Fant-f Uds 3fe53701bdaatqzza01

download Fant-f Uds 3fe53701bdaatqzza01

of 12

description

FANT-F

Transcript of Fant-f Uds 3fe53701bdaatqzza01

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 1 / 12

    7360 ISAM FANT-F

    1 Identification 2

    2 Introduction 2

    3 Features and application notes 2

    4 General description 3

    5 Functional description 4

    6 External interfaces 6

    7 Alarm processing 8

    8 Physical description 8

    9 Power supply 11

    FANT-F

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 2 / 12

    FANT-F 7360 ISAM FANT-F

    1 Identification

    Table 1 identifies the FANT-F.

    Table 1 Identification of the FANT-F

    2 Introduction

    This document describes the 7360 ISAM FANT-F NT card which is part of the 7360 Intelligent Services Access Manager FX (7360 ISAM FX) for ANSI.

    3 Features and application notes

    The FANT-F provides the following features:

    is an NT card with a 480 Gbps switch can be used in a 7360 ISAM FX shelf has four SFP+ 10 Gigabit Ethernet (10 GE) interfaces. The SFP+ interfaces

    support 1 GE and 10 GE data rates. has one 10/100/1000Base-T interface supports NT I/O supports synchronized Ethernet (SyncE) supports 1PPS / Time of Day (ToD) interface supports precision time protocol (PTP) IEEE 1588v2 supports synchronous Ethernet link data clock extraction for network timing

    reference (NTR) use: from the SFP+ interfaces on its front plate from two 1 GE or 10 GE interfaces on the NTIO

    can be used in the following operational conditions: 5C to +45C (23F to 113F) ambient temperature range, in a central office (CO)

    environment with multiple 7360 ISAM FX shelves 40C to +70C (40F to 158F) in stand-alone 7360 ISAM FX shelves

    is hot-swappable is compliant to safety standards UL 60950-1 2nd Edition and CAN/CSA-C22.2

    No. 60950-1-07, provided that the board is installed, maintained, and used according the relevant installation instructions

    Part Number Mnemonic Name

    3FE 53701 BD FANT-F 7360 ISAM FANT-F NT card

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 3 / 12

    FANT-F7360 ISAM FANT-F

    4 General description

    The FANT-F is responsible for:

    the routing/switching and the aggregation of end-user data streams to and from network interfaces and/or uplink interfaces

    centralized shelf control and management system clock generation network timing reference (NTR) generation, synchronous equipment timing

    source (SETS) centralized shelf alarm processing and reporting

    The LT cards are responsible for the physical termination of user interfaces and non-blocking user aggregation.

    The FANT-F must be used at the NT-A or the NT-B position, or both, of the 7360 ISAM FX shelf. Figure 1 shows the position of the FANT-F in the ISAM system.

    Figure 1 Position of the FANT-F in the ISAM system

    NTIOA

    NTIOB

    AlarmIO board

    Power unit

    22446

    NT-B(FANT-F)

    LT #0

    ManagementA interface

    ManagementB interface

    Uplinknetwork

    interfaces

    LT #1

    LT #N-1

    LT #N

    NT-A(FANT-F)

    ISAM system

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 4 / 12

    FANT-F 7360 ISAM FANT-F

    5 Functional description

    Figure 2 shows the different functional blocks of the FANT-F.

    Figure 2 Functional blocks of the FANT-F

    CISC

    ACU

    NUTS

    10MHz GPSinterface

    BITS interfaceToD and 1HzinterfaceNT reference clock

    Peer NTreference inputPeer NTToD/1PPS

    NT-NTcommunication ltfNT-NTswitch-over ltfNT speciallines ltfNT serialI/O ltfNT active/standby ltfNT backplane(NTIO)Serialmanagement ltf

    Remote craftinterfaceSerial alarminterface

    LT reference clocks NT ToD/1PPS

    ToD and 1PPS interface

    NT frontsystemLEDs

    Local craftinterface

    NT front uplinkinterface #0

    NT front uplinkinterface #4

    NT frontuplink LEDs

    LT serdesItf#1 LT serdesItf#2LT serdesItf#16Backplane uplink Itf#0Backplane uplink Itf#4Backplane uplink Itf#7NT-NT loassharing Itf

    NTIO/NTAP-powering ItfNT power supply Itf SMAS-powering Itf

    REFIN

    BIM

    REFOUT

    PNTIN

    HIPC

    SOI

    SLI

    SIO

    SAS

    BSM

    RCMI

    SAI

    LT1LT2

    LT16BUI0BUI4BUI7NNLS

    FIM

    REFIN

    REFOUT

    SYSLED

    UPLED

    LCMI

    FUI#0

    FUI#4

    MCSD

    PSIM

    PBA-FANT-F

    22445

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 5 / 12

    FANT-F7360 ISAM FANT-F

    The following subsections describe the functional blocks.

    CISCThe centralized ISAM system controller (CISC) implements all on-board controller (OBC) functions, which accommodates a centralized control and management approach of the complete ISAM shelf. The CISC also provides the necessary processing capabilities for Ethernet packets and frames forwarded to the main OBC from the GE switching module.

    MCSDThe master clock synchronization and distribution (MSCD) provides the following functionality:

    system network timing reference (NTR) synchronization input references from BITS/SSU, synchronous Ethernet input

    link data clocks, IEEE-1588 ordinary or boundary clock, GPS input references and ToD data clock inputs

    synchronized output reference clocks toward: the shelf-based LTs (backplane connections): 8 kHz or 19.44 MHz the internal NTR signal from the active NT to the standby NT in a redundant NT pair (backplane connection): 8 kHz the external BITS/SSU out interface (located at the front of the General Facilities

    Card): independently configurable to 2048 kHz, E1 or DS1 signal performance for SSU/BITS input/output: compliance with ITU-T G.813 Option

    2: ANSI performance for synchronous Ethernet (SyncE) input/output: compliance with

    ITU-T G.8262 Option 2: ANSI performance for ToD/1PPS input/output: compliance to IEEE 1588v2

    NUTSThe network/user transport and switching (NUTS) provides the interface and switching circuitry for the front and back related uplink/network interfaces to/from the LT slots.

    PSIMThe power supply interface module (PSIM) converts the rack power supply into all necessary voltages as required by the used components.

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 6 / 12

    FANT-F 7360 ISAM FANT-F

    FIMThe front panel interface module (FIM) located at the front stiffener holds the physical interfaces (four SFP+, one 10/100/1000Base-T interface) together with a visual port status indication. The FIM also hosts a management interface (CRAFT).

    BIMThe backplane interface module (BIM) provides the necessary control, management, and data plane related interface inside the complete ISAM system.

    6 External interfaces

    Following are the external interfaces that are accessible through the front panel.

    Communication interfacesFive communication interfaces are available through the front panel:

    1 x fixed 10/100/1000Base-T port: This port can work in 10 Mbps, 100 Mbps, or 1 GE mode.

    4 x 10 GE SFP+ port:This port can work in 1 GE mode (with standard SFP optics) and in 10 GE mode (with SFP+ optics).

    Management interfacesThe following management interface is available through the front panel:

    local craft management interface (LCMI) (RJ45 connector)

    The following clock interfaces are available through the front panel:

    ToD/1PPS interface (RJ-45 connector) 10 MHz GPS interface (SMA connector) 1 PPS interface (SMA connector)

    Local craft interface

    Table 2 describes the signal list and connector pinning (RJ45).

    Note Any of the five communication interfaces can also be used as a management interface.

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 7 / 12

    FANT-F7360 ISAM FANT-F

    Table 2 Local craft interface pinning

    The FANT-F local craft port serial connection settings are as follows:

    interface type: DCEPHY Protocol: Asynchronous (RS232-D) 1 start-bit, 8 data-bits with no parity and 1 stop-bit HW handshaking as per ITU-T V.28 cable distance: 5 m maximum

    ToD and 1Hz validation pulse input interface

    The FANT-F provides a ToD port on its front panel. This interface consists of differential ToD and 1PPS signals (RS-422 technology), mapped on a RJ45 connector.

    Table 3 shows the signals of the ToD interface.

    Table 3 TOD/1PPS-interface signal list of the front panel

    Signal name Description Type Pin no. Technology

    LCMI_RI_DSR Local-craft-mgt-itf data-set-ready O 1 EIA/TIA-562

    LCMI_DCD Local-craft-mgt-itf data-carrier-detect O 2 EIA/TIA-562

    LCMI_DTR Local-craft-mgt-itf data-terminal-ready I 3 EIA/TIA-562

    EG Electrical ground or signal ground Ref. 4 Ref .

    LCMI_RXD Local-craft-mgt-itf related serial receive-data O 5 EIA/TIA-562

    LCMI_TXD Local-craft-mgt-Iif related serial transmit-data I 6 EIA/TIA-562

    LCMI_CTS Local-craft-mgt-itf clear-to-send O 7 EIA/TIA-562

    LCMI_RTS Local-craft-mgt-itf request-to-dend I 8 EIA/TIA-562

    Signals Description Type RJ45 pin

    ToD_UART_T/F ToD UART TX, PTP master mode (differential pair, 100 ohm) O 8, 7

    ToD UART RX, PTP slave mode (differential pair, 100 ohm) I

    ToD_1PPS_T/F 1 PPS output, PTP master mode (differential pair, 100 ohm) O 6, 3

    1 PPS input, PTP slave mode (differential pair, 100 ohm) I

    EG Electrical ground REF 4, 5

    FG Frame ground REF CASE

    NC Not connected - 1, 2

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 8 / 12

    FANT-F 7360 ISAM FANT-F

    1 PPS TTL interface on the SMA connector

    Table 4 describes the signals of the 1 pulse-per-second interface on the SMA connector.

    Table 4 1 PPS Interface on the SMA connector: signal-list

    10 MHz GPS interface on the SMA connector

    Table 5 describes the signals of the 10 MHz GPS interface on the SMA connector.

    Table 5 10MHz GPS interface on the SMA connector: Signal-List

    7 Alarm processing

    A dedicated alarm I/O functional block located in the General Facilities card performs the collection of internal and external alarms and the alarm cutoff . The FANT-F reads and writes alarms through an I2C interface. Alarm processing and handling is performed by CISC.

    8 Physical description

    Figure 3 shows the side and front view of the FANT-F.

    Signals Description Type Technology

    1PPS-TTL 1 PPS output, PTP slave mode (single-ended, 50 ) O TTL

    1 PPS input, PTP master mode (single-ended, 50 ) I TTL

    Shield Frame ground I Ref.

    Signals Description Type Technology

    10M_GPS-IN 10 MHz GPS timing reference (sine wave, 50 , transformer coupled) I 2 to 5 VPP

    Shield Frame ground I Ref.

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 9 / 12

    FANT-F7360 ISAM FANT-F

    Figure 3 Side and front view of the FANT-F

    Dimensions:The dimensions of the FANT-F are:

    height: 405 mm (15.94 in.) width: 30 mm (1.18 in.) depth: 205/225 mm (8.07/8.86 in.) weight: 2 kg (4.4 lb)

    System status LEDSFigure 4 shows the system status LEDs of the FANT-F.

    LEDs

    SFPs

    1 PPS signal10 MHz signalFront uplink interfaceCraft interfaceToD interface

    22447

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 10 / 12

    FANT-F 7360 ISAM FANT-F

    Figure 4 FANT-F system status LEDs

    Table 6 describes the system status LEDS on the FANT-F.

    Table 6 System status LED definition

    Port Description

    PWR Green - power present Off - no power

    A/S Green - active Off - stand-by

    ALM Red - alarm condition exists Off - no alarm condition exists

    PORT1PORT2PORT3PORT4

    Link/activity status (module 1) Link/activity status (module 2) Link/activity status (module 3) Link/activity status (module 4)

    ALM

    FANT-F

    PWR

    A/SPORT2

    PORT4

    PORT1

    PORT3

    22448

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 11 / 12

    FANT-F7360 ISAM FANT-F

    9 Power supply

    The FANT-F is compatible with 48 Vdc nominal and 60 Vdc nominal power supply systems.

    Caution Country-dependent tolerances exist regarding the nominal battery voltage values.

  • 3FE 53701 BDAA TQZZA Edition 01 May 2012 12 / 12

    FANT-F 7360 ISAM FANT-F

    7360 ISAM FANT-F1 Identification2 Introduction3 Features and application notes4 General description5 Functional descriptionCISCMCSDNUTSPSIMFIMBIM

    6 External interfacesCommunication interfacesManagement interfacesLocal craft interfaceToD and 1Hz validation pulse input interface1 PPS TTL interface on the SMA connector10 MHz GPS interface on the SMA connector

    7 Alarm processing8 Physical descriptionDimensions:System status LEDS

    9 Power supply