)
BS12-1A (4T) 12V
F.D NO.
Terminal Arrangement
Terminal Arrangement
154
BS24-5 (4T) 24V
12V
BS24-4A (4T) 24V
SPECIFICATION
BS12-4A (4T)
24V
Terminal Arrangement
Terminal Arrangement
Terminal Arrangement
Continuous Rated Current : 120A
POSITIVE CUT , W/DIODE Voltage Drop : Less than 0.3V
Ref. No. 8255-0008 / 0108 / 0009 / 0109(BS0262 / 232)
To Suit Isuzu Bus, Truck Wiring Diagram
Continuous Rated Current : 120A
POSITIVE CUT , W/DIODE Voltage Drop : Less than 0.3V
Ref. No. KHR2135
To Suit Industrial MachineWiring Diagram
Continuous Rated Current : 120A
POSITIVE CUT , W/DIODE Voltage Drop : Less than 0.3V
F.D NO.
BS12-5C (4T)Terminal Arrangement
Terminal ArrangementBS24-5C (4T)
RELAY SWITCH
BATTERY RELAY
SPECIFICATION
BS24-5B (4T) 24V
24V
Terminal Arrangement
12V
POSITIVE CUT , W/DIODE Voltage Drop : Less than 0.3V
Ref. No. KHR2112
To Suit Industrial MachineWiring Diagram
Continuous Rated Current : 120A
POSITIVE CUT Voltage Drop : Less than 0.3V
Ref. No. 8255-0008 / 60713-52330(BS-262)
Wiring DiagramTo Suit Isuzu Bus, Truck
Continuous Rated Current : 120A
POSITIVE CUT Voltage Drop : Less than 0.3V
Ref. No. 60713-52330, 84490-1060 / 1040A To Suit (0501-161-001 /
Without Fitting Insulator for Truck) Wiring Diagram(0501-161-002 /With Fitting Insulator for Bus)Hino Truck, Bus
BS24-7 (4T) 24VTerminal Arrangement
Terminal ArrangementBS24-5S (4T) 24V
155
RELAY SWITCHRELAY SWITCHRELAY SWITCH
BATTERY RELAYBATTERY RELAYBATTERY RELAY
F.D NO. SPECIFICATION
Terminal Arrangement
F.D NO.
BS24-8 (4T) 24V
SPECIFICATION
Continuous Rated Current : 120A
Terminal ArrangementBS24-8 (4T) 24V
NEGATIVE CUT, W/DIODE Voltage Drop : Less than 0.3V
Ref. No. 0-8088-10000 (BS-402, BS2-0421)Ref. No. 0-8088-10000 (BS-402, BS2-0421)To Suit Sumitomo Industrial MachineTo Suit Sumitomo Industrial Machine
Wiring DiagramWiring Diagram
156156